127 resultados para ventricular aneurysm
Resumo:
BACKGROUND: Intracoronary administration of autologous bone marrow-derived mononuclear cells (BM-MNC) may improve remodeling of the left ventricle (LV) after acute myocardial infarction. The optimal time point of administration of BM-MNC is still uncertain and has rarely been addressed prospectively in randomized clinical trials. METHODS AND RESULTS: In a multicenter study, we randomized 200 patients with large, successfully reperfused ST-segment elevation myocardial infarction in a 1:1:1 pattern into an open-labeled control and 2 BM-MNC treatment groups. In the BM-MNC groups, cells were administered either early (ie, 5 to 7 days) or late (ie, 3 to 4 weeks) after acute myocardial infarction. Cardiac magnetic resonance imaging was performed at baseline and after 4 months. The primary end point was the change from baseline to 4 months in global LV ejection fraction between the 2 treatment groups and the control group. The absolute change in LV ejection fraction from baseline to 4 months was -0.4±8.8% (mean±SD; P=0.74 versus baseline) in the control group, 1.8±8.4% (P=0.12 versus baseline) in the early group, and 0.8±7.6% (P=0.45 versus baseline) in the late group. The treatment effect of BM-MNC as estimated by ANCOVA was 1.25 (95% confidence interval, -1.83 to 4.32; P=0.42) for the early therapy group and 0.55 (95% confidence interval, -2.61 to 3.71; P=0.73) for the late therapy group. CONCLUSIONS: Among patients with ST-segment elevation myocardial infarction and LV dysfunction after successful reperfusion, intracoronary infusion of BM-MNC at either 5 to 7 days or 3 to 4 weeks after acute myocardial infarction did not improve LV function at 4-month follow-up. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00355186.
Resumo:
BACKGROUND AND OBJECTIVE: Off-pump coronary artery bypass grafting has stimulated the development of micro-pumps designed to prevent the hemodynamic instability induced by heart luxation for the exposure of target vessels of the posterior wall. Impella (Aachen, Germany) developed micro-pumps with a miniaturized propeller system for both sides of the heart. The aim of this study was to analyze the impact of both pumps working together on blood cell integrity. MATERIALS AND METHODS: Both right and left-sided micro-pumps were implanted in 5 calves (body weight, 72_4 Kg) during 3 h. Blood samples for hematology and hemolysis parameters were drawn hourly. RESULTS: Both pumps performed well with a flow of 3.6 L +/- 0.3 L during the 3 h of the experiment with stable hemodynamic conditions. Mixed venous oxygen saturation was 63.4 +/- 15.2% at baseline and 63.8 +/- 16.3% at the end of the experiment (P = ns). Red cell count, LDH and free plasma hemoglobin were 6.7 +/- 2.1 x 10(12)/L, 1807 +/- 437 IU/L, and 32 +/- 9 mg/L at baseline vs. 6.1 +/- 2.1 x 10(12)/L, 1871 +/- 410 IU/L, and 52 +/- 9 mg/L at the end of the experiment (P = ns for all comparisons). Platelet count exhibited a non-significant drop (872 +/- 126 vs. 715 +/- 22 x 10(9)/L). CONCLUSIONS: This double pump system based on the Archimed screw principle is hematologically well tolerated under conditions of prolonged cardiac assist.
Resumo:
OBJECTIVE: Off-pump trans left ventricular approach provides more precise deployment of stented aortic valve of any size with respect to the endovascular replacement. One of the key steps of this procedure is the ventricle repair after catheter withdrawing. We designed an animal study to compare the consistency of a sutureless repair of the left ventricle access using nitinol occluder with and without pericardial cuff on the ventricular side. METHODS: Material description: The Amplatz-nitinol occluder consists of two square heads squeezing ventricle wall in between them, sealing the defect. To improve its sealing property, a pericardial patch was sutured to the ventricular head of the occluder. Animal study setup: In adult pigs, a 30F sheath was inserted into the epigastric area through the cardiac apex, up to the left ventricle, simulating the approach for off-pump aortic valve replacement. The sheath was then removed and the ventricle closed with standard occluder in half of the animals, and cuffed occluder in the other half. Animals were followed-up for 3h, collecting haemodynamics data and pericardial bleeding. RESULTS: Device was successfully deployed in 12 animals in less than 1min. In the group where the standard occluder was used, bleeding during the deployment was 80+/-20ml and after the deployment was 800+/-20ml over 3h. In the group where the cuffed occluder was used, bleeding during the deployment was 85+/-20ml and after the deployment was 100+/-5ml over 3h. In the cuffed group, bleeding was significantly lower than the standard group, p-value being <0.001. CONCLUSIONS: The occluder is easy to use and the pericardial cuff dramatically increases its efficacy as demonstrated by a significant reduction of blood loss. The cuffed occluder opens the way for endoscopic, off-pump, transventricular aortic valve replacement.
Resumo:
The diagnosis of infections involving internal or external neurosurgical drainage devices is challenging, and to our knowledge no single reliable microbiological test exists. We used sonication to study bacterial colonization in 14 explanted external ventricular drains (EVD) and 13 ventriculo-peritoneal shunt (VPS) devices. This technique dislodges biofilm bacteria from the surface of implanted materials before culture. Removed devices were sonicated in saline (40 kHz, 1 minute, 0.25 W/cm(2)), the resulting fluid was cultured aerobically and anaerobically at 37°C, and bacterial growth was counted. Ventricular cerebrospinal fluid (CSF) was cultured separately. In the EVD group, sonication cultures grew significantly more bacteria (64%, 9/14) than cultures of aspirated ventricular CSF (14%, 2/14). In the VPS group the difference was not significant. Positive sonication cultures of EVD catheters yielded a median of >100 colony forming units (CFU) (range, 60-800). For positive sonication cultures of VPS, the median was 1000 CFU (range, 20-100,000). All patients with bacteria in their CSF also had positive sonication cultures from the removed device. Of the five patients with sterile or presumably contaminated CSF cultures but positive sonication cultures of removed shunts, one became afebrile after removal of the EVD, two developed meningitis and two remained asymptomatic. Sonication culture of EVD appears to improve the microbiological assessment of device-related infection and it corroborates with CSF cultures of revision surgery for VPS. Sonication of the removed EVD tip may raise awareness for the onset of meningitis.
Resumo:
BACKGROUND: The impact of preoperative impaired left ventricular ejection fraction (EF) in octogenarians following coronary bypass surgery on short-term survival was evaluated in this study. METHODS: A total of 147 octogenarians (mean age 82.1 ± 1.9 years) with coronary artery diseases underwent elective coronary artery bypass graft between January 2000 and December 2009. Patients were stratified into: Group I (n = 59) with EF >50%, Group II (n = 59) with 50% > EF >30% and in Group III (n = 29) with 30% > EF. RESULTS: There was no difference among the three groups regarding incidence of COPD, renal failure, congestive heart failure, diabetes, and preoperative cerebrovascular events. Postoperative atrial fibrillation was the sole independent predictive factor for in-hospital mortality (odds ratio (OR), 18.1); this was 8.5% in Group I, 15.3% in Group II and 10.3% in Group III. Independent predictive factors for mortality during follow up were: decrease of EF during follow-up for more that 5% (OR, 5.2), usage of left internal mammary artery as free graft (OR, 18.1), and EF in follow-up lower than 40% (OR, 4.8). CONCLUSIONS: The results herein suggest acceptable in-hospital as well short-term mortality in octogenarians with impaired EF following coronary artery bypass grafting (CABG) and are comparable to recent literature where the mortality of younger patients was up to 15% and short-term mortality up to 40%, respectively. Accordingly, we can also state that in an octogenarian cohort with impaired EF, CABG is a viable treatment with acceptable mortality.
Resumo:
OBJECTIVES: The Contegra bioprosthesis (valved heterologous bovine jugular vein) is used for reconstruction of the right ventricular outflow tract (RVOT) in congenital heart malformations and pulmonary valve replacement in different settings. Compared to pulmonary homografts, the Contegra conduit is readily available 'on the shelf'. So far, its use was mainly described in children. The aim of this study is to evaluate the feasibility and the outcome of Contegra graft implantation in the adult. METHODS: Between November 1999 and December 2007, a total of 32 Contegra grafts were implanted in 31 patients (24 men and 7 women), with a mean age of 35.7+/-10.5 years (range 18-54 years). All operations have been completed through median sternotomy with cardiopulmonary bypass. Indications included: Ross procedure for aortic valve disease (n=22); re-operation of corrected Fallot-tetralogy (n=5); isolated pulmonary valve disease (n=2); re-operation of double outlet right ventricle (DORV) (n=1); pulmonary stenosis in congenital dilated cardiomyopathy (DCM) (n=1). Conduit sizes included 22 mm (n=31), 20 mm (n=1). RESULTS: There was no hospital mortality and no valved conduit related early morbidity. In the median follow-up of 38 months (range 1-99 months) of 28 patients there was one late death, not conduit related (total mortality 3.6%). Re-operation for symptomatic graft stenosis was realised in two patients, 7 and 16 months after primo-implantation, corresponding to graft related late morbidity of 7.1%. CONCLUSIONS: In this small review of 32 operations using the Contegra graft for RVOT reconstruction in adult cardiac surgery for different indications, we observed good postoperative mid-term results concerning conduit function. Mean transpulmonary pressure gradients remain low (13.3+/-6.6 mmHg postoperative, 14.5+/-7.9 mmHg at follow-up). The use of the Contegra graft seems to be a good alternative to the homograft with low operative mortality and morbidity. Long-term outcome data are not available and further investigations must be performed to evaluate results.
Resumo:
A 28-year-old woman consulted for disabling pulsatile tinnitus. Clinical examination suggested a venous etiology. An aneurysm of the transverse-sigmoid sinus was identified on computed tomography angiography (CTA) and confirmed by digital subtraction angiography. Endovascular occlusion of the aneurysm with detachable coils permanently eliminated the bruit. Thus, this report is of a new case of pulsatile tinnitus caused by an aneurysm of the transverse-sigmoid sinus, with a focus on a literature review and etiopathophysiology. Embryological studies suggest that these aneurysms represent a partial remnant of the petrosquamous sinus.
Resumo:
OBJECTIVE: Fish oil (FO) may attenuate the inflammatory response after major surgery such as abdominal aortic aneurysm (AAA) surgery. We aimed at evaluating the clinical impact and safety aspects of a FO containing parenteral nutrition (PN) after AAA surgery. METHODS: Intervention consisted in 4 days of either standard (STD: Lipofundin medium-chain triglyceride (MCT): long-chain triglyceride (LCT)50%-MCT50%) or FO containing PN (FO: Lipoplus: LCT40%-MCT50%-FO10%). Energy target were set at 1.3 times the preoperative resting energy expenditure by indirect calorimetry. Blood sampling on days 0, 2, 3 and 4. Glucose turnover by the (2)H(2)-glucose method. Muscle microdialysis. Clinical data: maximal daily T degrees, intensive care unit (ICU) and hospital stay. RESULTS: Both solutions were clinically well tolerated, without any differences in laboratory safety parameters, inflammatory, metabolic data, or in organ failures. Plasma tocopherol increased similarly; with FO, docosahexaenoic and eicosapentaenoic acid increased significantly by day 4 versus baseline or STD. To increased postoperatively, with a trend to lower values in FO group (P=0.09). After FO, a trend toward shorter ICU stay (1.6+/-0.4 versus 2.3+/-0.4), and hospital stay (9.9+/-2.4 versus 11.3+/-2.7 days: P=0.19) was observed. CONCLUSIONS: Both lipid emulsions were well tolerated. FO-PN enhanced the plasma n-3 polyunsaturated fatty acid content, and was associated with trends to lower body temperature and shorter length of stay.
Resumo:
Quadricuspid aortic valve (QAV) is a rare congenital anomaly associated with aortic valve insufficiency and significant morbidity, and requires the replacement or, rarely, the repair of the malfunctioning heart valve. A QAV associated with an ascending aorta aneurysm is an extremely rare anatomic combination with a hypothetical, but not clear, shared embryological etiology. To date, only two cases of type B QAV with ascending aorta aneurysm have been reported. Herein is described the first ever case of a 38-year-old male suffering from severe symptomatic aortic valve regurgitation due to a type A QAV, associated with an ascending aorta aneurism, who underwent a successful combined replacement of the aortic valve and ascending aorta.
Resumo:
Angiotensin II is a potent arterial vasoconstrictor and induces hypertension. Angiotensin II also exerts a trophic effect on cardiomyocytes in vitro. The goals of the present study were to document an in vivo increase in cardiac angiotensins in the absence of elevated plasma levels or hypertension and to investigate prevention or regression of ventricular hypertrophy by renin-angiotensin system blockade. We demonstrate that high cardiac angiotensin II is directly responsible for right and left ventricular hypertrophy. We used transgenic mice overexpressing angiotensinogen in cardiomyocytes characterized by cardiac hypertrophy without fibrosis and normal blood pressure. Angiotensin-converting enzyme inhibition and angiotensin II type 1 receptor blockade prevent or normalize ventricular hypertrophy. Surprisingly, in control mice, receptor blockade decreases tissue angiotensin II despite increased plasma levels. This suggests that angiotensin II may be protected from metabolization by binding to its receptor. Blocking of the angiotensin II type 1 receptor rather than enhanced stimulation of the angiotensin II type 2 receptor may prevent remodeling and account for the beneficial effects of angiotensin antagonists.
Resumo:
BACKGROUND: Extrahepatic Portal vein aneurysm (EPVA) is a rare finding that may be associated with different complications, e.g. thrombosis, rupture, portal hypertension and compression of adjacent structures. It is being diagnosed more frequently with the advent of modern cross-sectional imaging. Our review of the English literature disclosed 13 cases of thrombosed EPVA. CASE PRESENTATION: A 50-years-old woman presented with acute abdominal pain but no other symptom. She had no relevant medical history. Palpation of the right upper quadrant showed tenderness. Laboratory tests were unremarkable. A computed tomography showed portal vein aneurysm measuring 88 × 65 mm with thrombosis extending to the superior mesenteric and splenic vein. The patient was treated conservatively with anticoagulation therapy. She was released after two weeks and followed on an outpatient basis. At two months, she reported decreased abdominal pain and her physical examination was normal. A computed tomography was performed showing a decreased thrombosis size and extent, measuring 80 × 55 mm. CONCLUSIONS: Although rare, surgeons should be made aware of this entity. Complications are various. Conservative therapy should be chosen in first intent in most cases. We reported the case of the second largest thrombosed extra-hepatic PVA described in the literature, treated by anticoagulation therapy with a good clinical and radiological response.
Resumo:
BACKGROUND: Catecholaminergic polymorphic ventricular tachycardia (CPVT) is an inherited arrhythmia syndrome associated with mutations in the cardiac ryanodine receptor gene (Ryr2) in the majority of patients. Previous studies of CPVT patients mainly involved probands, so current insight into disease penetrance, expression, genotype-phenotype correlations, and arrhythmic event rates in relatives carrying the Ryr2 mutation is limited. METHODS AND RESULTS: One-hundred sixteen relatives carrying the Ryr2 mutation from 15 families who were identified by cascade screening of the Ryr2 mutation causing CPVT in the proband were clinically characterized, including 61 relatives from 1 family. Fifty-four of 108 antiarrhythmic drug-free relatives (50%) had a CPVT phenotype at the first cardiological examination, including 27 (25%) with nonsustained ventricular tachycardia. Relatives carrying a Ryr2 mutation in the C-terminal channel-forming domain showed an increased odds of nonsustained ventricular tachycardia (odds ratio, 4.1; 95% CI, 1.5-11.5; P=0.007, compared with N-terminal domain) compared with N-terminal domain. Sinus bradycardia was observed in 19% of relatives, whereas other supraventricular dysrhythmias were present in 16%. Ninety-eight (most actively treated) relatives (84%) were followed up for a median of 4.7 years (range, 0.3-19.0 years). During follow-up, 2 asymptomatic relatives experienced exercise-induced syncope. One relative was not being treated, whereas the other was noncompliant. None of the 116 relatives died of CPVT during a 6.7-year follow-up (range, 1.4-20.9 years). CONCLUSIONS: Relatives carrying an Ryr2 mutation show a marked phenotypic diversity. The vast majority do not have signs of supraventricular disease manifestations. Mutation location may be associated with severity of the phenotype. The arrhythmic event rate during follow-up was low.
Resumo:
ECG criteria for left ventricular hypertrophy (LVH) have been almost exclusively elaborated and calibrated in white populations. Because several interethnic differences in ECG characteristics have been found, the applicability of these criteria to African individuals remains to be demonstrated. We therefore investigated the performance of classic ECG criteria for LVH detection in an African population. Digitized 12-lead ECG tracings were obtained from 334 African individuals randomly selected from the general population of the Republic of Seychelles (Indian Ocean). Left ventricular mass was calculated with M-mode echocardiography and indexed to body height. LVH was defined by taking the 95th percentile of body height-indexed LVM values in a reference subgroup. In the entire study sample, 16 men and 15 women (prevalence 9.3%) were finally declared to have LVH, of whom 9 were of the reference subgroup. Sensitivity, specificity, accuracy, and positive and negative predictive values for LVH were calculated for 9 classic ECG criteria, and receiver operating characteristic curves were computed. We also generated a new composite time-voltage criterion with stepwise multiple linear regression: weighted time-voltage criterion=(0.2366R(aVL)+0.0551R(V5)+0.0785S(V3)+ 0.2993T(V1))xQRS duration. The Sokolow-Lyon criterion reached the highest sensitivity (61%) and the R(aVL) voltage criterion reached the highest specificity (97%) when evaluated at their traditional partition value. However, at a fixed specificity of 95%, the sensitivity of these 10 criteria ranged from 16% to 32%. Best accuracy was obtained with the R(aVL) voltage criterion and the new composite time-voltage criterion (89% for both). Positive and negative predictive values varied considerably depending on the concomitant presence of 3 clinical risk factors for LVH (hypertension, age >/=50 years, overweight). Median positive and negative predictive values of the 10 ECG criteria were 15% and 95%, respectively, for subjects with none or 1 of these risk factors compared with 63% and 76% for subjects with all of them. In conclusion, the performance of classic ECG criteria for LVH detection was largely disparate and appeared to be lower in this population of East African origin than in white subjects. A newly generated composite time-voltage criterion might provide improved performance. The predictive value of ECG criteria for LVH was considerably enhanced with the integration of information on concomitant clinical risk factors for LVH.