157 resultados para urinary


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Urinary creatinine excretion is used as a marker of completeness of timed urine collections, which are a keystone of several metabolic evaluations in clinical investigations and epidemiological surveys. METHODS: We used data from two independent Swiss cross-sectional population-based studies with standardised 24-hour urinary collection and measured anthropometric variables. Only data from adults of European descent, with estimated glomerular filtration rate (eGFR) ≥60 ml/min/1.73 m2 and reported completeness of the urinary collection were retained. A linear regression model was developed to predict centiles of the 24-hour urinary creatinine excretion in 1,137 participants from the Swiss Survey on Salt and validated in 994 participants from the Swiss Kidney Project on Genes in Hypertension. RESULTS: The mean urinary creatinine excretion was 193 ± 41 μmol/kg/24 hours in men and 151 ± 38 μmol/kg/24 hours in women in the Swiss Survey on Salt. The values were inversely correlated with age and body mass index (BMI). CONCLUSIONS: We propose a validated prediction equation for 24-hour urinary creatinine excretion in the general European population, based on readily available variables such as age, sex and BMI, and a few derived normograms to ease its clinical application. This should help healthcare providers to interpret the completeness of a 24-hour urine collection in daily clinical practice and in epidemiological population studies.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study is to compare the accuracy of prenatal ultrasound (US) and prenatal magnetic resonance imaging (MRI) in the diagnosis and characterization of congenital abnormalities of the genito-urinary tract and to determine if the additional information obtained by MRI may influence the management of the fetus. We retrospectively evaluate 15 cases of congenital genito-urinary tract anomalies detected by prenatal US and with echographic inconclusive diagnosis. We compare the MRI findings with the US findings and the final diagnosis, obtained from neonatal outcomes, imaging studies and pathology records. Fetal US diagnosis was correct in 9 cases (60%) and MRI in 13 cases (86.7%). Prenatal MRI revealed additional information to US in 9 cases (60%), which modified the initial US diagnosis in 5 cases (33.3%) and changed the therapeutic approach in 5 fetuses (33.3%). Fetal MRI was better than US in cases of oligoamnios and in fetuses with genito-urinary pathology concerning the pelvic and perineum region. We believe that MRI should be considered as a complementary diagnostic method in cases of echographic suspicion of congenital pathology of the genito-urinary tract and inconclusive prenatal US.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: There are only a few established artificial urinary sphincters for treatment of incontinence. We have developed a new device composed by three parts: the actuator, three contractile rings and a control unit. The actuator is made of Nitinol fibers, driven by microprocessor. The fibers are linked to the rings placed around the urethra. They function with alternance in their open and closed position. This concept is called piano concept. With this set-up, the constant compression on the urethra is strongly reduced. Methods: Six male sheep have been used for this study. The sphincter was open each hour for a period of 10 min., to guaranty urination. The bladder was filled with water while one cuff was closed and bladder pressure was monitored. The animals were sacrificed. Two biopsies around two cuffs of each explant and all three cuffs from each explant including urethra were analyzed. Urethra not surrounded by a cuff was taken as control. Results: The pressure exerted by the sphincter around the urethra provided continence. Simulated incontinence occurred at a pressure of 1bar measured on the bladder wall using a pressure probe. The closing force of the cuff was approx. 0·7N. No difference in tissue structure and organization of the urethra with and without artificial sphincter was observed. Conclusions: This device has several advantages compared to other urinary sphincters. It is easy to implant, has no hydraulic nature and reduces ischemic injury of the urethra by the alternance of urethral part compressed. Proof of concept in vivo has been demonstrated. Other studies are planned to determine long-term outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Our objective was to evaluate procalcitonin (PCT) and C-reactive protein (CRP) as predictors of a pneumococcal etiology in community-acquired pneumonia (CAP) in hospitalized children. METHODS: Children requiring hospitalization for CAP were prospectively enrolled. The following indices were determined: antibodies against pneumococcal surface proteins (anti-PLY, pneumococcal histidine triad D, pneumococcal histidine triad E, LytB and pneumococcal choline-binding protein A), viral serology, nasopharyngeal cultures and polymerase chain reaction for 13 respiratory viruses, blood pneumococcal polymerase chain reaction, pneumococcal urinary antigen, PCT and CRP. Presumed pneumococcal CAP (P-CAP) was defined as a positive blood culture or polymerase chain reaction for Streptococcus pneumoniae or as a pneumococcal surface protein seroresponse (≥2-fold increase). RESULTS: Seventy-five patients were included from which 37 (49%) met the criteria of P-CAP. Elevated PCT and CRP values were strongly associated with P-CAP with odds ratios of 23 (95% confidence interval: 5-117) for PCT and 19 (95% confidence interval: 5-75) for CRP in multivariate analysis. The sensitivity was 94.4% for PCT (cutoff: 1.5 ng/mL) and 91.9% for CRP (cutoff: 100 mg/L). A value≤0.5 ng/mL of PCT ruled out P-CAP in >90% of cases (negative likelihood ratio: 0.08). Conversely, a PCT value≥1.5 ng/mL associated with a positive pneumococcal urinary antigen had a diagnostic probability for P-CAP of almost 80% (positive likelihood ratio: 4.59). CONCLUSIONS: PCT and CRP are reliable predictors of P-CAP. Low cutoff values of PCT allow identification of children at low risk of P-CAP. The association of elevated PCT or CRP with a positive pneumococcal urinary antigen is a strong predictor of P-CAP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Hyperoxaluria is a major risk factor for kidney stone formation. Although urinary oxalate measurement is part of all basic stone risk assessment, there is no standardized method for this measurement. METHODS: Urine samples from 24-h urine collection covering a broad range of oxalate concentrations were aliquoted and sent, in duplicates, to six blinded international laboratories for oxalate, sodium and creatinine measurement. In a second set of experiments, ten pairs of native urine and urine spiked with 10 mg/L of oxalate were sent for oxalate measurement. Three laboratories used a commercially available oxalate oxidase kit, two laboratories used a high-performance liquid chromatography (HPLC)-based method and one laboratory used both methods. RESULTS: Intra-laboratory reliability for oxalate measurement expressed as intraclass correlation coefficient (ICC) varied between 0.808 [95% confidence interval (CI): 0.427-0.948] and 0.998 (95% CI: 0.994-1.000), with lower values for HPLC-based methods. Acidification of urine samples prior to analysis led to significantly higher oxalate concentrations. ICC for inter-laboratory reliability varied between 0.745 (95% CI: 0.468-0.890) and 0.986 (95% CI: 0.967-0.995). Recovery of the 10 mg/L oxalate-spiked samples varied between 8.7 ± 2.3 and 10.7 ± 0.5 mg/L. Overall, HPLC-based methods showed more variability compared to the oxalate oxidase kit-based methods. CONCLUSIONS: Significant variability was noted in the quantification of urinary oxalate concentration by different laboratories, which may partially explain the differences of hyperoxaluria prevalence reported in the literature. Our data stress the need for a standardization of the method of oxalate measurement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Uncomplicated urinary tract infections are commonly encountered in primary care and frequently lead to empirical antibiotic prescriptions. The development of antibiotic resistance in the community explains treatment failures observed with commonly-prescribed drugs such as quinolones and co-trimoxazole. This article describes the epidemiology of antibiotic resistance among pathogens causing uncomplicated urinary tract infections and the consequences in terms of recommendations for empirical antibiotic therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Few data for normal urinary oxalate (Ox) and calcium (Ca) excretion related both to gestational age and nutritional factors have been reported in preterm or term infants. We therefore determined the molar Ox and Ca to creatinine (Cr) ratios in spot urines from 64 preterm and 37 term infants aged 1-60 days, either fed formula or human milk (HM). Only vitamin D was supplemented; renal or metabolic diseases were excluded. Urinary Ox/Cr ratio was higher in preterm than in term infants, both when formula fed (1st month 253 vs. 180 mmol/mol and 2nd month 306 vs. 212 mmol/mol; P<0.05) or HM fed (206 vs. 169 mmol/ mol and 283* vs. 232 mmol/mol; *P<0.05). Ox/Cr was also higher in formula- than HM-fed preterm infants. The ratio increased during the first 2 months of life irrespective of nutrition. Urinary Ca/Cr ratio was comparable in all groups during the 1st month of life, except for a lower (P < 0.05) value in term infants fed HM (0.10 mol/mol). It increased in all groups during the 2nd month of life, being highest in HM-fed preterm infants (1.86 mol/mol). In conclusion, urinary Ox and Ca excretion is influenced by both gestational age and nutrient intake in preterm and term infants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbon isotope ratio (CIR) analysis has been routinely and successfully used in sports drug testing for many years to uncover the misuse of endogenous steroids. One limitation of the method is the availability of steroid preparations exhibiting CIRs equal to endogenous steroids. To overcome this problem, hydrogen isotope ratios (HIR) of endogenous urinary steroids were investigated as a potential complement; results obtained from a reference population of 67 individuals are presented herein. An established sample preparation method was modified and improved to enable separate measurements of each analyte of interest where possible. From the fraction of glucuronidated steroids; pregnanediol, 16-androstenol, 11-ketoetiocholanolone, androsterone (A), etiocholanolone (E), dehydroepiandrosterone (D), 5α- and 5β-androstanediol, testosterone and epitestosterone were included. In addition, sulfate conjugates of A, E, D, epiandrosterone and 17α- and 17β-androstenediol were considered and analyzed after acidic solvolysis. The obtained results enabled the calculation of the first reference-population-based thresholds for HIR of urinary steroids that can readily be applied to routine doping control samples. Proof-of-concept was accomplished by investigating urine specimens collected after a single oral application of testosterone-undecanoate. The HIR of most testosterone metabolites were found to be significantly influenced by the exogenous steroid beyond the established threshold values. Additionally, one regular doping control sample with an extraordinary testosterone/epitestosterone ratio of 100 without suspicious CIR was subjected to the complementary methodology of HIR analysis. The HIR data eventually provided evidence for the exogenous origin of urinary testosterone metabolites. Despite further investigations on HIR being advisable to corroborate the presented reference-population-based thresholds, the developed method proved to be a new tool supporting modern sports drug testing procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Exposure to urinary catheters is considered the most important risk factor for healthcare-associated urinary tract infection (UTI) and is associated with significant morbidity and substantial extra-costs. In this study, we assessed the impact of urinary catheterisation (UC) on symptomatic healthcare-associated UTI among hospitalized patients. METHODS: A nationwide period prevalence survey of healthcare-associated infections was conducted during 1 May to 30 June 2004 in 49 Swiss hospitals and included 8169 adult patients (4313 female; 52.8%) hospitalised in medical, surgical, intermediate, and intensive care wards. Additional data were collected on exposure to UC to investigate factors associated with UTI among hospitalised adult patients exposed and non-exposed to UC. RESULTS: 1917 (23.5%) patients were exposed to UC within the week prior to survey day; 126 (126/8169; 1.5%) developed UTI. Exposure to UC preceded UTI only in 73 cases (58%). By multivariate logistic regression analysis, UTI was independently associated with exposure to UC (odds ratio [OR], 3.9 [95% CI, 2.6-5.9]), female gender (OR, 2.1 [95% CI, 1.4-3.1]), an American Society of Anesthesiologists' score > 2 points (OR, 3.2 [95% CI, 1.1-9.4], and prolonged hospital stay >20 days (OR, 1.9 [95% CI, 1.4-3.2]. Further analysis showed that the only significant factor for UTI with exposure to UC use was prolonged hospital stay >40 days (OR, 2.9 [95% CI, 1.3-6.1], while female gender only showed a tendency (OR, 1.6 [95% CI, 1.0-2.7]. In the absence of exposure to UC, the only significant risk factor for UTI was female gender (OR, 3.3 [95% CI, 1.7-6.5]). CONCLUSIONS: Exposure to UC was the most important risk factor for symptomatic healthcare-associated UTI, but only concerned about half of all patients with UTI. Further investigation is warranted to improve overall infection control strategies for UTI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate the renal function outcome in children with unilateral hydronephrosis and urinary flow impairment at the pelviureteral junction with respect to the therapeutic strategy. METHODS: We retrospectively selected 45 children with iodine-123-hippuran renography performed at diagnosis and after 3 or more years of follow-up. All children had bilateral nonobstructive pattern findings on diuretic renography at follow-up. Eleven children were treated conservatively, and 34 underwent unilateral pyeloplasty. Split and individual renal function, measured by an accumulation index, was computed from background-corrected renograms for the affected and contralateral kidneys at diagnosis and the follow-up examination. RESULTS: Of 11 children treated conservatively, 9 had normal bilateral function at diagnosis, all had reached normal function at follow-up. Of the 34 operated kidneys, 12 (38%) had initially normal function that remained normal at the follow-up examination, and 22 had impaired function that had normalized at the follow-up examination in 15 (68%). The function of the contralateral kidneys was increased in 5 of 8 children with persistently abnormal affected kidneys. Pyeloplasty was performed in 23 children (68%) and 11 children (32%) younger and older than 1 year, respectively. The function of the affected kidneys increased in both groups, but normalization occurred only in the younger children. CONCLUSIONS: Of the children selected for conservative treatment, 82% had normal bilateral renal function at diagnosis that was normal in all at the follow-up examination. Of the children treated surgically, 65% had initially impaired function of the affected kidney that improved in 87% after pyeloplasty. Normalization of function was observed only in children who were younger than 1 year old at surgery. Persistently low function of the affected kidney was compensated for by the contralateral one regardless of the age at surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Toxicokinetic modeling is a useful tool to describe or predict the behavior of a chemical agent in the human or animal organism. A general model based on four compartments was developed in a previous study in order to quantify the effect of human variability on a wide range of biological exposure indicators. The aim of this study was to adapt this existing general toxicokinetic model to three organic solvents, which were methyl ethyl ketone, 1-methoxy-2-propanol and 1,1,1,-trichloroethane, and to take into account sex differences. We assessed in a previous human volunteer study the impact of sex on different biomarkers of exposure corresponding to the three organic solvents mentioned above. Results from that study suggested that not only physiological differences between men and women but also differences due to sex hormones levels could influence the toxicokinetics of the solvents. In fact the use of hormonal contraceptive had an effect on the urinary levels of several biomarkers, suggesting that exogenous sex hormones could influence CYP2E1 enzyme activity. These experimental data were used to calibrate the toxicokinetic models developed in this study. Our results showed that it was possible to use an existing general toxicokinetic model for other compounds. In fact, most of the simulation results showed good agreement with the experimental data obtained for the studied solvents, with a percentage of model predictions that lies within the 95% confidence interval varying from 44.4 to 90%. Results pointed out that for same exposure conditions, men and women can show important differences in urinary levels of biological indicators of exposure. Moreover, when running the models by simulating industrial working conditions, these differences could even be more pronounced. In conclusion, a general and simple toxicokinetic model, adapted for three well known organic solvents, allowed us to show that metabolic parameters can have an important impact on the urinary levels of the corresponding biomarkers. These observations give evidence of an interindividual variablity, an aspect that should have its place in the approaches for setting limits of occupational exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Urinary incontinence can be treated by endoscopic injection of bulking agents, however, no optimal therapeutic effect has been achieved upon this treatment yet. In the present study, the development of a injectable poly(acrylonitrile) hydrogel paste is described, and its efficacy and histological behavior, once injected into the submucosal space of the minipig bladder, are evaluated. A device was developed to mix poly(acrylonitrile) hydrogel powder with glycerin, used as carrier, prior to injection into the submucosal space of the bladder. Several paste deposits, depending on the size of the bladder, were injected per animal. The implants were harvested at days 7, 14, 21, 28, 84 and 168 and analyzed morphologically and by histology. The persistence of the implants was demonstrated. However, at later time points the implants were split up and surrounded by granulomatous tissue, which was gradually replaced by histiocytes and adipocytes. Transitory focal urothelial metaplasia was observed only at day 7 and moderate foreign body reaction was detected predominantly between the second and fifth week. This study demonstrated the feasibility to develop an injectable paste of poly(acrylonitrile) hydrogel thought to provide the expected bulking effect, necessary for the treatment of urinary incontinence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The AMS 800 is the current artifi cial urinary sphincter (AUS) forincontinence due to intrinsic sphincter defi ciency. Despite good clinical results,technical failures inherent to the hydraulic mechanism or urethral ischemicinjury contribute to revisions up to 60%. We are developing an electronic AUS,called ARTUS to overcome the rigors of AMS. The objective of this study wasto evaluate the technical effi cacy and tissue tolerance of the ARTUS systemin an animal model.Methods: The ARTUS is composed by three parts: thecontractile unit, a series of rings and an integrated microprocessor. The contractileunit is made of Nitinol fi bers. The rings are placed around the urethrato control the fl ow of urine by squeezing the urethra. They work in a sequentialalternative mode and are controlled by a microprocessor. In the fi rst phase athree-rings device was used while in the second phase a two-rings ARTUS wasused. The device was implanted in 14 sheep divided in two groups of six andeight animals for study purpose. The fi rst group aimed at bladder leak pointpressure (BLPP) measurement and validation of the animal model; the secondgroup aimed at verifying midterm tissue tolerance by explants at twelve weeks.General animal tolerance was also evaluated.Results: The ARTUS systemimplantation was uneventful. When the system was activated, the BLPP wasmeasured at 1.038 ± 0.044 bar (mean ± SD). Urethral tissue analysis did notshow signifi cant morphological changes. No infection and no sign of discomfortwere noted in animals at 12 weeks.Conclusions: The ARTUS proved to beeffective in continence achievement in this study. Histological results supportour idea that a sequential alternative mode can avoid urethral atrophy andischemia. Further technical developments are needed to verify long-termoutcome and permit human use.