146 resultados para spherical diffusion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis, I examine the diffusion process for a complex medical technology, the PET scanner, in two different health care systems, one of which is more market-oriented (Switzerland) and the other more centrally managed by a public agency (Quebec). The research draws on institutional and socio-political theories of the diffusion of innovations to examine how institutional contexts affect processes of diffusion. I find that diffusion proceeds more rapidly in Switzerland than in Quebec, but that processes in both jurisdictions are characterized by intense struggles among providers and between providers and public agencies. I show that the institutional environment influences these processes by determining the patterns of material resources and authority available to actors in their struggles to strategically control the technology, and by constituting the discursive resources or institutional logics on which actors may legitimately draw in their struggles to give meaning to the technology in line with their interests and values. This thesis illustrates how institutional structures and meanings manifest themselves in the context of specific decisions within an organizational field, and reveals the ways in which governance structures may be contested and realigned when they conflict with interests that are legitimized by dominant institutional logics. It is argued that this form of contestation and readjustment at the margins constitutes one mechanism by which institutional frameworks are tested, stretched and reproduced or redefined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a method for segmenting white matter tracts from high angular resolution diffusion MR. images by representing the data in a 5 dimensional space of position and orientation. Whereas crossing fiber tracts cannot be separated in 3D position space, they clearly disentangle in 5D position-orientation space. The segmentation is done using a 5D level set method applied to hyper-surfaces evolving in 5D position-orientation space. In this paper we present a methodology for constructing the position-orientation space. We then show how to implement the standard level set method in such a non-Euclidean high dimensional space. The level set theory is basically defined for N-dimensions but there are several practical implementation details to consider, such as mean curvature. Finally, we will show results from a synthetic model and a few preliminary results on real data of a human brain acquired by high angular resolution diffusion MRI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectifs : Le coefficient de diffusion apparente (ADC) est utilisé pour le suivi des lésions hépatiques malignes traitées. Cependant, l'ADC est généralement mesuré dans la lésion entière, alors que cela devrait être réalisé dans la zone la plus restreinte (ZLPR), cette dernière représentant potentiellement du résidu tumoral. Notre objectif était d'évaluer la variabilité inter/intraobservateur de l'ADC dans la tumeur entière et dans la ZLPR. Matériels et méthodes : Quarante patients traités par chimioembolisation ou radiofréquence ont été évalués. Après consensus, deux lecteurs ont indépendamment mesuré l'ADC de la lésion entière et de la ZLPR. Les mêmes mesures ont été répétées deux semaines plus tard. Le test de Spearman et la méthode de Bland-Altman ont été utilisées. Résultats : La corrélation interobservateur de l'ADC dans la lésion entière et dans la ZLPR était de 0,962 et de 0,884. La corrélation intraobservateur était de 0,992 et de 0,979, respectivement. Les limites de variabilité interobservateur (mm2/sec*10 - 3) étaient entre -0,25/+0,28 dans la lésion entière et entre -0,51/+0,46 dans la ZLPR. Les limites de variabilité intraobservateur étaient respectivement : -0,25/+0,24 et -0,43/+0,47. Conclusion : La corrélation inter/intraobservateur dans les mesures d'ADC est bonne. Toutefois, une variabilité limitée existe et doit être considérée lors de l'interprétation des valeurs d'ADC des tumeurs hépatiques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les méthodes de recherche qualitative en psychologie connaissent une diffusion de plus en plus importante, soutenue notamment par le développement phénoménal des réseaux de l'Internet. Nos investigations mettent en lumière diverses catégories de sites liés à la recherche qualitative, pour la plupart issues de grandes institutions nord-américaines. Cependant, la présence d'autant d'informa- tions sur le Web pose la question de la crédibilité des sites disponibles et de leur visibilité : en effet, si une certaine qualité peut être attendue des sites émanant d'institutions officielles, en termes de qualité d'information et de facilité d'accès, en revanche, il s'avère plus difficile d'évaluer certaines pages se réclamant pourtant de la recherche scientifique. Dans cet article, nous présentons quelques sites et liens Internet susceptibles de séduire les chercheurs intéressés par les méthodes qualitatives en psychologie.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article studies the diffusion of the main institutional feature of regulatory capitalism, namely, independent regulatory agencies. While only a few such authorities existed in Europe in the early 1980s, by the end of the twentieth century they had spread impressively across countries and sectors. The analysis finds that three classes of factors (bottom-up, top-down, and horizontal) explain this trend. First, the establishment of independent regulatory agencies was an attempt to improve credible commitment capacity when liberalizing and privatizing utilities and to alleviate the political uncertainty problem, namely, the risk to a government that its policies will be changed when it loses power. Second, Europeanization favored the creation of independent regulators. Third, individual decisions were interdependent, as governments were influenced by the decisions of others in an emulation process where the symbolic properties of independent regulators mattered more than the functions they performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, it has been proposed that drug permeation is essentially carrier-mediated only and that passive lipoidal diffusion is negligible. This opposes the prevailing hypothesis of drug permeation through biological membranes, which integrates the contribution of multiple permeation mechanisms, including both carrier-mediated and passive lipoidal diffusion, depending on the compound's properties, membrane properties, and solution properties. The prevailing hypothesis of drug permeation continues to be successful for application and prediction in drug development. Proponents of the carrier-mediated only concept argue against passive lipoidal diffusion. However, the arguments are not supported by broad pharmaceutics literature. The carrier-mediated only concept lacks substantial supporting evidence and successful applications in drug development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectifs: Etudier l'utilité de DWI dans l'échinococcose alveolaire (EA) hépatique. Matériels et méthodes: Dix-sept patients (10 hommes, âge moyen 64.3) avec 55 lésions hépatiques ont été examinés par IRM. La sémiologie des lésions a été étudiée après classification selon Kodama. Les coefficients apparent de diffusion (ADCmax, ADCmin, ADCtot) ont été mesurés. Résultats: Trois lésions de Kodama de type 1, 13 de type 2, 15 de type 3, 3 de type 4, et 21 de type 5. L'ADCtot des lésions mesurait 1.23±0.18 x 10-3 mm2/s. L'ADCtot de Kodama type 1, 2, 3, 4 et 5 mesuraient 1.97±0.27, 1.66±0.13, 1.73±0.12, 1.15±0.27 et 1.76±0.10 x 10-3 mm2/s, respectivement. Il n'y avait pas de différence significative de l'ADCtot entre les types (p=0.25) hormis le type 4 qui représente une lésion solide (p=0.035). Conclusion: Les valeurs d'ADC des lésions d'EA ne se révèlent pas utiles pour différencier les différents types selon Kodama, hormis pour le type 4 ce qui suggère la présence d'une composante solide. Celles-ci sont relativement basses comparées à d'autres lésions kystiques hépatiques, ce qui peut aider à suggérer le diagnostic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Diffusion-weighted magnetic resonance imaging (MRI) is increasingly being used for assessing the treatment succes in oncology, but the real clinical value needs to evaluated by comparison with other, already established, metabolic imaging techniques. PURPOSE: To prospectively evaluate the clinical potential of diffusion-weighted MRI with apparent diffusion coefficient (ADC) mapping for gastrointestinal stromal tumor (GIST) response to targeted therapy compared with 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT). MATERIAL AND METHODS: Eight patients (mean age, 56 ± 11 years) known to have metastatic GIST underwent 18F-FDG PET/CT and MRI (T1Gd, DWI [b = 50,300,600], ADC mapping) simultaneously, before and after change in targeted therapy. MR and PET/CT examinations were first analyzed blindly. Second, PET/CT images were co-registered with T1Gd-MR images for lesion detection. Only 18F-FDG avid lesions were considered. Maximum standardized uptake value (SUVmax) and the corresponding minimum ADCmin were measured for the six largest lesions per patient, if any, on baseline and follow-up examinations. The relationship between changes in SUVmax and ADCmin was analyzed (Spearman's correlation). RESULTS: Twenty-four metastases (12 hepatic, 12 extra-hepatic) were compared on PET/CT and MR images. SUVmax decreased from 7.7 ± 8.1 g/mL to 5.5 ± 5.4 g/mL (P = 0.20), while ADCmin increased from 1.2 ± 0.3 × 10(-3)mm(2)/s to 1.5 ± 0.3 × 10(-3)mm(2)/s (P = 0.0002). There was a significant association between changes in SUVmax and ADCmin (rho = - 0.62, P = 0.0014), but not between changes in lesions size (P = 0.40). CONCLUSION: Changes in ADCmin correlated with the response of 18F-FDG avid GIST to targeted therapy. Thus, diffusion-weighted MRI may represent a radiation-free alternative for follow-up treatment for metastatic GIST patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methods are presented to map complex fiber architectures in tissues by imaging the 3D spectra of tissue water diffusion with MR. First, theoretical considerations show why and under what conditions diffusion contrast is positive. Using this result, spin displacement spectra that are conventionally phase-encoded can be accurately reconstructed by a Fourier transform of the measured signal's modulus. Second, studies of in vitro and in vivo samples demonstrate correspondence between the orientational maxima of the diffusion spectrum and those of the fiber orientation density at each location. In specimens with complex muscular tissue, such as the tongue, diffusion spectrum images show characteristic local heterogeneities of fiber architectures, including angular dispersion and intersection. Cerebral diffusion spectra acquired in normal human subjects resolve known white matter tracts and tract intersections. Finally, the relation between the presented model-free imaging technique and other available diffusion MRI schemes is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical use of the Stejskal-Tanner diffusion weighted images is hampered by the geometric distortions that result from the large residual 3-D eddy current field induced. In this work, we aimed to predict, using linear response theory, the residual 3-D eddy current field required for geometric distortion correction based on phantom eddy current field measurements. The predicted 3-D eddy current field induced by the diffusion-weighting gradients was able to reduce the root mean square error of the residual eddy current field to ~1 Hz. The model's performance was tested on diffusion weighted images of four normal volunteers, following distortion correction, the quality of the Stejskal-Tanner diffusion-weighted images was found to have comparable quality to image registration based corrections (FSL) at low b-values. Unlike registration techniques the correction was not hindered by low SNR at high b-values, and results in improved image quality relative to FSL. Characterization of the 3-D eddy current field with linear response theory enables the prediction of the 3-D eddy current field required to correct eddy current induced geometric distortions for a wide range of clinical and high b-value protocols.