205 resultados para regional perfusion
Predictors and accuracy of abnormal CT perfusion in 1296 consecutive acute ischemic stroke patients.
Resumo:
BACKGROUND: Contrast-enhanced ultrasonography (CEUS) is a novel imaging technique that is safe and applicable on the bedside. Recent developments seem to enable CEUS to quantify organ perfusion. We performed an exploratory study to determine the ability of CEUS to detect changes in renal perfusion and to correlate them with effective renal plasma flow. METHODS: CEUS with destruction-refilling sequences was studied in 10 healthy subjects, at baseline and during infusion of angiotensin II (AngII) at low (1 ng/kg/min) and high dose (3 ng/kg/min) and 1 h after oral captopril (50 mg). Perfusion index (PI) was obtained and compared with the effective renal plasma flow (ERPF) obtained by parallel para-aminohippurate (PAH) clearance. RESULTS: Median PI decreased from 188.6 (baseline) to 100.4 with low-dose AngII (-47%; P < 0.02) and to 66.1 with high-dose AngII (-65%; P < 0.01) but increased to 254.7 with captopril (+35%; P > 0.2). These changes parallelled those observed with ERPF, which changed from a median of 672.1 mL/min (baseline) to 572.3 (low-dose AngII, -15%, P < 0.05) and to 427.2 (high-dose AngII, -36%, P < 0.001) and finally 697.1 (captopril, +4%, P < 0.02). CONCLUSIONS: This study demonstrates that CEUS is able to detect changes in human renal cortical microcirculation as induced by AngII infusion and/or captopril administration. The changes in perfusion indices parallel those in ERPF as obtained by PAH clearance.
Resumo:
Debris flow susceptibility mapping at a regional scale has been the subject of various studies. The complexity of the phenomenon and the variability of local controlling factors limit the use of process-based models for a first assessment. GISbased approaches associating an automatic detection of the source areas and a simple assessment of the debris flow spreading may provide a substantial basis for a preliminary susceptibility assessment at the regional scale. The use of a digital elevation model, with a 10 m resolution, for the Canton de Vaud territory (Switzerland), a lithological map and a land use map, has allowed automatic identification of the potential source areas. The spreading estimates are based on basic probabilistic and energy calculations that allow to define the maximal runout distance of a debris flow.
Resumo:
Unlike fragmental rockfall runout assessments, there are only few robust methods to quantify rock-mass-failure susceptibilities at regional scale. A detailed slope angle analysis of recent Digital Elevation Models (DEM) can be used to detect potential rockfall source areas, thanks to the Slope Angle Distribution procedure. However, this method does not provide any information on block-release frequencies inside identified areas. The present paper adds to the Slope Angle Distribution of cliffs unit its normalized cumulative distribution function. This improvement is assimilated to a quantitative weighting of slope angles, introducing rock-mass-failure susceptibilities inside rockfall source areas previously detected. Then rockfall runout assessment is performed using the GIS- and process-based software Flow-R, providing relative frequencies for runout. Thus, taking into consideration both susceptibility results, this approach can be used to establish, after calibration, hazard and risk maps at regional scale. As an example, a risk analysis of vehicle traffic exposed to rockfalls is performed along the main roads of the Swiss alpine valley of Bagnes.
Resumo:
INTRODUCTION: Intravoxel incoherent motion (IVIM) imaging is an MRI perfusion technique that uses a diffusion-weighted sequence with multiple b values and a bi-compartmental signal model to measure the so-called pseudo-diffusion of blood caused by its passage through the microvascular network. The goal of the current study was to assess the feasibility of IVIM perfusion fraction imaging in patients with acute stroke. METHODS: Images were collected in 17 patients with acute stroke. Exclusion criteria were onset of symptoms to imaging >5 days, hemorrhagic transformation, infratentorial lesions, small lesions <0.5 cm in minimal diameter and hemodynamic instability. IVIM imaging was performed at 3 T, using a standard spin-echo Stejskal-Tanner pulsed gradients diffusion-weighted sequence, using 16 b values from 0 to 900 s/mm(2). Image quality was assessed by two radiologists, and quantitative analysis was performed in regions of interest placed in the stroke area, defined by thresholding the apparent diffusion coefficient maps, as well as in the contralateral region. RESULTS: IVIM perfusion fraction maps showed an area of decreased perfusion fraction f in the region of decreased apparent diffusion coefficient. Quantitative analysis showed a statistically significant decrease in both IVIM perfusion fraction f (0.026 ± 0.019 vs. 0.056 ± 0.025, p = 2.2 · 10(-6)) and diffusion coefficient D compared with the contralateral side (3.9 ± 0.79 · 10(-4) vs. 7.5 ± 0.86 · 10(-4) mm(2)/s, p = 1.3 · 10(-20)). CONCLUSION: IVIM perfusion fraction imaging is feasible in acute stroke. IVIM perfusion fraction is significantly reduced in the visible infarct. Further studies should evaluate the potential for IVIM to predict clinical outcome and treatment response.
Resumo:
Digital holographic microscopy (DHM) allows optical-path-difference (OPD) measurements with nanometric accuracy. OPD induced by transparent cells depends on both the refractive index (RI) of cells and their morphology. This Letter presents a dual-wavelength DHM that allows us to separately measure both the RI and the cellular thickness by exploiting an enhanced dispersion of the perfusion medium achieved by the utilization of an extracellular dye. The two wavelengths are chosen in the vicinity of the absorption peak of the dye, where the absorption is accompanied by a significant variation of the RI as a function of the wavelength.
Resumo:
RESUME Les changements locaux de la température à la surface de la peau humaine ont une influence importante sur sa perfusion. La chaleur augmente localement le flux sanguin cutané, mais les mécanismes et les médiateurs de cette réponse (réponse thermique d'hyperémie) sont incomplètement élucidés. Dans la présente étude, nous avons examiné la relation possible entre la réponse thermique d'hyperémie, les récepteurs cholinergiques muscariniques et la production des prostaglandines vasodilatatrices. Chez 13 sujets de sexe masculin en bonne santé âgés entre 20 et 30 ans, une chambre métallique (contenant de l'eau) dont la température peut être contrôlée, a été placée sur la face palmaire de leur avant-bras et utilisée pour augmenter la température de surface de 34 à 41°C. L'hyperémie cutanée consécutive a été enregistrée par l'intermédiaire d'un scanner laser-Doppler. Dans une expérience, chacun des 8 sujets a reçu un bolus i.v. de glycopyrolate (agent antimuscarinique) (4 µg/kg) lors d'une visite et de NaCl 0,9% lors de l'autre visite. La réponse thermique d'hyperémie a été déterminée dans l'heure suivant les injections. Les glycopyrolate a efficacement empêché la vasodilation des micro-vaisseaux cutanés induite par iontophorèse d'acétylcholine mais n'a pas influencé la réponse thermique d'hyperémie. Dans une deuxième expérience entreprise avec 5 autres sujets 1 g d'aspirine (inhibiteur de la cyclooxygénase) administrée oralement a totalement supprimé la vasodilatation induite dans la peau par le courant anodique, sans modifier la réponse thermique d'hyperémie. La présente étude confirme l'absence de stimulation des récepteurs muscariniques et la production de prostaglandines vaso-dilatatrices dans la vasodilatation induite chez l'homme par réchauffement local de la peau de l'avant-bras. ABSTRACT Local changes in surface temperature have a powerful influence on the perfusion of human skin. Heating increases local skin blood flow (SkBF), but the mechanisms and mediators of this response (thermal hyperemia response) are incompletely elucidated. In the present study, we examined the possible dependence of the thermal hyperemia response on stimulation of muscarinic cholinergic receptors and on production of vasodilator prostanoids. In 13 male healthy subjects aged 20 - 30 years, a temperature- controlled chamber was positioned on the volar face of one forearm and used to raise surface temperature from 34to41°C. The time-course of the resulting thermal hyperemia response was recorded with a laser-Doppler imager. In one experiment, each of 8 subjects received an i.v. bolus of the antimuscarinic agent glycopyrrolate (4µg/kg) on one visit and saline on the other. The thermal hyperemia response was determined within the hour following the injections. Glycopyrrolate effectively inhibited the skin vasodilation induced by iontophoresis of acetylcholine, but did not influence the thermal hyperemia response. In a second experiment conducted in 5 other subjects, 1 gram of the cyclooxygenase inhibitor aspirin administered orally totally abolished the vasodilation induced in the skin by anodal current, but also failed to modify the thermal hyperemia response. The present study excludes the stimulation of muscarinic receptors and the production of vasodilator prostaglandins as essential and nonredundant mechanisms for the vasodilation induced by local heating in human forearm skin.
Resumo:
The purpose of this study was to determine the prognostic accuracy of perfusion computed tomography (CT), performed at the time of emergency room admission, in acute stroke patients. Accuracy was determined by comparison of perfusion CT with delayed magnetic resonance (MR) and by monitoring the evolution of each patient's clinical condition. Twenty-two acute stroke patients underwent perfusion CT covering four contiguous 10mm slices on admission, as well as delayed MR, performed after a median interval of 3 days after emergency room admission. Eight were treated with thrombolytic agents. Infarct size on the admission perfusion CT was compared with that on the delayed diffusion-weighted (DWI)-MR, chosen as the gold standard. Delayed magnetic resonance angiography and perfusion-weighted MR were used to detect recanalization. A potential recuperation ratio, defined as PRR = penumbra size/(penumbra size + infarct size) on the admission perfusion CT, was compared with the evolution in each patient's clinical condition, defined by the National Institutes of Health Stroke Scale (NIHSS). In the 8 cases with arterial recanalization, the size of the cerebral infarct on the delayed DWI-MR was larger than or equal to that of the infarct on the admission perfusion CT, but smaller than or equal to that of the ischemic lesion on the admission perfusion CT; and the observed improvement in the NIHSS correlated with the PRR (correlation coefficient = 0.833). In the 14 cases with persistent arterial occlusion, infarct size on the delayed DWI-MR correlated with ischemic lesion size on the admission perfusion CT (r = 0.958). In all 22 patients, the admission NIHSS correlated with the size of the ischemic area on the admission perfusion CT (r = 0.627). Based on these findings, we conclude that perfusion CT allows the accurate prediction of the final infarct size and the evaluation of clinical prognosis for acute stroke patients at the time of emergency evaluation. It may also provide information about the extent of the penumbra. Perfusion CT could therefore be a valuable tool in the early management of acute stroke patients.
Resumo:
Purpose: To evaluate the sensitivity of the perfusion parameters derived from Intravoxel Incoherent Motion (IVIM) MR imaging to hypercapnia-induced vasodilatation and hyperoxygenation-induced vasoconstriction in the human brain. Materials and Methods: This study was approved by the local ethics committee and informed consent was obtained from all participants. Images were acquired with a standard pulsed-gradient spin-echo sequence (Stejskal-Tanner) in a clinical 3-T system by using 16 b values ranging from 0 to 900 sec/mm(2). Seven healthy volunteers were examined while they inhaled four different gas mixtures known to modify brain perfusion (pure oxygen, ambient air, 5% CO(2) in ambient air, and 8% CO(2) in ambient air). Diffusion coefficient (D), pseudodiffusion coefficient (D*), perfusion fraction (f), and blood flow-related parameter (fD*) maps were calculated on the basis of the IVIM biexponential model, and the parametric maps were compared among the four different gas mixtures. Paired, one-tailed Student t tests were performed to assess for statistically significant differences. Results: Signal decay curves were biexponential in the brain parenchyma of all volunteers. When compared with inhaled ambient air, the IVIM perfusion parameters D*, f, and fD* increased as the concentration of inhaled CO(2) was increased (for the entire brain, P = .01 for f, D*, and fD* for CO(2) 5%; P = .02 for f, and P = .01 for D* and fD* for CO(2) 8%), and a trend toward a reduction was observed when participants inhaled pure oxygen (although P > .05). D remained globally stable. Conclusion: The IVIM perfusion parameters were reactive to hyperoxygenation-induced vasoconstriction and hypercapnia-induced vasodilatation. Accordingly, IVIM imaging was found to be a valid and promising method to quantify brain perfusion in humans. © RSNA, 2012.
Resumo:
A technique for fast imaging of regional myocardial function using a spiral acquisition in combination with strain-encoded (SENC) magnetic resonance imaging (MRI) is presented in this paper. This technique, which is termed fast-SENC, enables scan durations as short as a single heartbeat. A reduced field of view (FOV) without foldover artifacts was achieved by localized SENC, which selectively excited the region around the heart. The two images required for SENC imaging (low- and high-tuning) were acquired in an interleaved fashion throughout the cardiac cycle to further shorten the scan time. Regional circumferential contraction and longitudinal shortening of both the left ventricle (LV) and right ventricle (RV) were examined in long- and short-axis views, respectively. The in vivo results obtained from five human subjects and five infarcted dogs are presented. The results of the fast-SENC technique in a single heartbeat acquisition were comparable to those obtained by conventional SENC in a long acquisition time. Therefore, fast-SENC may prove useful for imaging during stress or arrhythmia.