48 resultados para pacemaker


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: We aim to explore how health surrogates of patients with dementia proceed in decision making, which considerations are decisive, and whether family surrogates and professional guardians decide differently. METHODS: We conducted an experimental vignette study using think aloud protocol analysis. Thirty-two family surrogates and professional guardians were asked to decide on two hypothetical case vignettes, concerning a feeding tube placement and a cardiac pacemaker implantation in patients with end-stage dementia. They had to verbalize their thoughts while deciding. Verbalizations were audio-recorded, transcribed, and analyzed according to content analysis. By experimentally changing variables in the vignettes, the impact of these variables on the outcome of decision making was calculated. RESULTS: Although only 25% and 31% of the relatives gave their consent to the feeding tube and pacemaker placement, respectively, 56% and 81% of the professional guardians consented to these life-sustaining measures. Relatives decided intuitively, referred to their own preferences, and focused on the patient's age, state of wellbeing, and suffering. Professional guardians showed a deliberative approach, relied on medical and legal authorities, and emphasized patient autonomy. Situational variables such as the patient's current behavior and the views of health care professionals and family members had higher impacts on decisions than the patient's prior statements or life attitudes. CONCLUSIONS: Both the process and outcome of surrogate decision making depend heavily on whether the surrogate is a relative or not. These findings have implications for the physician-surrogate relationship and legal frameworks regarding surrogacy. Copyright © 2011 John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Electrophysiological cardiac devices are increasingly used. The frequency of subclinical infection is unknown. We investigated all explanted devices using sonication, a method for detection of microbial biofilms on foreign bodies. METHODS AND RESULTS: Consecutive patients in whom cardiac pacemakers and implantable cardioverter/defibrillators were removed at our institution between October 2007 and December 2008 were prospectively included. Devices (generator and/or leads) were aseptically removed and sonicated, and the resulting sonication fluid was cultured. In parallel, conventional swabs of the generator pouch were performed. A total of 121 removed devices (68 pacemakers, 53 implantable cardioverter/defibrillators) were included. The reasons for removal were insufficient battery charge (n=102), device upgrading (n=9), device dysfunction (n=4), or infection (n=6). In 115 episodes (95%) without clinical evidence of infection, 44 (38%) grew bacteria in sonication fluid, including Propionibacterium acnes (n=27), coagulase-negative staphylococci (n=11), Gram-positive anaerobe cocci (n=3), Gram-positive anaerobe rods (n=1), Gram-negative rods (n=1), and mixed bacteria (n=1). In 21 of 44 sonication-positive episodes, bacterial counts were significant (>or=10 colony-forming units/mL of sonication fluid). In 26 sterilized controls, sonication cultures remained negative in 25 cases (96%). In 112 cases without clinical infection, conventional swab cultures were performed: 30 cultures (27%) were positive, and 18 (60%) were concordant with sonication fluid cultures. Six devices and leads were removed because of infection, growing Staphylococcus aureus, Streptococcus mitis, and coagulase-negative staphylococci in 6 sonication fluid cultures and 4 conventional swab cultures. CONCLUSIONS: Bacteria can colonize cardiac electrophysiological devices without clinical signs of infection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background- An elevated resting heart rate is associated with rehospitalization for heart failure and is a modifiable risk factor in heart failure patients. We aimed to examine the association between resting heart rate and incident heart failure in a population-based cohort study of healthy adults without pre-existing overt heart disease. Methods and Results- We studied 4768 men and women aged ≥55 years from the population-based Rotterdam Study. We excluded participants with prevalent heart failure, coronary heart disease, pacemaker, atrial fibrillation, atrioventricular block, and those using β-blockers or calcium channel blockers. We used extended Cox models allowing for time-dependent variation of resting heart rate along follow-up. During a median of 14.6 years of follow-up, 656 participants developed heart failure. The risk of heart failure was higher in men with higher resting heart rate. For each increment of 10 beats per minute, the multivariable adjusted hazard ratios in men were 1.16 (95% confidence interval, 1.05-1.28; P=0.005) in the time-fixed heart rate model and 1.13 (95% confidence interval, 1.02-1.25; P=0.017) in the time-dependent heart rate model. The association could not be demonstrated in women (P for interaction=0.004). Censoring participants for incident coronary heart disease or using time-dependent models to account for the use of β-blockers or calcium channel blockers during follow-up did not alter the results. Conclusions- Baseline or persistent higher resting heart rate is an independent risk factor for the development of heart failure in healthy older men in the general population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nitric oxide synthase (NOS) is strongly and transiently expressed in the developing heart but its function is not well documented. This work examined the role, either protective or detrimental, that endogenous and exogenous NO could play in the functioning of the embryonic heart submitted to hypoxia and reoxygenation. Spontaneously beating hearts isolated from 4-day-old chick embryos were either homogenized to determine basal inducible NOS (iNOS) expression and activity or submitted to 30 min anoxia followed by 100 min reoxygenation. The chrono-, dromo- and inotropic responses to anoxia/reoxygenation were determined in the presence of NOS substrate (L-arginine 10 mM), NOS inhibitor L-NIO (1-5 mM), or NO donor (DETA NONOate 10-100 microM). Myocardial iNOS was detectable by immunoblotting and its activity was specifically decreased by 53% in the presence of 5 mM L-NIO. L-Arginine, L-NIO and DETA NONOate at 10 microM had no significant effect on the investigated functional parameters during anoxia/reoxygenation. However, irrespective of anoxia/reoxygenation, DETA NONOate at 100 microM decreased ventricular shortening velocity by about 70%, and reduced atrio-ventricular propagation by 23%. None of the used drugs affected atrial activity and hearts of all experimental groups fully recovered at the end of reoxygenation. These findings indicate that (1) by contrast with adult heart, endogenously released NO plays a minor role in the early response of the embryonic heart to reoxygenation, (2) exogenous NO has to be provided at high concentration to delay postanoxic functional recovery, and (3) sinoatrial pacemaker cells are the less responsive to NO.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Heart failure and atrial fibrillation are the main problems in general cardiology. Our therapeutic reflections summarize new ideas in the treatment of theses pathologies but we will not forget importance of PCI. All these therapies have proven now the clinical benefit but also reduction in more morbidity and mortality. Cardiac resynchronisation therapy has shown promising results. The art of medicine to develop will be to better identify the patients benefiting from this therapy. Interventional cardiology is focusing on the acute coronary syndrome. Not only rapid intervention but also the stent technology allow significant modification of endothelial tissue reaction and therefore improve the general benefit for the patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Many physiological processes in organisms from bacteria to man are rhythmic, and some of these are controlled by self-sustained oscillators that persist in the absence of external time cues. Circadian clocks are perhaps the best characterized biological oscillators and they exist in virtually all light-sensitive organisms. In mammals, they influence nearly all aspects of physiology and behavior, including sleep-wake cycles, cardiovascular activity, endocrinology, body temperature, renal activity, physiology of the gastro-intestinal tract, and hepatic metabolism. The master pacemaker is located in the suprachiasmatic nuclei, two small groups of neurons in the ventral part of the hypothalamus. However, most peripheral body cells contain self-sustained circadian oscillators with a molecular makeup similar to that of SCN (suprachiasmatic nucleus) neurons. This organization implies that the SCN must synchronize countless subsidiary oscillators in peripheral tissues, in order to coordinate cyclic physiology. In this review, we will discuss some recent studies on the structure and putative functions of the mammalian circadian timing system, but we will also point out some apparent inconsistencies in the currently publicized model for rhythm generation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe a device made of artificial muscle for the treatment of end-stage heart failure as an alternative to current heart assist devices. The key component is a matrix of nitinol wires and aramidic fibers called Biometal muscle (BM). When heated electrically, it produces a motorless, smooth, and lifelike motion. The BM is connected to a carbon fiber scaffold, tightening the heart and providing simultaneous assistance to the left and right ventricles. A pacemaker-like microprocessor drives the contraction of the BM. We tested the device in a dedicated bench model of diseased heart. It generated a systolic pressure of 75 mm Hg and ejected a maximum of 330 ml/min, with an ejection fraction of 12%. The device required a power supply of 6 V, 250 mA. This could be the beginning of an era in which BMs integrate or replace the mechanical function of natural muscles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACT: INTRODUCTION: Dermatofibrosarcoma protuberans is a rare neoplasm of soft tissues and its location in the breast is extremely uncommon. Confusion is possible with other primary breast lesions. CASE PRESENTATION: A 75-year-old Caucasian woman presented with a mass in her left breast 21 years after being diagnosed with invasive ductal carcinoma of the right breast, treated by a right mastectomy and axillary dissection followed by radiotherapy and breast reconstruction. Mammography revealed a dish-shaped skin nodule formation in the upper outer quadrant of her left breast. Echography confirmed the presence of a lesion measuring 1.4 x 0.8 cm. Based on imaging, the diagnosis was a probable angiosarcoma. Due to the presence of a pacemaker for cardiac arrhythmia and full anticoagulation therapy for a pulmonary embolism, magnetic resonance imaging and a biopsy were not done. We proceeded directly to a quadrantectomy and the final diagnosis revealed a dermatofibrosarcoma protuberans, 1. 8 cm in its greatest microscopic dimension, located 0.1 cm from the upper surgical margin. To ensure the wide resection margins required for this type of neoplasm, a re-excision was performed. CONCLUSION: A dermatofibrosarcoma protuberans of the breast is an uncommon discovery. The aim of this case report is to highlight the importance of the surgical procedure in cases of the discovery of dermatofibrosarcoma protuberans. Re-excision may be necessary to ensure adequate resection margins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The results of several large multicenter CMR studies were reported in 2012, thus, constantly corroborating the evidence on CMR performance. In this review, we present results of the MR-IMPACT programme and the CE-MARC study, which demonstrated the superiority of perfusion-CMR over gated SPECT for the workup of suspected CAD, the currently available data from the European CMR registry, comprising almost 30,000 patients from 57 participating centers in 15 European countries, and finally, the results of the Advisa-MRI study, which documented the safety of a MRI-compatible pacemaker system. These large trials and others set the basis for the recommendations in the new European guidelines on heart failure to use CMR as a first line method if echocardiographic quality is inadequate or the etiology of heart failure is unclear.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chronic atrial fibrillation affects millions of people worldwide. Its surgical treatment often fails to restore the transport function of the atrium. This study first introduces the concept of an atrial assist device (AAD) to restore the pump function of the atrium. The AAD is developed to be totally implantable in the human body with a transcutaneous energy transfer system to recharge the implanted battery. The ADD consists of a motorless pump based on artificial muscle technology, positioned on the external surface of the atrium to compress it and restore its muscular activity. A bench model reproduces the function of a fibrillating atrium to assess the circulatory support that this pump can provide. Atripump (Nanopowers SA, Switzerland) is a dome-shaped silicone-coated nitinol actuator 5 mm high, sutured on the external surface of the atrium. A pacemaker-like control unit drives the actuator that compresses the atrium, providing the mechanical support to the blood circulation. Electrical characteristics: the system is composed of one actuator that needs a minimal tension of 15 V and has a maximum current of 1.5 A with a 50% duty cycle. The implantable rechargeable battery is made of a cell having the following specifications: nominal tension of a cell: 4.1 V, tension after 90% of discharge: 3.5 V, nominal capacity of a cell: 163 mA h. The bench model consists of an open circuit made of latex bladder 60 mm in diameter filled with water. The bladder is connected to a vertically positioned tube that is filled to different levels, reproducing changes in cardiac preload. The Atripump is placed on the outer surface of the bladder. Pressure, volume and temperature changes were recorded. The contraction rate was 1 Hz with a power supply of 12 V, 400 mA for 200 ms. Preload ranged from 15 to 21 cm H(2)O. Maximal silicone membrane temperature was 55 degrees C and maximal temperature of the liquid environment was 35 degrees C. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml min(-1). This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: To evaluate short-term clinical outcomes following transcatheter aortic valve implantation (TAVI) using CE-mark approved devices in Switzerland. METHODS AND RESULTS: The Swiss TAVI registry is a national, prospective, multicentre, monitored cohort study evaluating clinical outcomes in consecutive patients undergoing TAVI at cardiovascular centres in Switzerland. From February 2011 to March 2013, a total of 697 patients underwent TAVI for native aortic valve stenosis (98.1%), degenerative aortic bioprosthesis (1.6%) or severe aortic regurgitation (0.3%). Patients were elderly (82.4±6 years), 52% were females, and the majority highly symptomatic (73.1% NYHA III/IV). Patients with severe aortic stenosis (mean gradient 44.8±17 mmHg, aortic valve area 0.7±0.3 cm²) were either deemed inoperable or at high risk for conventional surgery (STS 8.2%±7). The transfemoral access was the most frequently used (79.1%), followed by transapical (18.1%), direct aortic (1.7%) and subclavian access (1.1%). At 30 days, rates of all-cause mortality, cerebrovascular events and myocardial infarction were 4.8%, 3.3% and 0.4%, respectively. The most frequently observed adverse events were access-related complications (11.8%), permanent pacemaker implantation (20.5%) and bleeding complications (16.6%). The Swiss TAVI registry is registered at ClinicalTrials.gov (NCT01368250). CONCLUSIONS: The Swiss TAVI registry is a national cohort study evaluating consecutive TAVI procedures in Switzerland. This first outcome report provides favourable short-term clinical outcomes in unselected TAVI patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report on two patients with recurrent syncope secondary to ictal bradyarrhythmias, triggered by partial epileptic seizures with atypical, stereotyped auras. Ictal bradyarrhythmias are potentially lethal, and likely originate from the involvement of limbic autonomic regions. The appropriate treatment is double-headed, including an antiepileptic drug and the implantation of a pacemaker.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The hyperpolarization-activated cyclic nucleotide-gated (HCN) channels are expressed in pacemaker cells very early during cardiogenesis. This work aimed at determining to what extent these channels are implicated in the electromechanical disturbances induced by a transient oxygen lack which may occur in utero. Spontaneously beating hearts or isolated ventricles and outflow tracts dissected from 4-day-old chick embryos were exposed to a selective inhibitor of HCN channels (ivabradine 0.1-10microM) to establish a dose-response relationship. The effects of ivabradine on electrocardiogram, excitation-contraction coupling and contractility of hearts submitted to anoxia (30min) and reoxygenation (60min) were also determined. The distribution of the predominant channel isoform, HCN4, was established in atria, ventricle and outflow tract by immunoblotting. Intrinsic beating rate of atria, ventricle and outflow tract was 164+/-22 (n=10), 78+/-24 (n=8) and 40+/-12bpm (n=23, mean+/-SD), respectively. In the whole heart, ivabradine (0.3microM) slowed the firing rate of atria by 16% and stabilized PR interval. These effects persisted throughout anoxia-reoxygenation, whereas the variations of QT duration, excitation-contraction coupling and contractility, as well as the types and duration of arrhythmias were not altered. Ivabradine (10microM) reduced the intrinsic rate of atria and isolated ventricle by 27% and 52%, respectively, whereas it abolished activity of the isolated outflow tract. Protein expression of HCN4 channels was higher in atria and ventricle than in the outflow tract. Thus, HCN channels are specifically distributed and control finely atrial, ventricular and outflow tract pacemakers as well as conduction in the embryonic heart under normoxia and throughout anoxia-reoxygenation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: We recently observed in a chronic ovine model that a shortening of action potential duration (APD) as assessed by the activation recovery interval (ARI) may be a mechanism whereby pacing-induced atrial tachycardia (PIAT) facilitates atrial fibrillation (AF), mediated by a return to 1:1 atrial capture after the effective refractory period has been reached. The aim of the present study is to evaluate the effect of long term intermittent burst pacing on ARI before induction of AF.Methods: We specifically developed a chronic ovine model of PIAT using two pacemakers (PM) each with a right atrial (RA) lead separated by ∼2cm. The 1st PM (Vitatron T70) was used to record a broadband unipolar RA EGM (800 Hz, 0.4 Hz high pass filter). The 2nd was used to deliver PIAT during electrophysiological protocols at decremental pacing CL (400 beats, from 400 to 110ms) and long term intermittent RA burst pacing to promote electrical remodeling (5s of burst followed by 2s of sinus rhythm) until onset of sustained AF. ARI was defined as the time difference between the peak of the atrial repolarization wave and the first atrial depolarization. The mean ARIs of paired sequences (before and after remodeling), each consisting of 20 beats were compared.Results: As shown in the figure, ARIs (n=4 sheep, 46 recordings) decreased post remodeling compared to baseline (86±19 vs 103±12 ms, p<0.05). There was no difference in atrial structure as assessed by light microscopy between control and remodeled sheep.Conclusions: Using standard pacemaker technology, atrial ARIs as a surrogate of APDs were successfully measured in vivo during the electrical remodeling process leading to AF. The facilitation of AF by PIAT mimicking salvos from pulmonary veins is heralded by a significant shortening of ARI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mammalian circadian timing system consists of a central pacemaker in the brain's suprachiasmatic nucleus (SCN) and subsidiary oscillators in nearly all body cells. The SCN clock, which is adjusted to geophysical time by the photoperiod, synchronizes peripheral clocks through a wide variety of systemic cues. The latter include signals depending on feeding cycles, glucocorticoid hormones, rhythmic blood-borne signals eliciting daily changes in actin dynamics and serum response factor (SRF) activity, and sensors of body temperature rhythms, such as heat shock transcription factors and the cold-inducible RNA-binding protein CIRP. To study these systemic signalling pathways, we designed and engineered a novel, highly photosensitive apparatus, dubbed RT-Biolumicorder. This device enables us to record circadian luciferase reporter gene expression in the liver and other organs of freely moving mice over months in real time. Owing to the multitude of systemic signalling pathway involved in the phase resetting of peripheral clocks the disruption of any particular one has only minor effects on the steady state phase of circadian gene expression in organs such as the liver. Nonetheless, the implication of specific pathways in the synchronization of clock gene expression can readily be assessed by monitoring the phase-shifting kinetics using the RT-Biolumicorder.