114 resultados para motion tracking
Resumo:
The most valuable pigment of the Roman wall paintings was the red color obtained from powdered cinnabar (Minium Cinnabaris pigment), the red mercury sulfide (HgS), which was brought from mercury (Hg) deposits in the Roman Empire. To address the question of whether sulfur isotope signatures can serve as a rapid method to establish the provenance of the red pigment in Roman frescoes, we have measured the sulfur isotope composition (delta(34) S value in parts per thousand VCDT) in samples of wall painting from the Roman city Aventicum (Avenches, Vaud, Switzerland) and compared them with values from cinnabar from European mercury deposits (Almaden in Spain, Idria in Slovenia, Monte Amiata in Italy, Moschellandsberg in Germany, and Genepy in France). Our study shows that the delta(34) S values of cinnabar from the studied Roman wall paintings fall within or near to the composition of Almaden cinnabar; thus, the provenance of the raw material may be deduced. This approach may provide information on provenance and authenticity in archaeological, restoration and forensic studies of Roman and Greek frescoes. Copyright (c) 2010 John Wiley & Sons, Ltd.
Resumo:
Thanks to decades of research, gait analysis has become an efficient tool. However, mainly due to the price of the motion capture systems, standard gait laboratories have the capability to measure only a few consecutive steps of ground walking. Recently, wearable systems were proposed to measure human motion without volume limitation. Although accurate, these systems are incompatible with most of existing calibration procedures and several years of research will be necessary for their validation. A new approach consisting of using a stationary system with a small capture volume for the calibration procedure and then to measure gait using a wearable system could be very advantageous. It could benefit from the knowledge related to stationary systems, allow long distance monitoring and provide new descriptive parameters. The aim of this study was to demonstrate the potential of this approach. Thus, a combined system was proposed to measure the 3D lower body joints angles and segmental angular velocities. It was then assessed in terms of reliability towards the calibration procedure, repeatability and concurrent validity. The dispersion of the joint angles across calibrations was comparable to those of stationary systems and good reliability was obtained for the angular velocities. The repeatability results confirmed that mean cycle kinematics of long distance walks could be used for subjects' comparison and pointed out an interest for the variability between cycles. Finally, kinematics differences were observed between participants with different ankle conditions. In conclusion, this study demonstrated the potential of a mixed approach for human movement analysis.
Resumo:
PURPOSE: Respiratory motion correction remains a challenge in coronary magnetic resonance imaging (MRI) and current techniques, such as navigator gating, suffer from sub-optimal scan efficiency and ease-of-use. To overcome these limitations, an image-based self-navigation technique is proposed that uses "sub-images" and compressed sensing (CS) to obtain translational motion correction in 2D. The method was preliminarily implemented as a 2D technique and tested for feasibility for targeted coronary imaging. METHODS: During a 2D segmented radial k-space data acquisition, heavily undersampled sub-images were reconstructed from the readouts collected during each cardiac cycle. These sub-images may then be used for respiratory self-navigation. Alternatively, a CS reconstruction may be used to create these sub-images, so as to partially compensate for the heavy undersampling. Both approaches were quantitatively assessed using simulations and in vivo studies, and the resulting self-navigation strategies were then compared to conventional navigator gating. RESULTS: Sub-images reconstructed using CS showed a lower artifact level than sub-images reconstructed without CS. As a result, the final image quality was significantly better when using CS-assisted self-navigation as opposed to the non-CS approach. Moreover, while both self-navigation techniques led to a 69% scan time reduction (as compared to navigator gating), there was no significant difference in image quality between the CS-assisted self-navigation technique and conventional navigator gating, despite the significant decrease in scan time. CONCLUSIONS: CS-assisted self-navigation using 2D translational motion correction demonstrated feasibility of producing coronary MRA data with image quality comparable to that obtained with conventional navigator gating, and does so without the use of additional acquisitions or motion modeling, while still allowing for 100% scan efficiency and an improved ease-of-use. In conclusion, compressed sensing may become a critical adjunct for 2D translational motion correction in free-breathing cardiac imaging with high spatial resolution. An expansion to modern 3D approaches is now warranted.
A New Method for ECG Tracking of Persistent Atrial Fibrillation Termination during Stepwise Ablation
Resumo:
Stepwise radiofrequency catheter ablation (step-CA) has become the treatment of choice for the restoration of sinus rhythm (SR) in patients with long-standing persistent atrial fibrillation (pers-AF). Its success rate appears limited as the amount of ablation to achieve long term SR is unknown. Multiple organization indexes (OIs) have been previously developed to track the organization of AF during step-CA, however, with limited success. We report an adaptive method for tracking AF termination (AF-term) based on OIs characterizing the relationship between harmonic components of atrial activity from the surface ECG of AF activity. By computing their relative evolution during the last two steps preceding AF-term, we found that the performance of our OIs was superior to classical indices to track the efficiency of step-CA "en route" to AF-term. Our preliminary results suggest that the gradual synchronization between the fundamental and its first harmonic of AF activity appears as a promising parameter for predicting AF-term during step-CA.
Resumo:
RESUME Les améliorations méthodologiques des dernières décennies ont permis une meilleure compréhension de la motilité gastro-intestinale. Il manque toutefois une méthode qui permette de suivre la progression du chyme le long du tube gastro-intestinal. Pour permettre l'étude de la motilité de tout le tractus digestif humain, une nouvelle technique, peu invasive, a été élaborée au Département de Physiologie, en collaboration avec l'EPFL. Appelée "Magnet Tracking", la technique est basée sur la détection du champ magnétique généré par des matériaux ferromagnétiques avalés. A cet usage, une pilule magnétique, une matrice de capteurs et un logiciel ont été développés. L'objet de ce travail est de démontrer la faisabilité d'un examen de la motilité gastro-intestinale chez l'Homme par cette méthode. L'aimant est un cylindre (ø 6x7 mm, 0.2 cm3) protégé par une gaine de silicone. Le système de mesure est constitué d'une matrice de 4x4 capteurs et d'un ordinateur portable. Les capteurs fonctionnent sur l'effet Hall. Grâce à l'interface informatique, l'évolution de la position de l'aimant est suivie en temps réel à travers tout le tractus digestif. Sa position est exprimée en fonction du temps ou reproduite en 3-D sous forme d'une trajectoire. Différents programmes ont été crées pour analyser la dynamique des mouvements de l'aimant et caractériser la motilité digestive. Dix jeunes volontaires en bonne santé ont participé à l'étude. L'aimant a été avalé après une nuit de jeûne et son séjour intra digestif suivi pendant 2 jours consécutifs. Le temps moyen de mesure était de 34 heures. Chaque sujet a été examiné une fois sauf un qui a répété sept fois l'expérience. Les sujets restaient en décubitus dorsal, tranquilles et pouvaient interrompre la mesure s'ils le désiraient. Ils sont restés à jeûne le premier jour. L'évacuation de l'aimant a été contrôlée chez tous les sujets. Tous les sujets ont bien supporté l'examen. Le marqueur a pu être détecté de l'oesophage au rectum. La trajectoire ainsi constituée représente une conformation de l'anatomie digestive : une bonne superposition de celle-ci à l'anatomie est obtenue à partir des images de radiologie conventionnelle (CT-scan, lavement à la gastrografine). Les mouvements de l'aimant ont été caractérisés selon leur périodicité, leur amplitude ou leur vitesse pour chaque segment du tractus digestif. Ces informations physiologiques sont bien corrélées à celles obtenues par des méthodes établies d'étude de la motilité gastro-intestinale. Ce travail démontre la faisabilité d'un examen de la motilité gastro-intestinal chez l'Homme par la méthode de Magnet Tracking. La technique fournit les données anatomiques et permet d'analyser en temps réel la dynamique des mouvements du tube digestif. Cette méthode peu invasive ouvre d'intéressantes perspectives pour l'étude de motilité dans des conditions physiologiques et pathologiques. Des expériences visant à valider cette approche en tant que méthode clinique sont en voie de réalisation dans plusieurs centres en Suisse et à l'étranger. SUMMARY Methodological improvements realised over the last decades have permitted a better understanding of gastrointestinal motility. Nevertheless, a method allowing a continuous following of lumina' contents is still lacking. In order to study the human digestive tract motility, a new minimally invasive technique was developed at the Department of Physiology in collaboration with Swiss Federal Institute of Technology. The method is based on the detection of magnetic field generated by swallowed ferromagnetic materials. The aim of our work was to demonstrate the feasibility of this new approach to study the human gastrointestinal motility. The magnet used was a cylinder (ø6x7mm, 0.2 cm3) coated with silicon. The magnet tracking system consisted of a 4x4 matrix of sensors based on the Hall effect Signals from the sensors were digitised and sent to a laptop computer for processing and storage. Specific software was conceived to analyse in real time the progression of the magnet through the gastrointestinal tube. Ten young and healthy volunteers were enrolled in the study. After a fasting period of 12 hours, they swallowed the magnet. The pill was then tracked for two consecutive days for 34 hours on average. Each subject was studied once except one who was studied seven times. Every subject laid on his back for the entire experiment but could interrupt it at anytime. Evacuation of the magnet was controlled in all subjects. The examination was well tolerated. The pill could be followed from the esophagus to the rectum. The trajectory of the magnet represented a "mould" of the anatomy of the digestive tube: a good superimposition with radiological anatomy (gastrografin contrast and CT) was obtained. Movements of the magnet were characterized by periodicity, velocity, and amplitude of displacements for every segment of the digestive tract. The physiological information corresponded well to data from current methods of studying gastrointestinal motility. This work demonstrates the feasibility of the new approach in studies of human gastrointestinal motility. The technique allows to correlate in real time the dynamics of digestive movements with the anatomical data. This minimally invasive method is ready for studies of human gastrointestinal motility under physiological as well as pathological conditions. Studies aiming at validation of this new approach as a clinically relevant tool are being realised in several centres in Switzerland and abroad. Abstract: A new minimally invasive technique allowing for anatomical mapping and motility studies along the entire human digestive system is presented. The technique is based on continuous tracking of a small magnet progressing through the digestive tract. The coordinates of the magnet are calculated from signals recorded by 16 magnetic field sensors located over the abdomen. The magnet position, orientation and trajectory are displayed in real time. Ten young healthy volunteers were followed during 34 h. The technique was well tolerated and no complication was encountered, The information obtained was 3-D con-figuration of the digestive tract and dynamics of the magnet displacement (velocity, transit time, length estimation, rhythms). In the same individual, repea-ted examination gave very reproducible results. The anatomical and physiological information obtained corresponded well to data from current methods and imaging. This simple, minimally invasive technique permits examination of the entire digestive tract and is suitable for both research and clinical studies. In combination with other methods, it may represent a useful tool for studies of Cl motility with respect to normal and pathological conditions.
Resumo:
Purpose: To investigate the effect of incremental increases in intraocular straylight on threshold measurements made by three modern forms of perimetry: Standard Automated Perimetry (SAP) using Octopus (Dynamic, G-Pattern), Pulsar Perimetry (PP) (TOP, 66 points) and the Moorfields Motion Displacement Test (MDT) (WEBS, 32 points).Methods: Four healthy young observers were recruited (mean age 26yrs [25yrs, 28yrs]), refractive correction [+2 D, -4.25D]). Five white opacity filters (WOF), each scattering light by different amounts were used to create incremental increases in intraocular straylight (IS). Resultant IS values were measured with each WOF and at baseline (no WOF) for each subject using a C-Quant Straylight Meter (Oculus, Wetzlar, Germany). A 25 yr old has an IS value of ~0.85 log(s). An increase of 40% in IS to 1.2log(s) corresponds to the physiological value of a 70yr old. Each WOFs created an increase in IS between 10-150% from baseline, ranging from effects similar to normal aging to those found with considerable cataract. Each subject underwent 6 test sessions over a 2-week period; each session consisted of the 3 perimetric tests using one of the five WOFs and baseline (both instrument and filter were randomised).Results: The reduction in sensitivity from baseline was calculated. A two-way ANOVA on mean change in threshold (where subjects were treated as rows in the block and each increment in fog filters was treated as column) was used to examine the effect of incremental increases in straylight. Both SAP (p<0.001) and Pulsar (p<0.001) were significantly affected by increases in straylight. The MDT (p=0.35) remained comparatively robust to increases in straylight.Conclusions: The Moorfields MDT measurement of threshold is robust to effects of additional straylight as compared to SAP and PP.
Resumo:
Biologie et médecine - Les podcasts de l'UNIL
Resumo:
We previously reported that nuclear grade assignment of prostate carcinomas is subject to a cognitive bias induced by the tumor architecture. Here, we asked whether this bias is mediated by the non-conscious selection of nuclei that "match the expectation" induced by the inadvertent glance at the tumor architecture. 20 pathologists were asked to grade nuclei in high power fields of 20 prostate carcinomas displayed on a computer screen. Unknown to the pathologists, each carcinoma was shown twice, once before a background of a low grade, tubule-rich carcinoma and once before the background of a high grade, solid carcinoma. Eye tracking allowed to identify which nuclei the pathologists fixated during the 8 second projection period. For all 20 pathologists, nuclear grade assignment was significantly biased by tumor architecture. Pathologists tended to fixate on bigger, darker, and more irregular nuclei when those were projected before kigh grade, solid carcinomas than before low grade, tubule-rich carcinomas (and vice versa). However, the morphometric differences of the selected nuclei accounted for only 11% of the architecture-induced bias, suggesting that it can only to a small part be explained by the unconscious fixation on nuclei that "match the expectation". In conclusion, selection of « matching nuclei » represents an unconscious effort to vindicate the gravitation of nuclear grades towards the tumor architecture.
Resumo:
The paleomagnetic investigations carried out in the 70's on Oligo-Miocene volcanics of Sardinia have demonstrated that the island was turned by 35-30 degrees clockwise from 33 Ma up to 3-1-20.5 Ma and rotated counterclockwise in a few million years [De Jong et al., 1969, 1973; Bobier et Coulon, 1970; Coulon et al., 1974; Manzoni, 1974, 1975; Bellon rr nl.. 1977: Edel et Lortscher, 1977; Edel, 1979, 1980]. Since then, the end of the rotation fixed at 19 Ma by Montigny er al. [1981] was the subject of discussions and several studies associating paleomagnetism and radiometric dating were undertaken [Assorgia er al., 1994: Vigliotti et Langenheim, 1995: Deino et al., 1997; Gattacceca rt Deino, 1999]. This is a contribution to this debate that is hampered by thr important secular variation recorded in the volcanics. The only way to get our of this problem is to sample series of successive flows as completely as possible, and to reduce the effect of secular variation by the calculation of means. Sampling was performed north of Bonorva in 5 pyroclastic flows that belong to the upper ignimbritic series SI2 according to Coulon rr nl. [1974] or LBLS according to Assorgia et al. [1997] (fig. I). Ar-40/Ar-39 dating of biotites from the debris flow (MDF) has yielded an age or 18.35 +/- 0.03 Ma [Dubois, 2000]. Five of the investigated sites are located beneath the debris flow ITV, TVB, TVD, SPM85, SPM86), one site was cured in the matrix of the debris flow (MDF) and one in 4 metric blocks included in the flow (DFC). Another site was sampled in the upper ash flow (PDM) that marks the end of the pyroclastic activity, just before the marine transgression. According to micropaleontological and radiometric dating this transgression has occurred between 18.35 and 17.6 Ma [Dubois, 2000]. After removal of a soft viscous component, the thermal demagnetization generally shows a univectorial behaviour of the remanent magnetization (fig. 2a). The maximum unblocking temperatures of 580-620 degrees (tab. I) and a rapid saturation below 100 mT (fig. 3) indicate that the carrier of the characteristic magnetization is magnetite. The exception comes: from the upper site PDM in which were found two characteristic components, one with a normal polarity and low unblocking temperatures up to 350 degreesC and one with a reversed polarity and maximum unblocking temperatures at 580-600 degreesC of magnetite. After calculation of a mean direction for each flow, the mean << Al >> direction 4 degrees /57 degrees (alpha (95) = 13 degrees) computed with the mean directions for the 5 flows may be considered as weakly affected by secular variation. But the results require a more careful examination. The declinations are N to NNW beneath the debris flow. NNW in the debris flow. and NNE (or SSW) above the debris flow, The elongated distribution of the directions obtained at sites TVB and TVD. scattered from the mean direction of TV to the mean direction of MDF is interpreted as due to partial overprinting during the debris How volcanic episode, The low temperature component PDMa is likely related to the alteration seen on thin sections and is also viewed as an overprint. As NNE/SSW directions occur as well below (mean direction << B >> : 5 degrees /58 degrees) as above the debris flow (PDMb : 200 degrees/-58 degrees). the NNW directions (<< C >> : 337 degrees /64 degrees) associated with the debris flow volcanism may be interpreted as resulting from a magnetic field excursion. According to the polarity scale of Cande and Kent [1992, 1995] and the radiometric age of MDF, the directions with normal polarity (TV, TVB, TVD, SPM85. SPM86a. MDF. DFC) may represent the period 5En. while the directions with reversed polarity PDMb and SPM86b were likely acquired during the period 5Dr. Using the mean << Al >> direction, the mean << B >>, or the PDM direction (tab. I). the deviation in declination with the direction of stable Europe 6.4 degrees /58.7 degrees (alpha (95) = 8 degrees) for a selection of 4 middle Tertiary poles by Besse et Courtillot [1991] or 7 degrees /56 degrees (alpha (95) = 3 degrees) for 19 poles listed by Edel [1980] can be considered as negligible. Using the results from the uppermost ignimbritic layer of Anglona also emplaced around 18.3 Ma [Odin rt al.. 1994]. the mean direction << E >> (3 degrees /51.5 degrees) leads to the same conclusion. On the contrary, when taking into account all dated results available for the period 5En (mean direction << D >> 353 degrees /56 degrees for 45 sites) (tab. II). the deviation 13 degrees is much more significant. As the rotation of Sardinia started around 21-20.5 Ma. the assumption of a constant velocity of rotation and the deviations of the Sardinia directions with respect to the stable Europe direction locate the end of the motion between 18.3 and 17.2 or 16.7 Ma (fig. 4). During the interval 18.35-17.5 Ma, the marine transgression took place. At the same period a NE-SW shortening interpreted as resulting from the collision of Sardinia with Apulia affected different parts of the island [Letouzey et al., 1982]. Consequently, the new paleomagnetic results and the tectono-sedimentary evolution are in favour of an end of the rotation at 17.5-18 Ma.