111 resultados para measuring device
Resumo:
Inflammasomes are multiprotein complexes whose activity has been implicated in physiological and pathological inflammation. The hallmarks of inflammasome activation are the secretion of the mature forms of Caspase-1 and IL-1β from cells of the innate immune system. This protocol covers the methods required to study inflammasome activation using mouse bone marrow-derived dendritic cells (BMDCs) as a model system. The protocol includes the generation and handling of BMDCs, the stimulation of BMDCs with established Nlrp3 inflammasome activators, and the measurement of activation by both ELISA and western blot. These methods can be useful for the study of potential inflammasome activators, and of the signaling pathways involved in inflammasome activation. General considerations are provided that may help in the design and optimization of modified methods for the study of other types of inflammasomes and in other cell types.
Resumo:
BACKGROUND AND AIMS: little is known regarding the reproducibility of body fat measuring devices; hence, we assessed the between and within-device reproducibility, and the within-day variability of body fat measurements. METHODS: body fat percentage was measured twice on seventeen female students aged between 18 and 20 with a body mass index of 21.9 ± 2.5 kg/m2 (mean ± SD) using seven bipolar bioelectrical impedance devices. Each participant was also measured each hour between 7:00 and 22:00. RESULTS: the correlation between first and second measurements was very high (Spearman r between 0.985 and 1.000, p<0.001), as well as between devices (Spearman r between 0.916 and 0.991, p<0.001). Repeated measurements analysis showed no differences were between devices (p=0.59) or readings (first vs. second: p=0.74). Conversely, significant differences were found between assessment periods throughout the day, measurements made in the morning being lower than those made in the afternoon (F test for repeated values= 6.58, p<0.001). CONCLUSIONS: the between and within-device reproducibility for measuring body fat is high, enabling the use of multiple devices in a single study. Conversely, small but significant changes in body fat measurements occur during the day, urging body fat measurements to be performed at fixed times.
Resumo:
OBJECTIVE: The aim of this study is to create a standard test to approve the efficacy of a surgical sealant. An industrial test, the bulge-and-blister test, which is very convenient for measuring adhesion energy, is applied to the surgical field to quantify adhesion of bioadhesives. METHODS: Samples were composed of two circular layers of equine pericardium glued by the surgical sealant studied. The sample was fixed to a support with an industrial glue. The support and the bottom layer were perforated in the centre to allow injection of pressurised water. Water was progressively introduced through the hole in the support and the bottom layer to create a blister with constant radius, increasing height and internal pressure during this first step. At a critical pressure, delamination started, the radius and height of the blister increased and the pressure decreased. At this point, the adhesion energy could be determined. The experimental parameters were measured with a pressure sensor and an optical profilometry device for deflection. RESULTS: Adhesion testing was carried out in eight paired equine pericardium samples bonded with a Dermabond cyanoacrylate glue. The average value of the practical adhesion energy is 2.3 Jm(-2) with a standard deviation of 1.5 Jm(-2). CONCLUSION: Application of the bulge-and-blister test to the surgical field was achieved and allowed a quantification of adhesion of a surgical glue. Such information is essential to compare the different surgical glues presently available. The study of the impact of bonding conditions such as pressure, hygrometry or setting conditions will provide a better understanding of the characteristics of adhesion in the surgical field.
Resumo:
OBJECTIVE: In general population survey instruments that measure volume of drinking, additional questions and shorter reference periods yield higher volumes. Comparison studies have focused on volume but not on associations between volume and consequences. METHOD: From a cohort study on substance use risk factors (Cohort Study on Substance Use Risk Factors [C-SURF]), baseline data were analyzed for 5,074 young (approximately 20-year-old) men who were drinkers in the past 12 months. Volume of drinking was measured by a generic quantity-frequency (QF) instrument, an extended QF (separately for weekends and weekdays) instrument with 12-months recall, and a retrospective past-week diary. Associations of consequences with and without attribution of alcohol as a cause, Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV), criteria for dependence, and DSM-5 alcohol use disorder in the past 12 months were analyzed. RESULTS: The generic QF measure resulted in lower volume compared with either the extended QF measure (more questions) or the retrospective diary (the most questions and the shortest recall period). For outcomes, however, the extended QF assessment performed the best and the diary the worst. CONCLUSIONS: Higher volume yields are not always better regarding associations with outcomes. The extended QF instrument better captures the variability of drinking. The retrospective diary performs poorly for associations because of the mismatch with the recall period for past-12-months consequences and the potential for misclassification of past-week abstainers and heavy drinkers because of an uncommon past week. Diaries are not recommended for research investigating individual associations between exposure and outcomes in young populations if consequences are measured with a sufficiently long interval to capture rare consequences. (J. Stud. Alcohol Drugs, 75, 880-888, 2014).
Resumo:
INTRODUCTION: Numerous instruments have been developed to assess spirituality and measure its association with health outcomes. This study's aims were to identify instruments used in clinical research that measure spirituality; to propose a classification of these instruments; and to identify those instruments that could provide information on the need for spiritual intervention. METHODS: A systematic literature search in MEDLINE, CINHAL, PsycINFO, ATLA, and EMBASE databases, using the terms "spirituality" and "adult$," and limited to journal articles was performed to identify clinical studies that used a spiritual assessment instrument. For each instrument identified, measured constructs, intended goals, and data on psychometric properties were retrieved. A conceptual and a functional classification of instruments were developed. RESULTS: Thirty-five instruments were retrieved and classified into measures of general spirituality (N = 22), spiritual well-being (N = 5), spiritual coping (N = 4), and spiritual needs (N = 4) according to the conceptual classification. Instruments most frequently used in clinical research were the FACIT-Sp and the Spiritual Well-Being Scale. Data on psychometric properties were mostly limited to content validity and inter-item reliability. According to the functional classification, 16 instruments were identified that included at least one item measuring a current spiritual state, but only three of those appeared suitable to address the need for spiritual intervention. CONCLUSIONS: Instruments identified in this systematic review assess multiple dimensions of spirituality, and the proposed classifications should help clinical researchers interested in investigating the complex relationship between spirituality and health. Findings underscore the scarcity of instruments specifically designed to measure a patient's current spiritual state. Moreover, the relatively limited data available on psychometric properties of these instruments highlight the need for additional research to determine whether they are suitable in identifying the need for spiritual interventions.
Resumo:
It is well known that dichotomizing continuous data has the effect to decrease statistical power when the goal is to test for a statistical association between two variables. Modern researchers however are focusing not only on statistical significance but also on an estimation of the "effect size" (i.e., the strength of association between the variables) to judge whether a significant association is also clinically relevant. In this article, we are interested in the consequences of dichotomizing continuous data on the value of an effect size in some classical settings. It turns out that the conclusions will not be the same whether using a correlation or an odds ratio to summarize the strength of association between the variables: Whereas the value of a correlation is typically decreased by a factor pi/2 after each dichotomization, the value of an odds ratio is at the same time raised to the power 2. From a descriptive statistical point of view, it is thus not clear whether dichotomizing continuous data leads to a decrease or to an increase in the effect size, as illustrated using a data set to investigate the relationship between motor and intellectual functions in children and adolescents
Resumo:
Abstract: Traditionally, pollution risk assessment is based on the measurement of a pollutant's total concentration in a sample. The toxicity of a given pollutant in the environment, however, is tightly linked to its bioavailability, which may differ significantly from the total amount. Physico-chemical and biological parameters strongly influence pollutant fate in terms of leaching, sequestration and biodegradation. Bacterial sensorreporters, which consist of living micro-organisms genetically engineered to produce specific output in response to target chemicals, offer an interesting alternative to monitoring approaches. Bacterial sensor-reporters detect bioavailable and/or bioaccessible compound fractions in samples. Currently, a variety of environmental pollutants can be targeted by specific biosensor-reporters. Although most of such strains are still confined to the lab, several recent reports have demonstrated utility of bacterial sensing-reporting in the field, with method detection limits in the nanomolar range. This review illustrates the general design principles for bacterial sensor-reporters, presents an overview of the existing biosensor-reporter strains with emphasis on organic compound detection. A specific focus throughout is on the concepts of bioavailability and bioaccessibility, and how bacteria-based sensing-reporting systems can help to improve our basic understanding of the different processes at work.
Resumo:
Introduction : Le monitoring de la tension artérielle à domicile est recommandé par plusieurs guidelines et a été montré être faisable chez la personne âgée. Les manomètres au poignet ont récemment été proposés pour la mesure de la tension artérielle à domicile, mais leur précision n'a pas été au préalable évaluée chez les patients âgés. Méthode : Quarante-huit participants (33 femmes et 15 hommes, moyenne d'âge 81.3±8.0 ans) ont leur tension artérielle mesurée avec un appareil au poignet avec capteur de position et un appareil au bras dans un ordre aléatoire et dans une position assise. Résultats : Les moyennes de mesures de tension artérielle étaient systématiquement plus basses avec l'appareil au poignet par rapport à celui du bras pour la pression systolique (120.1±2.2 vs. 130.5±2.2 mmHg, P < 0.001, moyenneidéviation standard) et pour la pression diastolique (66.011.3 vs. 69.7±1.3 mmHg, P < 0.001). De plus, une différence de lOmmHg ou plus grande entre l'appareil au bras et au poignet était observée dans 54.2 et 18,8% des mesures systoliques et diastoliques respectivement. Conclusion : Comparé à l'appareil au bras, l'appareil au poignet avec capteur de position sous-estimait systématiquement aussi bien la tension artérielle systolique que diastolique. L'ampleur de la différence est cliniquement significative et met en doute l'utilisation de l'appareil au poignet pour monitorer la tension artérielle chez la personne âgée. Cette étude indique le besoin de valider les appareils de mesures de la tension artérielle dans tous les groupes d'âge, y compris les personnes âgées.
Resumo:
We want to shed some light on the development of person mobility by analysing the repeated cross-sectional data of the four National Travel Surveys (NTS) that were conducted in Germany since the mid seventies. The above mentioned driving forces operate on different levels of the system that generates the spatial behaviour we observe: Travel demand is derived from the needs and desires of individuals to participate in spatially separated activities. Individuals organise their lives in an interactive process within the context they live in, using given infrastructure. Essential determinants of their demand are the individual's socio-demographic characteristics, but also the opportunities and constraints defined by the household and the environment are relevant for the behaviour which ultimately can be realised. In order to fully capture the context which determines individual behaviour, the (nested) hierarchy of persons within households within spatial settings has to be considered. The data we will use for our analysis contains information on these three levels. With the analysis of this micro-data we attempt to improve our understanding of the afore subsumed macro developments. In addition we will investigate the prediction power of a few classic sociodemographic variables for the daily travel distance of individuals in the four NTS data sets, with a focus on the evolution of this predictive power. The additional task to correctly measure distances travelled by means of the NTS is threatened by the fact that although these surveys measure the same variables, different sampling designs and data collection procedures were used. So the aim of the analysis is also to detect variables whose control corrects for the known measurement error, as a prerequisite to apply appropriate models in order to better understand the development of individual travel behaviour in a multilevel context. This task is complicated by the fact that variables that inform on survey procedures and outcomes are only provided with the data set for 2002 (see Infas and DIW Berlin, 2003).
Resumo:
Objective: to assess the between and within-device reproducibility, as well as within-day variability of body fat measurements. Methods: body fat percentage (%BF) was measured twice on seventeen female students aged between 18 and 20 with a body mass index of 21.9 22.6 kg/m2 (mean SD) using seven bipolar bioelectrical impedance devices (BF-306) according to the manufacturer's recommendations. Each student was also measured each hour between 7:00 and 22:00. Statistical analysis was conducted using a general linear model for repeated measurements. Results: the correlation between first and second measurements was very high (Pearson r between 0.985 and 1.000, p<0.001), as well as the correlation between devices (Pearson r between 0.986 and 0.999, all p<0.001). Repeated measurements analysis showed no differences were between devices (F test=0.83, p=0.59) or readings (first vs. second: F test=0.12, p=0.74). Conversely, significant differences were found between assessment periods throughout the day, measurements made in the morning being lower than those made in the afternoon. Assuming an overall daily average of 100 (based on all measurements), the values were 95.8 3.2 (mean SD) at 8:00 versus 101.3 3.0 at 20:00, corresponding to a mean change of 2.2 1.1 in %BF (F test for repeated values=6.58, p<0.001). Conclusions: the between and within-device reproducibility for measuring body fat is high, enabling the use of multiple devices in a single study. Conversely, small but significant changes in body fat measurements occur during the day, urging body fat measurements to be performed at fixed times.
Resumo:
Background: Current guidelines underline the limitations of existing instruments to assess fitness to drive and the poor adaptability of batteries of neuropsychological tests in primary care settings. Aims: To provide a free, reliable, transparent computer based instrument capable of detecting effects of age or drugs on visual processing and cognitive functions. Methods: Relying on systematic reviews of neuropsychological tests and driving performances, we conceived four new computed tasks measuring: visual processing (Task1), movement attention shift (Task2), executive response, alerting and orientation gain (Task3), and spatial memory (Task4). We then planned five studies to test MedDrive's reliability and validity. Study-1 defined instructions and learning functions collecting data from 105 senior drivers attending an automobile club course. Study-2 assessed concurrent validity for detecting minor cognitive impairment (MCI) against useful field of view (UFOV) on 120 new senior drivers. Study-3 collected data from 200 healthy drivers aged 20-90 to model age related normal cognitive decline. Study-4 measured MedDrive's reliability having 21 healthy volunteers repeat tests five times. Study-5 tested MedDrive's responsiveness to alcohol in a randomised, double-blinded, placebo, crossover, dose-response validation trial including 20 young healthy volunteers. Results: Instructions were well understood and accepted by all senior drivers. Measures of visual processing (Task1) showed better performances than the UFOV in detecting MCI (ROC 0.770 vs. 0.620; p=0.048). MedDrive was capable of explaining 43.4% of changes occurring with natural cognitive decline. In young healthy drivers, learning effects became negligible from the third session onwards for all tasks except for dual tasking (ICC=0.769). All measures except alerting and orientation gain were affected by blood alcohol concentrations. Finally, MedDrive was able to explain 29.3% of potential causes of swerving on the driving simulator. Discussion and conclusions: MedDrive reveals improved performances compared to existing computed neuropsychological tasks. It shows promising results both for clinical and research purposes.
Resumo:
Most ventricular assist devices (VADs) currently used in infants are extracorporeal. These VADs require long-term anticoagulation therapy and extensive surgery, and two devices are needed for biventricular support. We designed a biventricular assist device based on shape memory alloy that reproduces the hemodynamic effects of cardiomyoplasty, supporting the heart with a compressing movement, and evaluated its performance in a dedicated mockup system. Nitinol fibers are the device's key component. Ejection fraction (EF), cardiac output (CO), and generated systolic pressure were measured on a test bench. Our test bench settings were a preload range of 0-15 mm Hg, an afterload range of 0-160 mm Hg, and a heart rate (HR) of 20, 30, 40, and 60 beats/min. A power supply of 15 volts and 3.5 amperes was necessary. The EF range went from 34.4% to 1.2% as the afterload and HR increased, along with a CO from 180 to 6 ml/min. The device generated a maximal systolic pressure of 25 mm Hg. Cardiac compression for biventricular assistance in child-sized heart using shape memory alloy is technically feasible. Further testing remains necessary to assess this VAD's in vivo performance range and its reliability.