43 resultados para masculinity in motion pictures


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Despite the central role that emotional reactivity plays in adaptation, few studies have examined age differences in this capacity under well-controlled laboratory conditions, on the basis of standardized emotion-evoking stimuli and assessing experiential, expressive, and physiological measures. 212 adults ranging in age from 20 to 81 years were exposed to 14 picture series, each lasting 60 s and of a different valence and arousal. We assessed valence and arousal ratings, cardiovascular, respiratory and electrodermalmeasures, facial muscle activity and gaze activity. Here, we present findings for 22 younger (mean age=24.0) and 22 older (mean age=72.1) adults for valence and arousal ratings, systolic bloodpressure (SBP) andheart rate (HR).Compared to younger adults, older adults rated unpleasant seriesmore negatively and showed a smaller range in arousal for pleasant series. SBP linearly increased with increasing appetitive activation. HR showed the expected deceleration from the pleasant to the unpleasant series.However, this effect was clearer for the younger adults than the older adults. For older adults, if something is pleasant, it is also judged to be generally lower in arousal, whereas, if something is unpleasant, it is also judged to be generally higher in arousal. The results for SBP indicate that the association between arousal and sympathetic outflow to the cardiovascular system might be similar in younger and older adults. The results for HR suggest that the parasympathetic activation might be attenuated in older adults as compared to younger adults.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: This study aimed to assess the validity of COOP charts in a general population sample, to examine whether illustrations contribute to instrument validity, and to establish general population norms. METHODS: A general population mail survey was conducted among 20-79 years old residents of the Swiss canton of Vaud. Participants were invited to complete COOP charts, the SF-36 Health Survey; they also provided data on health service use in the previous month. Two thirds of the respondents received standard COOP charts, the rest received charts without illustrations. RESULTS: Overall 1250 persons responded (54%). The presence of illustrations did not affect score distributions, except that the illustrated 'physical fitness' chart drew greater non-response (10 vs. 3%, p < 0.001). Validity tests were similar for illustrated and picture-less charts. Factor analysis yielded two principal components, corresponding to physical and mental health. Six COOP charts showed strong and nearly linear relationships with corresponding SF36 scores (all p < 0.001), demonstrating concurrent validity. Similarly, most COOP charts were associated with the use of medical services in the past month. Only the chart on 'social support' partly deviated from construct validity hypotheses. Population norms revealed a generally lower health status in women and an age-related decline in physical health. CONCLUSIONS: COOP charts can be used to assess the health status of a general population. Their validity is good, with the possible exception of the 'social support' chart. The illustrations do not affect the properties of this instrument.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Diffusion-weighting in magnetic resonance imaging (MRI) increases the sensitivity to molecular Brownian motion, providing insight in the micro-environment of the underlying tissue types and structures. At the same time, the diffusion weighting renders the scans sensitive to other motion, including bulk patient motion. Typically, several image volumes are needed to extract diffusion information, inducing also inter-volume motion susceptibility. Bulk motion is more likely during long acquisitions, as they appear in diffusion tensor, diffusion spectrum and q-ball imaging. Image registration methods are successfully used to correct for bulk motion in other MRI time series, but their performance in diffusion-weighted MRI is limited since diffusion weighting introduces strong signal and contrast changes between serial image volumes. In this work, we combine the capability of free induction decay (FID) navigators, providing information on object motion, with image registration methodology to prospectively--or optionally retrospectively--correct for motion in diffusion imaging of the human brain. Eight healthy subjects were instructed to perform small-scale voluntary head motion during clinical diffusion tensor imaging acquisitions. The implemented motion detection based on FID navigator signals is processed in real-time and provided an excellent detection performance of voluntary motion patterns even at a sub-millimetre scale (sensitivity≥92%, specificity>98%). Motion detection triggered an additional image volume acquisition with b=0 s/mm2 which was subsequently co-registered to a reference volume. In the prospective correction scenario, the calculated motion-parameters were applied to perform a real-time update of the gradient coordinate system to correct for the head movement. Quantitative analysis revealed that the motion correction implementation is capable to correct head motion in diffusion-weighted MRI to a level comparable to scans without voluntary head motion. The results indicate the potential of this method to improve image quality in diffusion-weighted MRI, a concept that can also be applied when highest diffusion weightings are performed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The velocity of a liquid slug falling in a capillary tube is lower than predicted for Poiseuille flow due to presence of menisci, whose shapes are determined by the complex interplay of capillary, viscous, and gravitational forces. Due to the presence of menisci, a capillary pressure proportional to surface curvature acts on the slug and streamlines are bent close to the interface, resulting in enhanced viscous dissipation at the wedges. To determine the origin of drag-force increase relative to Poiseuille flow, we compute the force resultant acting on the slug by integrating Navier-Stokes equations over the liquid volume. Invoking relationships from differential geometry we demonstrate that the additional drag is due to viscous forces only and that no capillary drag of hydrodynamic origin exists (i.e., due to hydrodynamic deformation of the interface). Requiring that the force resultant is zero, we derive scaling laws for the steady velocity in the limit of small capillary numbers by estimating the leading order viscous dissipation in the different regions of the slug (i.e., the unperturbed Poiseuille-like bulk, the static menisci close to the tube axis and the dynamic regions close to the contact lines). Considering both partial and complete wetting, we find that the relationship between dimensionless velocity and weight is, in general, nonlinear. Whereas the relationship obtained for complete-wetting conditions is found in agreement with the experimental data of Bico and Quere [J. Bico and D. Quere, J. Colloid Interface Sci. 243, 262 (2001)], the scaling law under partial-wetting conditions is validated by numerical simulations performed with the Volume of Fluid method. The simulated steady velocities agree with the behavior predicted by the theoretical scaling laws in presence and in absence of static contact angle hysteresis. The numerical simulations suggest that wedge-flow dissipation alone cannot account for the entire additional drag and that the non-Poiseuille dissipation in the static menisci (not considered in previous studies) has to be considered for large contact angles.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: To determine whether a mono-, bi- or tri-exponential model best fits the intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) signal of normal livers. MATERIALS AND METHODS: The pilot and validation studies were conducted in 38 and 36 patients with normal livers, respectively. The DWI sequence was performed using single-shot echoplanar imaging with 11 (pilot study) and 16 (validation study) b values. In each study, data from all patients were used to model the IVIM signal of normal liver. Diffusion coefficients (Di ± standard deviations) and their fractions (fi ± standard deviations) were determined from each model. The models were compared using the extra sum-of-squares test and information criteria. RESULTS: The tri-exponential model provided a better fit than both the bi- and mono-exponential models. The tri-exponential IVIM model determined three diffusion compartments: a slow (D1 = 1.35 ± 0.03 × 10(-3) mm(2)/s; f1 = 72.7 ± 0.9 %), a fast (D2 = 26.50 ± 2.49 × 10(-3) mm(2)/s; f2 = 13.7 ± 0.6 %) and a very fast (D3 = 404.00 ± 43.7 × 10(-3) mm(2)/s; f3 = 13.5 ± 0.8 %) diffusion compartment [results from the validation study]. The very fast compartment contributed to the IVIM signal only for b values ≤15 s/mm(2) CONCLUSION: The tri-exponential model provided the best fit for IVIM signal decay in the liver over the 0-800 s/mm(2) range. In IVIM analysis of normal liver, a third very fast (pseudo)diffusion component might be relevant. KEY POINTS: ? For normal liver, tri-exponential IVIM model might be superior to bi-exponential ? A very fast compartment (D = 404.00 ± 43.7 × 10 (-3)  mm (2) /s; f = 13.5 ± 0.8 %) is determined from the tri-exponential model ? The compartment contributes to the IVIM signal only for b ≤ 15 s/mm (2.)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Free induction decay (FID) navigators were found to qualitatively detect rigid-body head movements, yet it is unknown to what extent they can provide quantitative motion estimates. Here, we acquired FID navigators at different sampling rates and simultaneously measured head movements using a highly accurate optical motion tracking system. This strategy allowed us to estimate the accuracy and precision of FID navigators for quantification of rigid-body head movements. Five subjects were scanned with a 32-channel head coil array on a clinical 3T MR scanner during several resting and guided head movement periods. For each subject we trained a linear regression model based on FID navigator and optical motion tracking signals. FID-based motion model accuracy and precision was evaluated using cross-validation. FID-based prediction of rigid-body head motion was found to be with a mean translational and rotational error of 0.14±0.21 mm and 0.08±0.13(°) , respectively. Robust model training with sub-millimeter and sub-degree accuracy could be achieved using 100 data points with motion magnitudes of ±2 mm and ±1(°) for translation and rotation. The obtained linear models appeared to be subject-specific as inter-subject application of a "universal" FID-based motion model resulted in poor prediction accuracy. The results show that substantial rigid-body motion information is encoded in FID navigator signal time courses. Although, the applied method currently requires the simultaneous acquisition of FID signals and optical tracking data, the findings suggest that multi-channel FID navigators have a potential to complement existing tracking technologies for accurate rigid-body motion detection and correction in MRI.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: The impacts of humeral offset and stem design after reverse shoulder arthroplasty (RSA) have not been well-studied, particularly with regard to newer stems which have a lower humeral inclination. The purpose of this study was to analyze the effect of different humeral stem designs on range of motion and humeral position following RSA. METHODS: Using a three-dimensional computer model of RSA, a traditional inlay Grammont stem was compared to a short curved onlay stem with different inclinations (155°, 145°, 135°) and offset (lateralised vs medialised). Humeral offset, the acromiohumeral distance (AHD), and range of motion were evaluated for each configuration. RESULTS: Altering stem design led to a nearly 7-mm change in humeral offset and 4 mm in the AHD. Different inclinations of the onlay stems had little influence on humeral offset and larger influence on decreasing the AHD. There was a 10° decrease in abduction and a 5° increase in adduction between an inlay Grammont design and an onlay design with the same inclination. Compared to the 155° model, the 135° model improved adduction by 28°, extension by 24° and external rotation of the elbow at the side by 15°, but led to a decrease in abduction of 9°. When the tray was placed medially, on the 145° model, a 9° loss of abduction was observed. CONCLUSIONS: With varus inclination prostheses (135° and 145°), elevation remains unchanged, abduction slightly decreases, but a dramatic improvement in adduction, extension and external rotation with the elbow at the side are observed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A number of recent papers have brought suggestive evidence for an active role of Chlamydiales in the establishment of the plastid. Chlamydiales define a very ancient group of obligate intracellular bacterial pathogens that multiply in vesicles within eukaryotic phagotrophic host cells such as animals, amoebae or other protists, possibly including the hypothetical phagotroph that internalized the cyanobacterial ancestor of the plastid over a billion years ago. We briefly survey the case for an active role of these ancient pathogens in plastid endosymbiosis. We argue that a good understanding of the Chlamydiales infection cycle and diversity may help to shed light on the process of metabolic integration of the evolving plastid.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Compensation for respiratory motion is needed while administering radiotherapy (RT) to tumors that are moving with respiration to reduce the amount of irradiated normal tissues and potentially decrease radiation-induced collateral damages. The purpose of this study was to test a new ventilation system designed to induce apnea-like suppression of respiratory motion and allow long enough breath hold durations to deliver complex RT. MATERIAL AND METHODS: The High Frequency Percussive Ventilation system was initially tested in a series of 10 volunteers and found to be well tolerated, allowing a median breath hold duration of 11.6min (range 3.9-16.5min). An evaluation of this system was subsequently performed in 4 patients eligible for adjuvant breast 3D conformal RT, for lung stereotactic body RT (SBRT), lung volumetric modulated arc therapy (VMAT), and VMAT for palliative pleural metastases. RESULTS: When compared to free breathing (FB) and maximal inspiration (MI) gating, this Percussion Assisted RT (PART) offered favorable dose distribution profiles in 3 out of the 4 patients tested. PART was applied in these 3 patients with good tolerance, without breaks during the "beam on time period" throughout the overall courses of RT. The mean duration of the apnea-like breath hold that was necessary for delivering all the RT fractions was 7.61min (SD=2.3). CONCLUSIONS: This first clinical implementation of PART was found to be feasible, tolerable and offers new opportunities in the field of RT for suppressing respiratory motion.