184 resultados para low dose irradiation
Resumo:
We compared the health-related quality-of-life of patients with newly diagnosed multiple myeloma aged over 65 years or transplant-ineligible in the pivotal, phase III FIRST trial. Patients received: i) continuous lenalidomide and low-dose dexamethasone until disease progression; ii) fixed cycles of lenalidomide and low-dose dexamethasone for 18 months; or iii) fixed cycles of melphalan, prednisone, thalidomide for 18 months. Data were collected using the validated questionnaires (QLQ-MY20, QLQ-C30, and EQ-5D). The analysis focused on the EQ-5D utility value and six domains pre-selected for their perceived clinical relevance. Lenalidomide and low-dose dexamethasone, and melphalan, prednisone, thalidomide improved patients' health-related quality-of-life from baseline over the duration of the study across all pre-selected domains of the QLQ-C30 and EQ-5D. In the QLQ-MY20, lenalidomide and low-dose dexamethasone demonstrated a significantly greater reduction in the Disease Symptoms domain compared with melphalan, prednisone, thalidomide at Month 3, and significantly lower scores for QLQ-MY20 Side Effects of Treatment at all post-baseline assessments except Month 18. Linear mixed-model repeated-measures analyses confirmed the results observed in the cross-sectional analysis. Continuous lenalidomide and low-dose dexamethasone delays disease progression versus melphalan, prednisone, thalidomide and has been associated with a clinically meaningful improvement in health-related quality-of-life. These results further establish continuous lenalidomide and low-dose dexamethasone as a new standard of care for initial therapy of myeloma by demonstrating superior health-related quality-of-life during treatment, compared with melphalan, prednisone, thalidomide.
Resumo:
La tomodensitométrie (TDM) est une technique d'imagerie pour laquelle l'intérêt n'a cessé de croitre depuis son apparition au début des années 70. De nos jours, l'utilisation de cette technique est devenue incontournable, grâce entre autres à sa capacité à produire des images diagnostiques de haute qualité. Toutefois, et en dépit d'un bénéfice indiscutable sur la prise en charge des patients, l'augmentation importante du nombre d'examens TDM pratiqués soulève des questions sur l'effet potentiellement dangereux des rayonnements ionisants sur la population. Parmi ces effets néfastes, l'induction de cancers liés à l'exposition aux rayonnements ionisants reste l'un des risques majeurs. Afin que le rapport bénéfice-risques reste favorable au patient il est donc nécessaire de s'assurer que la dose délivrée permette de formuler le bon diagnostic tout en évitant d'avoir recours à des images dont la qualité est inutilement élevée. Ce processus d'optimisation, qui est une préoccupation importante pour les patients adultes, doit même devenir une priorité lorsque l'on examine des enfants ou des adolescents, en particulier lors d'études de suivi requérant plusieurs examens tout au long de leur vie. Enfants et jeunes adultes sont en effet beaucoup plus sensibles aux radiations du fait de leur métabolisme plus rapide que celui des adultes. De plus, les probabilités des évènements auxquels ils s'exposent sont également plus grandes du fait de leur plus longue espérance de vie. L'introduction des algorithmes de reconstruction itératifs, conçus pour réduire l'exposition des patients, est certainement l'une des plus grandes avancées en TDM, mais elle s'accompagne de certaines difficultés en ce qui concerne l'évaluation de la qualité des images produites. Le but de ce travail est de mettre en place une stratégie pour investiguer le potentiel des algorithmes itératifs vis-à-vis de la réduction de dose sans pour autant compromettre la qualité du diagnostic. La difficulté de cette tâche réside principalement dans le fait de disposer d'une méthode visant à évaluer la qualité d'image de façon pertinente d'un point de vue clinique. La première étape a consisté à caractériser la qualité d'image lors d'examen musculo-squelettique. Ce travail a été réalisé en étroite collaboration avec des radiologues pour s'assurer un choix pertinent de critères de qualité d'image. Une attention particulière a été portée au bruit et à la résolution des images reconstruites à l'aide d'algorithmes itératifs. L'analyse de ces paramètres a permis aux radiologues d'adapter leurs protocoles grâce à une possible estimation de la perte de qualité d'image liée à la réduction de dose. Notre travail nous a également permis d'investiguer la diminution de la détectabilité à bas contraste associée à une diminution de la dose ; difficulté majeure lorsque l'on pratique un examen dans la région abdominale. Sachant que des alternatives à la façon standard de caractériser la qualité d'image (métriques de l'espace Fourier) devaient être utilisées, nous nous sommes appuyés sur l'utilisation de modèles d'observateurs mathématiques. Nos paramètres expérimentaux ont ensuite permis de déterminer le type de modèle à utiliser. Les modèles idéaux ont été utilisés pour caractériser la qualité d'image lorsque des paramètres purement physiques concernant la détectabilité du signal devaient être estimés alors que les modèles anthropomorphes ont été utilisés dans des contextes cliniques où les résultats devaient être comparés à ceux d'observateurs humain, tirant profit des propriétés de ce type de modèles. Cette étude a confirmé que l'utilisation de modèles d'observateurs permettait d'évaluer la qualité d'image en utilisant une approche basée sur la tâche à effectuer, permettant ainsi d'établir un lien entre les physiciens médicaux et les radiologues. Nous avons également montré que les reconstructions itératives ont le potentiel de réduire la dose sans altérer la qualité du diagnostic. Parmi les différentes reconstructions itératives, celles de type « model-based » sont celles qui offrent le plus grand potentiel d'optimisation, puisque les images produites grâce à cette modalité conduisent à un diagnostic exact même lors d'acquisitions à très basse dose. Ce travail a également permis de clarifier le rôle du physicien médical en TDM: Les métriques standards restent utiles pour évaluer la conformité d'un appareil aux requis légaux, mais l'utilisation de modèles d'observateurs est inévitable pour optimiser les protocoles d'imagerie. -- Computed tomography (CT) is an imaging technique in which interest has been quickly growing since it began to be used in the 1970s. Today, it has become an extensively used modality because of its ability to produce accurate diagnostic images. However, even if a direct benefit to patient healthcare is attributed to CT, the dramatic increase in the number of CT examinations performed has raised concerns about the potential negative effects of ionising radiation on the population. Among those negative effects, one of the major risks remaining is the development of cancers associated with exposure to diagnostic X-ray procedures. In order to ensure that the benefits-risk ratio still remains in favour of the patient, it is necessary to make sure that the delivered dose leads to the proper diagnosis without producing unnecessarily high-quality images. This optimisation scheme is already an important concern for adult patients, but it must become an even greater priority when examinations are performed on children or young adults, in particular with follow-up studies which require several CT procedures over the patient's life. Indeed, children and young adults are more sensitive to radiation due to their faster metabolism. In addition, harmful consequences have a higher probability to occur because of a younger patient's longer life expectancy. The recent introduction of iterative reconstruction algorithms, which were designed to substantially reduce dose, is certainly a major achievement in CT evolution, but it has also created difficulties in the quality assessment of the images produced using those algorithms. The goal of the present work was to propose a strategy to investigate the potential of iterative reconstructions to reduce dose without compromising the ability to answer the diagnostic questions. The major difficulty entails disposing a clinically relevant way to estimate image quality. To ensure the choice of pertinent image quality criteria this work was continuously performed in close collaboration with radiologists. The work began by tackling the way to characterise image quality when dealing with musculo-skeletal examinations. We focused, in particular, on image noise and spatial resolution behaviours when iterative image reconstruction was used. The analyses of the physical parameters allowed radiologists to adapt their image acquisition and reconstruction protocols while knowing what loss of image quality to expect. This work also dealt with the loss of low-contrast detectability associated with dose reduction, something which is a major concern when dealing with patient dose reduction in abdominal investigations. Knowing that alternative ways had to be used to assess image quality rather than classical Fourier-space metrics, we focused on the use of mathematical model observers. Our experimental parameters determined the type of model to use. Ideal model observers were applied to characterise image quality when purely objective results about the signal detectability were researched, whereas anthropomorphic model observers were used in a more clinical context, when the results had to be compared with the eye of a radiologist thus taking advantage of their incorporation of human visual system elements. This work confirmed that the use of model observers makes it possible to assess image quality using a task-based approach, which, in turn, establishes a bridge between medical physicists and radiologists. It also demonstrated that statistical iterative reconstructions have the potential to reduce the delivered dose without impairing the quality of the diagnosis. Among the different types of iterative reconstructions, model-based ones offer the greatest potential, since images produced using this modality can still lead to an accurate diagnosis even when acquired at very low dose. This work has clarified the role of medical physicists when dealing with CT imaging. The use of the standard metrics used in the field of CT imaging remains quite important when dealing with the assessment of unit compliance to legal requirements, but the use of a model observer is the way to go when dealing with the optimisation of the imaging protocols.
Resumo:
Le traitement médicamenteux du syndrome de Cushing secondaire à une hyperplasie surrénalienne macro-nodulaire bilatérale (bilateral macronodular adrenal hyperplasia, (BMAH)) est généralement administré pour une période limitée avant de procéder à l'exérèse chirurgicale des surrénales. Les antagonistes des récepteurs surrênaïïens aberrants se sont révélés inefficaces à long terme pour empêcher la surrénalectomie. Nous reportons le cas d'une patiente avec BMAH traitée durant 10 ans par des petites doses de kétoconazole, afin de contrôler la sécrétion de Cortisol. A l'âge de 48 ans, elle a présenté des céphalées et une hypertension artérielle. Les investigations ont donné les résultats suivants: absence de signes cliniques de syndrome de Cushing ; hyperplasie nodulaire des surrénales ; valeurs normales de la creatinine, le potassium et l'aldostérone plasmatiques ; valeurs normales des métanéphrines et de l'aldostérone urinaires ; élévation du Cortisol libre et des métabolites stéroïdiens urinaires ; et suppression de l'ACTH et de l'activité de la rénine plasmatiques. Un protocole de dépistage des récepteurs surrénaliens aberrants n'a pas montré de dépendance hormonale illégitime. Le kétoconazole a permis une normalisation rapide du Cortisol et de l'ACTH avec un effet qui persiste après 10 ans de traitement, tandis que l'imagerie surrénalienne ne montre pas de changement de taille et d'aspect de celles-ci. La sécrétion stéroidienne chez les patients présentant une BMAH est moins importante que celle de surrénales normales ou de tumeurs secrétrices et peut être contrôlée avec de petites doses de kétoconazole. Ce traitement, bien toléré, constitue une alternative au traitement chirurgical.
Resumo:
RESUME : Actuellement la brachythérapie endovasculaire reste le seul traitement efficace pour la resténose intrastent. Malgré ceci, la limitation majeure de cette technique est la resténose aux extrémités du stent (effet de bord) due à une couverture incomplète par la source radioactive (geographical miss). Le ballon coupant et qui ne glisse pas pourrait limiter le barotraumatisme engendré par la dilatation et qui avec la diminution de la radiation aux extrémités de la source radioactive, est à la base du geographical miss. Cette étude prospective a pour but d'examiner l'efficacité du traitement de la resténose intrastent par la combinaison d'angioplastie avec cutting ballon et β - irradiation. Le registre « Radiation in Europe NOvoste » (RENO) inclut tous les patients traités par β - irradiation coronaire avec le système Beta-CathTM System (Novoste Corporation, Brussels, Belgium) n'ayant pas été inclus dans une autre étude randomisée. Un premier sous-groupe de ces patients (groupe 1, n=166), représente les patients traités par cutting ballon et β - irradiation intra coronaire. Ce groupe a été défini d'une manière prospective et les résultats cliniques à 6 mois ont été comparés par rapport aux autres patients qui ont reçu un traitement par dilatation coronaire conventionnelle et β - irradiation (groupe 2, n=712). A 6 mois de suivi, on a retrouvé une différence significative entre les 2 groupes par rapport à la nécessité d'une nouvelle revascularisation du vaisseau préalablement traité (10,2% de récidive dans le groupe 1 contre 16,6 % dans le groupe 2 , p=0,04). Le nombre d'événements cardiaques majeurs (mortalité, infarctus du myocarde et revascularisation) a également été diminué de manière significative (10,8% contre 19,2% ; />=0,01). Cette observation a été confirmée par une analyse multivariée qui indique un risque diminué pour les événements cardiaques majeurs à 6 mois, (rapport de côtes : 0,49 ; intervalle de confiance 0,27-0,88 ; p=0,02). Comparé à l'angioplastie coronarienne avec ballon conventionnel, l'utilisation de cutting ballon avant la β - irradiation dans le traitement de la resténose intrastent démontre une meilleure évolution clinique à 6 mois. ABSTRACT: At present, vascular brachytherapy is the only efficient therapy for in-stent restenosis. Nevertheless edge restenosis often relat¬ed to geographical miss has been identified as a major limitation of the technique. The non-slippery cutting balloon has the potential to limit vascular barotraumas which, together with low-dose irradiation at both ends of the radioactive source, are the prerequisite for geographical miss. This prospective study aimed to examine the efficacy of combining cut¬ting balloon angioplasty and brachytherapy for in-stent restenosis. The Radiation in Europe NOvoste (RENO) registry prospectively tracked all patients who had been treated by coronary β-radiation with the Beta-CathTM System (Novoste Corporation. Brussels, Belgium) but were not included in a randomized radiation trial, A subgroup of patients with in-stent restenosis treated by cutting balloon angioplasty and coronary β-radiation (group 1, n = 166) was prospectively defined, and clinical outcomes of patients at 6 months were compared with those of patients treated by conventional angioplasty and coronary β -radiation (group 2, n = 712). At 6-month follow-up, there was a significant difference between groups 1 and 2 in- target vessel revascularization (10.2% versus 16.6% respectively; p = 0.04) and in the incidence of major adverse clinical events (MACE) including, death, myocardial infarction, and revascularization (10.8% versus 19.2%; p= 0.01). This observation was confirmed by a multivariate analysis indicating a. lower risk for MACE at 6 months (odds ratio: 0.49; confidence intervals: 0.27-0.88; p = 0.02). Compared to conventional angioplasty, cutting balloon angio¬plasty prior to coronary beta-radiation with the Beta-CathTM System seems to improve the 6-month clinical outcome in patients with in-stent restenosis.
Resumo:
LRH and its agonists have been shown to exert both stimulatory and inhibitory effects on testicular function. In the present study, the dose and length of treatment were tested to determine the appearance of the stimulatory and inhibitory effects of LRH agonist on testicular axis including the three levels. Two doses of an agonist of LRH, 40 and 100 ng/100 g body weight (buserelin, 'agonist'), were administered daily for 1 to 15 days to adult male rats. Control rats received the vehicle only. On day 1, 2, 4, 8 and 15 of treatment, the pituitary, testicular and peripheral levels (weight of accessory sex organs and androgen receptors in ventral prostate) were tested 6 h after the last injection. For the 15 days of treatment with both doses, a stimulatory effect of the 'agonist' was observed on LH and FSH release. A short exposure (1-2 days) to the low dose of the 'agonist' had a stimulatory effect on the density of LH/hCG testicular receptors (326 +/- 49 vs control 185 +/- 21 fmol/mg protein, mean +/- SEM), on the weights of seminal vesicles and ventral prostate and exposure to both doses led to high plasma testosterone levels (13.8 +/- 0.5 and 13.7 +/- 0.7 ng/ml, respectively, vs control 2.6 +/- 0.3 ng/ml), and to an increased density of nuclear androgen receptors in the ventral prostate (142 +/- 9 and 144 +/- 15 fmol/mg protein respectively vs control 97 +/- 12 fmol/mg protein).(ABSTRACT TRUNCATED AT 250 WORDS)
Resumo:
Radiotherapy is a widely used treatment option in cancer. However, recent evidence suggests that doses of ionizing radiation (IR) delivered inside the tumor target volume, during fractionated radiotherapy, can promote tumor invasion and metastasis. Furthermore, the tissues that surround the tumor area are also exposed to low doses of IR that are lower than those delivered inside the tumor mass, because external radiotherapy is delivered to the tumor through multiple radiation beams, in order to prevent damage of organs at risk. The biological effects of these low doses of IR on the healthy tissue surrounding the tumor area, and in particular on the vasculature remain largely to be determined. We found that doses of IR lower or equal to 0.8 Gy enhance endothelial cell migration without impinging on cell proliferation or survival. Moreover, we show that low-dose IR induces a rapid phosphorylation of several endothelial cell proteins, including the Vascular Endothelial Growth Factor (VEGF) Receptor-2 and induces VEGF production in hypoxia mimicking conditions. By activating the VEGF Receptor-2, low-dose IR enhances endothelial cell migration and prevents endothelial cell death promoted by an anti-angiogenic drug, bevacizumab. In addition, we observed that low-dose IR accelerates embryonic angiogenic sprouting during zebrafish development and promotes adult angiogenesis during zebrafish fin regeneration and in the murine Matrigel assay. Using murine experimental models of leukemia and orthotopic breast cancer, we show that low-dose IR promotes tumor growth and metastasis and that these effects were prevented by the administration of a VEGF receptor-tyrosine kinase inhibitor immediately before IR exposure. These findings demonstrate a new mechanism to the understanding of the potential pro-metastatic effect of IR and may provide a new rationale basis to the improvement of current radiotherapy protocols.
Resumo:
Treatment of hypertension remains a difficult task despite the availability of different types of medications lowering blood pressure by different mechanisms. In order to reach the target blood pressures recommended today combination therapy is required in most patients. The co-administration of two drugs with different impacts on the cardiovascular system markedly increases the antihypertensive effectiveness without altering adversely tolerability. Fixed low-dose combinations are becoming a valuable option not only as second-line, but also as first-line therapy. In this respect the co-administration of thiazide diuretic with an AT(1)-receptor blocker is particularly appealing. The diuretic-induced decrease in total body sodium activates the renin-angiotensin system, thus rendering blood pressure maintenance angiotensin II-dependent. During blockade of the renin-angiotensin system low doses of thiazides generally suffice, allowing the prevention of undesirable metabolic effects. Also, blockade of the AT(1)-receptor, particularly when angiotensin II production is enhanced in response to diuretic therapy, is expected to be beneficial, since angiotensin II seems to contribute importantly to the pathogenesis of cardiovascular and renal complications of hypertension.
Resumo:
BACKGROUND: Antiretroviral therapy (ART) containing tenofovir disoproxil fumarate (TDF) and didanosine (ddI) has been associated with poor immune recovery despite virologic success. This effect might be related to ddI toxicity since ddI exposure is substantially increased by TDF. OBJECTIVE: To analyze whether immune recovery during ART with TDF and ddI is ddI-dose dependent. DESIGN AND METHODS: A retrospective longitudinal analysis of immune recovery measured by the CD4 T-cell slope in 614 patients treated with ART containing TDF with or without ddI. Patients were stratified according to the tertiles of their weight-adjusted ddI dose: low dose (< 3.3 mg/kg), intermediate dose (3.3-4.1 mg/kg) and high dose (> 4.1 mg/kg). Cofactors modifying the degree of immune recovery after starting TDF-containing ART were identified by univariable and multivariable linear regression analyses. RESULTS: CD4 T-cell slopes were comparable between patients treated with TDF and a weight-adjusted ddI-dose of < 4.1 mg/kg per day (n = 143) versus TDF-without-ddI (n = 393). In the multivariable model the slopes differed by -13 CD4 T cells/mul per year [95% confidence interval (CI), -42 to 17; P = 0.40]. In contrast, patients treated with TDF and a higher ddI dose (> 4.1 mg/kg per day, n = 78) experienced a significantly impaired immune recovery (-47 CD4 T cells/microl per year; 95% CI, -82 to -12; P = 0.009). The virologic response was comparable between the different treatment groups. CONCLUSIONS: Immune recovery is impaired, when high doses of ddI (> 4.1 mg/kg) are given in combination with TDF. If the dose of ddI is adjusted to less than 4.1 mg/kg per day, immune recovery is similar to other TDF-containing ART regimen.
Resumo:
Ultrafractionation of radiation therapy is a novel regimen consisting of irradiating tumors several times daily, delivering low doses (<0.75 Gy) at which hyperradiosensitivity occurs. We recently demonstrated the high efficiency of ultrafractionated radiotherapy (RT) on glioma xenografts and report here on a phase II clinical trial to determine the safety, tolerability, and efficacy of an ultrafractionation regimen in patients with newly and inoperable glioblastoma (GBM). Thirty-one patients with histologically proven, newly diagnosed, and unresectable supratentorial GBM (WHO grade IV) were enrolled. Three daily doses of 0.75 Gy were delivered at least 4 hours apart, 5 days per week over 6-7 consecutive weeks (90 fractions for a total of 67.5 Gy). Conformal irradiation included the tumor bulk with a margin of 2.5 cm. The primary end points were safety, toxicity, and tolerability, and the secondary end points were overall survival (OS) and progression-free survival (PFS). Multivariate analysis was used to compare the OS and PFS with the EORTC-NCIC trial 26981-22981/CE.3 of RT alone vs radiation therapy and temozolomide (TMZ). The ultrafractionation radiation regimen was safe and well tolerated. No acute Grade III and/or IV CNS toxicity was observed. Median PFS and OS from initial diagnosis were 5.1 and 9.5 months, respectively. When comparing with the EORTC/NCIC trial, in both PFS and OS multivariate analysis, ultrafractionation showed superiority over RT alone, but not over RT and TMZ. The ultrafractionation regimen is safe and may prolong the survival of patients with GBM. Further investigation is warranted and a trial associating ultra-fractionation and TMZ is ongoing.
Resumo:
Intensity modulated radiotherapy (IMRT) is a conformal radiotherapy that produces concave and irregular target volume dose distributions. IMRT has a potential to reduce the volume of healthy tissue irradiated to a high dose, but this often at the price of an increased volume of normal tissue irradiated to a low dose. Clinical benefits of IMRT are expected to be most pronounced at the body sites where sensitive normal tissues surround or are located next to a target with a complex 3D shape. The irradiation doses needed for tumor control are often markedly higher than the tolerance of the radiation sensitive structures such as the spinal cord, the optic nerves, the eyes, or the salivary glands in the treatment of head and neck cancer. Parotid gland salivary flow is markedly reduced following a cumulative dose of 30 50 Gy given with conventional fractionation and xerostomia may be prevented in most patients using a conformal parotid-sparing radiotherapy technique. However, in cohort studies where IMRT was compared with conventional and conformal radiotherapy techniques in the treatment of laryngeal or oropharyngeal carcinoma, the dosimetric advantage of IMRT translated into a reduction of late salivary toxicity with no apparent adverse impact on the tumor control. IMRT might reduce the radiation dose to the major salivary glands and the risk of permanent xerostomia without compromizing the likelihood for cure. Alternatively, IMRT might allow the target dose escalation at a given level of normal tissue damage. We describe here the clinical results on postirradiation salivary gland function in head and neck cancer patients treated with IMRT, and the technical aspects of IMRT applied. The results suggest that the major salivary gland function can be maintained with IMRT without a need to compromise the clinical target volume dose, or the locoregional control.
Resumo:
Purpose: Although several approaches have been already used to reduce radiation dose, CT doses are still among the high doses in radio-diagnostic. Recently, General Electric introduced a new imaging reconstruction technique, adaptive statistical iterative reconstruction (ASIR), allows to taking into account the statistical fluctuation of noise. The benefits of ASIR method were assessed through classic metrics and the evaluations of cardiac structures by radiologists. Methods and materials: A 64-row CT (MDCT) was employed. Catphan600 phantom acquisitions and 10 routine-dose CT examinations performed at 80 kVp were reconstructed with FBP and with 50% of ASIR. Six radiologists then assessed the visibility of main cardiac structures using the visual grading analysis (VGA) method. Results: On phantoms, for a constant value of SD (25 HU), CTDIvol is divided by 2 (8 mGy to 4 mGy) when 50% of ASIR is used. At constant CTDIvol, MTF medium frequencies were also significantly improved. First results indicated that clinical images reconstructed with ASIR had a better overall image quality compared with conventional reconstruction. This means that at constant image quality the radiation dose can be strongly reduced. Conclusion: The first results of this study shown that the ASIR method improves the image quality on phantoms by decreasing noise and improving resolution with respect to the classical one. Moreover, the benefit obtained is higher at lower doses. In clinical environment, a dose reduction can still be expected on 80 kVp low dose pediatric protocols using 50% of iterative reconstruction. Best ASIR percentage as a function of cardiac structures and detailed protocols will be presented for cardiac examinations.
Resumo:
AIM: The aim of this study was to investigate the effect of an acute small ethanol (EtOH) dose (0.5 ml EtOH/kg fat-free mass, combined with carbohydrate) in a drink on endurance performance of trained cyclists. METHODS: Thirteen well-trained male cyclists took part in this study. A 60-min cycling endurance performance test (time trial) was performed in a calorimetric chamber after drinking an EtOH (30 +/- 1.8 ml) or a non-EtOH control (C) drink. RESULTS: Overall, EtOH induced a significant decrease in the average cycling power output (PO) (EtOH: 233 +/- 23 W versus C: 243 +/- 24 W, P < 0.01). The time course of mechanical PO showed an early decrease during the EtOH trial as compared to C (P < 0.01). Due to the lower PO, oxygen consumption, carbon dioxide production and glucose oxidation were significantly lower (P < 0.05) as compared to C. Relative to PO, heart rate response and ratings of perceived exertion (RPE) were increased by EtOH as compared to C (P < 0.05). In contrast, EtOH did not influence gross work efficiency, glycaemia and blood lactate concentration. CONCLUSIONS: These results show that the acute low dose of EtOH decreased endurance performance. An increase of cardio-vascular strain and psychobiological mechanisms may explain this decrease of endurance performance.
Resumo:
OBJECTIVE: To assess the survival benefit and safety profile of low-dose (850 mg/kg) and high-dose (1350 mg/kg) phospholipid emulsion vs. placebo administered as a continuous 3-day infusion in patients with confirmed or suspected Gram-negative severe sepsis. Preclinical and ex vivo studies show that lipoproteins bind and neutralize endotoxin, and experimental animal studies demonstrate protection from septic death when lipoproteins are administered. Endotoxin neutralization correlates with the amount of phospholipid in the lipoprotein particles. DESIGN: A three-arm, randomized, blinded, placebo-controlled trial. SETTING: Conducted at 235 centers worldwide between September 2004 and April 2006. PATIENTS: A total of 1379 patients participated in the study, 598 patients received low-dose phospholipid emulsion, and 599 patients received placebo. The high-dose phospholipid emulsion arm was stopped, on the recommendation of the Independent Data Monitoring Committee, due to an increase in life-threatening serious adverse events at the fourth interim analysis and included 182 patients. MEASUREMENTS AND MAIN RESULTS: A 28-day all-cause mortality and new-onset organ failure. There was no significant treatment benefit for low- or high-dose phospholipid emulsion vs. placebo for 28-day all-cause mortality, with rates of 25.8% (p = .329), 31.3% (p = .879), and 26.9%, respectively. The rate of new-onset organ failure was not statistically different among groups at 26.3%, 31.3%, 20.4% with low- and high-dose phospholipid emulsion, and placebo, respectively (one-sided p = .992, low vs. placebo; p = .999, high vs. placebo). Of the subjects treated, 45% had microbiologically confirmed Gram-negative infections. Maximal changes in mean hemoglobin levels were reached on day 10 (-1.04 g/dL) and day 5 (-1.36 g/dL) with low- and high-dose phospholipid emulsion, respectively, and on day 14 (-0.82 g/dL) with placebo. CONCLUSIONS: Treatment with phospholipid emulsion did not reduce 28-day all-cause mortality, or reduce the onset of new organ failure in patients with suspected or confirmed Gram-negative severe sepsis.
Resumo:
BACKGROUND: The ongoing Ebola outbreak led to accelerated efforts to test vaccine candidates. On the basis of a request by WHO, we aimed to assess the safety and immunogenicity of the monovalent, recombinant, chimpanzee adenovirus type-3 vector-based Ebola Zaire vaccine (ChAd3-EBO-Z). METHODS: We did this randomised, double-blind, placebo-controlled, dose-finding, phase 1/2a trial at the Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland. Participants (aged 18-65 years) were randomly assigned (2:2:1), via two computer-generated randomisation lists for individuals potentially deployed in endemic areas and those not deployed, to receive a single intramuscular dose of high-dose vaccine (5 × 10(10) viral particles), low-dose vaccine (2·5 × 10(10) viral particles), or placebo. Deployed participants were allocated to only the vaccine groups. Group allocation was concealed from non-deployed participants, investigators, and outcome assessors. The safety evaluation was not masked for potentially deployed participants, who were therefore not included in the safety analysis for comparison between the vaccine doses and placebo, but were pooled with the non-deployed group to compare immunogenicity. The main objectives were safety and immunogenicity of ChAd3-EBO-Z. We did analysis by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT02289027. FINDINGS: Between Oct 24, 2014, and June 22, 2015, we randomly assigned 120 participants, of whom 18 (15%) were potentially deployed and 102 (85%) were non-deployed, to receive high-dose vaccine (n=49), low-dose vaccine (n=51), or placebo (n=20). Participants were followed up for 6 months. No vaccine-related serious adverse events were reported. We recorded local adverse events in 30 (75%) of 40 participants in the high-dose group, 33 (79%) of 42 participants in the low-dose group, and five (25%) of 20 participants in the placebo group. Fatigue or malaise was the most common systemic adverse event, reported in 25 (62%) participants in the high-dose group, 25 (60%) participants in the low-dose group, and five (25%) participants in the placebo group, followed by headache, reported in 23 (57%), 25 (60%), and three (15%) participants, respectively. Fever occurred 24 h after injection in 12 (30%) participants in the high-dose group and 11 (26%) participants in the low-dose group versus one (5%) participant in the placebo group. Geometric mean concentrations of IgG antibodies against Ebola glycoprotein peaked on day 28 at 51 μg/mL (95% CI 41·1-63·3) in the high-dose group, 44·9 μg/mL (25·8-56·3) in the low-dose group, and 5·2 μg/mL (3·5-7·6) in the placebo group, with respective response rates of 96% (95% CI 85·7-99·5), 96% (86·5-99·5), and 5% (0·1-24·9). Geometric mean concentrations decreased by day 180 to 25·5 μg/mL (95% CI 20·6-31·5) in the high-dose group, 22·1 μg/mL (19·3-28·6) in the low-dose group, and 3·2 μg/mL (2·4-4·9) in the placebo group. 28 (57%) participants given high-dose vaccine and 31 (61%) participants given low-dose vaccine developed glycoprotein-specific CD4 cell responses, and 33 (67%) and 35 (69%), respectively, developed CD8 responses. INTERPRETATION: ChAd3-EBO-Z was safe and well tolerated, although mild to moderate systemic adverse events were common. A single dose was immunogenic in almost all vaccine recipients. Antibody responses were still significantly present at 6 months. There was no significant difference between doses for safety and immunogenicity outcomes. This acceptable safety profile provides a reliable basis to proceed with phase 2 and phase 3 efficacy trials in Africa. FUNDING: Swiss State Secretariat for Education, Research and Innovation (SERI), through the EU Horizon 2020 Research and Innovation Programme.