99 resultados para limits of visual detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to estimate the potential of method restriction as a public health strategy in suicide prevention. Data from the Swiss Federal Statistical Office and the Swiss Institutes of Forensic Medicine from 2004 were gathered and categorized into suicide submethods according to accessibility to restriction of means. Of suicides in Switzerland, 39.2% are accessible to method restriction. The highest proportions were found in private weapons (13.2%), army weapons (10.4%), and jumps from hot-spots (4.6%). The presented method permits the estimation of the suicide prevention potential of a country by method restriction and the comparison of restriction potentials between suicide methods. In Switzerland, reduction of firearm suicides has the highest potential to reduce the total number of suicides.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transparency is now seen as a key tool of democratic governance. The European Union's commitment to transparency is now at the centre of a crucial debate between the Commission and the Parliament on the future of citizen's right of access to information. This article presents the main characteristics of the current regime and questions the pertinence of the proposed changes in light of the international drive at modernising access to information laws and the attempt at identifying the ̳proper limits of transparency'. The questions raised range from the identification of what can be accessed to the definition of exemption and the protection of competing interests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dynamic behavior of the decondensed chromatin can be monitored by real-time fluorescence confocal microscopy. It can be observed that different chromosomal sites enjoy different degrees of freedom during a certain period, exploring larger or smaller portions of nuclear volume. Here we measure the accessible surface for two chromosomal sites (yeast telomeres Tel3R and Tel6R) that both exhibit strong preferential association with the nuclear membrane in galactose-containing media, but differ significantly in gene activity. Telomere Tel6R, which harbors an inducible gene with high levels of transcription, explores a much larger surface than the telomere Tel3R, which is adjacent to inactive chromatin. Thus, our results distinguish two perinuclear movements characteristic of different transcriptional state, allowing for a better understanding of the correlation between activity of genes and chromatin dynamics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La fibroscopie oesophagienne n'est pas sans poser quelques problèmes : pouvoir optique limité, examen insuffisant de l'hypopharynx et des zones sphinctériennes, manque de sélectivité des biopsies en muqueuse plane, possibilités instrumentales insuffisantes pour la désobstruction alimentaire et l'hémostase. Bien que le fibroscope reste l'instrument de choix pour les examens de routine, l'oesophagoscope rigide doit jouer un rôle déterminant dans le bilan pré-thérapeutique des patients porteurs d'un carcinome epidermoïde « précoce », dans l'extraction des corps étrangers, et dans toutes les situations complexes où l'instrument flexible se révèle insuffisant pour des raisons techniques (biopsie, coloration vitale, désobstruction alimentaire, etc.).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The growing use of direct oral anticoagulants, in particular among older subjects, raises questions about the limits of the evidence-based medicine. The phase III studies that have validated the efficacy and the safety profile of these molecules (dabigatran, rivaroxaban, apixaban, edoxaban) in their both indications, the venous thromboembolic disease and the non-valvular atrial fibrillation raise concerns in four major fields: the financial support of pharmaceutical companies, the links of interest for many authors with the industry, the study design (exclusively non-inferiority studies), and the poor representativeness of the older subjects included. All these points are discussed, using data of sub-groups studies, post-marketing studies and recent meta-analysis. The lack of data for the very old subjects, with frailty or comorbidities, remains the main concern from these phase III studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reléguée au rang de moyen diagnostique occasionnel avec l'avènement de la streptomycine dès 1945, la thoracoscopie a repris depuis trois à cinq ans un rôle prépondérant dans l'armement du chirurgien thoracique, comme moyen diagnostique et surtout comme outil thérapeutique. Dans cet article, nous faisons le point quant à la place actuelle de la thoracoscopie face aux différentes pathologies thoraciques, pulmonaires, médiastinales et oesophagiennes. Dans certaines indications (pneumothorax, infiltrats pulmonaires diffus, nodule pulmonaire isolé), cette technique en pleine expansion a déjà clairement démontré sa supériorité. Dans d'autres cas, en particulier dans les affections néoplasiques, son application est encore le sujet de controverses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Time perception is used in our day-to-day activities. While we understand quite well how our brain processes vision, touch or taste, brain mechanisms subserving time perception remain largely understudied. In this study, we extended an experiment of previous master thesis run by Tatiana Kenel-Pierre. We focused on time perception in the range of milliseconds. Previous studies have demonstrated the involvement of visual areas V1 and V5/MT in the encoding of temporal information of visual stimuli. Based on these previous findings the aim of the present study was to understand if temporal information was encoded in V1 and extrastriate area V5/MT in different spatial frames i.e., head- centered versus eye-centered. To this purpose we asked eleven healthy volunteers to perform a temporal discrimination task of visual stimuli. Stimuli were presented at 4 different spatial positions (i.e., different combinations of retinotopic and spatiotopic position). While participants were engaged in this task we interfered with the activity of the right dorsal V1 and the right V5/MT with transcranial magnetic stimulation (TMS). Our preliminary results showed that TMS over both V1 and V5/MT impaired temporal discrimination of visual stimuli presented at specific spatial coordinates. But whereas TMS over V1 impaired temporal discrimination of stimuli presented in the lower left quadrant, TMS over V5/MT affected temporal discrimination of stimuli presented at the top left quadrant. Although it is always difficult to draw conclusions from preliminary results, we could tentatively say that our data seem to suggest that both V1 and V5/MT encode visual temporal information in specific spatial frames.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A collaborative study on Raman spectroscopy and microspectrophotometry (MSP) was carried out by members of the ENFSI (European Network of Forensic Science Institutes) European Fibres Group (EFG) on different dyed cotton fabrics. The detection limits of the two methods were tested on two cotton sets with a dye concentration ranging from 0.5 to 0.005% (w/w). This survey shows that it is possible to detect the presence of dye in fibres with concentrations below that detectable by the traditional methods of light microscopy and microspectrophotometry (MSP). The MSP detection limit for the dyes used in this study was found to be a concentration of 0.5% (w/w). At this concentration, the fibres appear colourless with light microscopy. Raman spectroscopy clearly shows a higher potential to detect concentrations of dyes as low as 0.05% for the yellow dye RY145 and 0.005% for the blue dye RB221. This detection limit was found to depend both on the chemical composition of the dye itself and on the analytical conditions, particularly the laser wavelength. Furthermore, analysis of binary mixtures of dyes showed that while the minor dye was detected at 1.5% (w/w) (30% of the total dye concentration) using microspectrophotometry, it was detected at a level as low as 0.05% (w/w) (10% of the total dye concentration) using Raman spectroscopy. This work also highlights the importance of a flexible Raman instrument equipped with several lasers at different wavelengths for the analysis of dyed fibres. The operator and the set up of the analytical conditions are also of prime importance in order to obtain high quality spectra. Changing the laser wavelength is important to detect different dyes in a mixture.