71 resultados para instrumentation for chemistry laboratories


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thermal springs of Acquarossa and the nearby mineral springs of Soia have outlet temperatures of 12 degrees to 25 degrees C, TDS of 2290 to 3000 mg/kg and Ca-SO4 to Ca-SO4-HCO3 composition. Chemical geothermometers suggest reservoir temperatures close to 60 degrees C. P-CO2 values at depth are estimated to range from 0.3 to 2 bar. delta D and delta(18)O values indicate a meteoric origin and recharge elevations of 1600 +/- 150 m above sea level (a.s.l.) for these thermal and mineral waters. All these waters discharge from the overturned limb of the Simano nappe, probably dose to the contact between basement and underlying cover rocks. They therefore represent rain waters that descend slowly, heat at depth and locally rise relatively quickly to the surface, preserving part of their physical and chemical characteristics. (C) 1999 CNR. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a silicon chip-based approach for the enhanced sensitivity detection of surface-immobilized fluorescent molecules. Green fluorescent protein (GFP) is bound to the silicon substrate by a disuccinimidyl terephtalate-aminosilane immobilization procedure. The immobilized organic layers are characterized by surface analysis techniques, like ellipsometry, atomic force microscopy (AFM) and X-ray induced photoelectron spectroscopy. We obtain a 20-fold enhancement of the fluorescent signal, using constructive interference effects in a fused silica dielectric layer, deposited before immobilization onto the silicon. Our method opens perspectives to increase by an order of magnitude the fluorescent response of surface immobilized DNA- or protein-based layers for a variety of biosensor applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Committee of the European Concerted Action for Multiple Sclerosis (Charcot Foundation) organised five workshops to discuss CSF analytical standards in the diagnosis of multiple sclerosis. This consensus report from 12 European countries summarises the results of those workshops. It is hoped that neurologists will confer with their colleagues in clinical chemistry to arrange the best possible local practice. The most sensitive method for the detection of oligoclonal immunoglobulin bands is isoelectric focusing. The same amounts of IgG in parallel CSF and serum samples are used and oligoclonal bands are revealed with IgG specific antibody staining. All laboratories performing isoelectric focusing should check their technique at least annually using "blind" standards for the five different CSF and serum patterns. Quantitative measurements of IgG production in the CNS are less sensitive than isoelectric focusing. The preferred method for detection of blood-CSF barrier dysfunction is the albumin quotient. The CSF albumin or total protein concentrations are less satisfactory. These results must be interpreted with reference to the age of the patient and the local method of determination. Cells should be counted. The normal value is no more than 4 cells/microliters. Among evolving optional tests, measurement of the combined local synthesis of antibodies against measles, rubella, and/or varicella zoster could represent a significant advance if it offers higher specificity (not sensitivity) for identifying chronic rather than acute inflammation. Other tests that may have useful correlations with clinical indices include those for oligoclonal free light chains, IgM, IgA, or myelin basic protein concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

According to the annual report of the World Anti-Doping Agency, steroids are the most frequently detected class of doping agents. Detecting the misuse of endogenously occurring steroids, i.e. steroids such as testosterone that are produced naturally by humans, is one of the most challenging issues in doping control analysis. The established thresholds for urinary concentrations or concentration ratios such as the testosterone/epitestosterone quotient are sometimes inconclusive owing to the large biological variation in these parameters.For more than 15 years, doping control laboratories focused on the carbon isotope ratios of endogenous steroids to distinguish between naturally elevated steroid profile parameters and illicit administration of steroids. A variety of different methods has been developed throughout the last decade and the number of different steroids under investigation by isotope ratio mass spectrometry has recently grown considerably. Besides norandrosterone, boldenone was found to occur endogenously in rare cases and the misuse of corticosteroids or epitestosterone can now be detected with the aid of carbon isotope ratios as well. In addition, steroids excreted as sulfoconjugates were investigated, and the first results regarding hydrogen isotope ratios recently became available.All of these will be presented in detail within this review together with some considerations on validation issues and on identification of parameters influencing steroidal isotope ratios in urine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Hyperoxaluria is a major risk factor for kidney stone formation. Although urinary oxalate measurement is part of all basic stone risk assessment, there is no standardized method for this measurement. METHODS: Urine samples from 24-h urine collection covering a broad range of oxalate concentrations were aliquoted and sent, in duplicates, to six blinded international laboratories for oxalate, sodium and creatinine measurement. In a second set of experiments, ten pairs of native urine and urine spiked with 10 mg/L of oxalate were sent for oxalate measurement. Three laboratories used a commercially available oxalate oxidase kit, two laboratories used a high-performance liquid chromatography (HPLC)-based method and one laboratory used both methods. RESULTS: Intra-laboratory reliability for oxalate measurement expressed as intraclass correlation coefficient (ICC) varied between 0.808 [95% confidence interval (CI): 0.427-0.948] and 0.998 (95% CI: 0.994-1.000), with lower values for HPLC-based methods. Acidification of urine samples prior to analysis led to significantly higher oxalate concentrations. ICC for inter-laboratory reliability varied between 0.745 (95% CI: 0.468-0.890) and 0.986 (95% CI: 0.967-0.995). Recovery of the 10 mg/L oxalate-spiked samples varied between 8.7 ± 2.3 and 10.7 ± 0.5 mg/L. Overall, HPLC-based methods showed more variability compared to the oxalate oxidase kit-based methods. CONCLUSIONS: Significant variability was noted in the quantification of urinary oxalate concentration by different laboratories, which may partially explain the differences of hyperoxaluria prevalence reported in the literature. Our data stress the need for a standardization of the method of oxalate measurement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contamination with arsenic is a recurring problem in both industrialized and developing countries. Drinking water supplies for large populations can have concentrations much higher than the permissible levels (for most European countries and the United States, 10 μg As per L; elsewhere, 50 μg As per L). Arsenic analysis requires high-end instruments, which are largely unavailable in developing countries. Bioassays based on genetically engineered bacteria have been proposed as suitable alternatives but such tests would profit from better standardization and direct incorporation into sensing devices. The goal of this work was to develop and test microfluidic devices in which bacterial bioreporters could be embedded, exposed and reporter signals detected, as a further step towards a complete miniaturized bacterial biosensor. The signal element in the biosensor is a nonpathogenic laboratory strain of Escherichia coli, which produces a variant of the green fluorescent protein after contact to arsenite and arsenate. E. coli bioreporter cells were encapsulated in agarose beads and incorporated into a microfluidic device where they were captured in 500 × 500 μm(2) cages and exposed to aqueous samples containing arsenic. Cell-beads frozen at -20 °C in the microfluidic chip retained inducibility for up to a month and arsenic samples with 10 or 50 μg L(-1) could be reproducibly discriminated from the blank. In the 0-50 μg L(-1) range and with an exposure time of 200 minutes, the rate of signal increase was linearly proportional to the arsenic concentration. The time needed to reliably and reproducibly detect a concentration of 50 μg L(-1) was 75-120 minutes, and 120-180 minutes for a concentration of 10 μg L(-1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A second collaborative exercise on RNA/DNA co-analysis for body fluid identification and STR profiling was organized by the European DNA Profiling Group (EDNAP). Six human blood stains, two blood dilution series (5-0.001 μl blood) and, optionally, bona fide or mock casework samples of human or non-human origin were analyzed by the participating laboratories using a RNA/DNA co-extraction or solely RNA extraction method. Two novel mRNA multiplexes were used for the identification of blood: a highly sensitive duplex (HBA, HBB) and a moderately sensitive pentaplex (ALAS2, CD3G, ANK1, SPTB and PBGD). The laboratories used different chemistries and instrumentation. All of the 18 participating laboratories were able to successfully isolate and detect mRNA in dried blood stains. Thirteen laboratories simultaneously extracted RNA and DNA from individual stains and were able to utilize mRNA profiling to confirm the presence of blood and to obtain autosomal STR profiles from the blood stain donors. The positive identification of blood and good quality DNA profiles were also obtained from old and compromised casework samples. The method proved to be reproducible and sensitive using different analysis strategies. The results of this collaborative exercise involving a RNA/DNA co-extraction strategy support the potential use of an mRNA based system for the identification of blood in forensic casework that is compatible with current DNA analysis methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phosphopeptides tagging reactions by dinuclear zinc(II) complexes (1,3-bis[bis(2-pyridylmethyl)amino]-propan-2-olato dizinc(II)3+, called tag) were performed with a dual-channel microsprayer in electrospray ionization mass spectrometry. The reaction is first studied ex situ and analyzed with a commercial electrospray source. In situ reactions (i.e., inside the Taylor cone) were achieved with a dual-channel microsprayer both with the tag synthesized chemically before the experiments and with the tag electrogenerated by in situ oxidation of a zinc electrode, also used to apply the electrospray current. The device consists of a polyimide microchip with two microchannels (20 microm x 50 microm x 1 cm) etched on each side of the structure and connecting only at the tip of the microchip. We demonstrate here that mixing two solutions with different physicochemical properties inside the Taylor cone can be used to selectively tag target molecules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS: Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS: The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC's ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS: Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.