212 resultados para dose econômica
Resumo:
PURPOSE: to evaluate the efficacy and the safety of low dose intraocular tissue plasminogen activator (rt-PA) in the treatment of traumatic hyphema and postoperative fibrinous membrane. METHODS: Six microg to 10 microg of rt-PA was injected into the anterior chamber to treat severe fibrinous postoperative membranes and total traumatic hyphemae. RESULTS: Thirteen eyes of 13 patients were treated. Four cases of traumatic hyphema and 9 cases of fibrinous membranes were included. Complete fibrinolysis within 24 hours was observed in 4 cases (30.8%). A partial success was noted in 7 eyes (53.8%). No beneficial effect was observed in two cases of traumatic hyphema associated with intravitreal hemorrhage after penetrating trauma. No side effect attributable to rt-PA occurred. CONCLUSION: Low dose intraocular rt-PA appears to be safe and effective in the treatment of postoperative fibrinous membrane and endocular hemorrhage limited to the anterior chamber.
Resumo:
Introduction Vitamin D plays a major role in bone metabolismand neuromuscular function. Supplementation with vitamin D iseffective to reduce the risk of fall and of fracture. However adherenceto oral daily vitamin D is low. Screening and correcting vitamin Dinsufficiency in a rheumatologic population could improve bothmorbidity and quality of life. After determining the prevalence ofvitamin D deficiency in this population, we evaluated if supplementationwith a single high dose of oral 25-OH vitamin D3 wassufficient to correct this abnormality.Methods During one month (November 2009), levels of 25-OHvitamin D were systematically determined in our rheumatology outpatientclinic and classified in: vitamin D deficiency (< 10 μg/l),vitamin D insufficiency (10 to 30 μg/l) or normal vitamin D (> 30 μg/l).Patients with insufficiency or deficiency received respectively a singlehigh dose of 300'000 IU or 600'000 IU oral vitamin D3. In addition,all patients with osteoporosis were prescribed daily supplement ofcalcium (1 g) and vitamin D (800 IU). 25-OH vitamin D levels werereevaluated after 3 months.Results Vitamin D levels were initially determined in 292 patients(mean age 53, 211 women, 87 % Caucasian). 77 % had inflammatoryrheumatologic disease (IRD), 20 % osteoporosis (OP) and 12 %degenerative disease (DD). Vitamin D deficiency was present in 20(6.8 %), while 225 (77.1 %) had insufficiency. Of the 245 patientswith levels < 30μg/l, a new determination of vitamin D level wasavailable in 173 (71 %) at 3 months.Conclusion Vitamin D insufficiency is highly prevalent in ourrheumatologic population (84 %), and is not adequately correctedby a single high dose of oral vitamin D3 in > 50 % of the patientswith IRD and DD. In patients with OP, despite association of asingle high dose with daily oral vitamin D supplementation, 40 %of patients are still deficient when reevaluated at 3 months.
Resumo:
Quality assurance programmes are becoming a common practice in the field of mammography. At the present time several recommendations exist and different test objects are used to optimize this radiological procedure. The goal of this study was to check if geographically distant centres using different quality control procedures were comparable when using a common objective way of assessing image quality. The results show that consensus still needs to be found among radiologists to reach a satisfactory level of harmony between patient doses and image quality in Europe.
Resumo:
20 patients with liver metastases from colorectal carcinoma undergoing laparotomy received 15-60 mg intravenously, either intact or fragments of, anti-carcinoembryonic antigen (anti-CEA) monoclonal antibodies labelled with 0.55-1.48 GBq (15-40 mCi) of 131I, 3-8 days prior to operation. The uptake measured per gram of metastases ranged from 0.33 to 6.6 x 10(-3%) of injected dose. Tumour to liver uptake ratios ranged from 2 to 33. The radiation dose, estimated in 6 patients (3 of each group), for an extrapolated dose of 3.7 GBq (100 mCi) of 131I ranged from 0.3 to 0.8 Gy in normal liver or spleen (an acceptable estimate for bone marrow radiation dose) and from 3.4 to 8.2 Gy to the hepatic metastases, indicating that probably other therapeutic modalities should be associated with radioimmunotherapy.
Resumo:
BACKGROUND: In this study we compared the immunogenicity of influenza vaccine administered intradermally to the standard intramuscular vaccination in lung transplant recipients. METHODS: Patients were randomized to receive the trivalent inactivated seasonal 2008-9 influenza vaccine containing either 6 μg (intradermal) or 15 μg (intramuscular) of hemagglutinin per viral strain. Immunogenicity was assessed by measurement of geometric mean titer of antibodies using the hemagglutination-inhibition (HI) assay. Vaccine response was defined as a 4-fold or higher increase of antibody titers to at least one vaccine antigen. RESULTS: Eighty-five patients received either the intradermal (n = 41) or intramuscular (n = 44) vaccine. Vaccine response was seen in 6 of 41 patients (14.6%) in the intradermal vs 8 of 43 (18.6%) in the intramuscular group (p = 0.77). Seroprotection (HI ≥1:32) was 39% for H1N1, 83% for H3N2 and 29% for B strain in the intradermal group vs 28% for H1N1, 98% for H3N2 and 58% for B strain in the intramuscular group (p = 0.36 for H1N1, p = 0.02 for H3N2, p < 0.01 for B). Mild adverse events were seen in 44% of patients in the intradermal group and 34% in the intramuscular group (p = 0.38). CONCLUSIONS: Immunogenicity of the 2008-9 influenza vaccine given intradermally or intramuscularly was overall poor in lung transplant recipients. Novel strategies for influenza vaccination in this population are needed.
Resumo:
The shape of the energy spectrum produced by an x-ray tube has a great importance in mammography. Many anode-filtration combinations have been proposed to obtain the most effective spectrum shape for the image quality-dose relationship. On the other hand, third generation synchrotrons such as the European Synchrotron Radiation Facility in Grenoble are able to produce a high flux of monoenergetic radiation. It is thus a powerful tool to study the effect of beam energy on image quality and dose in mammography. An objective method was used to evaluate image quality and dose in mammography with synchrotron radiation and to compare them to standard conventional units. It was performed systematically in the energy range of interest for mammography through the evaluation of a global image quality index and through the measurement of the mean glandular dose. Compared to conventional mammography units, synchrotron radiation shows a great improvement of the image quality-dose relationship, which is due to the beam monochromaticity and to the high intrinsic collimation of the beam, which allows the use of a slit instead of an anti-scatter grid for scatter rejection.
Resumo:
BACKGROUND: Unexplained fatigue is often left untreated or treated with antidepressants. This randomized, placebo-controlled, single-blinded study evaluated the efficacy and tolerability of single-dose intravenous ferric carboxymaltose (FCM) in iron-deficient, premenopausal women with symptomatic, unexplained fatigue. METHODS: Fatigued women (Piper Fatigue Scale [PFS] score ≥5) with iron deficiency (ferritin <50 µg/L and transferrin saturation <20%, or ferritin <15 µg/L) and normal or borderline hemoglobin (≥115 g/L) were enrolled in 21 sites in Austria, Germany, Sweden and Switzerland, blinded to the study drug and randomized (computer-generated randomization sequence) to a single FCM (1000 mg iron) or saline (placebo) infusion. Primary endpoint was the proportion of patients with reduced fatigue (≥1 point decrease in PFS score from baseline to Day 56). RESULTS: The full analysis included 290 women (FCM 144, placebo 146). Fatigue was reduced in 65.3% (FCM) and 52.7% (placebo) of patients (OR 1.68, 95%CI 1.05-2.70; p = 0.03). A 50% reduction of PFS score was achieved in 33.3% FCM- vs. 16.4% placebo-treated patients (p<0.001). At Day 56, all FCM-treated patients had hemoglobin levels ≥120 g/L (vs. 87% at baseline); with placebo, the proportion decreased from 86% to 81%. Mental quality-of-life (SF-12) and the cognitive function scores improved better with FCM. 'Power of attention' improved better in FCM-treated patients with ferritin <15 µg/L. Treatment-emergent adverse events (placebo 114, FCM 209; most frequently headache, nasopharyngitis, pyrexia and nausea) were mainly mild or moderate. CONCLUSION: A single infusion of FCM improved fatigue, mental quality-of-life, cognitive function and erythropoiesis in iron-deficient women with normal or borderline hemoglobin. Although more side effects were reported compared to placebo, FCM can be an effective alternative in patients who cannot tolerate or use oral iron, the common treatment of iron deficiency. Overall, the results support the hypothesis that iron deficiency can affect women's health, and a normal iron status should be maintained independent of hemoglobin levels. TRIAL REGISTRATION: ClinicalTrials.gov NCT01110356.
Resumo:
BACKGROUND: Iterative reconstruction (IR) techniques reduce image noise in multidetector computed tomography (MDCT) imaging. They can therefore be used to reduce radiation dose while maintaining diagnostic image quality nearly constant. However, CT manufacturers offer several strength levels of IR to choose from. PURPOSE: To determine the optimal strength level of IR in low-dose MDCT of the cervical spine. MATERIAL AND METHODS: Thirty consecutive patients investigated by low-dose cervical spine MDCT were prospectively studied. Raw data were reconstructed using filtered back-projection and sinogram-affirmed IR (SAFIRE, strength levels 1 to 5) techniques. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at C3-C4 and C6-C7 levels. Two radiologists independently and blindly evaluated various anatomical structures (both dense and soft tissues) using a 4-point scale. They also rated the overall diagnostic image quality using a 10-point scale. RESULTS: As IR strength levels increased, image noise decreased linearly, while SNR and CNR both increased linearly at C3-C4 and C6-C7 levels (P < 0.001). For the intervertebral discs, the content of neural foramina and dural sac, and for the ligaments, subjective image quality scores increased linearly with increasing IR strength level (P ≤ 0.03). Conversely, for the soft tissues and trabecular bone, the scores decreased linearly with increasing IR strength level (P < 0.001). Finally, the overall diagnostic image quality scores increased linearly with increasing IR strength level (P < 0.001). CONCLUSION: The optimal strength level of IR in low-dose cervical spine MDCT depends on the anatomical structure to be analyzed. For the intervertebral discs and the content of neural foramina, high strength levels of IR are recommended.
Resumo:
Treatment of hypertension remains a difficult task despite the availability of different types of medications lowering blood pressure by different mechanisms. In order to reach the target blood pressures recommended today combination therapy is required in most patients. The co-administration of two drugs with different impacts on the cardiovascular system markedly increases the antihypertensive effectiveness without altering adversely tolerability. Fixed low-dose combinations are becoming a valuable option not only as second-line, but also as first-line therapy. In this respect the co-administration of thiazide diuretic with an AT(1)-receptor blocker is particularly appealing. The diuretic-induced decrease in total body sodium activates the renin-angiotensin system, thus rendering blood pressure maintenance angiotensin II-dependent. During blockade of the renin-angiotensin system low doses of thiazides generally suffice, allowing the prevention of undesirable metabolic effects. Also, blockade of the AT(1)-receptor, particularly when angiotensin II production is enhanced in response to diuretic therapy, is expected to be beneficial, since angiotensin II seems to contribute importantly to the pathogenesis of cardiovascular and renal complications of hypertension.
Resumo:
Au cours des deux dernières décennies, la technique d'imagerie arthro-scanner a bénéficié de nombreux progrès technologiques et représente aujourd'hui une excellente alternative à l'imagerie par résonance magnétique (IRM) et / ou arthro-IRM dans l'évaluation des pathologies de la hanche. Cependant, elle reste limitée par l'exposition aux rayonnements ionisants importante. Les techniques de reconstruction itérative (IR) ont récemment été mis en oeuvre avec succès en imagerie ; la littérature montre que l'utilisation ces dernières contribue à réduire la dose d'environ 40 à 55%, comparativement aux protocoles courants utilisant la rétroprojection filtrée (FBP), en scanner de rachis. A notre connaissance, l'utilisation de techniques IR en arthro-scanner de hanche n'a pas été évaluée jusqu'à présent. Le but de notre étude était d'évaluer l'impact de la technique ASIR (GE Healthcare) sur la qualité de l'image objective et subjective en arthro-scanner de hanche, et d'évaluer son potentiel en terme de réduction de dose. Pour cela, trente sept patients examinés par arthro-scanner de hanche ont été randomisés en trois groupes : dose standard (CTDIvol = 38,4 mGy) et deux groupes de dose réduite (CTDIvol = 24,6 ou 15,4 mGy). Les images ont été reconstruites en rétroprojection filtrée (FBP) puis en appliquant différents pourcentages croissants d'ASIR (30, 50, 70 et 90%). Le bruit et le rapport contraste sur bruit (CNR) ont été mesurés. Deux radiologues spécialisés en imagerie musculo-squelettique ont évalué de manière indépendante la qualité de l'image au niveau de plusieurs structures anatomiques en utilisant une échelle de quatre grades. Ils ont également évalué les lésions labrales et du cartilage articulaire. Les résultats révèlent que le bruit augmente (p = 0,0009) et le CNR diminue (p = 0,001) de manière significative lorsque la dose diminue. A l'inverse, le bruit diminue (p = 0,0001) et le contraste sur bruit augmente (p < 0,003) de manière significative lorsque le pourcentage d'ASIR augmente ; on trouve également une augmentation significative des scores de la qualité de l'image pour le labrum, le cartilage, l'os sous-chondral, la qualité de l'image globale (au delà de ASIR 50%), ainsi que le bruit (p < 0,04), et une réduction significative pour l'os trabuculaire et les muscles (p < 0,03). Indépendamment du niveau de dose, il n'y a pas de différence significative pour la détection et la caractérisation des lésions labrales (n=24, p = 1) et des lésions cartilagineuses (n=40, p > 0,89) en fonction du pourcentage d'ASIR. Notre travail a permis de montrer que l'utilisation de plus de 50% d'ASIR permet de reduire de manière significative la dose d'irradiation reçue par le patient lors d'un arthro-scanner de hanche tout en maintenant une qualité d'image diagnostique comparable par rapport à un protocole de dose standard utilisant la rétroprojection filtrée.
Resumo:
Introduction et objectif: Lors d'essais cliniques, le pharmacien est responsable de la préparation et de la dispensation des médicaments à évaluer. Un article récent a toutefois montré que les aspects pharmaceutiques liés au contrôle de la dose administrée in fine étaient souvent mal contrôlés. Il peut exister une différence entre la dose nominale fournie par le certificat d'analyse du fabricant et la dose réellement administrée au sujet, biais qui se reporte en cascade sur l'estimation des paramètres pharmaco¬cinétiques (PK), comme la clairance ou le volume de distribution. Ce travail visait à évaluer les biais entachant la quantité de médicament réellement injectée (iv/sc) aux volontaires d'un essai clinique étudiant la PK et la relation dose-réponse d'un nouveau produit biotechnologique. Méthode: La dose de médicament administrée lors de l'essai clinique (D) a été calculée de la manière suivante: D = C ? V - pertes. La concentration du produit (C; titre nominal du fabricant) a été vérifiée par immuno-essai. Le volume de médicament injecté (V) a été déterminé pour chaque injection par pesée (n=72), en utilisant la masse de la seringue avant et après injection et la densité du produit. Enfin, une analyse in vitro a permis d'évaluer les pertes liées à l'adsorption du produit dans les lignes de perfusion et de choisir le dispositif adéquat in vivo. Résultats: La concentration du médicament s'est révélée proche du titre nominal (96 ± 7%), et a été utilisée comme référence. Le volume injecté était quant à lui entaché d'un biais systématique par rapport à la valeur théorique correspondant à 0.03 mL pour la dose minimale (i.e. 75% du volume à injecter à cette dose). Une analyse complémentaire a montré que cela s'expliquait par une réaspiration partielle de la solution médica-menteuse avant le retrait de la seringue après injection sc, due à l'élasticité du piston. En iv, le biais était par contre provoqué par une réaspiration du soluté de perfusion co-administré. Enfin, la mesure des quantités de médicament récupérées après injection dans le dispositif de perfusion a démontré des pertes minimales par adsorption. Discussion-conclusion: Cette étude confirme l'existence de biais inversement corrélés au volume et à la concentration du médicament administré, pouvant provoquer des erreurs importantes sur les paramètres PK. Ce problème est négligé ou insuffisamment considéré dans les protocoles de Phase I et nécessiterait une planification rigoureuse. Les procédures opératoires devraient attirer l'attention sur ce point crucial.
Resumo:
Background: CYP2D6 is the key enzyme responsible for tamoxifen bioactivation mainly into endoxifen. This gene is highly polymorphic and breast cancer patients classified as CYP2D6 poor metabolizers (PM) or intermediate metabolizers (IM) appear to show low concentrations of endoxifen and to achieve less benefit from tamoxifen treatment. Purpose: This prospective, open-label trial aimed to assess how the increase of tamoxifen dose influences the level of endoxifen in the different genotype groups (poor-, intermediate-, and extensive-metabolizers (EM)). We examined the impact of doubling tamoxifen dose to 20mg twice daily on endoxifen plasma concentrations across these genotype groups. Patients and methods: Patients were assayed for CYP2D6 genotype and phenotype using dextromethorphan test. Tamoxifen, N-desmethyltamoxifen, 4-hydroxytamoxifen and endoxifen plasma levels were determined on 2 occasions at baseline (20mg/day of tamoxifen) and at day 30, 90 and 120 after dose increase (20 mg twice daily) using liquid chromatography-tandem-mass spectrometry. Endoxifen plasma levels were measured 6 to 24 hours after last drug intake to evaluate its accumulation before and after doubling tamoxifen dosage. ANOVA was used to evaluate endoxifen levels increase and difference between genotype groups. Results: 63 patients are available for analysis to date. Tamoxifen, N-desmethyltamoxifen, 4-hydroxytamoxifen and endoxifen plasma reached steady state at 30 day after tamoxifen dose escalation, with a significant increase compared to baseline by 1.6 to 1.8 fold : geometric mean plasma concentrations (CV %) were 140 ng/mL (45%) at baseline vs 255 (47%) at day 30 for tamoxifen (P < 0.0001); 256 (49%) vs 408 (64%) for N-desmethyltamoxifen (P < 0.0001); 2.4 (46%) vs 3.9 (51%) for 4-OH-tamoxifen (P < 0.0001); and 20 (91%) vs 33 (91%) for endoxifen (P < 0.02). On baseline, endoxifen levels tended to be lower in PM: 7 ng/mL (36%), than IM: 16 ng/mL (70%), P=0.08, and EM: 24 ng/mL (71%), P<0.001. After doubling tamoxifen dosage, endoxifen concentrations rose similarly in PM, IM and EM with respectively, 1.5 (18%), 1.5 (28%) and 1.7 (30%) fold increase from baseline, P=0.18. Conclusion: Endoxifen exposure varies widely under standard tamoxifen dosage, with CYP2D6 genotype explaining only a minor part of this variability. It increases consistently on doubling tamoxifen dose, similarly across genotypes. This would enable exposure optimization based on concentration monitoring.