140 resultados para corrected score


Relevância:

20.00% 20.00%

Publicador:

Resumo:

X-ray is a technology that is used for numerous applications in the medical field. The process of X-ray projection gives a 2-dimension (2D) grey-level texture from a 3- dimension (3D) object. Until now no clear demonstration or correlation has positioned the 2D texture analysis as a valid indirect evaluation of the 3D microarchitecture. TBS is a new texture parameter based on the measure of the experimental variogram. TBS evaluates the variation between 2D image grey-levels. The aim of this study was to evaluate existing correlations between 3D bone microarchitecture parameters - evaluated from μCT reconstructions - and the TBS value, calculated on 2D projected images. 30 dried human cadaveric vertebrae were acquired on a micro-scanner (eXplorer Locus, GE) at isotropic resolution of 93 μm. 3D vertebral body models were used. The following 3D microarchitecture parameters were used: Bone volume fraction (BV/TV), Trabecular thickness (TbTh), trabecular space (TbSp), trabecular number (TbN) and connectivity density (ConnD). 3D/2D projections has been done by taking into account the Beer-Lambert Law at X-ray energy of 50, 100, 150 KeV. TBS was assessed on 2D projected images. Correlations between TBS and the 3D microarchitecture parameters were evaluated using a linear regression analysis. Paired T-test is used to assess the X-ray energy effects on TBS. Multiple linear regressions (backward) were used to evaluate relationships between TBS and 3D microarchitecture parameters using a bootstrap process. BV/TV of the sample ranged from 18.5 to 37.6% with an average value at 28.8%. Correlations' analysis showedthat TBSwere strongly correlatedwith ConnD(0.856≤r≤0.862; p<0.001),with TbN (0.805≤r≤0.810; p<0.001) and negatively with TbSp (−0.714≤r≤−0.726; p<0.001), regardless X-ray energy. Results show that lower TBS values are related to "degraded" microarchitecture, with low ConnD, low TbN and a high TbSp. The opposite is also true. X-ray energy has no effect onTBS neither on the correlations betweenTBS and the 3Dmicroarchitecture parameters. In this study, we demonstrated that TBS was significantly correlated with 3D microarchitecture parameters ConnD and TbN, and negatively with TbSp, no matter what X-ray energy has been used. This article is part of a Special Issue entitled ECTS 2011. Disclosure of interest: None declared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Prevention of cardiovascular disease (CVD) at the individual level should rely on the assessment of absolute risk using population-specific risk tables. OBJECTIVE: To compare the predictive accuracy of the original and the calibrated SCORE functions regarding 10-year cardiovascular risk in Switzerland. DESIGN: Cross-sectional, population-based study (5773 participants aged 35-74 years). METHODS: The SCORE equation for low-risk countries was calibrated based on the Swiss CVD mortality rates and on the CVD risk factor levels from the study sample. The predicted number of CVD deaths after a 10-year period was computed from the original and the calibrated equations and from the observed cardiovascular mortality for 2003. RESULTS: According to the original and calibrated functions, 16.3 and 15.8% of men and 8.2 and 8.9% of women, respectively, had a 10-year CVD risk > or =5%. Concordance correlation coefficient between the two functions was 0.951 for men and 0.948 for women, both P<0.001. Both risk functions adequately predicted the 10-year cumulative number of CVD deaths: in men, 71 (original) and 74 (calibrated) deaths for 73 deaths when using the CVD mortality rates; in women, 44 (original), 45 (calibrated) and 45 (CVD mortality rates), respectively. Compared to the original function, the calibrated function classified more women and fewer men at high-risk. Moreover, the calibrated function gave better risk estimates among participants aged over 65 years. CONCLUSION: The original SCORE function adequately predicts CVD death in Switzerland, particularly for individuals aged less than 65 years. The calibrated function provides more reliable estimates for older individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With advances in the effectiveness of treatment and disease management, the contribution of chronic comorbid diseases (comorbidities) found within the Charlson comorbidity index to mortality is likely to have changed since development of the index in 1984. The authors reevaluated the Charlson index and reassigned weights to each condition by identifying and following patients to observe mortality within 1 year after hospital discharge. They applied the updated index and weights to hospital discharge data from 6 countries and tested for their ability to predict in-hospital mortality. Compared with the original Charlson weights, weights generated from the Calgary, Alberta, Canada, data (2004) were 0 for 5 comorbidities, decreased for 3 comorbidities, increased for 4 comorbidities, and did not change for 5 comorbidities. The C statistics for discriminating in-hospital mortality between the new score generated from the 12 comorbidities and the Charlson score were 0.825 (new) and 0.808 (old), respectively, in Australian data (2008), 0.828 and 0.825 in Canadian data (2008), 0.878 and 0.882 in French data (2004), 0.727 and 0.723 in Japanese data (2008), 0.831 and 0.836 in New Zealand data (2008), and 0.869 and 0.876 in Swiss data (2008). The updated index of 12 comorbidities showed good-to-excellent discrimination in predicting in-hospital mortality in data from 6 countries and may be more appropriate for use with more recent administrative data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The SYNTAX score (SXscore), an angiographic score reflecting coronary lesion complexity, predicts clinical outcomes in patients with left main or multivessel disease, and in patients with ST-segment elevation myocardial infarction undergoing primary PCI. The clinical SXscore (CSS) integrates the SXscore and clinical variables (age, ejection fraction, serum creatinine) into a single score. We analyzed these scores in elderly patients with acute coronary syndrome (ACS) undergoing primary PCI. The purpose of this analysis was not to decide which patients should undergo PCI, but to predict clinical outcomes in this population. METHODS: The SXscore was determined in a consecutive series of 114 elderly patients (mean age, 79.6 ± 4.1 years) undergoing primary PCI for ACS. Outcomes were stratified according to SXscore tertiles: SXLOW ≤15 (n = 39), 15< SXMID <23 (n = 40), and SXHIGH ≥23 (n = 35). The primary endpoint was all-cause mortality at 30 days. Secondary endpoints were nonfatal major adverse cardiac and cerebrovascular events (MACCE) at 30 days, and 1-year outcomes in patients discharged alive. RESULTS: Mortality at 30 days was higher in the SXHIGH group compared with the aggregate SXLOW+MID group (37.1% vs 5.1%; P<.0001), and in the CSSHIGH group compared with the aggregate CSSLOW+MID group (25.5% vs 1.4%; P=.0001). MACCE rates at 30 days were similar among SXscore tertiles. The CSS predicted 1-year MACCE rates (12.1% for CSSHIGH vs 3.1% for CSSLOW+MID; P=.03). CONCLUSIONS: The SXscore predicts 30-day mortality in elderly patients with ACS undergoing primary PCI. In patients discharged alive, the CSS predicts risk of MACCE at 1 year.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Guidelines for the prevention of coronary heart disease (CHD) recommend use of Framingham-based risk scores that were developed in white middle-aged populations. It remains unclear whether and how CHD risk prediction might be improved among older adults. We aimed to compare the prognostic performance of the Framingham risk score (FRS), directly and after recalibration, with refit functions derived from the present cohort, as well as to assess the utility of adding other routinely available risk parameters to FRS.¦METHODS: Among 2193 black and white older adults (mean age, 73.5 years) without pre-existing cardiovascular disease from the Health ABC cohort, we examined adjudicated CHD events, defined as incident myocardial infarction, CHD death, and hospitalization for angina or coronary revascularization.¦RESULTS: During 8-year follow-up, 351 participants experienced CHD events. The FRS poorly discriminated between persons who experienced CHD events vs. not (C-index: 0.577 in women; 0.583 in men) and underestimated absolute risk prediction by 51% in women and 8% in men. Recalibration of the FRS improved absolute risk prediction, particulary for women. For both genders, refitting these functions substantially improved absolute risk prediction, with similar discrimination to the FRS. Results did not differ between whites and blacks. The addition of lifestyle variables, waist circumference and creatinine did not improve risk prediction beyond risk factors of the FRS.¦CONCLUSIONS: The FRS underestimates CHD risk in older adults, particularly in women, although traditional risk factors remain the best predictors of CHD. Re-estimated risk functions using these factors improve accurate estimation of absolute risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectifs : Evaluer une méthode simple et rapide de mesure du volume atrial gauche. Matériels et méthodes : Cinquante patients ont été examinés avec un CT gaté pour mesure du score calcique. Trois méthodes ont été utilisées pour calculer le volume atrial gauche : 1) une méthode orthogonale avec mesure des surfaces/diamètres dans les plans axiaux/coronaux/sagittaux, 2) une méthode biplan inspirée de l'échocardiographie et 3) une méthode volumétrique. Les mesures ont été faites par le même observateur un mois plus tard et ont été répétées par trois autres observateurs. L'axe cardiaque a aussi été mesuré. La méthode Bland-Altmann et les corrélations de Spearman ont été utilisées. Résultats : La méthode volumétrique montre les variations intra/interobservateur les plus basses avec une variabilité de 6,1/7,4 ml, respectivement. Pour les mesures avec la méthode orthogonale (surfaces/diamètres), les variations intra/interobservateur sont 12,3/13,5 ml et 14,6/11,6 ml, respectivement. Pour la méthode biplan, les variations intra/interobservateur sont plus hautes : 23,9/19,8 ml. Comparée à la méthode de référence volumétrique, la méthode orthogonale avec les surfaces est mieux corrélée (R=0,959, p<0,001) que les autres méthodes. Il y a une faible influence de l'axe du coeur sur la méthode orthogonale avec les surfaces. Conclusion : La méthode volumétrique est le gold standard en terme de variabilité. Cependant elle est longue à metttre en oeuvre. La méthode orthogonale avec les surfaces est une alternative simple, sauf chez les patients obèses avec un coeur horizontalisé.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several cross-sectional studies have shown the ability of the TBS to discriminate between those with and without fractures in European populations. The aim of this study was to assess the ability of TBS to discriminate between those with and without fractures in a large female Caucasian population in the USA. This was a case-control study of 2,165 Caucasian American women aged 40 and older. Patients with illness or taking medications known to affect bone metabolism were excluded. Those in the fracture group (n = 289) had at least one low-energy fracture. BMD was measured at L1-L4, TBS calculated directly from the same DXA image. Descriptive statistics and inferential tests for difference were used. Univariate and multivariate logistic regression models were created to investigate possible association between independent variables and the status of fracture. Odds ratios per standard deviation decrease (OR) and areas under the ROC curve were calculated for discriminating parameters. Weak correlations were observed between TBS and BMD and between TBS and BMI (r = 0.33 and -0.17, respectively, p < 0.01). Mean age, weight, BMD and TBS were significantly different between control and fracture groups (all p ≤ 0.05), whereas no difference was noted for BMI or height. After adjusting for age, weight, BMD, smoking, and maternal and family history of fracture, TBS (but not BMD) remained a significant predictor of fracture: OR 1.28[1.13-1.46] even after adjustment. In a US female population, TBS again was able to discriminate between those with and those without fractures, even after adjusting for other clinical risk factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: An objective measurement of surgical procedures outcomes is inherent to professional practices quality control; this especially applies in orthopaedics to joint replacement outcomes. A self-administered questionnaire offers an attractive alternative to surgeon's judgement but is infrequently used in France for these purposes. The British questionnaire, the 12-item Oxford Hip Score (OHS) was selected for this study because of its ease of use. HYPOTHESIS: The objective of this study was to validate the French translation of the self-assessment 12-item Oxford Hip Score and compare its results with those of the reference functional scores: the Harris Hip Score (HHS) and the Postel-Merle d'Aubigné (PMA) score. MATERIALS AND METHODS: Based on a clinical series of 242 patients who were candidates for total hip arthroplasty, the French translation of this questionnaire was validated. Its coherence was also validated by comparing the preoperative data with the data obtained from the two other reference clinical scores. RESULTS: The translation was validated using the forward-backward translation procedure from French to English, with correction of all differences or mistranslations after systematized comparison with the original questionnaire in English. The mean overall OHS score was 43.8 points (range, 22-60 points) with similarly good distribution of the overall value of the three scores compared. The correlation was excellent between the OHS and the HHS, but an identical correlation between the OHS and the PMA was only obtained for the association of the pain and function parameters, after excluding the mobility criterion, relatively over-represented in the PMA score. DISCUSSION AND CONCLUSION: Subjective questionnaires that contribute a personal appreciation of the results of arthroplasty by the patient can easily be applied on a large scale. This study made a translated and validated version of an internationally recognized, reliable self-assessment score available to French orthopaedic surgeons. The results obtained encourage us to use this questionnaire as a complement to the classical evaluation scores and methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rationale: Life-threatening intraabdominal candidiasis (IAC) occurs in 30 to 40% of high-risk surgical intensive care unit (ICU) patients. Although early IAC diagnosis is crucial, blood cultures are negative, and the role of Candida score/colonization indexes is not established. Objectives: The aim of this prospective Fungal Infection Network of Switzerland (FUNGINOS) cohort study was to assess accuracy of 1,3-β-d-glucan (BG) antigenemia for diagnosis of IAC. Methods: Four hundred thirty-four consecutive adults with abdominal surgery or acute pancreatitis and ICU stay 72 hours or longer were screened: 89 (20.5%) at high risk for IAC were studied (68 recurrent gastrointestinal tract perforation, 21 acute necrotizing pancreatitis). Diagnostic accuracy of serum BG (Fungitell), Candida score, and colonization indexes was compared. Measurements and Main Results: Fifty-eight of 89 (65%) patients were colonized by Candida; 29 of 89 (33%) presented IAC (27 of 29 with negative blood cultures). Nine hundred twenty-one sera were analyzed (9/patient): median BG was 253 pg/ml (46-9,557) in IAC versus 99 pg/ml (8-440) in colonization (P < 0.01). Sensitivity and specificity of two consecutive BG measurements greater than or equal to 80 pg/ml were 65 and 78%, respectively. In recurrent gastrointestinal tract perforation it was 75 and 77% versus 90 and 38% (Candida score ≥ 3), 79 and 34% (colonization index ≥ 0.5), and 54 and 63% (corrected colonization index ≥ 0.4), respectively. BG positivity anticipated IAC diagnosis (5 d) and antifungal therapy (6 d). Severe sepsis/septic shock and death occurred in 10 of 11 (91%) and 4 of 11 (36%) patients with BG 400 pg/ml or more versus 5 of 18 (28%, P = 0.002) and 1 of 18 (6%, P = 0.05) with BG measurement less than 400 pg/ml. β-Glucan decreased in IAC responding to therapy and increased in nonresponse. Conclusions: BG antigenemia is superior to Candida score and colonization indexes and anticipates diagnosis of blood culture-negative IAC. This proof-of-concept observation in strictly selected high-risk surgical ICU patients deserves investigation of BG-driven preemptive therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The ASTRAL score was externally validated showing remarkable consistency on 3-month outcome prognosis in patients with acute ischemic stroke. The present study aimed to evaluate ASTRAL score's prognostic accuracy to predict 5-year outcome. METHODS: All consecutive patients with acute ischemic stroke registered in the Athens Stroke Registry between January 1, 1998, and December 31, 2010, were included. Patients were excluded if admitted >24 hours after symptom onset or if any ASTRAL score component was missing. End points were 5-year unfavorable functional outcome, defined as modified Rankin Scale 3 to 6, and 5-year mortality. For each outcome, the area under the receiver operating characteristics curve was calculated; also, a multivariate Cox proportional hazards analysis was performed to investigate whether the ASTRAL score was an independent predictor of outcome. The Kaplan-Meier product limit method was used to estimate the probability of 5-year survival for each ASTRAL score quartile. RESULTS: The area under the receiver operating characteristics curve of the score to predict 5-year unfavorable functional outcome was 0.89, 95% confidence interval 0.88 to 0.91. In multivariate Cox proportional hazards analysis, the ASTRAL score was independently associated with 5-year unfavorable functional outcome (hazard ratio, 1.09; 95% confidence interval, 1.08-1.10). The area under the receiver operating characteristics curve for the ASTRAL score's discriminatory power to predict 5-year mortality was 0.81 (95% confidence interval, 0.78-0.83). In multivariate analysis, the ASTRAL score was independently associated with 5-year mortality (hazard ratio, 1.09, 95% confidence interval, 1.08-1.10). During the 5-year follow-up, the probability of survival was significantly lower with increasing ASTRAL score quartiles (log-rank test <0.001). CONCLUSIONS: The ASTRAL score reliably predicts 5-year functional outcome and mortality in patients with acute ischemic stroke.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The McIsaac scoring system is a tool designed to predict the probability of streptococcal pharyngitis in children aged 3 to 17 years with a sore throat. Although it does not allow the physician to make the diagnosis of streptococcal pharyngitis, it enables to identify those children with a sore throat in whom rapid antigen detection tests have a good predictive value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractPurpose: to evaluate the tolerability, comfort and precision of the signal transmission of an ocular Sensor used for 24-hour intraocular pressure fluctuation monitoring in humans.Patients and methods: In this uncontrolled open trial involving 10 healthy volunteers an 8.7 mm radius prototype ocular telemetry Sensor (SENSIMED Triggerfish®, Lausanne, Switzerland) and an orbital bandage containing a loop antenna were applied and connected to a portable recorder after full eye examination. Best corrected visual acuity and position, surface wetting ability and mobility of the Sensor were assessed after 5 and 30 minutes, 4, 12 and 24 hours. Subjective wearing comfort was scored and activities documented in a logbook. After Sensor removal a full eye examination was repeated and the recorded signal analyzed.Results: The comfort score was high and did not fluctuate significantly over time. The mobility of the Sensor was limited across follow-up visits and its surface wetting ability remained good. Best corrected visual acuity was significantly reduced during Sensor wear and immediately after its removal (from 1.07 before, to 0.85 after, P-value 0.008). Three subjects developed a mild, transient corneal abrasion. In all but one participant we obtained usable data of a telemetric signal recording with sufficient sensitivity to depict ocular pulsation.Conclusions: This 24-hour- trial has encouraging results on the tolerability and functionality of the ocular telemetric Sensor for intraocular pressure fluctuation monitoring. Further studies with different Sensor radii conducted on a larger study population are needed to improve comfort, precision and interpretation of the telemetric signal.