44 resultados para centrifugal distortion


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective was to design a vascular phantom compatible with digital subtraction angiography, computerized tomography angiography, ultrasound and magnetic resonance angiography (MRA). Fiducial markers were implanted at precise known locations in the phantom to facilitate identification and orientation of plane views from three-dimensional (3-D) reconstructed images. A vascular conduit connected to tubing at the extremities of the phantom ran through an agar-based gel filling it. A vessel wall in latex was included around the conduit to avoid diffusion of contrast agents. Using a lost-material casting technique based on a low melting point metal, geometries of pathological vessels were modeled. During the experimental testing, fiducial markers were detectable in all modalities without distortion. No leak of gadolinium through the vascular wall was observed on MRA after 5 hours. Moreover, no significant deformation of the vascular conduit was noted during the fabrication process (confirmed by microtome slicing along the vessel). The potential use of the phantom for calibration, rescaling, and fusion of 3-D images obtained from the different modalities as well as its use for the evaluation of intra- and inter-modality comparative studies of imaging systems are discussed. In conclusion, the vascular phantom can allow accurate calibration of radiological imaging devices based on x-ray, magnetic resonance and ultrasound and quantitative comparisons of the geometric accuracy of the vessel lumen obtained with each of these methods on a given well defined 3-D geometry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To develop the understanding of innovation processes conceptualized in terms of asso- ciation through the "sociology of translation" (cf. actor-network theory) studies, this article analyses innovation processes in terms of dissociation and detachment mechanisms, exami- ning innovation through "withdrawal;" that is, innovation based on reducing or withdrawing use of a practice-"subtracting," "detaching"-a given artefact. Specifically, it focuses on the shift to farming techniques that have eliminated ploughing, bringing to light four major mechanisms constitutive of dissociation: centrifugal association; making entities and asso- ciations visible; making other entities and associations invisible; bringing together or "asso- ciating" new entities. The study helps refine our understanding of the detachment processes at work in innovation, shedding light in this particular case on transfers between public research institutes, industrial companies, farmers and citizens seeking to develop new farm production models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Meiotic drive has attracted much interest because it concerns the robustness of Mendelian segregation and its genetic and evolutionary stability. We studied chromosomal meiotic drive in the common shrew (Sorex araneus, Insectivora, Mammalia), which exhibits one of the most remarkable chromosomal polymorphisms within mammalian species. The open question of the evolutionary success of metacentric chromosomes (Robertsonian fusions) versus acrocentrics in the common shrew prompted us to test whether a segregation distortion in favor of metacentrics is present in female and/or male meiosis. Performing crosses under controlled laboratory conditions with animals from natural populations, we found a clear trend toward a segregation distortion in favor of metacentrics during male meiosis, two chromosome combinations (gm and jl) being significantly preferred over their acrocentric homologs. Apart for one Robertsonian fusion (hi), this trend was absent in female meiosis. We propose a model based on recombination events between twin acrocentrics to explain the difference in transmission ratios of the same metacentric in different sexes and unequal drive of particular metacentrics in the same sex. Pooled data for female and male meiosis revealed a trend toward stronger segregation distortion for larger metacentrics. This is partially in agreement with the frequency of metacentrics occurring in natural populations of a chromosome race showing a high degree of chromosomal polymorphism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A single coronary artery can complicate the surgical technique of arterial switch operations, impairing early and late outcomes. We propose a new surgical approach, successfully applied in a 2.1 kg neonate, aimed at reducing the risk of early and late compression and/or distortion of the newly constructed coronary artery system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rb fusions between acrocentric chromosomes leading to metacentrics tend to become fixed during the chromosomal evolution in the common shrew. Using microsatellite markers preliminary results show that populations are only slightly subdivided and genetic drift seems not to play an important role for the fixation of metacentrics. A significant segregation distortion in favour of metacentric chromosomes was found during male meiosis. This suggests that cytological factors such as facilitated fusion between acrocentric chromosomes or choice-effects at the level of gametes are more likely to play a role for the chromosomal evolution in the common shrew.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Recently, a compact cardiopulmonary support (CPS) system designed for quick set-up for example, during emergency cannulation, has been introduced. Traditional rectilinear percutaneous cannulas are standard for remote vascular access with the original design. The present study was designed to assess the potential of performance increase by the introduction of next-generation, self-expanding venous cannulas, which can take advantage of the luminal width of the venous vasculature despite a relatively small access orifice. METHODS: Veno-arterial bypass was established in three bovine experiments (69+/-10 kg). The Lifebridge (Lifebridge GmbH, Munich, Germany) system was connected to the right atrium in a trans-jugular fashion with various venous cannulas; and the oxygenated blood was returned through the carotid artery with a 17 F percutaneous cannula. Two different venous cannulas were studied, and the correlation between the centrifugal pump speed (1500-3900 RPM), flow and the required negative pressure on the venous side was established: (A) Biomedicus 19 F (Medtronic, Tolochenaz, Switzerland); (B) Smart canula 18 F/36 F (Smartcanula LLC, Lausanne, Switzerland). RESULTS: At 1500 RPM, the blood flow was 0.44+/-0.26 l min(-1) for the 19 F rectilinear cannula versus 0.73+/-0.34 l min(-1) for the 18/36 F self-expanding cannula. At 2500 RPM the blood flow was 1.63+/-0.62 l min(-1) for the 19F rectilinear cannula versus 2.13+/-0.34 l min(-1) for the 18/36 F self-expanding cannula. At 3500 RPM, the blood flow was 2.78+/-0.47 l min(-1) for the 19 F rectilinear cannula versus 3.64+/-0.39 l min(-1) for the 18/36 F self-expanding cannula (p<0.01 for 18/36 F vs 19 F). At 1500 RPM, the venous line pressure was 18+/-8 mmHg for the 19F rectilinear cannula versus 19+/-5 mmHg for the 18/36 F self-expanding cannula. At 2500 RPM the venous line pressure accounted for -22+/-32 mmHg for the 19 F rectilinear cannula versus 2+/-5 mmHg for the 18/36 F self-expanding cannula. At 3500 RPM, the venous line pressure was -112+/-42 mmHg for the rectilinear cannula versus 28+/-7 mmHg for the 18/36 F self-expanding cannula (p<0.01 for 18 F/36 F vs 19 F). Conclusions: The negative pressure required to achieve adequate venous drainage with the self-expanding venous cannula accounts for approximately 31% of the pressure necessary with the 19 F rectilinear cannula. In addition, a pump flow of more than 4 l min(-1) can be achieved with the self-expanding design and a well-accepted negative inlet pressure for minimal blood trauma of less than 50 mmHg.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Selective publication of studies, which is commonly called publication bias, is widely recognized. Over the years a new nomenclature for other types of bias related to non-publication or distortion related to the dissemination of research findings has been developed. However, several of these different biases are often still summarized by the term 'publication bias'. METHODS/DESIGN: As part of the OPEN Project (To Overcome failure to Publish nEgative fiNdings) we will conduct a systematic review with the following objectives:- To systematically review highly cited articles that focus on non-publication of studies and to present the various definitions of biases related to the dissemination of research findings contained in the articles identified.- To develop and discuss a new framework on nomenclature of various aspects of distortion in the dissemination process that leads to public availability of research findings in an international group of experts in the context of the OPEN Project.We will systematically search Web of Knowledge for highly cited articles that provide a definition of biases related to the dissemination of research findings. A specifically designed data extraction form will be developed and pilot-tested. Working in teams of two, we will independently extract relevant information from each eligible article.For the development of a new framework we will construct an initial table listing different levels and different hazards en route to making research findings public. An international group of experts will iteratively review the table and reflect on its content until no new insights emerge and consensus has been reached. DISCUSSION: Results are expected to be publicly available in mid-2013. This systematic review together with the results of other systematic reviews of the OPEN project will serve as a basis for the development of future policies and guidelines regarding the assessment and prevention of publication bias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

General Introduction These three chapters, while fairly independent from each other, study economic situations in incomplete contract settings. They are the product of both the academic freedom my advisors granted me, and in this sense reflect my personal interests, and of their interested feedback. The content of each chapter can be summarized as follows: Chapter 1: Inefficient durable-goods monopolies In this chapter we study the efficiency of an infinite-horizon durable-goods monopoly model with a fmite number of buyers. We find that, while all pure-strategy Markov Perfect Equilibria (MPE) are efficient, there also exist previously unstudied inefficient MPE where high valuation buyers randomize their purchase decision while trying to benefit from low prices which are offered once a critical mass has purchased. Real time delay, an unusual monopoly distortion, is the result of this attrition behavior. We conclude that neither technological constraints nor concern for reputation are necessary to explain inefficiency in monopolized durable-goods markets. Chapter 2: Downstream mergers and producer's capacity choice: why bake a larger pie when getting a smaller slice? In this chapter we study the effect of downstream horizontal mergers on the upstream producer's capacity choice. Contrary to conventional wisdom, we find anon-monotonic relationship: horizontal mergers induce a higher upstream capacity if the cost of capacity is low, and a lower upstream capacity if this cost is high. We explain this result by decomposing the total effect into two competing effects: a change in hold-up and a change in bargaining erosion. Chapter 3: Contract bargaining with multiple agents In this chapter we study a bargaining game between a principal and N agents when the utility of each agent depends on all agents' trades with the principal. We show, using the Potential, that equilibria payoffs coincide with the Shapley value of the underlying coalitional game with an appropriately defined characteristic function, which under common assumptions coincides with the principal's equilibrium profit in the offer game. Since the problem accounts for differences in information and agents' conjectures, the outcome can be either efficient (e.g. public contracting) or inefficient (e.g. passive beliefs).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To describe the anatomical characteristics and patterns of neurovascular compression in patients suffering classic trigeminal neuralgia (CTN), using high-resolution magnetic resonance imaging (MRI). MATERIALS AND METHODS: The analysis of the anatomy of the trigeminal nerve, brain stem and the vascular structures related to this nerve was made in 100 consecutive patients treated with a Gamma Knife radiosurgery for CTN between December 1999 and September 2004. MRI studies (T1, T1 enhanced and T2-SPIR) with axial, coronal and sagital simultaneous visualization were dynamically assessed using the software GammaPlan?. Three-dimensional reconstructions were also developed in some representative cases. RESULTS: In 93 patients (93%), there were one or several vascular structures in contact, either, with the trigeminal nerve, or close to its origin in the pons. The superior cerebellar artery was involved in 71 cases (76%). Other vessels identified were the antero-inferior cerebellar artery, the basilar artery, the vertebral artery, and some venous structures. Vascular compression was found anywhere along the trigeminal nerve. The mean distance between the nerve compression and the origin of the nerve in the brainstem was 3.76±2.9mm (range 0-9.8mm). In 39 patients (42%), the vascular compression was located proximally and in 42 (45%) the compression was located distally. Nerve dislocation or distortion by the vessel was observed in 30 cases (32%). CONCLUSIONS: The findings of this study are similar to those reported in surgical and autopsy series. This non-invasive MRI-based approach could be useful for diagnostic and therapeutic decisions in CTN, and it could help to understand its pathogenesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Venous cannula orifice obstruction is an underestimated problem during augmented cardiopulmonary bypass (CPB), which can potentially be reduced with redesigned, virtually wall-less cannula designs versus traditional percutaneous control venous cannulas. A bench model, allowing for simulation of the vena cava with various affluent orifices, venous collapse and a worst case scenario with regard to cannula position, was developed. Flow (Q) was measured sequentially for right atrial + hepatic + renal + iliac drainage scenarios, using a centrifugal pump and an experimental bench set-up (afterload 60 mmHg). At 1500, 2000 and 2500 RPM and atrial position, the Q values were 3.4, 6.03 and 8.01 versus 0.77*, 0.43* and 0.58* l/min: p<0.05* for wall-less and the Biomedicus(®) cannula, respectively. The corresponding pressure values were -15.18, -31.62 and -74.53 versus -46.0*, -119.94* and -228.13* mmHg. At the hepatic position, the Q values were 3.34, 6.67 and 9.26 versus 2.3*, 0.42* and 0.18* l/min; and the pressure values were -10.32, -20.25 and -42.83 versus -23.35*, -119.09* and -239.38* mmHg. At the renal position, the Q values were 3.43, 6.56 and 8.64 versus 2.48*, 0.41* and 0.22* l/min and the pressure values were -9.64, -20.98 and -63.41 versus -20.87 -127.68* and -239* mmHg, respectively. At the iliac position, the Q values were 3.43, 6.01 and 9.25 versus 1.62*, 0.55* and 0.58* l/min; the pressure values were -9.36, -33.57 and -44.18 versus -30.6*, -120.27* and -228* mmHg, respectivly. Our experimental evaluation demonstrates that the redesigned, virtually wall-less cannulas, allowing for direct venous drainage at practically all intra-venous orifices, outperform the commercially available control cannula, with superior flow at reduced suction levels for all scenarios tested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Violation of Mendel's Law of Segregation by selfish X chromosomes that favour their own transmission is known for a number of organisms. Now, a new study reveals sex-ratio distortion favouring males and explains previously puzzling sex ratios in a Mediterranean shrub.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bandura (1986) developed the concept of moral disengagement to explain how individuals can engage in detrimental behavior while experiencing low levels of negative feelings such as guilt-feelings. Most of the research conducted on moral disengagement investigated this concept as a global concept (e.g., Bandura, Barbaranelli, Caprara, & Pastorelli, 1996; Moore, Detert, Klebe Treviño, Baker, & Mayer, 2012) while Bandura (1986, 1990) initially developed eight distinct mechanisms of moral disengagement grouped into four categories representing the various means through which moral disengagement can operate. In our work, we propose to develop measures of this concept based on its categories, namely rightness of actions, rejection of personal responsibility, distortion of negative consequences, and negative perception of the victims, and which is not specific a particular area of research. Through our measures, we aim at better understanding the cognitive process leading individuals to behave unethically by investigating which category plays a role in explaining unethical behavior depending on the situations in which individuals are. To this purpose, we conducted five studies to develop the measures and to test its predictive validity. Particularly, we assessed the ability of the newly developed measures to predict two types of unethical behaviors, i.e. discriminatory behavior and cheating behavior. Confirmatory Factor analyses demonstrated a good fit of the model and findings generally supported our predictions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To develop the understanding of innovation processes conceptualized in terms of association through the "sociology of translation" (cf. actor-network theory) studies, this article analyses innovation processes in terms of dissociation and detachment mechanisms, examining innovation through "withdrawal"; that is, innovation based on reducing or withdrawing use of a practice - "subtracting", "detaching" - a given artefact. Specifically, it focuses on the shift to farming techniques that have eliminated ploughing, bringing to light four major mechanisms constitutive of dissociation : centrifugal association ; making entities and associations visible ; making other entities and associations invisible; bringing together or " associating " new entities. The study helps refine our understanding of the detachment processes at work in innovation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Concomitant aortic and mitral valve replacement or concomitant aortic valve replacement and mitral repair can be a challenge for the cardiac surgeon: in particular, because of their structure and design, two bioprosthetic heart valves or an aortic valve prosthesis and a rigid mitral ring can interfere at the level of the mitroaortic junction. Therefore, when a mitral bioprosthesis or a rigid mitral ring is already in place and a surgical aortic valve replacement becomes necessary, or when older high-risk patients require concomitant mitral and aortic procedures, the new 'fast-implantable' aortic valve system (Intuity valve, Edwards Lifesciences, Irvine, CA, USA) can represent a smart alternative to standard aortic bioprosthesis. Unfortunately, this is still controversial (risk of interference). However, transcatheter aortic valve replacements have been performed in patients with previously implanted mitral valves or mitral rings. Interestingly, we learned that there is no interference (or not significant interference) among the standard valve and the stent valve. Consequently, we can assume that a fast-implantable valve can also be safely placed next to a biological mitral valve or next to a rigid mitral ring without risks of distortion, malpositioning, high gradient or paravalvular leak. This paper describes two cases: a concomitant Intuity aortic valve and bioprosthetic mitral valve implantation and a concomitant Intuity aortic valve and mitral ring implantation.