47 resultados para Weighting
Resumo:
Introduction: Therapeutic drug monitoring (TDM) aims at optimizing treatment by individualizing dosage regimen based on measurement of blood concentrations. Maintaining concentrations within a target range requires pharmacokinetic and clinical capabilities. Bayesian calculation represents a gold standard in TDM approach but requires computing assistance. In the last decades computer programs have been developed to assist clinicians in this assignment. The aim of this benchmarking was to assess and compare computer tools designed to support TDM clinical activities.¦Method: Literature and Internet search was performed to identify software. All programs were tested on common personal computer. Each program was scored against a standardized grid covering pharmacokinetic relevance, user-friendliness, computing aspects, interfacing, and storage. A weighting factor was applied to each criterion of the grid to consider its relative importance. To assess the robustness of the software, six representative clinical vignettes were also processed through all of them.¦Results: 12 software tools were identified, tested and ranked. It represents a comprehensive review of the available software's characteristics. Numbers of drugs handled vary widely and 8 programs offer the ability to the user to add its own drug model. 10 computer programs are able to compute Bayesian dosage adaptation based on a blood concentration (a posteriori adjustment) while 9 are also able to suggest a priori dosage regimen (prior to any blood concentration measurement), based on individual patient covariates, such as age, gender, weight. Among those applying Bayesian analysis, one uses the non-parametric approach. The top 2 software emerging from this benchmark are MwPharm and TCIWorks. Other programs evaluated have also a good potential but are less sophisticated (e.g. in terms of storage or report generation) or less user-friendly.¦Conclusion: Whereas 2 integrated programs are at the top of the ranked listed, such complex tools would possibly not fit all institutions, and each software tool must be regarded with respect to individual needs of hospitals or clinicians. Interest in computing tool to support therapeutic monitoring is still growing. Although developers put efforts into it the last years, there is still room for improvement, especially in terms of institutional information system interfacing, user-friendliness, capacity of data storage and report generation.
Resumo:
Objectives: Therapeutic drug monitoring (TDM) aims at optimizing treatment by individualizing dosage regimen based on blood concentrations measurement. Maintaining concentrations within a target range requires pharmacokinetic (PK) and clinical capabilities. Bayesian calculation represents a gold standard in TDM approach but requires computing assistance. The aim of this benchmarking was to assess and compare computer tools designed to support TDM clinical activities.¦Methods: Literature and Internet were searched to identify software. Each program was scored against a standardized grid covering pharmacokinetic relevance, user-friendliness, computing aspects, interfacing, and storage. A weighting factor was applied to each criterion of the grid to consider its relative importance. To assess the robustness of the software, six representative clinical vignettes were also processed through all of them.¦Results: 12 software tools were identified, tested and ranked. It represents a comprehensive review of the available software characteristics. Numbers of drugs handled vary from 2 to more than 180, and integration of different population types is available for some programs. Nevertheless, 8 programs offer the ability to add new drug models based on population PK data. 10 computer tools incorporate Bayesian computation to predict dosage regimen (individual parameters are calculated based on population PK models). All of them are able to compute Bayesian a posteriori dosage adaptation based on a blood concentration while 9 are also able to suggest a priori dosage regimen, only based on individual patient covariates. Among those applying Bayesian analysis, MM-USC*PACK uses a non-parametric approach. The top 2 programs emerging from this benchmark are MwPharm and TCIWorks. Others programs evaluated have also a good potential but are less sophisticated or less user-friendly.¦Conclusions: Whereas 2 software packages are ranked at the top of the list, such complex tools would possibly not fit all institutions, and each program must be regarded with respect to individual needs of hospitals or clinicians. Programs should be easy and fast for routine activities, including for non-experienced users. Although interest in TDM tools is growing and efforts were put into it in the last years, there is still room for improvement, especially in terms of institutional information system interfacing, user-friendliness, capability of data storage and automated report generation.
Resumo:
Background: Post-surgical management of stage I seminoma includes: surveillance with repeated CT-scans and treatment reserved for those who relapse, or adjuvant treatment with either immediate radiation therapy (RT) or carboplatin. The cancer specific survival is close to 100%. Cure without long-term sequelae of treatment is the aim. Our goal is to estimate the risk of radiation-induced secondary cancers (SC) death from for patients undergoing S, adjuvant RT or adjuvant carboplatin (AC).Materials and Methods: We measured organ doses from CT scans (3 phases each one) of a seminoma patient who was part of the active surveillance strategy and from a man undergoing adjuvant RT 20-Gy and a 30-Gy salvage RT treatment to the para-aortic area using helical Intensity Modulated RT (Tomotherapy®) with accurate delineation of organs at risk and a CTV to PTV expansion of 1 cm. Effective doses to organs in mSv were estimated according to the tissue-weighting factors recommendations of the International Commission on Radiological Protection 103 (Ann ICRP 2007). We estimated SC incidence and mortality for a 10,000 people population based on the excess absolute risk model from the Biological Effects of Ionizing Radiation (BEIR) VII (Health Risk of Exposure to Low Levels of Ionizing Radiation, NCR, The National Academies Press Washington, DC, 2006) assuming a seminoma diagnosis at age 30, a total life expectancy of 80 years.Results: The nominal risk for a fatal secondary cancers was calculated 1.5% for 15 abdominal CT scans, 14.8% for adjuvant RT (20 Gy paraaortic field) and 22.2% for salvage RT (30 Gy). The calculation assumed that the risk of relapse on surveillance and adjuvant AC was 15% and 4% respectively and that all patients were salvaged at relapse with RT. n CT abdomen/Pelvis = secondary cancer % RT Dose and % receiving treatment = secondary cancer % Total secondary cancer risk in % Active surveillance 15 = 1.5% 30 Gy in 15% of pts = 3.3% 4.8 Adjuvant carboplatin 7 = 0.7% 30 Gy in 4% of pts = 0.88% 1.58 Adjuvant radiotherapy 7 = 0.7% 20 Gy in 100% of pts = 14.8% 15.5Conclusions: These data suggest that: 1) Adjuvant radiotherapy is harmful and should not anymore be regarded as a standard option for seminoma stage I. 2) AC seems to be an option to reduce radiation induced cancers. Limitations: the study does not consider secondary cancers due to chemotherapy with AC (unknown). The use of BEIR VII for risk modeling with higher doses of RT needs to be validated.
Resumo:
A T(2) magnetization-preparation (T(2) Prep) sequence is proposed that is insensitive to B(1) field variations and simultaneously provides fat suppression without any further increase in specific absorption rate (SAR). Increased B(1) inhomogeneity at higher magnetic field strength (B(0) > or = 3T) necessitates a preparation sequence that is less sensitive to B(1) variations. For the proposed technique, T(2) weighting in the image is achieved using a segmented B(1)-insensitive rotation (BIR-4) adiabatic pulse by inserting two equally long delays, one after the initial reverse adiabatic half passage (AHP), and the other before the final AHP segment of a BIR-4 pulse. This sequence yields T(2) weighting with both B(1) and B(0) insensitivity. To simultaneously suppress fat signal (at the cost of B(0) insensitivity), the second delay is prolonged so that fat accumulates additional phase due to its chemical shift. Numerical simulations as well as phantom and in vivo image acquisitions were performed to show the efficacy of the proposed technique.
Resumo:
Background: b-value is the parameter characterizing the intensity of the diffusion weighting during image acquisition. Data acquisition is usually performed with low b value (b~1000 s/mm2). Evidence shows that high b-values (b>2000 s/mm2) are more sensitive to the slow diffusion compartment (SDC) and maybe more sensitive in detecting white matter (WM) anomalies in schizophrenia.Methods: 12 male patients with schizophrenia (mean age 35 +/-3 years) and 16 healthy male controls matched for age were scanned with a low b-value (1000 s/mm2) and a high b-value (4000 s/mm2) protocol. Apparent diffusion coefficient (ADC) is a measure of the average diffusion distance of water molecules per time unit (mm2/s). ADC maps were generated for all individuals. 8 region of interests (frontal and parietal region bilaterally, centrum semi-ovale bilaterally and anterior and posterior corpus callosum) were manually traced blind to diagnosis.Results: ADC measures acquired with high b-value imaging were more sensitive in detecting differences between schizophrenia patients and healthy controls than low b-value imaging with a gain in significance by a factor of 20- 100 times despite the lower image Signal-to-noise ratio (SNR). Increased ADC was identified in patient's WM (p=0.00015) with major contributions from left and right centrum semi-ovale and to a lesser extent right parietal region.Conclusions: Our results may be related to the sensitivity of high b-value imaging to the SDC believed to reflect mainly the intra-axonal and myelin bound water pool. High b-value imaging might be more sensitive and specific to WM anomalies in schizophrenia than low b-value imaging
Resumo:
Relaxation rates provide important information about tissue microstructure. Multi-parameter mapping (MPM) estimates multiple relaxation parameters from multi-echo FLASH acquisitions with different basic contrasts, i.e., proton density (PD), T1 or magnetization transfer (MT) weighting. Motion can particularly affect maps of the apparent transverse relaxation rate R2(*), which are derived from the signal of PD-weighted images acquired at different echo times. To address the motion artifacts, we introduce ESTATICS, which robustly estimates R2(*) from images even when acquired with different basic contrasts. ESTATICS extends the fitted signal model to account for inherent contrast differences in the PDw, T1w and MTw images. The fit was implemented as a conventional ordinary least squares optimization and as a robust fit with a small or large confidence interval. These three different implementations of ESTATICS were tested on data affected by severe motion artifacts and data with no prominent motion artifacts as determined by visual assessment or fast optical motion tracking. ESTATICS improved the quality of the R2(*) maps and reduced the coefficient of variation for both types of data-with average reductions of 30% when severe motion artifacts were present. ESTATICS can be applied to any protocol comprised of multiple 2D/3D multi-echo FLASH acquisitions as used in the general research and clinical setting.
Resumo:
Diffusion-weighting in magnetic resonance imaging (MRI) increases the sensitivity to molecular Brownian motion, providing insight in the micro-environment of the underlying tissue types and structures. At the same time, the diffusion weighting renders the scans sensitive to other motion, including bulk patient motion. Typically, several image volumes are needed to extract diffusion information, inducing also inter-volume motion susceptibility. Bulk motion is more likely during long acquisitions, as they appear in diffusion tensor, diffusion spectrum and q-ball imaging. Image registration methods are successfully used to correct for bulk motion in other MRI time series, but their performance in diffusion-weighted MRI is limited since diffusion weighting introduces strong signal and contrast changes between serial image volumes. In this work, we combine the capability of free induction decay (FID) navigators, providing information on object motion, with image registration methodology to prospectively--or optionally retrospectively--correct for motion in diffusion imaging of the human brain. Eight healthy subjects were instructed to perform small-scale voluntary head motion during clinical diffusion tensor imaging acquisitions. The implemented motion detection based on FID navigator signals is processed in real-time and provided an excellent detection performance of voluntary motion patterns even at a sub-millimetre scale (sensitivity≥92%, specificity>98%). Motion detection triggered an additional image volume acquisition with b=0 s/mm2 which was subsequently co-registered to a reference volume. In the prospective correction scenario, the calculated motion-parameters were applied to perform a real-time update of the gradient coordinate system to correct for the head movement. Quantitative analysis revealed that the motion correction implementation is capable to correct head motion in diffusion-weighted MRI to a level comparable to scans without voluntary head motion. The results indicate the potential of this method to improve image quality in diffusion-weighted MRI, a concept that can also be applied when highest diffusion weightings are performed.
Resumo:
Background and Aims: The international EEsAI study group aims to develop, validate and evaluate the first pediatric EoE activity index (ped-EEsAI). We report on results of phase 1, which aims to generate candidate items. Methods: This study involves 3 phases: (1) item generation, (2) index derivation and testing on a first patient cohort, and (3) validation in a second cohort. In phase 1, item generation, weighting and reduction are achieved through a Delphi process with an international EoE expert group. The experts proposed and ranked candidate items on a 7-point Likert scale (0 = no, 6 = perfect relationship with EoE activity). Results: 23 international EoE experts proposed and ranked 39 items (20 clinical, 6 endoscopic, 8 histologic, 5 laboratory items). Rank order for clinical items: dysphagia related to food consistencies (median 5, range 2-6), severity of dysphagia (5, 3-6), frequency of dysphagia episodes (5, 3-6), regurgitation and vomiting (4, 2-5), response to dietary restrictions (4, 1-6); endoscopic items: whitish exudates (5, 3-6), furrowing (4, 3-6), corrugated rings (4, 2-6), linear shearing (4, 2-6), strictures (3, 2-6); histologic items: intraepithelial eosinophil count (5, 4-6), lamina propria fibrosis (3, 2-6), basal layer enlargement (3, 1-5); laboratory items: % blood eosinophils (3, 0-5). Conclusions: These items will now be reduced in further Delphi rounds, tested on a cohort of 100 pediatric EoE patients and validated in a second independent cohort, resulting in a robust, broadly accepted disease activity index for use in clinical trials and daily care.
Resumo:
INTRODUCTION: Video records are widely used to analyze performance in alpine skiing at professional or amateur level. Parts of these analyses require the labeling of some movements (i.e. determining when specific events occur). If differences among coaches and differences for the same coach between different dates are expected, they have never been quantified. Moreover, knowing these differences is essential to determine which parameters reliable should be used. This study aimed to quantify the precision and the repeatability for alpine skiing coaches of various levels, as it is done in other fields (Koo et al, 2005). METHODS: A software similar to commercialized products was designed to allow video analyses. 15 coaches divided into 3 groups (5 amateur coaches (G1), 5 professional instructors (G2) and 5 semi-professional coaches (G3)) were enrolled. They were asked to label 15 timing parameters (TP) according to the Swiss ski manual (Terribilini et al, 2001) for each curve. TP included phases (initiation, steering I-II), body and ski movements (e.g. rotation, weighting, extension, balance). Three video sequences sampled at 25 Hz were used and one curve per video was labeled. The first video was used to familiarize the analyzer to the software. The two other videos, corresponding to slalom and giant slalom, were considered for the analysis. G1 realized twice the analysis (A1 and A2) at different dates and TP were randomized between both analyses. Reference TP were considered as the median of G2 and G3 at A1. The precision was defined as the RMS difference between individual TP and reference TP, whereas the repeatability was calculated as the RMS difference between individual TP at A1 and at A2. RESULTS AND DISCUSSION: For G1, G2 and G3, a precision of +/-5.6 frames, +/-3.0 and +/-2.0 frames, was respectively obtained. These results showed that G2 was more precise than G1, and G3 more precise than G2, were in accordance with group levels. The repeatability for G1 was +/-3.1 frames. Furthermore, differences among TP precision were observed, considering G2 and G3, with largest differences of +/-5.9 frames for "body counter rotation movement in steering phase II", and of 0.8 frame for "ski unweighting in initiation phase". CONCLUSION: This study quantified coach ability to label video in term of precision and repeatability. The best precision was obtained for G3 and was of +/-0.08s, which corresponds to +/-6.5% of the curve cycle. Regarding the repeatability, we obtained a result of +/-0.12s for G1, corresponding to +/-12% of the curve cycle. The repeatability of G2 and G3 are expected to be lower than the precision of G1 and the corresponding repeatability will be assessed soon. In conclusion, our results indicate that the labeling of video records is reliable for some TP, whereas caution is required for others. REFERENCES Koo S, Gold MD, Andriacchi TP. (2005). Osteoarthritis, 13, 782-789. Terribilini M, et al. (2001). Swiss Ski manual, 29-46. IASS, Lucerne.
Resumo:
BACKGROUND: The escalating prevalence of obesity might prompt obese subjects to consider themselves as normal, as this condition is gradually becoming as frequent as normal weight. In this study, we aimed to assess the trends in the associations between obesity and self-rated health in two countries. METHODS: Data from the Portuguese (years 1995-6, 1998-6 and 2005-6) and Swiss (1992-3, 1997, 2002 and 2007) National Health Surveys were used, corresponding to more than 130,000 adults (64,793 for Portugal and 65,829 for Switzerland). Body mass index and self-rated health were derived from self-reported data. RESULTS: Obesity levels were higher in Portugal (17.5% in 2005-6 vs. 8.9% in 2007 in Switzerland, p < 0.001) and increased in both countries. The prevalence of participants rating their health as "bad" or "very bad" was higher in Portugal than in Switzerland (21.8% in 2005-6 vs 3.9% in 2007, p < 0.001). In both countries, obese participants rated more frequently their health as "bad" or "very bad" than participants with regular weight. In Switzerland, the prevalence of "bad" or "very bad" rates among obese participants, increased from 6.5% in 1992-3 to 9.8% in 2007, while in Portugal it decreased from 41.3% to 32.3%. After multivariate adjustment, the odds ratio (OR) of stating one self's health as "bad" or "very bad" among obese relative to normal weight participants, almost doubled in Switzerland: from 1.38 (95% confidence interval, CI: 1.01-1.87) in 1992-3 to 2.64 (95% CI: 2.14-3.26) in 2007, and similar findings were obtained after sample weighting. Conversely, no such trend was found in Portugal: 1.35 (95% CI: 1.23-1.48) in 1995-6 and 1.52 (95% CI: 1.37-1.70) in 2005-6. CONCLUSION: Obesity is increasing in Switzerland and Portugal. Obesity is increasingly associated with poorer self-health ratings in Switzerland but not in Portugal.
Resumo:
OBJECTIVE: To estimate the effect of combined antiretroviral therapy (cART) on mortality among HIV-infected individuals after appropriate adjustment for time-varying confounding by indication. DESIGN: A collaboration of 12 prospective cohort studies from Europe and the United States (the HIV-CAUSAL Collaboration) that includes 62 760 HIV-infected, therapy-naive individuals followed for an average of 3.3 years. Inverse probability weighting of marginal structural models was used to adjust for measured confounding by indication. RESULTS: Two thousand and thirty-nine individuals died during the follow-up. The mortality hazard ratio was 0.48 (95% confidence interval 0.41-0.57) for cART initiation versus no initiation. In analyses stratified by CD4 cell count at baseline, the corresponding hazard ratios were 0.29 (0.22-0.37) for less than 100 cells/microl, 0.33 (0.25-0.44) for 100 to less than 200 cells/microl, 0.38 (0.28-0.52) for 200 to less than 350 cells/microl, 0.55 (0.41-0.74) for 350 to less than 500 cells/microl, and 0.77 (0.58-1.01) for 500 cells/microl or more. The estimated hazard ratio varied with years since initiation of cART from 0.57 (0.49-0.67) for less than 1 year since initiation to 0.21 (0.14-0.31) for 5 years or more (P value for trend <0.001). CONCLUSION: We estimated that cART halved the average mortality rate in HIV-infected individuals. The mortality reduction was greater in those with worse prognosis at the start of follow-up.
Resumo:
Introduction: The pharmaceutical aspects of drug administration in clinical trials receive poor consideration compared with the important attention devoted to the analytical and mathematical aspects of biological sample exploitation. During PK calculations, many researchers merely use for dose the nominal amount declared, overlooking the noticeable biases that may result in the assessment of PK parameters. The aim of this work was to evaluate the biases related to doses injected of a biosimilar drug in 2 Phase I clinical trials. Patients (or Materials) and Methods: In trial A, 12 healthy volunteers received different doses of a biosimilar of interferon beta-1a by either subcutaneous (SC) or intravenous (IV) injection. The doses were prepared by partially emptying 0.5-mL syringes supplied by the manufacturer (drop count procedure). In trial B, 12 healthy volunteers received 3 different formulations of the drug by IV injection (biosimilar without albumin [HSA], biosimilar with HSA and original brand [Rebif®]) and 2 different formulations as multiple SC injections (biosimilar HSA-free and original brand). In both trials, the actual dose administered was calculated as: D = C·V - losses. The product titer C was assessed by ELISA. The volume administered IV was assessed by weighting. Losses were evaluated by in vitro experiments. Finally, the binding of 125I-interferon to HSA was evaluated by counting the free and HSA complexed molecule fractions separated by gel filtration. Results: Interferon was not significantly adsorbed onto the lines used for its IV administration. In trial A, the titer was very close to the one declared (96 ± 7%). In trial B, it differed significantly (156 ± 10% for biosimilar with/without HSA and 123 ± 5% for original formulation). In trial A, the dose actually administered showed a large variability. The real injected volume could be biased up to 75% compared with the theoretical volume (for the lower dose administered [ie, 0.03 mL]). This was mainly attributed to a partial re-aspiration of the drug solution before withdrawing the syringe needle. A strict procedure was therefore applied in trial B to avoid these inaccuracies. Finally, in trial B, 125I-Interferon beta-1a binding to HSA appeared time dependent and slow, reaching 50% after 16-hour incubation, which is close to steady state reported for the comparator Rebif®. Conclusion: These practical examples (especially biases on actual titer and volume injected) illustrate that actual dose assessment deserves attention to ensure accuracy for estimates of clearance and distribution volume in the scientific literature and for registration purposes, especially for bioequivalence studies.
Resumo:
IMPORTANCE: There are limited prospective, controlled data evaluating survival in patients receiving early surgery vs medical therapy for prosthetic valve endocarditis (PVE). OBJECTIVE: To determine the in-hospital and 1-year mortality in patients with PVE who undergo valve replacement during index hospitalization compared with patients who receive medical therapy alone, after controlling for survival and treatment selection bias. DESIGN, SETTING, AND PARTICIPANTS: Participants were enrolled between June 2000 and December 2006 in the International Collaboration on Endocarditis-Prospective Cohort Study (ICE-PCS), a prospective, multinational, observational cohort of patients with infective endocarditis. Patients hospitalized with definite right- or left-sided PVE were included in the analysis. We evaluated the effect of treatment assignment on mortality, after adjusting for biases using a Cox proportional hazards model that included inverse probability of treatment weighting and surgery as a time-dependent covariate. The cohort was stratified by probability (propensity) for surgery, and outcomes were compared between the treatment groups within each stratum. INTERVENTIONS: Valve replacement during index hospitalization (early surgery) vs medical therapy. MAIN OUTCOMES AND MEASURES: In-hospital and 1-year mortality. RESULTS: Of the 1025 patients with PVE, 490 patients (47.8%) underwent early surgery and 535 individuals (52.2%) received medical therapy alone. Compared with medical therapy, early surgery was associated with lower in-hospital mortality in the unadjusted analysis and after controlling for treatment selection bias (in-hospital mortality: hazard ratio [HR], 0.44 [95% CI, 0.38-0.52] and lower 1-year mortality: HR, 0.57 [95% CI, 0.49-0.67]). The lower mortality associated with surgery did not persist after adjustment for survivor bias (in-hospital mortality: HR, 0.90 [95% CI, 0.76-1.07] and 1-year mortality: HR, 1.04 [95% CI, 0.89-1.23]). Subgroup analysis indicated a lower in-hospital mortality with early surgery in the highest surgical propensity quintile (21.2% vs 37.5%; P = .03). At 1-year follow-up, the reduced mortality with surgery was observed in the fourth (24.8% vs 42.9%; P = .007) and fifth (27.9% vs 50.0%; P = .007) quintiles of surgical propensity. CONCLUSIONS AND RELEVANCE: Prosthetic valve endocarditis remains associated with a high 1-year mortality rate. After adjustment for differences in clinical characteristics and survival bias, early valve replacement was not associated with lower mortality compared with medical therapy in the overall cohort. Further studies are needed to define the effect and timing of surgery in patients with PVE who have indications for surgery.
Resumo:
PURPOSE: To combine weighted iterative reconstruction with self-navigated free-breathing coronary magnetic resonance angiography for retrospective reduction of respiratory motion artifacts. METHODS: One-dimensional self-navigation was improved for robust respiratory motion detection and the consistency of the acquired data was estimated on the detected motion. Based on the data consistency, the data fidelity term of iterative reconstruction was weighted to reduce the effects of respiratory motion. In vivo experiments were performed in 14 healthy volunteers and the resulting image quality of the proposed method was compared to a navigator-gated reference in terms of acquisition time, vessel length, and sharpness. RESULT: Although the sampling pattern of the proposed method contained 60% more samples with respect to the reference, the scan efficiency was improved from 39.5 ± 10.1% to 55.1 ± 9.1%. The improved self-navigation showed a high correlation to the standard navigator signal and the described weighting efficiently reduced respiratory motion artifacts. Overall, the average image quality of the proposed method was comparable to the navigator-gated reference. CONCLUSION: Self-navigated coronary magnetic resonance angiography was successfully combined with weighted iterative reconstruction to reduce the total acquisition time and efficiently suppress respiratory motion artifacts. The simplicity of the experimental setup and the promising image quality are encouraging toward future clinical evaluation. Magn Reson Med 73:1885-1895, 2015. © 2014 Wiley Periodicals, Inc.
Resumo:
PURPOSE: to assess the trends of prevalence of self-reported cardiovascular risk factors (CV RFs: hypertension, hypercholesterolemia, diabetes) and their management for the period of 1992 to 2007 in Switzerland. METHODS: four health interview surveys conducted between 1992 and 2007 in representative samples of the Swiss population (63,782 subjects overall). Self-reported CV RFs prevalence, treatment and control levels were computed after weighting. Weights were calculated by raking ratio such that the marginal distribution of the weighted totals conforms to the marginal distribution of the target population. Multivariate analysis was conducted using logistic regression. RESULTS: prevalence of all CV RFs increased between 1992 and 2007. Also, the prevalence of self-reported treatment among subjects with CV RFs increased, as confirmed by multivariate analysis: OR for hypolipidemic treatment relative to 1992: 0.64 [0.52-0.78]; 1.39 [1.18-1.65] and 2.00 [1.69-2.36] for 1997, 2002 and 2007, respectively. Still, in 2007, circa 40% of hypertensive, 60% of hypercholesterolemic and 50% of diabetic subjects weren't treated. On the other hand, there is an increase of the prevalence of controlled RFs as reported by treated subjects. This was confirmed by multivariate analysis 12.1 [12.0 - 12.2]; 4.16 [4.1 - 4.23] and 2.85 [2.79 - 2.90] for hypertension, hypercholesterolemia and diabetes, respectively, in 2007, relative to 1992. CONCLUSION: the prevalence of self-reported hypertension, hypercholesterolemia and diabetes increased between 1992 and 2007 in the Swiss population. Despite a good control of treated subjects, still a significant percentage of subjects with CV RFs are not treated.