110 resultados para Wall materials
Resumo:
To assess the behavior of the arterial wall in hypertensive patients, we developed a noninvasive ultrasonic device. Simultaneous recordings of internal diameter and blood pressure over the whole cardiac cycle are used to establish compliance-pressure curves. Blood pressure, which is a co-determinant of compliance, is thus taken into account. This method allows one to compare arteries from patients with different blood pressures. Arterial compliance and distensibility were first investigated in healthy young volunteers administered either lisinopril (20 mg), atenolol (100 mg) or nitrendipine (20 mg) once a day. After 8 days of treatment, only lisinopril was found to increase arterial compliance. Subsequently, we compared arterial diameter- and distensibility-pressure curves from newly diagnosed and untreated hypertensive patients with those of matched normotensive control patients. Diameter-pressure curves did not differ significantly between the groups and distensibility was not reduced. Similar findings were later obtained in an animal model, when mechanical properties of carotid arteries were compared between spontaneously hypertensive rats and normotensive counterparts (Wistar-Kyoto rats). These results, although interesting by providing noninvasive information on the elastic response of the wall, call for further development of the technique to be able to measure arterial wall thickness. Stress-strain relationship could ultimately be established to thoroughly characterize physical properties of blood vessel walls.
Resumo:
BACKGROUND AND OBJECTIVE: Off-pump coronary artery bypass grafting has stimulated the development of micro-pumps designed to prevent the hemodynamic instability induced by heart luxation for the exposure of target vessels of the posterior wall. Impella (Aachen, Germany) developed micro-pumps with a miniaturized propeller system for both sides of the heart. The aim of this study was to analyze the impact of both pumps working together on blood cell integrity. MATERIALS AND METHODS: Both right and left-sided micro-pumps were implanted in 5 calves (body weight, 72_4 Kg) during 3 h. Blood samples for hematology and hemolysis parameters were drawn hourly. RESULTS: Both pumps performed well with a flow of 3.6 L +/- 0.3 L during the 3 h of the experiment with stable hemodynamic conditions. Mixed venous oxygen saturation was 63.4 +/- 15.2% at baseline and 63.8 +/- 16.3% at the end of the experiment (P = ns). Red cell count, LDH and free plasma hemoglobin were 6.7 +/- 2.1 x 10(12)/L, 1807 +/- 437 IU/L, and 32 +/- 9 mg/L at baseline vs. 6.1 +/- 2.1 x 10(12)/L, 1871 +/- 410 IU/L, and 52 +/- 9 mg/L at the end of the experiment (P = ns for all comparisons). Platelet count exhibited a non-significant drop (872 +/- 126 vs. 715 +/- 22 x 10(9)/L). CONCLUSIONS: This double pump system based on the Archimed screw principle is hematologically well tolerated under conditions of prolonged cardiac assist.
Resumo:
BACKGROUND AND OBJECTIVE: In bladder cancer, conventional white light endoscopic examination of the bladder does not provide adequate information about the presence of "flat" urothelial lesions such as carcinoma in situ. In the present investigation, we examine a new technique for the photodetection of such lesions by the imaging of protoporphyrin IX (PpIX) fluorescence following topical application of 5-aminolevulinic acid (ALA). STUDY DESIGN/MATERIALS AND METHODS: Several hours after bladder instillation of an aqueous solution of ALA in 34 patients, a Krypton ion laser or a filtered Xenon arc-lamp was used to excite PpIX fluorescence. Tissue samples for histological analysis were taken while observing the bladder wall either by means of a video camera, or by direct endoscopic observation. RESULTS: A good correlation was found between the PpIX fluorescence and the histopathological diagnosis. On a total of 215 biopsies, 143 in fluorescent and 72 in nonfluorescent areas, all visible tumors on white light cytoscopy appeared in a bright red fluorescence with the photodetection technique. In addition, this method permitted to discover 47 unsuspected carcinomatous lesions on white light observation, among which 40% were carcinoma in situ. CONCLUSION: PpIX fluorescence induced by instillation into the bladder of 5-ALA is an efficient method of mapping the mucosa in bladder carcinoma.
Resumo:
PURPOSE: To investigate the potential of free-breathing 3D steady-state free precession (SSFP) imaging with radial k-space sampling for coronary MR-angiography (MRA), coronary projection MR-angiography and coronary vessel wall imaging. MATERIALS AND METHODS: A navigator-gated free-breathing T2-prepared 3D SSFP sequence (TR = 6.1 ms, TE = 3.0 ms, flip angle = 120 degrees, field-of-view = 360 mm(2)) with radial k-space sampling (384 radials) was implemented for coronary MRA. For projection coronary MRA, this sequence was combined with a 2D selective aortic spin tagging pulse. Coronary vessel wall imaging was performed using a high-resolution inversion-recovery black-blood 3D radial SSFP sequence (384 radials, TR = 5.3 ms, TE = 2.7 ms, flip angle = 55 degrees, reconstructed resolution 0.35 x 0.35 x 1.2 mm(3)) and a local re-inversion pulse. Six healthy volunteers (two for each sequence) were investigated. Motion artifact level was assessed by two radiologists. Results: In coronary MRA, the coronary lumen was displayed with a high signal and high contrast to the surrounding lumen. Projection coronary MRA demonstrated selective visualization of the coronary lumen while surrounding tissue was almost completely suppressed. In coronary vessel wall imaging, the vessel wall was displayed with a high signal when compared to the blood pool and the surrounding tissue. No visible motion artifacts were seen. Conclusion: 3D radial SSFP imaging enables coronary MRA, coronary projection MRA and coronary vessel wall imaging with a low motion artifact level.
Resumo:
Introduction: The use of bioabsorbable materials for orthopaedic useand traumatic fracture fixation in children has been poorly investigatedin the litterature and the effects on growing bones seem contradictory.The aim of the study is to compare the clinical and radiological resultsand evolution between bioabsorbable and traditional K-Wires for thetreatment of elbow epiphyseal fractures in children.Method: From jan. 2008 to Dec. 2009 21 children with similar fracturesand age were separated in two groups according to the way of fracturefixation: bioabsorbable K-Wire group and traditional K-Wire group.Follow-up was done at 3, 6 and 12 month post-operatively. Range ofmotion and elbow stability were measured for all patients. Theradiological evolution of the two groups were compared in term ofconsolidation, ossous resorption and radiolucencies. The clinicalresults were compared according to the Mayo Elbow Peformancescore. Controlateral elbow is compared with injured elbow in the twogroups.Results: In the bioabsorbable K-wire group, there were 10 children,including 5 girles and 5 boys with an average age of 9.5 years, rangingfrom 5 to 14 years. They were 7 external condylar fractures and3 epitrochlear fractures. In the traditional K-Wire group there were11 children, 2 girls and 9 boys with an average age of 7.6 years,ranging from 4 to 14 years. There were 10 external condylar fracturesand 1 epitrochlear fracture. At first follow up. The Mayo ElbowPerformance score was 93.8 (85-100 )for the bioabsorbable K-Wiregroup and 95.5 (85-100) for the traditional K-Wire group. In twochildren from the bioabsorbable K-Wire group there were transitoryradiolucencies along the wire tract on the x-ray, without clinicalmanifestation of it.We didn't see any premature closure of growingcartilage.Discussion: There is no significant differencies in term of clinical andradiological outcome between the two groups. The use ofbioabsorbable pins seems to be a good alternative to removabletraditional materials, avoiding a second operation.
Resumo:
The aim of this study was to compare clinical and radiological outcome of lateral condyle fracture of the elbow in children treated with bioabsorbable or metallic material. From January 2008 to December 2009, 16 children with similar fractures and ages were grouped according to the fixation material used. Children were seen at 3, 6, and 12 months and more than 4 years (mean 51.8 months) postoperatively. The clinical results were compared using the Mayo Elbow Performance Score (MEPS). Radiographic studies of the fractured and opposite elbow were assessed at last follow-up control. Twelve children had a sufficient followup and could be included in the study. Seven could be included in the traditional group and 5 in the bioabsorbable group. At 12 months, the MEPS was 100 for every child in both groups. Asymptomatic bony radiolucent visible tracks and heterotopic ossifications were noted in both groups. There were no significant differences in terms of clinical and radiological outcome between the two groups. The use of bioabsorbable pins or screws is a reasonable alternative to the traditional use of metallic materials for the treatment of lateral condyle fracture of the elbow in children.
Resumo:
PURPOSE: To determine the relationship between carotid intima-media thickness (IMT), coronary artery calcification (CAC), and myocardial blood flow (MBF) at rest and during vasomotor stress in type 2 diabetes mellitus (DM). METHODS: In 68 individuals, carotid IMT was measured using high-resolution vascular ultrasound, while the presence of CAC was determined with electron beam tomography (EBT). Global and regional MBF was determined in milliliters per gram per minute with (13)N-ammonia and positron emission tomography (PET) at rest, during cold pressor testing (CPT), and during adenosine (ADO) stimulation. RESULTS: There was neither a relationship between carotid IMT and CAC (r = 0.10, p = 0.32) nor between carotid IMT and coronary circulatory function in response to CPT and during ADO (r = -0.18, p = 0.25 and r = 0.10, p = 0.54, respectively). In 33 individuals, EBT detected CAC with a mean Agatston-derived calcium score of 44 +/- 18. There was a significant difference in regional MBFs between territories with and without CAC at rest and during ADO-stimulated hyperemia (0.69 +/- 0.24 vs. 0.74 +/- 0.23 and 1.82 +/- 0.50 vs. 1.95 +/- 0.51 ml/g/min; p < or = 0.05, respectively) and also during CPT in DM but less pronounced (0.81 +/- 0.24 vs. 0.83 +/- 0.23 ml/g/min; p = ns). The increase in CAC was paralleled with a progressive regional decrease in resting as well as in CPT- and ADO-related MBFs (r = -0.36, p < or = 0.014; r = -0.46, p < or = 0.007; and r = -0.33, p < or = 0.041, respectively). CONCLUSIONS: The absence of any correlation between carotid IMT and coronary circulatory function in type 2 DM suggests different features and stages of early atherosclerosis in the peripheral and coronary circulation. PET-measured MBF heterogeneity at rest and during vasomotor stress may reflect downstream fluid dynamic effects of coronary artery disease (CAD)-related early structural alterations of the arterial wall.
Resumo:
Streptococcus gordonii alpha-phosphoglucomutase, which converts glucose 6-phosphate to glucose 1-phosphate, is encoded by pgm. The pgm transcript is monocistronic and is initiated from a sigma(A)-like promoter. Mutants with a gene disruption in pgm exhibited an altered cell wall muropeptide pattern and a lower teichoic acid content, and had reduced fitness both in vitro and in vivo. In vitro, the reduced fitness included reduced growth, reduced viability in the stationary phase and increased autolytic activity. In vivo, the pgm-deficient strain had a lower virulence in a rat model of experimental endocarditis.
Resumo:
Black-blood MR coronary vessel wall imaging may become a powerful tool for the quantitative and noninvasive assessment of atherosclerosis and positive arterial remodeling. Although dual-inversion recovery is currently the gold standard, optimal lumen-to-vessel wall contrast is sometimes difficult to obtain, and the time window available for imaging is limited due to competing requirements between blood signal nulling time and period of minimal myocardial motion. Further, atherosclerosis is a spatially heterogeneous disease, and imaging at multiple anatomic levels of the coronary circulation is mandatory. However, this requirement of enhanced volumetric coverage comes at the expense of scanning time. Phase-sensitive inversion recovery has shown to be very valuable for enhancing tissue-tissue contrast and for making inversion recovery imaging less sensitive to tissue signal nulling time. This work enables multislice black-blood coronary vessel wall imaging in a single breath hold by extending phase-sensitive inversion recovery to phase-sensitive dual-inversion recovery, by combining it with spiral imaging and yet relaxing constraints related to blood signal nulling time and period of minimal myocardial motion.
Resumo:
Plants naturally synthesize a variety of polymers that have been used by mankind as a source of useful biomaterials. For example, cellulose, the main constituent of plant cell wall and the most abundant polymer on earth, has been used for several thousand years as a source of fibers for various fabrics. Similarly, rubber extracted from the bark of the tree Hevea brasiliensis, has been a major source of elastomers until the development of similar synthetic polymers. In the last century, the usefulness of plant polymers as biomaterials has been expanded through the chemical modification of the natural polymers. For example, a number of plastics have been made by substituting the hydroxyl groups present on the glucose moiety of cellulose with larger groups, such as nitrate or acetate, giving rise to materials such as cellulose acetate, a clear plastic used in consumer products such as toothbrush handles and combs. Similarly, starch has been used in the manufacture of plastics by either using it in blends with synthetic polymers or as the main constituent in biodegradable plastics. The advent of transformation and expres- sion of foreign genes in plants has created the possibility of expanding the usefulness of plants to include the synthesis of a range of biomolecules. In view of the capacity of certain crops to produce a large quantity of organic raw material at low cost, such as oils and starch, it is of interest to explore the possibility of using transgenic plants as efficient vectors for the synthesis of biopolymers. Such plant based biopolymers could replace, in part, the synthetic plastics and elastomers produced from petroleum, offering the advantage of renewability and sustainability. Furthermore, being natural pro- ducts, biopolymers are usually biodegradable and can thus contribute to alleviate problems associated with the management of plastic waste. In this article, the emphasis will be on the use of transgenic plants for the synthesis of two novel classes of industrially useful polymers, namely protein based polymers made from natural or artificial genes, and polyhydroxyalkanoates, a family of bacterial poly- esters having the properties of biodegradable plastics and elastomers.
Resumo:
PURPOSE: Cardiovascular magnetic resonance (CMR) has become a robust and important diagnostic imaging modality in cardiovascular medicine. However,insufficient image quality may compromise its diagnostic accuracy. No standardized criteria are available to assess the quality of CMR studies. We aimed todescribe and validate standardized criteria to evaluate the quality of CMR studies including: a) cine steady-state free precession, b) delayed gadoliniumenhancement, and c) adenosine stress first-pass perfusion. These criteria will serve for the assessment of the image quality in the setting of the Euro-CMR registry.METHOD AND MATERIALS: First, a total of 45 quality criteria were defined (35 qualitative criteria with a score from 0-3, and 10 quantitative criteria). Thequalitative score ranged from 0 to 105. The lower the qualitative score, the better the quality. The quantitative criteria were based on the absolute signal intensity (delayed enhancement) and on the signal increase (perfusion) of the anterior/posterior left ventricular wall after gadolinium injection. These criteria were then applied in 30 patients scanned with a 1.5T system and in 15 patients scanned with a 3.0T system. The examinations were jointly interpreted by 3 CMR experts and 1 study nurse. In these 45 patients the correlation between the results of the quality assessment obtained by the different readers was calculated.RESULTS: On the 1.5T machine, the mean quality score was 3.5. The mean difference between each pair of observers was 0.2 (5.7%) with a mean standarddeviation of 1.4. On the 3.0T machine, the mean quality score was 4.4. The mean difference between each pair of onservers was 0.3 (6.4%) with a meanstandard deviation of 1.6. The quantitative quality assessments between observers were well correlated for the 1.5T machine: R was between 0.78 and 0.99 (pCONCLUSION: The described criteria for the assessment of CMR image quality are robust and have a low inter-observer variability, especially on 1.5T systems.CLINICAL RELEVANCE/APPLICATION: These criteria will allow the standardization of CMR examinations. They will help to improve the overall quality ofexaminations and the comparison between clinical studies.
Resumo:
Rapport de synthèse : Les tumeurs de la paroi thoracique sont des pathologies graves dont le traitement principal consiste en une résection chirurgicale. L'enjeu majeur de cette intervention ontologique est de réséquer la totalité de la tumeur, ce qui nécessite une planification préopératoire minutieuse. Classiquement, l'identification et la localisation de la tumeur se fait à l'aide de la tomodensitométrie (computed tomography, CT) ou de l'imagerie par résonnance magnétique (1RM). Actuellement, l'imagerie nucléaire fonctionnelle par tomographie par émission de positons (positron emission tomography, PET) qui peut être couplée au CT (PET/CT) est de plus en plus appliquée aux patients présentant une tumeur maligne. Son efficacité a fréquemment été démontrée. Le but de la présente étude est d'évaluer la valeur du PET dans la planification de la résection des tumeurs de la paroi thoracique. Une analyse rétrospective de dix-huit patients opérés entre 2004 et 2006 a été réalisée; Dans ce groupe de patient, la taille de la tumeur mesurée sur la pièce opératoire réséquée a été comparée à la taille de la tumeur mesurée sur le CT et le PET. Les résultats démontrent que le CT surestimait de manière consistante la taille réelle de la tumeur par rapport au PET (+64% par rapport à +1%, P<0.001). De plus, le PET s'est avéré particulièrement performant pour prédire la taille des tumeurs de plus de 5.5 cm de diamètre par rapport au CT (valeur prédictive positive 80% par rapport à 44% et spécificité 93% par apport à 64%, respectivement). Cette étude démontre que le PET permettrait de mesurer la taille des tumeurs de la paroi thoracique de manière plus précise que le CT. Cette nouvelle modalité diagnostique s'avèrerait donc utile pour planifier les résections chirurgicales de telles tumeurs. A notre connaissance, aucune publication ne décrit la valeur du PET dans ce domaine. Les performances accrues du PET permettraient une meilleure délimitation des tumeurs ce qui améliorerait la précision de la résection chirurgicale. En conclusion, cette étude préliminaire rétrospective démontre la faisabilité du PET pour les tumeurs de la paroi thoracique. Ces résultats devraient être confirmés par une étude prospective incluant un plus grand nombre de patients avec la perspective de juger l'impact clinique réel du PET sur la prise en charge thérapeutique des patients.
Resumo:
The nature and assembly of the chlamydial division septum is poorly defined due to the paucity of a detectable peptidoglycan (PG)-based cell wall, the inhibition of constriction by penicillin and the presence of coding sequences for cell wall precursor and remodelling enzymes in the reduced chlamydial (pan-)genome. Here we show that the chlamydial amidase (AmiA) is active and remodels PG in Escherichia coli. Moreover, forward genetics using an E. coli amidase mutant as entry point reveals that the chlamydial LysM-domain protein NlpD is active in an E. coli reporter strain for PG endopeptidase activity (ΔnlpI). Immunolocalization unveils NlpD as the first septal (cell-wall-binding) protein in Chlamydiae and we show that its septal sequestration depends on prior cell wall synthesis. Since AmiA assembles into peripheral clusters, trimming of a PG-like polymer or precursors occurs throughout the chlamydial envelope, while NlpD targets PG-like peptide crosslinks at the chlamydial septum during constriction.