95 resultados para Tunels (Tests)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the effect of intraocular straylight (IOS) induced by white opacity filters (WOF) on threshold measurements for stimuli employed in three perimeters: standard automated perimetry (SAP), pulsar perimetry (PP) and the Moorfields motion displacement test (MDT).¦METHODS: Four healthy young (24-28 years old) observers were tested six times with each perimeter, each time with one of five different WOFs and once without, inducing various levels of IOS (from 10% to 200%). An increase in IOS was measured with a straylight meter. The change in sensitivity from baseline was normalized, allowing comparison of standardized (z) scores (change divided by the SD of normative values) for each instrument.¦RESULTS: SAP and PP thresholds were significantly affected (P < 0.001) by moderate to large increases in IOS (50%-200%). The drop in motion displacement (MD) from baseline with WOF 5, was approximately 5 dB, in both SAP and PP which represents a clinically significant loss; in contrast the change in MD with MDT was on average 1 minute of arc, which is not likely to indicate a clinically significant loss.¦CONCLUSIONS: The Moorfields MDT is more robust to the effects of additional straylight in comparison with SAP or PP.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Up to 10% of the patients in whom suspected betalactam hypersensitivity (HS) has been excluded by skin and challenge tests report suspected allergic reactions during subsequent treatments with the same or very similar betalactams. It has been suggested that the reactions may result from a resensitization induced by the challenge performed at the time of the allergological work-up. However, most patients did not undergo a second allergological work-up, to determine if the reactions resulted from betalactam HS or not. OBJECTIVES: We aimed to determine if children diagnosed nonallergic to betalactams have tolerated subsequent treatments with the initially suspected and/or other betalactams, and, in case of a reaction, if the reaction resulted from betalactam HS. Methods: We sent a questionnaire concerning the clinical history of their children to the parents of 256 children previously diagnosed nonallergic to betalactams. A second allergological work-up was performed in the children reporting suspected allergic reactions during subsequent treatments with the same and/or other betalactams. Skin tests were performed with the soluble form of the suspected (or very similar) betalactams and other betalactams from the same and other classes. Skin test responses were assessed at 15-20 min (immediate), 6-8 h (semi-late) and 48-72 h (late). Oral challenge (OC) was performed in children with negative skin tests, either at the hospital (immediate and accelerated reactions), or at home (delayed reactions). RESULTS: A response was obtained from 141 children (55.3%). Forty-eight (34%) of those children had not been treated with the betalactams for whom a diagnosis of allergy had been ruled out previously. Seven (7.5%) of the 93 children who had been treated again reported suspected allergic reactions. Skin tests and OC were performed in six of those children, and gave negative results in five children. In one child previously diagnosed nonallergic to amoxicillin associated with clavulanic acid, we diagnosed a delayed HS to clavulanic acid and a serum sickness-like disease to cefaclor. Thus, the frequency of reactions resulting from betalactam HS in children with negative skin and challenge tests is very low, and does not exceed 2.1% (2/93) if we consider that the child which refused a second allergological work-up is really allergic to betalactams. CONCLUSION: Our results in a very large number of children show that reactions presumed to result from betalactam HS are rare in children in whom the diagnosis of betalactam allergy has been ruled out previously. Moreover, they suggest that, as shown for the initial reactions, most of the reactions during subsequent treatments are rather a consequence of the infectious diseases for whom betalactams have been prescribed than a result of betalactam HS. Finally, they suggest that the risk of resensitization by OC is very low, and do not support the notion that skin testing should be repeated in children diagnosed nonallergic to betalactams.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genetic polymorphisms have currently been described in more than 200 systems affecting pharmacological responses (cytochromes P450, conjugation enzymes, transporters, receptors, effectors of response, protection mechanisms, determinants of immunity). Pharmacogenetic testing, i.e. the profiling of individual patients for such variations, is about to become largely available. Recent progress in the pharmacogenetics of tamoxifen, oral anticoagulants and anti-HIV agents is reviewed to discuss critically their potential impact on prescription and contribution/limits for improving rational and safe use of pharmaceuticals. Prospective controlled trials are required to evaluate large-scale pharmacogenetic testing in therapeutics. Ethical, social and psychological issues deserve particular attention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Tuberculosis (TB) screening in prisons is recommended, but the appropriate methods remain controversial. Studies evaluating screening in remand prisons arc scarce. METHOD: Between 1997 and 2001, voluntary screening based on the tuberculin skin test (TST) was offered to all prisoners on entry into the largest remand prison in Switzerland. Prisoners with positive results underwent chest X-rays. We analysed this information collected in an anonymous database. RESULTS: A total of 4890 prisoners entered the prison and were eligible for screening; 3779 (77.3%) had TST performed on average 9 days after arrival: 46.9% were positive (induration >= 10 mm). Positive TST rates were similar over the 5 years. Women were more likely to have a negative TST (60.4%) than men (47.7%; P < 0.001, Pearson's chi(2) 16.5). Positive TSTs varied according to the prisoner's country of origin (64% for sub-Saharan Africa, 57% for Eastern Europe, 56% for North Africa, 51% for Asia and 34% for North and West Europe). CONCLUSION: The percentage of TST-positive subjects was high, and most did not receive preventive treatment for latent TB. The usefulness of systematic TST for all prisoners on entry is limited, as diagnosis of TB disease usually remains the priority in prisons. Keywords

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plutonium and (90)Sr are considered to be among the most radiotoxic nuclides produced by the nuclear fission process. In spite of numerous studies on mammals and humans there is still no general agreement on the retention half time of both radionuclides in the skeleton in the general population. Here we determined plutonium and (90)Sr in human vertebrae in individuals deceased between 1960 and 2004 in Switzerland. Plutonium was measured by sensitive SF-ICP-MS techniques and (90)Sr by radiometric methods. We compared our results to the ones obtained for other environmental compartments to reveal the retention half time of NBT fallout (239)Pu and (90)Sr in trabecular bones of the Swiss population. Results show that plutonium has a retention half time of 40+/-14 years. In contrast (90)Sr has a shorter retention half time of 13.5+/-1.0 years. Moreover (90)Sr retention half time in vertebrae is shown to be linked to the retention half time in food and other environmental compartments. These findings demonstrate that the renewal of the vertebrae through calcium homeostatic control is faster for (90)Sr excretion than for plutonium excretion. The precise determination of the retention half time of plutonium in the skeleton will improve the biokinetic model of plutonium metabolism in humans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fish acute toxicity tests play an important role in environmental risk assessment and hazard classification because they allow for first estimates of the relative toxicity of various chemicals in various species. However, such tests need to be carefully interpreted. Here we shortly summarize the main issues which are linked to the genetics and the condition of the test animals, the standardized test situations, the uncertainty about whether a given test species can be seen as representative to a given fish fauna, the often missing knowledge about possible interaction effects, especially with micropathogens, and statistical problems like small sample sizes and, in some cases, pseudoreplication. We suggest that multi-factorial embryo tests on ecologically relevant species solve many of these issues, and we shortly explain how such tests could be done to avoid the weaker points of fish acute toxicity tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction : Depuis 2005, le « Test FIFA » est utilisé chez les arbitres de football, comme critère de sélection pour monter dans les échelons de l'arbitrage et chaque arbitre base son entraînement dans cet objectif. Ce test a été développé grâce aux nombreux travaux scientifiques, ayant utilisé l'analyse vidéo, afin de quantifier les activités de match des arbitres et analyser leur performance en cours de match. Objectifs : Le but de ce travail a été d'évaluer la performance de l'arbitre, lors d'un match de football, au moyen d'un accéléromètre en raison de sa facilité d'utilisation et en particulier d'évaluer si au cours du match, il existe une éventuelle diminution de la capacité de performance engendrée par la fatigue. Enfin, à la lumière des résultats, nous avons pu discuter du bien fondé du «test par intervalle proposé par la FIFA» comme moyen d'estimation de la capacité physique d'un arbitre. Méthode : Il s'agit d'une étude prospective basée sur une analyse descriptive. Les données ont été récoltées dans des stades de football suisses ≥1ère Ligue, du 01.12.2011 au 01.12.2012. Le groupe étudié était composé de 5 arbitres de football de sexe masculin, dont deux officiant en 1ère Ligue et faisant partie des talents de l'Association Cantonale Vaudoise de Football (ACVF) et trois en Super League et Challenge League. Les 5 arbitres ont été équipés d'un iPhone 3GS®, muni d'une application, capable d'enregistrer les déplacements sur le terrain (arrêt, marche et course). Le traitement des données a été effectué par un programme Matlab®, élaboré par le Laboratoire des Mesures d'Analyse du Mouvement (LMAM) de l'EPFL, tout comme l'application en question. Pour ce travail ont été considérées les phases et les fréquences d'arrêt, de marche et de course tout au long de l'évolution de la partie. Résultats : Durant les 90 minutes du match, la répartition se fait de la manière suivante : 13,74% du temps total où l'accéléromètre ne mesure aucune activité, 33,70% concernent une activité de course alors que le reste, 52,48% est de la marche. Avec l'avancement dans le match, il est constaté une augmentation des phases d'arrêt et une diminution du temps de course. Une intensité d'effort plus importante est observée lors des 15 premières minutes du match (environ  41,7% de course), alors qu'en fin de la partie, il y a une alternance de marche et de course avec des efforts de plus en plus brefs. La détermination de la médiane de durée des différents efforts a montré qu'un épisode de marche ou de course étaient de 5-6 secondes. De plus, les épisodes de marche ou de course étaient rarement >20 secondes. Discussion : Les résultats montrent que l'accéléromètre est un système de mesure facile d'utilisation, permettant un gain de temps dans l'analyse des données pour évaluer la performance sportive. Les principaux résultats de cette étude, ont mis en évidence une diminution de l'intensité des activités physiques de l'arbitre avec l'avancement du match, résultant soit de sa propre fatigue, soit de celle des joueurs dictant le rythme du jeu. Cette diminution se traduit par des déplacements de plus en plus brefs au fil du temps. La mesure de médiane du temps de course et de marche (5-6 sec) correspond à une activité aérobie pour la marche et anaérobie alactique pour la course. Par conséquent, le « test par intervalle » de la FIFA actuel ne nous semble pas adéquat en raison de sa filière énergétique de type anaérobique lactique. Conclusion : Cette étude pilote apporte un nouveau type d'instrumentation efficace et simple, jamais employé auparavant dans l'analyse des activités de match des arbitres de football. Il permet d'explorer des mouvements avec précision au fil du match et apporte un nouvel aspect sur la quantification de performance des arbitres non exploré jusqu'ici. Après analyse de l'ensemble des paramètres, il semble que le test FIFA ne soit pas adapté à la performance exigée par l'arbitrage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the trend in molecular epidemiology towards both genome-wide association studies and complex modelling, the need for large sample sizes to detect small effects and to allow for the estimation of many parameters within a model continues to increase. Unfortunately, most methods of association analysis have been restricted to either a family-based or a case-control design, resulting in the lack of synthesis of data from multiple studies. Transmission disequilibrium-type methods for detecting linkage disequilibrium from family data were developed as an effective way of preventing the detection of association due to population stratification. Because these methods condition on parental genotype, however, they have precluded the joint analysis of family and case-control data, although methods for case-control data may not protect against population stratification and do not allow for familial correlations. We present here an extension of a family-based association analysis method for continuous traits that will simultaneously test for, and if necessary control for, population stratification. We further extend this method to analyse binary traits (and therefore family and case-control data together) and accurately to estimate genetic effects in the population, even when using an ascertained family sample. Finally, we present the power of this binary extension for both family-only and joint family and case-control data, and demonstrate the accuracy of the association parameter and variance components in an ascertained family sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cyst-based ecotoxicological tests are simple and low-cost methods for assessing acute toxicity. Nevertheless, only a few comparative studies on their sensitivity are known. In the present study, the suitability of the use of two freshwater Anostracan species, Streptocephalus rubricaudatus and S. texanus, was assessed. The impact of 16 priority pollutants (4 heavy metals, 11 organic, and 1 organometallic compounds) on these two species, as well as on Artemia salina (Artoxkit M), Daphnia magna (International Organization for Standardization 6341), and S. proboscideus (Streptoxkit F) was assessed. For indicative comparison, bioassays using Brachionus calyciflorus (Rotoxkit F) and Photobacterium phosphoreum (Microtox) were also performed. For heavy metals (K2Cr2O7, Cd2+, Zn2+, Cu2+), the sensitivity of the two studied Streptocephalus species was slightly higher than that of D. magna. It was significantly more elevated than for the marine A. salina. For organic and organometallic micropollutants [phenol, 3,5-dichlorophenol, pentachlorophenol (PCP), hydroquinone, linear alkylbenzene sulfonate, sodium dodecyl sulfate, tributylphosphate, dimethylphthalate, atrazine, lindane, malathion, tributyltin chloride (TBT-Cl)], the sensitivity of the 4 anostracan species was of the same order of magnitude as that of D. magna. Artemia salina was slightly less sensitive to some organic compounds (PCP, hydroquinone, TBT-Cl). The sensitivity of S. rubricaudatus to organic solvents was low. On the other hand, this anostracan was quite sensitive to NaCl. Thus, its use is restricted to freshwater samples. The evaluation of global practicability of these two tests confirms that cyst-based freshwater anostracans may be used to perform low-cost tests at a sensitivity comparable to that of D. magna (24 h immobilization test).