142 resultados para Tridimensional echocardiography


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Pulmonary arteriovenous malformations (PAVMs) due to hereditaryhemorrhagic telangiectases (HHT) is associated with paradoxical strokes, brainabcesses, and increased prevalence of migraines. We report a patient in whom wefound a relationship between PAMVs and a reduction in frequency of migrainewith aura after the treatment of the first pulmonary malformation.Patient and methods: A 67-year-old woman developed migraine with visual auraand major epistaxis during childhood. A PAVM is discovered and surgically removedin 1969. Migraines nearly disappeared during several years, after which theystarted to reappear progressively. A HHT syndrome is diagnosed based on recurrentepistaxis, the development of cutaneous telangiectases and a positive family history.She suffered a left subcortical stroke in 2008. Perfusion CT, chest radiography,thoracic CT-angiography, contrast echocardiography, contrast transcranial Dopplerand cerebral MRI were performed.Results: Perfusion CT showed previous asymptomatic strokes in cerebellum andbasal ganglia. 4 PAMVs were confirmed on the chest x-ray whose structural conformationis identified on thoracic CT. Contrast echocardiography and transcranialDoppler showed a massive right to left shunt. It is planned to embolize the 4PAVMs, and migraine frequency will now be prospectively assessed.Conclusion: This patient with a pulmonary arteriovenous malformation showeda reduced migraine frequency after resection of her lung lesion. This suggests acausal relationship between a right to left shunt and migraine, as discussed inpatients with patent foramen ovale.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rupture of a congenital aneurysm of the sinus of Valsalva is a rare congenital cardiac malformation. This case report describes a congenital aneurysm of the sinus of Valsalva which ruptured into the right ventricle in a 3-year-old girl. The exact route of the fistula through the cardiac walls and the localization of the rupture into the right ventricle was not completely defined by two-dimensional and color Doppler echocardiography and could be determined only by magnetic resonance imaging (MRI).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Previous studies reported on the association of left ventricular mass index (LVMI) with urinary sodium or with circulating or urinary aldosterone. We investigated the independent associations of LVMI with the urinary excretion of both sodium and aldosterone. We randomly recruited 317 untreated subjects from a white population (45.1% women; mean age 48.2 years). Measurements included echocardiographic left ventricular (LV) properties, the 24-hour urinary excretion of sodium and aldosterone, plasma renin activity (PRA), and proximal (RNa(prox)) and distal (RNa(dist)) renal sodium reabsorption, assessed from the endogenous lithium clearance. In multivariable-adjusted models, we expressed changes in LVMI per 1-SD increase in the explanatory variables, while accounting for sex, age, systolic blood pressure, and the waist-to-hip ratio. LVMI increased independently with the urinary excretion of both sodium (+2.48 g/m(2); P=0.005) and aldosterone (+2.63 g/m(2); P=0.004). Higher sodium excretion was associated with increased mean wall thickness (MWT: +0.126 mm, P=0.054), but with no change in LV end-diastolic diameter (LVID: +0.12 mm, P=0.64). In contrast, higher aldosterone excretion was associated with higher LVID (+0.54 mm; P=0.017), but with no change in MWT (+0.070 mm; P=0.28). Higher RNa(dist) was associated with lower relative wall thickness (-0.81x10(-2), P=0.017), because of opposite trends in LVID (+0.33 mm; P=0.13) and MWT (-0.130 mm; P=0.040). LVMI was not associated with PRA or RNa(prox.) In conclusion, LVMI independently increased with both urinary sodium and aldosterone excretion. Increased MWT explained the association of LVMI with urinary sodium and increased LVID the association of LVMI with urinary aldosterone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To date, myxoma on a mechanical valve annulus has not been reported. The case is reported of a 74-year-old woman who was admitted to hospital following the identification of an intracardiac tumor mass. Six years previously, the patient had received a mechanical valve implanted in the mitral position. Transesophageal echocardiography revealed a mobile hypoechogenic tumorous mass attached to the anterior annulus of the prosthesis. The tumor was successfully treated by surgical excision, and a diagnosis of myxoma was confirmed both clinically and pathologically.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Current applications of cardiac magnetic resonance (CMR) imaging offer a wide spectrum of indications in the setting of acute cardiac care. In particular, CMR is helpful for the differential diagnosis of chest pain by detection of myocarditis and pericarditis. Also, takotsubo cardiomyopathy and acute aortic diseases can be evaluated by CMR and are important differential diagnoses in patients with acute chest pain. In patients with restricted windows for echocardiography, CMR is the method of choice to evaluate complications of acute myocardial infarction (AMI). In AMI, CMR allows for a unique characterization of myocardial damage by quantifying necrosis, microvascular obstruction, oedema (=area at risk), and haemorrhage. These capabilities will help us to understand better the pathophysiological events during infarction and will also allow to assess new treatment strategies in AMI. To what extent the information on tissue damage will guide patient management is not yet clear and further research in this field is warranted. In the near future, CMR will certainly become more routine in acute cardiac care units, as manufacturers are now focusing strongly on this aspect of user-friendliness. Finally, in the next decade or so, MRI of other nuclei such as fluorine and carbon might become a clinical reality, which would allow for metabolic and targeted molecular imaging with excellent sensitivity and specificity

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The Contegra® is a conduit made from the bovine jugular vein and then interposed between the right ventricle and the pulmonary artery. It is used for cardiac malformations in the reconstruction of right ventricular outflow tract. OBJECTIVE: To describe both normal and pathological appearances of the Contegra® in radiological imaging, to describe imaging of complications and to define the role of CT and MRI in postoperative follow-up. MATERIALS AND METHODS: Forty-three examinations of 24 patients (17 boys and 7 girls; mean age: 10.8 years old) with Contegra® conduits were reviewed. Anatomical description and measurements of the conduits were performed. Pathological items examined included stenosis, dilatation, plicature or twist, thrombus or vegetations, calcifications and valvular regurgitation. Findings were correlated to the echographic gradient through the conduit when available. RESULTS: CT and MR work-up showed Contegra® stenosis (n = 12), dilatation (n = 9) and plicature or twist (n = 7). CT displayed thrombus or vegetations in the Contegra® in three clinically infected patients. Calcifications of the conduit were present at CT in 12 patients and valvular regurgitation in three patients. The comparison between CT and/or MR results showed a good correlation between the echographic gradient and the presence of stenosis in the Contegra®. CONCLUSION: CT and MR bring additional information about permeability and postoperative anatomy especially when echocardiography is inconclusive. Both techniques depict the normal appearance of the conduit, and allow comparison and precise evaluation of changes in the postoperative follow-up.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Cardiopulmonary bypass (CPB) with aortic cross-clamping and cardioplegic arrest remains the method of choice for patients requiring standard myocardial revascularization. Therefore, very high-risk patients presenting with acute coronary syndrome, unstable angina, onset of cardiac decompensation and requiring emergency multiple myocardial revascularization, can have a poor outcome. The on-pump beating heart technique can reduce the mortality and the morbidity in such a selected group of patients and this report describes our clinical experience. METHODS: Out of 290 patients operated for CABG from January 2005 to January 2006, 25 (8.6%) selected high-risk patients suffering from life threatening coronary syndrome (mean age 69 +/- 7 years) and requiring emergency multiple myocardial revascularization, underwent on-pump beating heart surgery. The mean pre-operative left ventricle ejection fraction (LVEF) was 27 +/- 8%. The majority of them (88%) suffered of tri-vessel coronary disease and 6 (24%) had a left main stump disease. Nine patients (35%) were on severe cardiac failure and seven among them (28%) received a pre-operative intra-aortic balloon pump. The pre-operative EuroScore rate was equal or above 8 in 18 patients (73%). RESULTS: All patients underwent on-pump-beating heart coronary revascularization. The mean number of graft/patient was 2.9 +/- 0.6 and the internal mammary artery was used in 23 patients (92%). The mean CPB time was 84 +/- 19 minutes. Two patients died during the recovery stay in the intensive care unit, and there were no postoperative myocardial infarctions between the survivors. Eight patients suffered of transitorily renal failure and 1 patient developed a sternal wound infection. The mean hospital stay was 12 +/- 7 days. The follow-up was complete for all 23 patients survived at surgery and the mean follow-up time was 14 +/- 5 months. One patient died during the follow-up for cardiac arrest and 2 patients required an implantable cardiac defibrillator. One year after surgery they all had a standard trans-thoracic echocardiogram showing a mean LVEF rate of 36 +/- 11.8%. CONCLUSION: Standard on-pump arrested heart coronary surgery has higher mortality and morbidity in emergencies. The on-pump beating heart myocardial revascularization seems to be a valid alternative for the restricted and selected cohort of patients suffering from life threatening coronary syndrome and requiring multiple emergency CABG.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mitral regurgitation (MR) involves systolic retrograde flow from the left ventricle into the left atrium. While trivial MR is frequent in healthy subjects, moderate to severe MR constitutes the second most prevalent valve disease after aortic valve stenosis. Major causes of severe MR in Western countries include degenerative valve disease (myxomatous disease, flail leaflet, annular calcification) and ischaemic heart disease, while rheumatic disease remains a major cause of MR in developing countries. Chronic MR typically progresses insidiously over many years. Once established, however, severe MR portends a poor prognosis. The severity of MR can be assessed by various techniques, Doppler echocardiography being the most widely used. Mitral valve surgery is the only treatment of proven efficacy. It alleviates clinical symptoms and prevents ventricular dilatation and heart failure (or, at least, it attenuates further progression of these abnormalities). Valve repair significantly improves clinical outcomes compared with valve replacement, reducing mortality by approximately 70%. Reverse LV remodelling after valve repair occurs in half of patients with functional MR. Percutaneous, catheter-based to mitral valve repair is a novel approach currently under clinical scrutiny, with encouraging preliminary results. This modality may provide a valuable alternative to mitral valve surgery, especially in critically ill patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transapical aortic valve replacement through an apical aneurysm is traditionally contraindicated because of the risk of severe systemic embolization when thrombi are present. However, a chronic fibrotic aneurysm without apical thrombi carries a low risk of distal embolization and can be safely employed for a transapical transcatheter aortic valve replacement in case of absence of an alternative access site (severe vascular disease, small vascular sizes and diseased calcified aorta). We illustrate our experience with a 73-year-old patient suffering from symptomatic aortic valve stenosis, coronary artery disease with occluded left anterior descending artery, left ventricular apical aneurysm and severe peripheral vascular disease, who successfully underwent a transapical 26 mm Sapien? XT stent-valve implantation through the fibrotic thin akinetic apical wall.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report a case of a fifty year old woman with Graves' disease with positive AntiTPO antibodies and positive AntiTSH receptor antibodies, who was hospitalized with a right cardiac failure. A pulmonary hypertension was discovered on echocardiography. After adequate antithyroid therapy, the right cardiac failure regressed rapidly and pulmonary pressure normalised. An autoimmune process has often been proposed to explain the association between pulmonary hypertension and hyperthyroidism. We report the arguments supporting this autoimmune etiopathogenesis. We also discuss an other hypothesis based on a direct effect of thyroid hormones on the pulmonary circulation and the effects of high cardiac output associated with hyperthyroidism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Percutaneous closure of patent foramen ovale (PFO) has been proposed as the treatment of choice for young high-risk patients who suffered cryptogenic stroke and/or peripheral paradoxical embolism. We sought to compare prospectively two different devices used for percutaneous PFO closure.Prospective data were collected on 40 high risk patients (females: 38%, mean age : 44 +/- 11 years, interatrial septal aneurysm >10 mm: 68%) who underwent percutaneous PFO closure after cryptogenic stroke (n = 38) or peripheral paradoxical embolism (n = 2). Chronologically, 20 patients were first treated by a PFO-Star (Cardia, Burnsville, MI) device. Then, 20 other patients received a Starflex occluder (NMT, Boston, MA). The primary endpoint was complete PFO closure at 6 months as assessed by transthoracic contrast echocardiography. Secondary endpoints were major peri- or post procedural complications and clinical recurrence at 1 year follow-up.Baseline clinical and anatomical characteristics were comparable for both groups. Complete PFO closure was observed in 50% (PFO-Star) and 90% (Starflex) of patients (p=0.001) respectively. Major peri-procedural complications occurred in the PFO-star group only: right-sided device thrombus (1 patient) and aorto-right atrial fistula (1 patient). At 1 year follow-up, no clinical recurrence occurred.In conclusion, despite the absence of clinical recurrence in this high-risk population with presumed paradoxical embolism, complete PFO closure at 6 months follow-up was significantly related to the type of closure device used

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this experimental study is to evaluate the feasibility and the outcome of total endovascular stent implantation in the aortic arch. Indications for this operation-technique would be acute or chronic dissection of the aortic arch (non-A-non-B dissection) or type B dissection with retrograde extension. Four pigs were canulated via the distal abdominal aorta and a retrograde placement of a Djumbodis arch stent (4-9 cm) was controlled by using intravascular ultrasound and intracardiac ultrasound by the inferior cava vein and under radioscopic control. Cerebral perfusion, by using a flow meter placed on one prepared carotid artery, were controlled before, immediate post-procedural (<1 min), and in the early follow-up after aortic arch stent implantation. During the implantation process, especially during balloon inflation and deflation, mean carotid perfusion decreases slightly. A reactive increase of carotid perfusion after stent placements indicates transitory cerebral hypo-perfusion. Non-covered aortic arch stent implantation is technically feasible and could be a potential treatment option in otherwise inoperable arch dissections. The time required for balloon inflation and deflation causes an important risk of cerebral ischemia. The latter can be reduced by transaxillary perfusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: A right-to-left shunt can be identified by contrast transcranial Doppler ultrasonography (c-TCD) at rest and/or after a Valsalva maneuver (VM) or by arterial blood gas (ABG) measurement. We assessed the influence of controlled strain pressures and durations during VM on the right-to-left passage of microbubbles, on which depends the shunt classification by c-TCD, and correlated it with the right-to-left shunt evaluation by ABG measurements in stroke patients with patent foramen ovale (PFO). METHODS: We evaluated 40 stroke patients with transesophageal echocardiography-documented PFO. The microbubbles were recorded with TCD at rest and after 4 different VM conditions with controlled duration and target strain pressures (duration in seconds and pressure in cm H2O, respectively): V5-20, V10-20, V5-40, and V10-40. The ABG analysis was performed after pure oxygen breathing in 34 patients, and the shunt was calculated as percentage of cardiac output. RESULTS: Among all VM conditions, V5-40 and V10-40 yielded the greatest median number of microbubbles (84 and 95, respectively; P&lt;0.01). A significantly larger number of microbubbles were detected in V5-40 than in V5-20 (P&lt;0.001) and in V10-40 than in V10-20 (P&lt;0.01). ABG was not sensitive enough to detect a shunt in 31 patients. CONCLUSIONS: The increase of VM expiratory pressure magnifies the number of microbubbles irrespective of the strain duration. Because the right-to-left shunt classification in PFO is based on the number of microbubbles, a controlled VM pressure is advised for a reproducible shunt assessment. The ABG measurement is not sensitive enough for shunt assessment in stroke patients with PFO.