249 resultados para Tomography, spiral computed


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Transaxial tomoscintigraphy (or single-photon emission computerised tomography) was used to detect secondary deposits of carcinoma in 17 patients who had been injected with iodine-131-labelled monoclonal antibodies against carcinoembryonic antigen. Of 17 tumor sites studied by tomoscintigraphy 16 were detected (sensitivity 94%); five sites had a volume smaller than 10 cm3. Tomoscintigraphy also detected three unknown tumour deposits later confirmed by surgery or radiology. In contrast, when 21 tumour sites in the same patients were studied by rectilinear scintigraphy, only nine tumour sites were detected (sensitivity 43%), of which eight had a volume larger than 50 cm3.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: Extensive multilobar cortical dysplasia in infants commonly is first seen with catastrophic epilepsy and poses a therapeutic challenge with respect to control of epilepsy, brain development, and psychosocial outcome. Experience with surgical treatment of these lesions is limited, often not very encouraging, and holds a higher operative risk when compared with that in older children and adults. METHODS: Two infants were evaluated for surgical control of catastrophic epilepsy present since birth, along with a significant psychomotor developmental delay. Magnetic resonance imaging showed multilobar cortical dysplasia (temporoparietooccipital) with a good electroclinical correlation. They were treated with a temporal lobectomy and posterior (parietooccipital) disconnection. RESULTS: Both infants had excellent postoperative recovery and at follow-up (1.5 and 3.5 years) evaluation had total control of seizures with a definite "catch up" in their development, both motor and cognitive. No long-term complications have been detected to date. CONCLUSIONS: The incorporation of disconnective techniques in the surgery for extensive multilobar cortical dysplasia in infants has made it possible to achieve excellent seizure results by maximizing the extent of surgical treatment to include the entire epileptogenic zone. These techniques decrease perioperative morbidity, and we believe would decrease the potential for the development of long-term complications associated with large brain excisions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim: Pleural effusion is common in cancer patients and to determine its malignant origin is of huge clinical significance. PET/CT with 18F-FDG is of diagnostic value in staging and follow-up, but its ability to differentiate between malignant and benign effusions is not precisely known. Patients, methods: We examined 50 PET/CT from 47 patients (29 men, 18 women, 60±16 years) with pleural effusion and known cancer (24 NSCLC, 7 lymphomas, 5 breasts, 4 GIST, 3 mesotheliomas, 2 head and neck, 2 malignant teratoma, 1 colorectal, 1 oesophageal, 1 melanoma) for FDG uptake in the effusions using SUVmax. This was correlated to cytopathology performed after a median of 21 days (interquartile range -3 to 23), which included pH, relative distribution (macrophages, neutrophils, eosinophils, basophils, lymphocytes, plasmocytes), and absolute cell count. Results: Malignant cells were found in 17 effusions (34%) (6 NSCLC, 5 lymphomas, 2 breasts, 2 mesotheliomas, 2 malignant teratomas). SUV in malignant effusions were higher than in benign ones [3.7 (95%CI 1.8-5.6) vs. 1.7 g/ml (1.5-1.9), p = 0.001], with a correlation between malignant effusion and SUV (Spearman coefficient r = 0.50, p = 0.001), but not with other cytopathological or radiological parameters (ROC area 0.83±0.06). Using a 2.2-mg/l SUV threshold, 12 PET/CT studies were positive and 38 negative with sensitivity, specificity, positive and negative predictive values of 53%, 91%, 75% and 79%, respectively. For NSCLC only (n = 24), ROC area was 0.95±0.04, 7 studies were positive and 17 negative with a sensitivity, specificity, positive and negative predictive values of 83%, 89%, 71 and 94%, respectively. Conclusion: PET/CT may help to differentiate the malignant or benign origin of a pleural effusion with a high specificity in patients with known cancer, in particular NSCLC.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND/AIMS: The present report examines a new pig model for progressive induction of high-grade stenosis, for the study of chronic myocardial ischemia and the dynamics of collateral vessel growth. METHODS: Thirty-nine Landrace pigs were instrumented with a novel experimental stent (GVD stent) in the left anterior descending coronary artery. Eight animals underwent transthoracic echocardiography at rest and under low-dose dobutamine. Seven animals were examined by nuclear PET and SPECT analysis. Epi-, mid- and endocardial fibrosis and the numbers of arterial vessels were examined by histology. RESULTS: Functional analysis showed a significant decrease in global left ventricular ejection fraction (24.5 +/- 1.6%) 3 weeks after implantation. There was a trend to increased left ventricular ejection fraction after low-dose dobutamine stress (36.0 +/- 6.6%) and a significant improvement of the impaired regional anterior wall motion. PET and SPECT imaging documented chronic hibernation. Myocardial fibrosis increased significantly in the ischemic area with a gradient from epi- to endocardial. The number of arterial vessels in the ischemic area increased and coronary angiography showed abundant collateral vessels of Rentrop class 1. CONCLUSION: The presented experimental model mimics the clinical situation of chronic myocardial ischemia secondary to 1-vessel coronary disease.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Immunoscintigraphy (IS) consists of in vivo body structure imaging using a specific labelled antibody to an antigen concentrated in the structure under study. Technically, the image contrast is better when IS is performed with a computerized emission tomography system. High concentrations of carcinoembryonic antigen (CEA) have been reported in medullary thyroid carcinoma and thyroglobulin (Tg) is a marker for differentiated thyroid carcinoma. We used injections of 131-I labelled monoclonal antibodies to CEA and Tg to detect thyroid tumours. A feasibility trial using anti-CEA antibodies gave very encouraging results. However, only tumours larger than 10 cm3 could be detected. Contradictory results were obtained using anti-Tg antibodies but this data must be considered as preliminary. Various means of improving the method and the concept of accessibility of the antigen to the antibody in vivo are discussed. This study shows IS to be a promising experimental technique. Further studies are required to define its clinical indications before it can be advocated for routine use.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: Effective cancer treatment generally requires combination therapy. The combination of external beam therapy (XRT) with radiopharmaceutical therapy (RPT) requires accurate three-dimensional dose calculations to avoid toxicity and evaluate efficacy. We have developed and tested a treatment planning method, using the patient-specific three-dimensional dosimetry package 3D-RD, for sequentially combined RPT/XRT therapy designed to limit toxicity to organs at risk. METHODS AND MATERIALS: The biologic effective dose (BED) was used to translate voxelized RPT absorbed dose (D(RPT)) values into a normalized total dose (or equivalent 2-Gy-fraction XRT absorbed dose), NTD(RPT) map. The BED was calculated numerically using an algorithmic approach, which enabled a more accurate calculation of BED and NTD(RPT). A treatment plan from the combined Samarium-153 and external beam was designed that would deliver a tumoricidal dose while delivering no more than 50 Gy of NTD(sum) to the spinal cord of a patient with a paraspinal tumor. RESULTS: The average voxel NTD(RPT) to tumor from RPT was 22.6 Gy (range, 1-85 Gy); the maximum spinal cord voxel NTD(RPT) from RPT was 6.8 Gy. The combined therapy NTD(sum) to tumor was 71.5 Gy (range, 40-135 Gy) for a maximum voxel spinal cord NTD(sum) equal to the maximum tolerated dose of 50 Gy. CONCLUSIONS: A method that enables real-time treatment planning of combined RPT-XRT has been developed. By implementing a more generalized conversion between the dose values from the two modalities and an activity-based treatment of partial volume effects, the reliability of combination therapy treatment planning has been expanded.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We describe the case of a man with a history of complex partial seizures and severe language, cognitive and behavioural regression during early childhood (3.5 years), who underwent epilepsy surgery at the age of 25 years. His early epilepsy had clinical and electroencephalogram features of the syndromes of epilepsy with continuous spike waves during sleep and acquired epileptic aphasia (Landau-Kleffner syndrome), which we considered initially to be of idiopathic origin. Seizures recurred at 19 years and presurgical investigations at 25 years showed a lateral frontal epileptic focus with spread to Broca's area and the frontal orbital regions. Histopathology revealed a focal cortical dysplasia, not visible on magnetic resonance imaging. The prolonged but reversible early regression and the residual neuropsychological disorders during adulthood were probably the result of an active left frontal epilepsy, which interfered with language and behaviour during development. Our findings raise the question of the role of focal cortical dysplasia as an aetiology in the syndromes of epilepsy with continuous spike waves during sleep and acquired epileptic aphasia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The implementation of new techniques of imaging in the daily practice of the radiation oncologist is a major advance in these last 10 years. This allows optimizing the therapeutic intervals and locoregional control of the disease while limiting side effects. Among them, positron emission tomography (PET) offers an opportunity to the clinician to obtain data relative to the tumoral biological mechanisms, while benefiting from the morphological images of the computed tomography (CT) scan. Recently hybrid PET/CT has been developed and numerous studies aimed at optimizing its use in the planning, the evaluation of the treatment response and the prognostic value. The choice of the radiotracer (according to the type of cancer and to the studied biological mechanism) and the various methods of tumoral delineation, require a regular update to optimize the practices. We propose throughout this article, an exhaustive review of the published researches (and in process of publication) until December 2011, as user guide of PET/CT in all the aspects of the modern radiotherapy (from the diagnosis to the follow-up): biopsy guiding, optimization of treatment planning and dosimetry, evaluation of tumor response and prognostic value, follow-up and early detection of recurrence versus tumoral necrosis. In a didactic purpose, each of these aspects is approached by primary tumoral location, and illustrated with representative iconographic examples. The current contribution of PET/CT and its perspectives of development are described to offer to the radiation oncologist a clear and up to date reading in this expanding domain.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Following 15 years of experimental studies, tumor immunotargeting using monoclonal antibodies directed against tumor associated antigens shows now important monoclonal antibodies directed against tumor associated antigens shows now important clinical developments. This is mainly due to encouraging therapeutic results which have obtained using humanized antibodies such as the anti-CD20 rituximab in follicular B lymphomas and the anti-DrbB2 herceptin in breast carcinomas. Thanks to genetic engineering it is possible to graft variable or hypervariable regions from murine antibodies to human IgG, and even to obtain fully human antibodies by using either transgenic mice containing a large part of the human repertoire of human IgG, or selection of human antibody fragments expressed by phages. Radiolabeling of antibodies played a major role to demonstrate the tumor immunotargeting specificity and remains attractive for the diagnosis by immunoscintigraphy as well as for the treatment by radioimmunotherapy of some cancers. In this review, the current results and the prospects of diagnostic and therapeutic uses of anti-tumor antibodies and their fragments will be described. Concerning diagnosis, 123-iodine or 99m-technetium labeled Fab fragments allowed very demonstrative tumor images but this technique has a limited effect upon the therapeutic attitude. Immuno-PET (positron emission tomography) could enhance the sensitivity of this imaging method. Radio-immunoguided surgery and immunophotodetection are attractive techniques still under evaluation. Concerning therapy, 131-iodine labeled anti-CD20 antibodies gave spectacular results in non-Hodgkin's B lymphomas. In solid tumors which as less radiosensitive, radioimmunotherapy could concern small tumors and need the use of two-steps targeting and/or alpha emitters radioisotopes. Some other strategies will be described such as bispecific antibodies directed against tumors and immune effector cells, some antibody fragments expressed on T cells called T-bodies or some biological studies using intrabodies. Published data and works in progress demonstrate that immunotargeting of tumors will have a growing place in the treatments of cancer patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Personal results are presented to illustrate the development of immunoscintigraphy for the detection of cancer over the last 12 years, from the early experimental results in nude mice grafted with human colon carcinoma to the most modern form of immunoscintigraphy applied to patients, using I123 labeled Fab fragments from monoclonal anti-CEA antibodies detected by single photon emission computerized tomography (SPECT). The first generation of immunoscintigraphy used I131 labeled, immunoadsorbent purified, polyclonal anti-CEA antibodies and planar scintigraphy, as the detection system. The second generation used I131 labeled monoclonal anti-CEA antibodies and SPECT, while the third generation employed I123 labeled fragments of monoclonal antibodies and SPECT. The improvement in the precision of tumor images with the most recent forms of immunoscintigraphy is obvious. However, we think the usefulness of immunoscintigraphy for routine cancer management has not yet been entirely demonstrated. Further prospective trials are still necessary to determine the precise clinical role of immunoscintigraphy. A case report is presented on a patient with two liver metastases from a sigmoid carcinoma, who received through the hepatic artery a therapeutic dose (100 mCi) of I131 coupled to 40 mg of a mixture of two high affinity anti-CEA monoclonal antibodies. Excellent localisation in the metastases of the I131 labeled antibodies was demonstrated by SPECT and the treatment was well tolerated. The irradiation dose to the tumor, however, was too low at 4300 rads (with 1075 rads to the normal liver and 88 rads to the bone marrow), and no evidence of tumor regression was obtained. Different approaches for increasing the irradiation dose delivered to the tumor by the antibodies are considered.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Transarterial radioembolization consist in delivering small particles loaded with Yttrium90, a pure beta emitter, in order to treat primary and secondary liver tumors. This treatment needs precaution since inadequate delivery of these beads can lead to severe complications. Moreover, a precise radiation dosing is crucial to achieve a good clinical success and to avoid complications such as radioembolization-induced liver disease. This review describes all the precautions and highlights clinical and technical considerations that need to be taken to avoid complications.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The aim of this work is to compare two methods used for determining the proper shielding of computed tomography (CT) rooms while considering recent technological advances in CT scanners. The approaches of the German Institute for Standardisation and the US National Council on Radiation Protection and Measurements were compared and a series of radiation measurements were performed in several CT rooms at the Lausanne University Hospital. The following three-step procedure is proposed for assuring sufficient shielding of rooms hosting new CT units with spiral mode acquisition and various X-ray beam collimation widths: (1) calculate the ambient equivalent dose for a representative average weekly dose length product at the position where shielding is required; (2) from the maximum permissible weekly dose at the location of interest, calculate the transmission factor F that must be taken to ensure proper shielding and (3) convert the transmission factor into a thickness of lead shielding. A similar approach could be adopted to use when designing shielding for fluoroscopy rooms, where the basic quantity would be the dose area product instead of the load of current (milliampere-minute).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Postmortem angiography methods that use water soluble or lipid soluble liquid contrast compounds may potentially modify the composition of fluid-based biological samples and thus influence toxicological findings. In this study, we investigated whether toxicological investigations performed in urine collected prior to and post angiography using Angiofil? mixed with paraffin oil are characterized by different qualitative or quantitative results. In addition, we studied whether diluting samples with 1% and 3% contrast medium solution may modify molecule concentration. A postmortem angiography group consisting of 50 cases and a postmortem group without angiography consisting of 50 cases were formed. In the first group, toxicological investigations were performed in urine samples collected prior to and post angiography as well as in undiluted and diluted samples. In the second group, analyses were performed in undiluted and diluted urine, bile, gastric content, cerebrospinal and pericardial fluids collected during autopsy. The preliminary results indicate that differences may be observed between urine samples collected prior to and post angiography in the number of identified molecules in relation to specific cases. Analyses performed in diluted samples failed to reveal differences that might potentially alter the interpretation of toxicological results in all analyzed specimens for nearly all molecules, except for tetrahydrocannabinol and its metabolites. Though these findings suggest that toxicology might be effectively performed, in very special cases and for a large number of molecules, in biological samples collected after angiography, it remains recommendable to collect biological fluids for toxicology prior to contrast medium injection.