40 resultados para Thread safe parallel run-time


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Aqueous flow through trabeculectomy blebs has been suggested to influence filtration bleb survival. We investigated the relationship between the requirement to increase aqueous flow via adjustable suture removal and surgical outcomes following "safe trabeculectomy" with mitomycin C (MMC). Methods: 62 consecutive eyes of 53 patients underwent fornix based trabeculectomy with adjustable sutures, intraoperative MMC and intensive postoperative steroids. Subconjunctival antimetabolite injections and bleb needlings were administered according to bleb vascularity and IOP trends. Main outcome measures were: success rates (definition: IOP≤21mmHg and 20% IOP reduction); number of antimetabolite injections; bleb needlings; number of of eyes recommencing glaucoma medications and complications. Results: Mean age was 70.4±16.0 years (mean± SD); mean preoperative IOP was 24.5±9.1 mmHg and decreased to 12.3±8.9mmHg postoperatively. Mean number of sutures was 2.6 ± 0.7. Eyes were divided into 2 groups in relation to the number of sutures removed. The number of subconjunctival MMC injections required for those requiring 2 suture removals was significantly greater than those requiring 1 suture removal (p<0.05) The number of needlings and 5FU injections also increased but did not reach significance (p=0.09 and p=0.34 respectively). Least-squared linear regression analysis showed the number of needlings required had a statistically significant (p=0.05) trend with respect to time elapsed between surgery and first suture removal. No other interventions had significant trends. Mean time between surgery and suture removal was: 4.2±9.2 weeks (suture #1) and 5.7±9.7 weeks (suture#2). Antiglaucoma medication was restarted in only 5 eyes. Postoperative complications were infrequent: Seidel (3.2%), peripheral choroidal effusions at any time (3.2%), and shallow anterior chamber (1.6%). Conclusion: Eyes requiring a greater number of suture removals required a significantly greater number of antifibrosis interventions. The time elapsed before suture removal was inversely related to the number of postoperative needlings, suggesting these eyes may have decreased aqueous production and therefore require aggressive post-operative management to prevent bleb failure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Acute mountain sickness is a frequent and debilitating complication of high-altitude exposure, but there is little information on the prevalence and time course of acute mountain sickness in children and adolescents after rapid ascent by mechanical transportation to 3500 m, an altitude at which major tourist destinations are located throughout the world. METHODS: We performed serial assessments of acute mountain sickness (Lake Louise scores) in 48 healthy nonacclimatized children and adolescents (mean +/- SD age: 13.7 +/- 0.3 years; 20 girls and 28 boys), with no previous high-altitude experience, 6, 18, and 42 hours after arrival at the Jungfraujoch high-altitude research station (3450 m), which was reached through a 2.5-hour train ascent. RESULTS: We found that the overall prevalence of acute mountain sickness during the first 3 days at high altitude was 37.5%. Rates were similar for the 2 genders and decreased progressively during the stay (25% at 6 hours, 21% at 18 hours, and 8% at 42 hours). None of the subjects needed to be evacuated to lower altitude. Five subjects needed symptomatic treatment and responded well. CONCLUSION: After rapid ascent to high altitude, the prevalence of acute mountain sickness in children and adolescents was relatively low; the clinical manifestations were benign and resolved rapidly. These findings suggest that, for the majority of healthy nonacclimatized children and adolescents, travel to 3500 m is safe and pharmacologic prophylaxis for acute mountain sickness is not needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Waddlia chondrophila is a strict intracellular microorganism belonging to the order Chlamydiales that has been isolated twice from aborted bovine fetuses, once in USA and once in Germany. This bacterium is now considered as an abortigenic agent in cattle. However, no information is available regarding the presence of this bacterium in Africa. Given the low sensitivity of cell culture to recover such an obligate intracellular bacterium, molecular-based diagnostic approaches are warranted. This report describes the development of a quantitative SYBR Green real-time PCR assay targeting the recA gene of W. chondrophila. Analytical sensitivity was 10 copies of control plasmid DNA per reaction. No cross-amplification was observed when testing pathogens that can cause abortion in cattle. The PCR exhibited a good intra-run and inter-run reproducibility. This real-time PCR was then applied to 150 vaginal swabs taken from Tunisian cows that have aborted. Twelve samples revealed to be Waddlia positive, suggesting a possible role of this bacterium in this setting. This new real-time PCR assay represents a diagnostic tool that may be used to further study the prevalence of Waddlia infection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Research into the biomechanical manifestation of fatigue during exhaustive runs is increasingly popular but additional understanding of the adaptation of the spring-mass behaviour during the course of strenuous, self-paced exercises continues to be a challenge in order to develop optimized training and injury prevention programs. This study investigated continuous changes in running mechanics and spring-mass behaviour during a 5-km run. 12 competitive triathletes performed a 5-km running time trial (mean performance: ̴17 min 30 s) on a 200 m indoor track. Vertical and anterior-posterior ground reaction forces were measured every 200 m by a 5-m long force platform system, and used to determine spring-mass model characteristics. After a fast start, running velocity progressively decreased (- 11.6%; P<0.001) in the middle part of the race before an end spurt in the final 400-600 m. Stride length (- 7.4%; P<0.001) and frequency (- 4.1%; P=0.001) decreased over the 25 laps, while contact time (+ 8.9%; P<0.001) and total stride duration (+ 4.1%; P<0.001) progressively lengthened. Peak vertical forces (- 2.0%; P<0.01) and leg compression (- 4.3%; P<0.05), but not centre of mass vertical displacement (+ 3.2%; P>0.05), decreased with time. As a result, vertical stiffness decreased (- 6.0%; P<0.001) during the run, whereas leg stiffness changes were not significant (+ 1.3%; P>0.05). Spring-mass behaviour progressively changes during a 5-km time trial towards deteriorated vertical stiffness, which alters impact and force production characteristics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Time-resolved measurements of tissue autofluorescence (AF) excited at 405 nm were carried out with an optical-fiber-based spectrometer in the bronchi of 11 patients. The objectives consisted of assessing the lifetime as a new tumor/normal (T/N) tissue contrast parameter and trying to explain the origin of the contrasts observed when using AF-based cancer detection imaging systems. No significant change in the AF lifetimes was found. AF bronchoscopy performed in parallel with an imaging device revealed both intensity and spectral contrasts. Our results suggest that the spectral contrast might be due to an enhanced blood concentration just below the epithelial layers of the lesion. The intensity contrast probably results from the thickening of the epithelium in the lesions. The absence of T/N lifetime contrast indicates that the quenching is not at the origin of the fluorescence intensity and spectral contrasts. These lifetimes (6.9 ns, 2.0 ns, and 0.2 ns) were consistent for all the examined sites. The fact that these lifetimes are the same for different emission domains ranging between 430 and 680 nm indicates that there is probably only one dominant fluorophore involved. The measured lifetimes suggest that this fluorophore is elastin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: In alpine skiing, chronometry analysis is currently the most common tool to assess performance. It is widely used to rank competitors during races, as well as to manage athletes training and to evaluate material. Usually, this measurement is accurately realized using timing cells. Nevertheless, these devices are too complex and expensive to allow chronometry of every gates crossing. On the other side, differential GPS can be used for measuring gate crossing time (Waegli et al). However, this is complex (e.g. recording gate position with GPS) and mainly used in research applications. The aim of the study was to propose a wearable system to time gates crossing during alpine skiing slalom (SL), which is suitable for routine uses. METHODS: The proposed system was composed of a 3D accelerometer (ADXL320®, Analog Device, USA) placed at the sacrum of the athlete, a matrix of force sensors (Flexiforce®, Tekscan, USA) fixed on the right shin guard and a data logger (Physilog®, BioAGM, Switzerland). The sensors were sampled at 500 Hz. The crossing time were calculated in two phases. First, the accelerometer was used to detect the curves by considering the maximum of the mediolateral peak acceleration. Then, the force sensors were used to detect the impacts with the gates by considering maximum force variation. In case of non impact, the detection was realized based on the acceleration and features measured at the other gates. In order to assess the efficiency of the system, two different SL were monitored twice for two world cup level skiers, a male SL expert and a female downhill expert. RESULTS AND DISCUSSION: The combination of the accelerometer and force sensors allowed to clearly identify the gate crossing times. When comparing the runs of the SL expert and the downhill expert, we noticed that the SL expert was faster. For example for the first SL, the overall difference between the best run of each athlete was of 5.47s. At each gate, the SL expert increased the time difference slower at the beginning (0.27s/gate) than at the end (0.34s/gate). Furthermore, when comparing the runs of the SL expert, a maximum time difference of 20ms at each gate was noticed. This showed high repeatability skills of the SL expert. In opposite, the downhill expert with a maximum difference time of 1s at each gate was clearly less repeatable. Both skiers were not disturbed by the system. CONCLUSION: This study proposed a new wearable system to automatically time gates crossing during alpine skiing slalom combining force and accelerometer sensors. The system was evaluated with two professional world cup skiers and showed a high potential. This system could be extended to time other parameters. REFERENCES Waegli A, Skaloud J (2007). Inside GNSS, Spring, 24-34.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nanotechnology is becoming part of our daily life in a wide range of products such as computers, bicycles, sunscreens or nanomedicines. While these applications already become reality, considerable work awaits scientists, engineers, and policy makers, who want such nanotechnological products to yield a maximum of benefit at a minimum of social, environmental, economic and (occupational) health cost. Considerable efforts for coordination and collaboration in research are needed if one wants to reach these goals in a reasonable time frame and an affordable price tag. This is recognized in Europe by the European Commission which funds not only research projects but also supports the coordination of research efforts. One of these coordination efforts is NanoImpactNet, a researcher-operated network, which started in 2008 promote scientific cross-talk across all disciplines on the health and environmental impact of nanomaterials. Stakeholders contribute to these activities, notably the definition of research and knowledge needs. Initial discussions in this domain focused on finding an agreement on common metrics, and which elements are needed for standardized approaches for hazard and exposure identification. There are many nanomaterial properties that may play a role. Hence, to gain the time needed to study this complex matter full of uncertainties, researchers and stakeholders unanimously called for simple, easy and fast risk assessment tools that can support decision making in this rapidly moving and growing domain. Today, several projects are starting or already running that will develop such assessment tools. At the same time, other projects investigate in depth which factors and material properties can lead to unwanted toxicity or exposure, what mechanisms are involved and how such responses can be predicted and modelled. A vision for the future is that once these factors, properties and mechanisms are understood, they can and will be accounted for in the development of new products and production processes following the idea of "Safety by Design". The promise of all these efforts is a future with nanomaterials where most of their risks are recognized and addressed before they even reach the market.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effects of footwear and inclination on running biomechanics over short intervals are well documented. Although recognized that exercise duration can impact running biomechanics, it remains unclear how biomechanics change over time when running in minimalist shoes and on slopes. Our aims were to describe these biomechanical changes during a 50-minute run and compare them to those observed in standard shoes. Thirteen trained recreational male runners ran 50 minutes at 65% of their maximal aerobic velocity on a treadmill, once in minimalist shoes and once in standard shoes, 1 week apart in a random order. The 50-minute trial was divided into 5-minute segments of running at 0%, +5%, and -5% of treadmill incline sequentially. Data were collected using photocells, high-speed video cameras, and plantar-pressure insoles. At 0% incline, runners exhibited reduced leg stiffness and plantar flexion angles at foot strike and lower plantar pressure at the forefoot and toes in minimalist shoes from minute 34 of the protocol onward. However, only reduced plantar pressure at the toes was observed in standard shoes. Overall, similar biomechanical changes with increased exercise time were observed on the uphill and downhill inclines. The results might be due to the unfamiliarity of subjects to running in minimalist shoes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Hyperglycemia is a metabolic alteration in major burn patients associated with complications. The study aimed at evaluating the safety of general ICU glucose control protocols applied in major burns receiving prolonged ICU treatment. METHODS: 15year retrospective analysis of consecutive, adult burn patients admitted to a single specialized centre. EXCLUSION CRITERIA: death or length of stay <10 days, age <16years. VARIABLES: demographic variables, burned surface (TBSA), severity scores, infections, ICU stay, outcome. Metabolic variables: total energy, carbohydrate and insulin delivery/24h, arterial blood glucose and CRP values. Analysis of 4 periods: 1, before protocol; 2, tight doctor driven; 3, tight nurse driven; 4, moderate nurse driven. RESULTS: 229 patients, aged 45±20 years (mean±SD), burned 32±20% TBSA were analyzed. SAPSII was 35±13. TBSA, Ryan and ABSI remained stable. Inhalation injury increased. A total of 28,690 blood glucose samples were analyzed: the median value remained unchanged with a narrower distribution over time. After the protocol initiation, the normoglycemic values increased from 34.7% to 65.9%, with a reduction of hypoglycaemic events (no extreme hypoglycemia in period 4). Severe hyperglycemia persisted throughout with a decrease in period 4 (9.25% in period 4). Energy and glucose deliveries decreased in periods 3 and 4 (p<0.0001). Infectious complications increased during the last 2 periods (p=0.01). CONCLUSION: A standardized ICU glucose control protocol improved the glycemic control in adult burn patients, reducing glucose variability. Moderate glycemic control in burns was safe specifically related to hypoglycemia, reducing the incidence of hypoglycaemic events compared to the period before. Hyperglycemia persisted at a lower level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cardiovascular disease is the leading cause of death worldwide. Within this subset, coronary artery disease (CAD) is the most prevalent. Magnetic resonance angiography (MRA) is an emerging technique that provides a safe, non-invasive way of assessing CAD progression. To generate contrast between tissues, MR images are weighted according to the magnetic properties of those tissues. In cardiac MRI, T2 contrast, which is governed by the rate of transverse signal loss, is often created through the use of a T2-Preparation module. T2-Preparation, or T2-Prep, is a magnetization preparation scheme used to improve blood/myocardium contrast in cardiac MRI. T2-Prep methods generally use a non-selective +90°, 180°, 180°, -90° train of radiofrequency (RF) pulses (or variant thereof), to tip magnetization into the transverse plane, allow it to evolve, and then to restore it to the longitudinal plane. A key feature in this process is the combination of a +90° and -90° RF pulse. By changing either one of these, a mismatch occurs between signal excitation and restoration. This feature can be exploited to provide additional spectral or spatial selectivity. In this work, both of these possibilities are explored. The first - spectral selectivity - has been examined as a method of improving fat saturation in coronary MRA. The second - spatial selectivity - has been examined as a means of reducing imaging time by decreasing the field of view, and as a method of reducing artefacts originating from the tissues surrounding the heart. Two additional applications, parallel imaging and self-navigation, are also presented. This thesis is thus composed of four sections. The first, "A Fat Signal Suppression for Coronary MRA at 3T using a Water-Selective Adiabatic T2-Preparation Technique", was originally published in the journal Magnetic Resonance in Medicine (MRM) with co-authors Ruud B. van Heeswijk and Matthias Stuber. The second, "Combined T2-Preparation and 2D Pencil Beam Inner Volume Selection", again with co-authors Ruud van Heeswijk and Matthias Stuber, was also published in the journal MRM. The third, "A cylindrical, inner volume selecting 2D-T2-Prep improves GRAPPA-accelerated image quality in MRA of the right coronary artery", written with co-authors Jerome Yerly and Matthias Stuber, has been submitted to the "Journal of Cardiovascular Magnetic Resonance", and the fourth, "Combined respiratory self-navigation and 'pencil-beam' 2D-T2 -Prep for free-breathing, whole-heart coronary MRA", with co¬authors Jerome Chaptinel, Giulia Ginami, Gabriele Bonanno, Simone Coppo, Ruud van Heeswijk, Davide Piccini, and Matthias Stuber, is undergoing internal review prior to submission to the journal MRM. -- Les maladies cardiovasculaires sont la cause principale de décès dans le monde : parmi celles-ci, les maladies coronariennes sont les plus répandues. L'angiographie par résonance magnétique (ARM) est une technique émergente qui fournit une manière sûre, non invasive d'évaluer la progression de la coronaropathie. Pour obtenir un contraste entre les tissus, les images d'IRM sont pondérées en fonction des propriétés magnétiques de ces tissus. En IRM cardiaque, le contraste en T2, qui est lié à la décroissance du signal transversal, est souvent créé grâce à l'utilisàtion d'un module de préparation T2. La préparation T2, ou T2-Prep, est un système de préparation de l'aimantation qui est utilisé pour améliorer le contraste entre le sang et le myocarde lors d'une IRM cardiaque. Les méthodes de T2-Prep utilisent généralement une série non-sélective d'impulsions de radiofréquence (RF), typiquement [+ 90°, 180°, 180°, -90°] ou une variante, qui bascule l'aimantation dans le plan transversal, lui permet d'évoluer, puis la restaure dans le plan longitudinal. Un élément clé de ce processus est la combinaison des impulsions RF de +90° et -90°. En changeant l'une ou l'autre des impulsions, un décalage se produit entre l'excitation du signal et de la restauration. Cette fonction peut être exploitée pour fournir une sélectivité spectrale ou spatiale. Dans cette thèse, les deux possibilités sont explorées. La première - la sélectivité spectrale - a été examinée comme une méthode d'améliorer la saturation de la graisse dans l'IRM coronarienne. La deuxième - la sélectivité spatiale - a été étudiée comme un moyen de réduire le temps d'imagerie en diminuant le champ de vue, et comme une méthode de réduction des artefacts provenant des tissus entourant le coeur. Deux applications supplémentaires, l'imagerie parallèle et la self-navigation, sont également présentées. Cette thèse est ainsi composée de quatre sections. La première, "A Fat Signal Suppression for Coronary MRA at 3T using a Water-Selective Adiabatic T2-Preparation Technique", a été publiée dans la revue médicale Magnetic Resonance .in Medicine (MRM) avec les co-auteurs Ruud B. van Heeswijk et Matthias Stuber. La deuxième, Combined T2-Preparation and 2D Pencil Beam Inner Volume Selection", encore une fois avec les co-auteurs Ruud van Heeswijk et Matthias Stuber, a également été publiée dans le journal MRM. La troisième, "A cylindrical, inner volume selecting 2D-T2-Prep improves GRAPPA- accelerated image quality in MRA of the right coronary artery", écrite avec les co-auteurs Jérôme Yerly et Matthias Stuber, a été présentée au "Journal of Cardiovascular Magnetic Resonance", et la quatrième, "Combined respiratory self-navigation and 'pencil-beam' 2D-T2 -Prep for free-breathing, whole-heart coronary MRA", avec les co-auteurs Jérôme Chaptinel, Giulia Ginami, Gabriele Bonanno , Simone Coppo, Ruud van Heeswijk, Davide Piccini, et Matthias Stuber, subit un examen interne avant la soumission à la revue MRM.