44 resultados para Teeth extraction
Resumo:
Plasma catecholamines provide a reliable biomarker of sympathetic activity. The low circulating concentrations of catecholamines and analytical interferences require tedious sample preparation and long chromatographic runs to ensure their accurate quantification by HPLC with electrochemical detection. Published or commercially available methods relying on solid phase extraction technology lack sensitivity or require derivatization of catecholamine by hazardous reagents prior to tandem mass spectrometry (MS) analysis. Here, we manufactured a novel 96-well microplate device specifically designed to extract plasma catecholamines prior to their quantification by a new and highly sensitive ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. Processing time, which included sample purification on activated aluminum oxide and elution, is less than 1 h per 96-well microplate. The UPLC-MS/MS analysis run time is 2.0 min per sample. This UPLC-MS/MS method does not require a derivatization step, reduces the turnaround time by 10-fold compared to conventional methods used for routine application, and allows catecholamine quantification in reduced plasma sample volumes (50-250 μL, e.g., from children and mice).
Resumo:
Aim Avoiding 'mini-laparotomy' to extract a colectomy specimen may decrease wound complications and further improve recovery after laparoscopic surgery. The aim of this study was to develop a new technique for transrectal specimen extraction (TRSE) and to compare it with conventional laparoscopy (CL) for left sided colectomy. Method Eleven patients with benign disease requiring either sigmoid or left colon resection underwent TRSE. The unfired circular stapler was inserted transanally and used as a guide to suture-close the recto-sigmoid junction laparoscopically and as a handle to pull the sutured sigmoid through the opened rectum inside a laparoscopic camera bag. The anvil was inserted into the lumen of the intussuscepted sigmoid and pushed to the level of the anastomosis. The anastomosis was fashioned end-to-end in the first patients and side-to-end in the following patients to improve safety. Intra-operative and postoperative outcomes of patients undergoing TRSE were compared with those of a group of 20 patients undergoing CL, who were matched for type of resection, body mass index and age. Results The procedure was successful in all but the first patient who was converted to conventional laparoscopic colectomy without any additional morbidity. Two patients in the end-to-end anastomosis group, but none in the side-to-end group, developed peri-anastomotic sepsis. Compared with CL, patients undergoing TRSE did not show any significant differences in operative time, recovery or morbidity. Conclusion Transrectal specimen extraction after left colectomy using the circular stapler technique is feasible. A side-to-end anastomosis appears safer than an end-to-end anastomosis. Further studies are needed to explore the potential advantages of this procedure over CL.
Resumo:
A rapid biological method for the determination of the bioavailability of naphthalene was developed and its value as an alternative to extraction-based chemical approaches demonstrated. Genetically engineered whole-cell biosensors are used to determine bioavailable naphthalene and their responses compared with results from Tenax extraction and chemical analysis. Results show a 1:1 correlation between biosensor results and chemical analyses for naphthalene-contaminated model materials and sediments, but the biosensor assay is much faster. This work demonstrates that biosensor technology can perform as well as standard chemical methods, though with some advantages including the inherent biological relevance of the response, rapid response time, and potential for field deployment. A survey of results from this work and the literature shows that bioavailability under non-equilibrium conditions nonetheless correlates well with K(oc) or K(d). A rationale is provided wherein chemical resistance is speculated to be operative.
Resumo:
The small Rho-family GTPase Cdc42 is critical for cell polarization and polarizes spontaneously in absence of upstream spatial cues. Spontaneous polarization is thought to require dynamic Cdc42 recycling through Guanine nucleotide Dissociation Inhibitor (GDI)-mediated membrane extraction and vesicle trafficking. Here, we describe a functional fluorescent Cdc42 allele in fission yeast, which demonstrates Cdc42 dynamics and polarization independent of these pathways. Furthermore, an engineered Cdc42 allele targeted to the membrane independently of these recycling pathways by an amphipathic helix is viable and polarizes spontaneously to multiple sites in fission and budding yeasts. We show that Cdc42 is highly mobile at the membrane and accumulates at sites of activity, where it displays slower mobility. By contrast, a near-immobile transmembrane domain-containing Cdc42 allele supports viability and polarized activity, but does not accumulate at sites of activity. We propose that Cdc42 activation, enhanced by positive feedback, leads to its local accumulation by capture of fast-diffusing inactive molecules.
Resumo:
Background: To evaluate the safety of immediate sequential bilateral cataract extraction (ISBCE) with respect to indications, visual outcomes, complications, benefits and disadvantages. Methods: This is a retrospective review of all ISBCEs performed at Kantonsspital Winterthur, Switzerland, between April 2000 and September 2013. The case notes of 500 eyes of 250 patients were reviewed. Of these 500 eyes, 472 (94.4%) had a straight forward phacoemulsification with posterior chamber intraocular lens implantation; 21 (4.2%) had a planned extracapsular cataract extraction; 4 (0.8%) had an intracapsular cataract extraction and 3 (0.6%) had a combined phacoemulsification with trabeculectomy. Results: Over 66% of eyes achieved improved visual acuity (at least 3 Snellen lines) following ISBCE. Median preoperative best corrected visual acuity (BCVA) was 0.5 LogMAR; the interquartile range was [0.4, 1] LogMAR. At one week control the median BCVA was 0.3 LogMAR, IQR [0.1, 0.5] LogMAR. At one month the median BCVA was 0.15 LogMAR, IQR [0.05, 0.3] (p < 0.01). There were no sight-threatening intraoperative or postoperative complications observed. Conclusions: ISBCE is an effective and safe option with high degree of patient satisfaction. The relative benefits of ISBCE should be balanced against the theoretically enhanced risks.
Resumo:
In forensic investigation of firearm-related cases, determination of the residual amount of volatile compounds remaining inside a cartridge could be useful in estimating the time since its discharge. Published approaches are based on following the decrease of selected target compounds as a function of time by using solid phase micro-extraction (SPME). Naphthalene, as well as an unidentified decomposition product of nitrocellulose (referred to as "TEA2"), are usually employed for this purpose. However, reliability can be brought into question given their high volatility and the low reproducibility of their extracted quantities. In order to identify alternatives and therefore develop improved dating methods, an extensive study on the composition and variability of volatile residues in nine different types of cartridges was carried out. Analysis was performed using headspace sorptive extraction (HSSE), which is a more exhaustive technique compared to SPME. 166 compounds were identified (several of which for the first time), and it was observed that the final compositional characteristics of each residue were strongly dependent on its source. Variability of single identified compounds within and between different types of cartridge, as well as their evolution over time, was also studied. Many explosion products containing up to 4 aromatic rings were found to be globally present in high proportions amongst residues. 27 of them (excluding naphthalene) also presented detectable decreases during the first 24 h. Therefore, they could be used as complementary target analytes in future dating methods.
Resumo:
In fetal brain MRI, most of the high-resolution reconstruction algorithms rely on brain segmentation as a preprocessing step. Manual brain segmentation is however highly time-consuming and therefore not a realistic solution. In this work, we assess on a large dataset the performance of Multiple Atlas Fusion (MAF) strategies to automatically address this problem. Firstly, we show that MAF significantly increase the accuracy of brain segmentation as regards single-atlas strategy. Secondly, we show that MAF compares favorably with the most recent approach (Dice above 0.90). Finally, we show that MAF could in turn provide an enhancement in terms of reconstruction quality.
Resumo:
AIMS: There is no standard test to determine the fatigue resistance of denture teeth. With the increasing number of patients with implant-retained dentures the mechanical strength of the denture teeth requires more attention and valid laboratory test set-ups. The purpose of the present study was to determine the fatigue resistance of various denture teeth using a dynamic load testing machine. METHODS: Four denture teeth were used: Bonartic II (Candulor), Physiodens (Vita), SR Phonares II (Ivoclar Vivadent) and Trubyte (Dentsply). For dynamic load testing, first upper molars with a similar shape and cusp inclination were selected. The molar teeth were embedded in cylindrical steel molds with denture base material (ProBase, Ivoclar Vivadent). Dynamic fatigue loading was carried out on the mesio-buccal cusp at a 45° angle using dynamic testing machines and 2,000,000 cycles at 2Hz in water (37°C). Three specimens per group and load were submitted to decreasing load levels (at least 4) until all the three specimens no longer showed any failures. All the specimens were evaluated under a stereo microscope (20× magnification). The number of cycles reached before observing a failure, and its dependence on the load and on the material, has been modeled using a parametric survival regression model with a lognormal distribution. This allowed to estimate the fatigue resistance for a given material as the maximal load for which one would observe less than 1% failure after 2,000,000 cycles. RESULTS: The failure pattern was similar for all denture teeth, showing a large chipping of the loaded mesio-buccal cusp. In our regression model, there were statistically significant differences among the different materials, with SR Phonares II and Bonartic II showing a higher resistance than Physiodens and Trubyte, the fatigue resistance being estimated at around 110N for the former two, and at about 60N for the latter two materials. CONCLUSION: The fatigue resistance may be a useful parameter to assess and to compare the clinical risk of chipping and fracture of denture tooth materials.