47 resultados para SILICA COMPOSITE MEMBRANES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rationale: The purpose of this article is to demonstrate the use of homologous culture cells in treating an advanced coccon formation of the hand and three extended squamous cell carcinomas of the lower and upper limb in a patient with recessive dystrophic epidermolysis bullosa. The preparation and application of these cells in the operation room are being described. Methods: A number of surgical approaches have been described to correct these deformities in order to improve function.We propose a new therapeutic approach of treating loss of motion and independent digital function as well as coverage of large skin defects in a patient with recessive dystrophic epidermolysis bullosa by using autologous culture cells. Surgical treatment of these patients is really difficult because of the existing skin fragility. Furthermore, surgical wounds do not easily heal because of recurrent blisters and erosions as well as due to the patients' poor nutricial status. Results: We report our experience of mutiple extended cutaneous squamous cell carcinomas arising in our patient which were successfully managed using autologous composite cultured skin grafts. The cocoon hand deformity was also treated with the limb becoming functional. Conclusion: The use of autologous keratinocytes and fibroblasts in epidermolysis bullosa is hereby outlined for the fist time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a combined shape and mechanical anisotropy evolution model for a two-phase inclusion-bearing rock subject to large deformation. A single elliptical inclusion embedded in a homogeneous but anisotropic matrix is used to represent a simplified shape evolution enforced on all inclusions. The mechanical anisotropy develops due to the alignment of elongated inclusions. The effective anisotropy is quantified using the differential effective medium (DEM) approach. The model can be run for any deformation path and an arbitrary viscosity ratio between the inclusion and host phase. We focus on the case of simple shear and weak inclusions. The shape evolution of the representative inclusion is largely insensitive to the anisotropy development and to parameter variations in the studied range. An initial hardening stage is observed up to a shear strain of gamma = 1 irrespective of the inclusion fraction. The hardening is followed by a softening stage related to the developing anisotropy and its progressive rotation toward the shear direction. The traction needed to maintain a constant shear rate exhibits a fivefold drop at gamma = 5 in the limiting case of an inviscid inclusion. Numerical simulations show that our analytical model provides a good approximation to the actual evolution of a two-phase inclusion-host composite. However, the inclusions develop complex sigmoidal shapes resulting in the formation of an S-C fabric. We attribute the observed drop in the effective normal viscosity to this structural development. We study the localization potential in a rock column bearing varying fraction of inclusions. In the inviscid inclusion case, a strain jump from gamma = 3 to gamma = 100 is observed for a change of the inclusion fraction from 20% to 33%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Huqf Supergroup in Oman contains an exceptionally well-preserved and complete sedimentary record of the Middle to Late Neoproterozoic Era. Outcrops of the Huqf Supergroup in northern and central Oman are now well documented, but their correlation with a key succession in the Mirbat area of southern Oman, containing a sedimentary record of two Neoproterozoic glaciations, is poorly understood. Integration of lithostratigraphic, chemostratigraphic and new U-Pb detrital zircon data suggests that the Mirbat Group is best placed within the Cryogenian (c. 850-635 Ma) part of the Huqf Supergroup. The c. I km thick marine deposits of the Arkahawl and Marsham Formations of the Mirbat Group are thought to represent a stratigraphic interval between older Cryogenian and younger Cryogenian glaciations that is not preserved elsewhere in Oman. The bulk of detrital zircons in the Huqf Supergroup originate from Neoproterozoic parent rocks. However, older Mesoproterozoic, Palaeoproterozoic and even Archaean zircons can be recognized in the detrital population from the upper Mahara Group (Fiq Formation) and Nafun Group, suggesting the tapping of exotic sources, probably from the Arabian-Nubian Shield.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME Les membranes néovasculaires (MNV) compliquent diverses pathologies ophtalmiques. Elles sont à l'origine d'une importante baisse de l'acuité visuelle lorsque elles se situent à proximité de la fovéa. A l'heure actuelle, peu de données relatives à leur association aux pathologies inflammatoires de l'oeil (uvéites) existent. Dans ce travail, la fréquence de MNV a été évaluée parmi 643 patients avec uvéite. Leur impact sur l'acuité visuelle ainsi que le pronostic en fonction des différents traitements effectués ont été étudiés. Les dossiers des 643 patients souffrant d'uvéite ont été étudiés. Les patients présentant une MNV ont été classés en trois groupes en fonction de l'importance de l'inflammation intraoculaire: élevée (2+ cellules dans le vitré), moyenne (1/2+ à 1+ cellules dans le vitré) ou absente (0 cellules dans le vitré). L'évolution de l'acuité visuelle fut considérée comme favorable (+VA: maintient de l'acuité visuelle ou gain d'une ou plusieurs lignes de Snellen) ou défavorable (-VA: perte d'une ou plusieurs lignes Snellen). Chez 9 patients, le traitement instauré a consisté, initialement, en l'administration orale de corticostéroïdes (CST) à haute dose qui, dans le cas d'évolution favorable (-FVA ou régression angiographique de la MNV), était arrêtée en doses dégressives. Dans les évolutions défavorables (-VA ou progression angiographique de la MNV), les CST étaient maintenus à dose moyenne en complémentation d'un traitement par thérapie laser (photothérapie dynamique (PDT), thermothérapie transpupillaire (TTT) ou laser Argon). Ce protocole thérapeutique ne fut appliqué chez trois patients en raison de la non disponibilité de PDT ou d'un diagnostic manqué d'uvéite. Douze patients sur 643 avec uvéite ont présenté une MNV. L'impact visuel moyen était de 4.5 lignes de Snellen et le temps moyen de suivi était de 19.5 mois. Deux patients avec inflammation intraoculaire élevée ont évolué favorablement sous CST seuls. Huit patients avec inflammation intraoculaire moyenne ont évolué favorablement sous CST seuls chez trois patients, alors que quatre patients ont nécessité une thérapie laser additionnelle. Le dernier patient ne fut traité que par thérapie laser sans CST (diagnostic manqué d'uvéite). Deux patients sans inflammation intraoculaire ont eu un pronostic défavorable sous CST seuls (pas d'autre alternative thérapeutique). Notre étude a démontré que les MNV sont une complication rare de l'uvéite qui, après traitement adéquat, ont un pronostic visuel relativement favorable. Bien que les CST semblent être la première modalité thérapeutique, les traitements laser devraient être adoptés tôt dans les situations d'inflammation intraoculaire moyenne ou absente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents field, petrographic-structural and geochemical data on spinet and plagioclase peridotites from the southern domain of the Lanzo ophiolitic peridotite massif (Western Alps). Spinet lherzolites, harzburgites and dunites crop out at Mt. Arpone and Mt. Musine. Field evidence indicates that pristine porphyroclastic spinet lherzolites are transformed to coarse granular spinet harzburgites, which are in turn overprinted by plagioclase peridotites, while strongly depleted spinet harzburgite and dunite bands and bodies replace the plagioclase peridotites. On the northern flank of Mt. Arpone, deformed, porphyroclastic (lithospheric) lherzolites, with diffuse pyroxenite banding, represent the oldest spinel-facies rocks. They show microstructures of a composite subsolidus evolution, suggesting provenance from deeper (asthenospheric) mantle levels and accretion to the lithosphere. These protoliths are locally transformed to coarse granular (reactive) spinet harzburgites and dunites, which show textures reminiscent of melt/rock reaction and geochemical characteristics suggesting that they are products of peridotite interaction with reactively percolating melts. Geochemical data and modelling suggest that <1-5% fractional melting of spinel-facies DMM produced the injected melts. Plagioclase peridotites are hybrid rocks resulting from pre-existing spinet peridotites and variable enrichment of plagioclase and micro-gabbroic material by percolating melts. The impregnating melts attained silica-saturation, as testified by widespread orthopyroxene replacement of olivine, during open system migration in the lithosphere. At Mt. Musine, coarse granular spinet harzburgite and dunite bodies replace the plagioclase peridotites. Most of these replacive, refractory peridotites have interstitial magmatic clinopyroxene with trace element compositions in equilibrium with MORB, while some Cpx have REE-depleted patterns suggesting transient geochemical features of the migrating MORB-type melts, acquired by interaction with the ambient plagioclase peridotite. These replacive spinet harzburgite and dunite bodies are interpreted as channels exploited for focused and reactive migration of silica-undersaturated melts with aggregate MORB compositions. Such melts were unrelated to the silica-saturated melts that refertilized the pre-existing plagioclase peridotites. Finally, MORB melt migration occurred along open fractures, now recorded as gabbroic dikes. Our data document the complexity of rock-types and mantle processes in the South Lanzo peridotite massif and describe a composite tectonic and magmatic scenario that is not consistent with the ``asthenospheric scenario'' proposed by previous authors. We envisage a ``transitional scenario'' in which extending subcontinental lithospheric mantle was strongly modified (both depleted and refertilized) by early melts with MORB-affinity formed by decompression partial melting of the upwelling asthenosphere, during pre-oceanic rifting and lithospheric thinning in the Ligurian Tethys realm. (C) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This letter presents advanced classification methods for very high resolution images. Efficient multisource information, both spectral and spatial, is exploited through the use of composite kernels in support vector machines. Weighted summations of kernels accounting for separate sources of spectral and spatial information are analyzed and compared to classical approaches such as pure spectral classification or stacked approaches using all the features in a single vector. Model selection problems are addressed, as well as the importance of the different kernels in the weighted summation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In spite of numerous applications of carbon nanofibers (CNFs) in a variety of fields, the potential release of airborne CNF during their special application, which could lead to workers or end-users exposure, has not been well investigated. In this study, the potential release of CNF from an organic vapour respirator cartridge was evaluated by carbon analysis and microscopy analysis. The cartridge consisted of an AC (Activated Carbon)/CNF composite adsorbent and different types of particulate filters. The composite adsorbent CNF were prepared by chemical vapour deposition (CVD). Air was passed through the prepared cartridge for 12 hours at 12 l/min and particles were collected on sampling filters suitable for measuring organic and elemental carbon (OC/EC) by carbon analysis based on the NIOSH 5040 method. Breakthrough of CNFs was also checked by scanning and transmission electron microscopy (SEM/TEM). This study found only minimal amounts of released elemental carbon while passing the air through the cartridge. Meanwhile TEM photos showed a few CNF structures for AC/CNF composite adsorbents which were not in the critical range in terms of length, aspect ratio, or number. [Authors]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background, aim, and scope A coupled Life Cycle Costing and life cycle assessment has been performed for car-bodies of the Korean Tilting Train eXpress (TTX) project using European and Korean databases, with the objective of assessing environmental and cost performance to aid materials and process selection. More specifically, the potential of polymer composite car-body structures for the Korean Tilting Train eXpress (TTX) has been investigated. Materials and methods This assessment includes the cost of both carriage manufacturing and use phases, coupled with the life cycle environmental impacts of all stages from raw material production, through carriage manufacture and use, to end-of-life scenarios. Metallic carriages were compared with two composite options: hybrid steel-composite and full-composite carriages. The total planned production for this regional Korean train was 440 cars, with an annual production volume of 80 cars. Results and discussion The coupled analyses were used to generate plots of cost versus energy consumption and environmental impacts. The results show that the raw material and manufacturing phase costs are approximately half of the total life cycle costs, whilst their environmental impact is relatively insignificant (3-8%). The use phase of the car-body has the largest environmental impact for all scenarios, with near negligible contributions from the other phases. Since steel rail carriages weigh more (27-51%), the use phase cost is correspondingly higher, resulting in both the greatest environmental impact and the highest life cycle cost. Compared to the steel scenario, the hybrid composite variant has a lower life cycle cost (16%) and a lower environmental impact (26%). Though the full composite rail carriage may have the highest manufacturing cost, it results in the lowest total life cycle costs and lowest environmental impacts. Conclusions and recommendations This coupled cost and life cycle assessment showed that the full composite variant was the optimum solution. This case study showed that coupling of technical cost models with life cycle assessment offers an efficient route to accurately evaluate economic and environmental performance in a consistent way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many colour ornaments are composite traits consisting of at least four components, which themselves may be more complex, determined by independent evolutionary pathways, and potentially being under different environmental control. To date, little evidence exists that several different components of colour elaboration are condition dependent and no direct evidence exists that different ornamental components are affected by different sources of variation. For example, in carotenoid-based plumage colouration, one of the best-known condition-dependent ornaments, colour elaboration stems from both condition-dependent pigment concentration and structural components. Some environmental flexibility of these components has been suggested, but specifically which and how they are affected remains unknown. Here, we tested whether multiple colour components may be condition dependent, by using a comprehensive 3 × 2 experimental design, in which we carotenoid supplemented and immune challenged great tit nestlings (Parus major) and quantified effects on different components of colouration. Plumage colouration was affected by an interaction between carotenoid availability and immune challenge. Path analyses showed that carotenoid supplementation increased plumage saturation via feather carotenoid concentration and via mechanisms unrelated to carotenoid deposition, while immune challenge affected feather length, but not carotenoid concentration. Thus, independent condition-dependent pathways, affected by different sources of variation, determine colour elaboration. This provides opportunities for the evolution of multiple signals within components of ornamental traits. This finding indicates that the selective forces shaping the evolution of different components of a composite trait and the trait's signal content may be more complex than believed so far, and that holistic approaches are required for drawing comprehensive evolutionary conclusions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical experience and experimental data suggest that intradialytic hemodynamic profiles could be influenced by the characteristics of the dialysis membranes. Even within the worldwide used polysulfone family, intolerance to specific membranes was occasionally evoked. The aim of this study was to compare hemodynamically some of the commonly used polysulfone dialyzers in Switzerland. We performed an open-label, randomized, cross-over trial, including 25 hemodialysis patients. Four polysulfone dialyzers, A (Revaclear high-flux, Gambro, Stockholm, Sweden), B (Helixone high-flux, Fresenius), C (Xevonta high-flux, BBraun, Melsungen, Germany), and D (Helixone low-flux, Fresenius, Bad Homburg vor der Höhe, Germany), were compared. The hemodynamic profile was assessed and patients were asked to provide tolerance feedback. The mean score (±SD) subjectively assigned to dialysis quality on a 1-10 scale was A 8.4 ± 1.3, B 8.6 ± 1.3, C 8.5 ± 1.6, D 8.5 ± 1.5. Kt/V was A 1.58 ± 0.30, B 1.67 ± 0.33, C 1.62 ± 0.32, D 1.45 ± 0.31. The low- compared with the high-flux membranes, correlated to higher systolic (128.1 ± 13.1 vs. 125.6 ± 12.1 mmHg, P < 0.01) and diastolic (76.8 ± 8.7 vs. 75.3 ± 9.0 mmHg; P < 0.05) pressures, higher peripheral resistance (1.44 ± 0.19 vs. 1.40 ± 0.18 s × mmHg/mL; P < 0.05) and lower cardiac output (3.76 ± 0.62 vs. 3.82 ± 0.59 L/min; P < 0.05). Hypotension events (decrease in systolic blood pressure by >20 mmHg) were 70 with A, 87 with B, 73 with C, and 75 with D (P < 0.01 B vs. A, 0.05 B vs. C and 0.07 B vs. D). The low-flux membrane correlated to higher blood pressure levels compared with the high-flux ones. The Helixone high-flux membrane ensured the best efficiency. Unfortunately, the very same dialyzer correlated to a higher incidence of hypotensive episodes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les membranes de dialyse à haut flux et à faible flux pourraient être liées à différents profils hemodynamiques pendant les séances de dialyse. Cette étude visait à comparer le profil hémodynamique des certains filtres de dialyse polysulfone couramment utilisés en Suisse. Nous avons réalisé une étude ouverte, cross-over, avec 25 pazients en hémodialyse On a comparés entre eux 4 filtres de polysulfone de la surface de 1 8 m2 A (Revaclear HF, Gambro), B (Helixone HF, Fresenius), C (Xevonta HF, BBraun) et D (Helixone LF Fresenius). Le profil hémodynamique a été mesuré en utilisant une technique non invasive et au patient a été demandé de fournir une opinion sur la tolérance à la seance de dialyse. La même membrane était utilisée pour 3 séances de suites Chaque semaine la membrane de dialyse était modifiée conformément à la séquence de randomisation. Pour chaque patient on a recueillie les données de 12 séances de dialyse. L'étude a été réalisé sur trois mois à compter de novembre 2012. Les analyses ont encore une fois montré la supériorité des filtres à haut débit comparés aux filtres à faible débit, et ne tendance à la supériorité du filtre Helixone (haut debit) comparé aux deux autres membranes. Les filtres à faible débit par rapport a ceux a haut debit sont associés ä une pression systolique et diastolique plus élevées a des résistances périphériques plus hautes et à un débit cardiaque plus faible L incidence d'épisodes d'hypotension en dialyse était la suivante: Revaclear HF (A) 70 Helixone HF (B) 87 Xevonta HF 73 (C), Helixone LF (D) 75. Le nombre d'épisodes d hypotension associée au filtre B était supérieure, de manière significative. La membrane à faible flux était associée à une pression artérielle supérieure à celles des membranes de haut flux. La membrane à haut flux Helixone garantie la meilleure efficacité de dialyse. Malheureusement, la même membrane est associée à une augmentation de l'incidence des épisodes d'hypotension, probablement due à un déséquilibré hé à l'efficacité de la dialyse. Malgré ces résultats, la tolérance subjective pour les différents filtres était comparable.