99 resultados para Quality control -- Management


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The discussion about setting up a program for lung cancer screening was launched with the publication of the results of the National Lung Screening Trial, which suggested reduced mortality in high-risk subjects undergoing CT screening. However, important questions about the benefit-harm balance and the details of a screening program and its cost-effectiveness remain unanswered. A panel of specialists in chest radiology, respiratory medicine, epidemiology, and thoracic surgery representing all Swiss university hospitals prepared this joint statement following several meetings. The panel argues that premature and uncontrolled introduction of a lung cancer screening program may cause substantial harm that may remain undetected without rigorous quality control. This position paper focuses on the requirements of running such a program with the objective of harmonizing efforts across the involved specialties and institutions and defining quality standards. The underlying statement includes information on current evidence for a reduction in mortality with lung cancer screening and the potential epidemiologic implications of such a program in Switzerland. Furthermore, requirements for lung cancer screening centers are defined, and recommendations for both the CT technique and the algorithm for lung nodule assessment are provided. In addition, related issues such as patient management, registry, and funding are addressed. Based on the current state of the knowledge, the panel concludes that lung cancer screening in Switzerland should be undertaken exclusively within a national observational study in order to provide answers to several critical questions before considering broad population-based screening for lung cancer.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Diabetes is a recognized risk factor for cardiovascular diseases and heart failure. Diabetic cardiovascular dysfunction also underscores the development of diabetic retinopathy, nephropathy and neuropathy. Despite the broad availability of antidiabetic therapy, glycemic control still remains a major challenge in the management of diabetic patients. Hyperglycemia triggers formation of advanced glycosylation end products (AGEs), activates protein kinase C, enhances polyol pathway, glucose autoxidation, which coupled with elevated levels of free fatty acids, and leptin have been implicated in increased generation of superoxide anion by mitochondria, NADPH oxidases and xanthine oxidoreductase in diabetic vasculature and myocardium. Superoxide anion interacts with nitric oxide forming the potent toxin peroxynitrite via diffusion limited reaction, which in concert with other oxidants triggers activation of stress kinases, endoplasmic reticulum stress, mitochondrial and poly(ADP-ribose) polymerase 1-dependent cell death, dysregulates autophagy/mitophagy, inactivates key proteins involved in myocardial calcium handling/contractility and antioxidant defense, activates matrix metalloproteinases and redox-dependent pro-inflammatory transcription factors (e.g. nuclear factor kappaB) promoting inflammation, AGEs formation, eventually culminating in myocardial dysfunction, remodeling and heart failure. Understanding the complex interplay of oxidative/nitrosative stress with pro-inflammatory, metabolic and cell death pathways is critical to devise novel targeted therapies for diabetic cardiomyopathy, which will be overviewed in this brief synopsis. This article is part of a Special Issue entitled: Autophagy and protein quality control in cardiometabolic diseases.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: Urine is still the matrix of choice to fight against doping, because it can be collected non-invasively during anti-doping tests. Most of the World Anti-Doping Agency's accredited laboratories have more than 20 years experience in analyzing this biological fluid and the majority of the compounds listed in the 2010 Prohibited List - International Standard are eliminated through the urinary apparatus. Storing and transporting urine samples for doping analyses does not include a specific protocol to prevent microbial and thermal degradation. The use of a rapid and reliable screening method could enable determine reference intervals for urine specimens in doping control samples and evaluate notably the prevalence of microbial contamination known to be responsible for the degradation of chemical substances in urine.Methods: The Sysmex(R) UF-500i is a recent urine flow cytometer analyzer capable of quantifying BACT and other urinary particles such as RBC, WBC, EC, DEBRIS, CAST, PATH. CAST, YLC, SRC as well as measuring urine conductivity. To determine urine anti-doping reference intervals, 501 samples received in our laboratory over a period of two months were submitted to an immediate examination. All samples were collected and then transported at room temperature. Analysis of variance was performed to test the effects of factors such as gender, test type [in-competition, out-of-competition] and delivery time.Results: The data obtained showed that most of the urine samples were highly contaminated with bacteria. The other urine particles were also very different according to the factors.Conclusions: The Sysmex(R) UF-500i was capable of providing a snapshot of urine particles present in the samples at the time of the delivery to the laboratory. These particles, BACT in particular, gave a good idea of the possible microbial degradation which had and/or could have occurred in the sample. This information could be used as the first quality control set up in WADA (World Anti-Doping Agency) accredited laboratories to determine if steroid profiles, endogenous and prohibited substances have possibly been altered. (C) 2011 Elsevier Ireland Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of radiotherapy is to deliver enough radiation to the tumor in order to achieve maximum tumour control in the irradiated volume with as few serious complications as possible with an irradiation dose as low as possible to normal tissue. The quality of radiotherapy is essential for optimal treatment and quality control is to reduce the bias in clinical trials avoiding possible major deviations. The assurance and quality control programs have been developed in large european (EORTC, GORTEC) and american cooperative groups (RTOG) of radiation oncology since the 1980s. We insist here on the importance of quality assurance in radiotherapy and the current status in this domain and the criteria for quality control especially for current clinical trials within GORTEC are discussed here.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Worldwide data for cancer survival are scarce. We aimed to initiate worldwide surveillance of cancer survival by central analysis of population-based registry data, as a metric of the effectiveness of health systems, and to inform global policy on cancer control. METHODS: Individual tumour records were submitted by 279 population-based cancer registries in 67 countries for 25·7 million adults (age 15-99 years) and 75 000 children (age 0-14 years) diagnosed with cancer during 1995-2009 and followed up to Dec 31, 2009, or later. We looked at cancers of the stomach, colon, rectum, liver, lung, breast (women), cervix, ovary, and prostate in adults, and adult and childhood leukaemia. Standardised quality control procedures were applied; errors were corrected by the registry concerned. We estimated 5-year net survival, adjusted for background mortality in every country or region by age (single year), sex, and calendar year, and by race or ethnic origin in some countries. Estimates were age-standardised with the International Cancer Survival Standard weights. FINDINGS: 5-year survival from colon, rectal, and breast cancers has increased steadily in most developed countries. For patients diagnosed during 2005-09, survival for colon and rectal cancer reached 60% or more in 22 countries around the world; for breast cancer, 5-year survival rose to 85% or higher in 17 countries worldwide. Liver and lung cancer remain lethal in all nations: for both cancers, 5-year survival is below 20% everywhere in Europe, in the range 15-19% in North America, and as low as 7-9% in Mongolia and Thailand. Striking rises in 5-year survival from prostate cancer have occurred in many countries: survival rose by 10-20% between 1995-99 and 2005-09 in 22 countries in South America, Asia, and Europe, but survival still varies widely around the world, from less than 60% in Bulgaria and Thailand to 95% or more in Brazil, Puerto Rico, and the USA. For cervical cancer, national estimates of 5-year survival range from less than 50% to more than 70%; regional variations are much wider, and improvements between 1995-99 and 2005-09 have generally been slight. For women diagnosed with ovarian cancer in 2005-09, 5-year survival was 40% or higher only in Ecuador, the USA, and 17 countries in Asia and Europe. 5-year survival for stomach cancer in 2005-09 was high (54-58%) in Japan and South Korea, compared with less than 40% in other countries. By contrast, 5-year survival from adult leukaemia in Japan and South Korea (18-23%) is lower than in most other countries. 5-year survival from childhood acute lymphoblastic leukaemia is less than 60% in several countries, but as high as 90% in Canada and four European countries, which suggests major deficiencies in the management of a largely curable disease. INTERPRETATION: International comparison of survival trends reveals very wide differences that are likely to be attributable to differences in access to early diagnosis and optimum treatment. Continuous worldwide surveillance of cancer survival should become an indispensable source of information for cancer patients and researchers and a stimulus for politicians to improve health policy and health-care systems. FUNDING: Canadian Partnership Against Cancer (Toronto, Canada), Cancer Focus Northern Ireland (Belfast, UK), Cancer Institute New South Wales (Sydney, Australia), Cancer Research UK (London, UK), Centers for Disease Control and Prevention (Atlanta, GA, USA), Swiss Re (London, UK), Swiss Cancer Research foundation (Bern, Switzerland), Swiss Cancer League (Bern, Switzerland), and University of Kentucky (Lexington, KY, USA).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND & AIMS: Trace elements (TE) are involved in the immune and antioxidant defences which are of particular importance during critical illness. Determining plasma TE levels is costly. The present quality control study aimed at assessing the economic impact of a computer reminded blood sampling versus a risk guided on-demand monitoring of plasma concentrations of selenium, copper, and zinc. METHODS: Retrospective analysis of 2 cohorts of patients admitted during 6 months periods in 2006 and 2009 to the ICU of a University hospital. INCLUSION CRITERIA: to receive intravenous micronutrient supplements and/or to have a TE sampling during ICU stay. The TE samplings were triggered by computerized reminder in 2006 versus guided by nutritionists in 2009. RESULTS: During the 2 periods 636 patients met the inclusion criteria out of 2406 consecutive admissions, representing 29.7% and 24.9% respectively of the periods' admissions. The 2009 patients had higher SAPS2 scores (p = 0.02) and lower BMI compared to 2006 (p = 0.007). The number of laboratory determinations was drastically reduced in 2009, particularly during the first week, despite the higher severity of the cohort, resulting in à 55% cost reduction. CONCLUSIONS: The monitoring of TE concentrations guided by a nutritionist resulted in a reduction of the sampling frequency, and targeting on the sickest high risk patients, requiring a nutritional prescription adaptation. This control leads to cost reduction compared to an automated sampling prescription.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Human biomonitoring (HBM) is an effective tool for assessing actual exposure to chemicals that takes into account all routes of intake. Although hair analysis is considered to be an optimal biomarker for assessing mercury exposure, the lack of harmonization as regards sampling and analytical procedures has often limited the comparison of data at national and international level. The European-funded projects COPHES and DEMOCOPHES developed and tested a harmonized European approach to Human Biomonitoring in response to the European Environment and Health Action Plan. Herein we describe the quality assurance program (QAP) for assessing mercury levels in hair samples from more than 1800 mother-child pairs recruited in 17 European countries. To ensure the comparability of the results, standard operating procedures (SOPs) for sampling and for mercury analysis were drafted and distributed to participating laboratories. Training sessions were organized for field workers and four external quality-assessment exercises (ICI/EQUAS), followed by the corresponding web conferences, were organized between March 2011 and February 2012. ICI/EQUAS used native hair samples at two mercury concentration ranges (0.20-0.71 and 0.80-1.63) per exercise. The results revealed relative standard deviations of 7.87-13.55% and 4.04-11.31% for the low and high mercury concentration ranges, respectively. A total of 16 out of 18 participating laboratories the QAP requirements and were allowed to analyze samples from the DEMOCOPHES pilot study. Web conferences after each ICI/EQUAS revealed this to be a new and effective tool for improving analytical performance and increasing capacity building. The procedure developed and tested in COPHES/DEMOCOPHES would be optimal for application on a global scale as regards implementation of the Minamata Convention on Mercury.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Evaluation of image quality (IQ) in Computed Tomography (CT) is important to ensure that diagnostic questions are correctly answered, whilst keeping radiation dose to the patient as low as is reasonably possible. The assessment of individual aspects of IQ is already a key component of routine quality control of medical x-ray devices. These values together with standard dose indicators can be used to give rise to 'figures of merit' (FOM) to characterise the dose efficiency of the CT scanners operating in certain modes. The demand for clinically relevant IQ characterisation has naturally increased with the development of CT technology (detectors efficiency, image reconstruction and processing), resulting in the adaptation and evolution of assessment methods. The purpose of this review is to present the spectrum of various methods that have been used to characterise image quality in CT: from objective measurements of physical parameters to clinically task-based approaches (i.e. model observer (MO) approach) including pure human observer approach. When combined together with a dose indicator, a generalised dose efficiency index can be explored in a framework of system and patient dose optimisation. We will focus on the IQ methodologies that are required for dealing with standard reconstruction, but also for iterative reconstruction algorithms. With this concept the previously used FOM will be presented with a proposal to update them in order to make them relevant and up to date with technological progress. The MO that objectively assesses IQ for clinically relevant tasks represents the most promising method in terms of radiologist sensitivity performance and therefore of most relevance in the clinical environment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Assays that measure a patient's immune response play an increasingly important role in the development of immunotherapies. The inherent complexity of these assays and independent protocol development between laboratories result in high data variability and poor reproducibility. Quality control through harmonization--based on integration of laboratory-specific protocols with standard operating procedures and assay performance benchmarks--is one way to overcome these limitations. Harmonization guidelines can be widely implemented to address assay performance variables. This process enables objective interpretation and comparison of data across clinical trial sites and also facilitates the identification of relevant immune biomarkers, guiding the development of new therapies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: As part of the MicroArray Quality Control (MAQC)-II project, this analysis examines how the choice of univariate feature-selection methods and classification algorithms may influence the performance of genomic predictors under varying degrees of prediction difficulty represented by three clinically relevant endpoints. Methods: We used gene-expression data from 230 breast cancers (grouped into training and independent validation sets), and we examined 40 predictors (five univariate feature-selection methods combined with eight different classifiers) for each of the three endpoints. Their classification performance was estimated on the training set by using two different resampling methods and compared with the accuracy observed in the independent validation set. Results: A ranking of the three classification problems was obtained, and the performance of 120 models was estimated and assessed on an independent validation set. The bootstrapping estimates were closer to the validation performance than were the cross-validation estimates. The required sample size for each endpoint was estimated, and both gene-level and pathway-level analyses were performed on the obtained models. Conclusions: We showed that genomic predictor accuracy is determined largely by an interplay between sample size and classification difficulty. Variations on univariate feature-selection methods and choice of classification algorithm have only a modest impact on predictor performance, and several statistically equally good predictors can be developed for any given classification problem.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Type 2 diabetes mellitus (T2DM) is a major disease affecting nearly 280 million people worldwide. Whilst the pathophysiological mechanisms leading to disease are poorly understood, dysfunction of the insulin-producing pancreatic beta-cells is key event for disease development. Monitoring the gene expression profiles of pancreatic beta-cells under several genetic or chemical perturbations has shed light on genes and pathways involved in T2DM. The EuroDia database has been established to build a unique collection of gene expression measurements performed on beta-cells of three organisms, namely human, mouse and rat. The Gene Expression Data Analysis Interface (GEDAI) has been developed to support this database. The quality of each dataset is assessed by a series of quality control procedures to detect putative hybridization outliers. The system integrates a web interface to several standard analysis functions from R/Bioconductor to identify differentially expressed genes and pathways. It also allows the combination of multiple experiments performed on different array platforms of the same technology. The design of this system enables each user to rapidly design a custom analysis pipeline and thus produce their own list of genes and pathways. Raw and normalized data can be downloaded for each experiment. The flexible engine of this database (GEDAI) is currently used to handle gene expression data from several laboratory-run projects dealing with different organisms and platforms. Database URL: http://eurodia.vital-it.ch.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background and aims: Family-centred care is an expected standard in PICU and parent reported outcomes are rarely measured. The Dutch validated EMPATHIC questionnaire provides accurate measures of parental perceptions of family-centred care in PICU. A French version would provide an important resource for quality control and benchmarking with other PICUs. The study aimed to translate and to assess the French cultural adaptation of the EMPATHIC questionnaire. Methods: In September 2012, following approval from the developer, translation and cultural adaptation were performed using a structured method (Wild et al. 2005). This included forward-backward translation and reconciliation by an official translator, harmonization assessed by the research team, and cognitive debriefing with the target users' population. In this last step, a convenience sample of parents with PICU experience assessed the comprehensibility and cultural relevance of the 65-item French EMPATHIC questionnaire. The PICUs in Lausanne, Switzerland and Lille, France participated. Results: Seventeen parents, including 13 French native and 4 French as second language speakers, tested the cognitive equivalence and cultural relevance of the French EMPATHIC questionnaire. The mean agreement for comprehensibility of all 65 items reached 90.2%. Three items fell below the cut-off 80% agreement and were revised for inclusion in the final French version. Conclusions: The translation and the cultural adaptation permitted to highlight a few cultural differences that did not interfere with the main construct of the EMPATHIC questionnaire. Reliability and validity testing with a new sample of parents is needed to strengthen the psychometric properties of the French EMPATHIC questionnaire.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Artificial antigen-presenting cells (aAPC) are widely used for both clinical and basic research applications, as cell-based or bead-based scaffolds, combining immune synapse components of interest. Adequate and controlled preparation of aAPCs is crucial for subsequent immunoassays. We reveal that certain proteins such as activatory anti-CD3 antibody can be out-competed by other proteins (e.g. inhibitory receptor ligands such as PDL1:Fc) during the coating of aAPC beads, under the usually performed coating procedures. This may be misleading, as we found that decreased CD8 T cell activity was not due to inhibitory receptor triggering but rather because of unexpectedly low anti-CD3 antibody density on the beads upon co-incubation with inhibitory receptor ligands. We propose an optimized protocol, and emphasize the need to quality-control the coating of proteins on aAPC beads prior to their use in immunoassays.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The International Molecular Exchange (IMEx) consortium is an international collaboration between major public interaction data providers to share literature-curation efforts and make a nonredundant set of protein interactions available in a single search interface on a common website (http://www.imexconsortium.org/). Common curation rules have been developed, and a central registry is used to manage the selection of articles to enter into the dataset. We discuss the advantages of such a service to the user, our quality-control measures and our data-distribution practices.