299 resultados para Posteroanterior motion test
Resumo:
Functional imaging with intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) is demonstrated. Images were acquired at 3 Tesla using a standard Stejskal-Tanner diffusion-weighted echo-planar imaging sequence with multiple b-values. Cerebro-spinal fluid signal, which is highly incoherent, was suppressed with an inversion recovery preparation pulse. IVIM microvascular perfusion parameters were calculated according to a two-compartment (vascular and non-vascular) diffusion model. The results obtained in 8 healthy human volunteers during visual stimulation are presented. The IVIM blood flow related parameter fD* increased 170% during stimulation in the visual cortex, and 70% in the underlying white matter.
Resumo:
The National Institute of Mental Health developed the semi-structured Diagnostic Interview for Genetic Studies (DIGS) for the assessment of major mood and psychotic disorders and their spectrum conditions. The DIGS was translated into French in a collaborative effort of investigators from sites in France and Switzerland. Inter-rater and test-retest reliability of the French version have been established in a clinical sample in Lausanne. Excellent inter-rater reliability was found for schizophrenia, bipolar disorder, major depression, and unipolar schizoaffective disorder while fair inter-rater reliability was demonstrated for bipolar schizoaffective disorder. Using a six-week test-retest interval, reliability for all diagnoses was found to be fair to good with the exception of bipolar schizoaffective disorder. The lower test-retest reliability was the result of a relatively long test-retest interval that favored incomplete symptom recall. In order to increase reliability for lifetime diagnoses in persons not currently affected, best-estimate procedures using additional sources of diagnostic information such as medical records and reports from relatives should supplement DIGS information in family-genetic studies. Within such a procedure, the DIGS appears to be a useful part of data collection for genetic studies on major mood disorders and schizophrenia in French-speaking populations.
Resumo:
Purpose: To evaluate the sensitivity of the perfusion parameters derived from Intravoxel Incoherent Motion (IVIM) MR imaging to hypercapnia-induced vasodilatation and hyperoxygenation-induced vasoconstriction in the human brain. Materials and Methods: This study was approved by the local ethics committee and informed consent was obtained from all participants. Images were acquired with a standard pulsed-gradient spin-echo sequence (Stejskal-Tanner) in a clinical 3-T system by using 16 b values ranging from 0 to 900 sec/mm(2). Seven healthy volunteers were examined while they inhaled four different gas mixtures known to modify brain perfusion (pure oxygen, ambient air, 5% CO(2) in ambient air, and 8% CO(2) in ambient air). Diffusion coefficient (D), pseudodiffusion coefficient (D*), perfusion fraction (f), and blood flow-related parameter (fD*) maps were calculated on the basis of the IVIM biexponential model, and the parametric maps were compared among the four different gas mixtures. Paired, one-tailed Student t tests were performed to assess for statistically significant differences. Results: Signal decay curves were biexponential in the brain parenchyma of all volunteers. When compared with inhaled ambient air, the IVIM perfusion parameters D*, f, and fD* increased as the concentration of inhaled CO(2) was increased (for the entire brain, P = .01 for f, D*, and fD* for CO(2) 5%; P = .02 for f, and P = .01 for D* and fD* for CO(2) 8%), and a trend toward a reduction was observed when participants inhaled pure oxygen (although P > .05). D remained globally stable. Conclusion: The IVIM perfusion parameters were reactive to hyperoxygenation-induced vasoconstriction and hypercapnia-induced vasodilatation. Accordingly, IVIM imaging was found to be a valid and promising method to quantify brain perfusion in humans. © RSNA, 2012.
Resumo:
This study describes the validation of a new wearable system for assessment of 3D spatial parameters of gait. The new method is based on the detection of temporal parameters, coupled to optimized fusion and de-drifted integration of inertial signals. Composed of two wirelesses inertial modules attached on feet, the system provides stride length, stride velocity, foot clearance, and turning angle parameters at each gait cycle, based on the computation of 3D foot kinematics. Accuracy and precision of the proposed system were compared to an optical motion capture system as reference. Its repeatability across measurements (test-retest reliability) was also evaluated. Measurements were performed in 10 young (mean age 26.1±2.8 years) and 10 elderly volunteers (mean age 71.6±4.6 years) who were asked to perform U-shaped and 8-shaped walking trials, and then a 6-min walking test (6MWT). A total of 974 gait cycles were used to compare gait parameters with the reference system. Mean accuracy±precision was 1.5±6.8cm for stride length, 1.4±5.6cm/s for stride velocity, 1.9±2.0cm for foot clearance, and 1.6±6.1° for turning angle. Difference in gait performance was observed between young and elderly volunteers during the 6MWT particularly in foot clearance. The proposed method allows to analyze various aspects of gait, including turns, gait initiation and termination, or inter-cycle variability. The system is lightweight, easy to wear and use, and suitable for clinical application requiring objective evaluation of gait outside of the lab environment.
Resumo:
Ventricular assist devices (VADs) are used in treatment for terminal heart failure or as a bridge to transplantation. We created biVAD using the artificial muscles (AMs) that supports both ventricles at the same time. We developed the test bench (TB) as the in vitro evaluating system to enable the measurement of performance. The biVAD exerts different pressure between left and right ventricle like the heart physiologically does. The heart model based on child's heart was constructed in silicone. This model was fitted with the biVAD. Two pipettes containing water with an ultrasonic sensor placed on top of each and attached to ventricles reproduced the preload and the after load of each ventricle by the real-time measurement of the fluid height variation proportionally to the exerted pressure. The LabVIEW software extrapolated the displaced volume and the pressure generated by each side of our biVAD. The development of a standardized protocol permitted the validation of the TB for in vitro evaluation, measurement of the performances of the AM biVAD herein, and reproducibility of data.
Resumo:
Cannula design is of prime importance for venous drainage during cardiopulmonary bypass (CPB). To evaluate cannulas intended for CPB, an in vitro circuit was set up with silicone tubing between the test cannula encased in a movable preload reservoir and another static reservoir. The pressure-drop (DeltaP) value (P-drainage - P-preload) was measured using Millar pressure transducers. Flow rate (Q) was measured using an ultrasound flowmeter. Data display and data recording were controlled using a LabView application, custom made particularly for our experiments. Our results demonstrated that DeltaP, Q, and cannula resistance (DeltaP/Q) values were significantly decreased when the cannula diameter was increased for Smart and Medtronic cannulas. Smartcanula showed 36% and 43% less resistance compared to Medtronic venous and Medtronic femoral cannulas, respectively. The cannula shape (straight- or curved-tips) did not affect the DLP cannula resistance. Out of five cannulas tested, the Smartcanula outperforms the other commercially available cannulas. The mean (DeltaP/Q) values were 3.3 +/- 0.08, 4.07 +/- 0.08, 5.58 +/- 0.10, 5.74 +/- 0.15, and 6.45 +/- 0.15 for Smart, Medtronic, Edwards, Sarns, and Gambro cannulas, respectively (two-way ANOVA, p < 0.0001). In conclusion, the present assay allows discrimination between different forms of cannula with high or low lumen resistance.
Resumo:
Screening for latent tuberculosis infection (LTBI) is recommended prior to organ transplantation. The Quantiferon-TB Gold assay (QFT-G) may be more accurate than the tuberculin skin test (TST) in the detection of LTBI. We prospectively compared the results of QFT-G to TST in patients with chronic liver disease awaiting transplantation. Patients were screened for LTBI with both the QFT-G test and a TST. Concordance between test results and predictors of a discordant result were determined. Of the 153 evaluable patients, 37 (24.2%) had a positive TST and 34 (22.2%) had a positive QFT-G. Overall agreement between tests was 85.1% (kappa= 0.60, p < 0.0001). Discordant test results were seen in 12 TST positive/QFT-G negative patients and in 9 TST negative/QFT-G positive patients. Prior BCG vaccination was not associated with discordant test results. Twelve patients (7.8%), all with a negative TST, had an indeterminate result of the QFT-G and this was more likely in patients with a low lymphocyte count (p = 0.01) and a high MELD score (p = 0.001). In patients awaiting liver transplantation, both the TST and QFT-G were comparable for the diagnosis of LTBI with reasonable concordance between tests. Indeterminate QFT-G result was more likely in those with more advanced liver disease.
Resumo:
PURPOSE: To document the neurological outcome, spinal alignment and segmental range of movement after oblique cervical corpectomy (OCC) for cervical compressive myelopathy. METHODS: This retrospective study included 109 patients--93 with cervical spondylotic myelopathy and 16 with ossified posterior longitudinal ligament in whom spinal curvature and range of segmental movements were assessed on neutral and dynamic cervical radiographs. Neurological function was measured by Nurick's grade and modified Japanese Orthopedic Association (JOA) scores. Eighty-eight patients (81%) underwent either a single- or two-level corpectomy; the remaining (19%) undergoing three- or four-level corpectomies. The average duration of follow-up was 30.52 months. RESULTS: The Nurick's grade and the JOA scores showed statistically significant improvements after surgery (p < 0.001). The mean postoperative segmental angle in the neutral position straightened by 4.7 ± 6.5°. The residual segmental range of movement for a single-level corpectomy was 16.7° (59.7% of the preoperative value), for two-level corpectomy it was 20.0° (67.2%) and for three-level corpectomies it was 22.9° (74.3%). 63% of patients with lordotic spines continued to have lordosis postoperatively while only one became kyphotic without clinical worsening. Four patients with preoperative kyphotic spines showed no change in spine curvature. None developed spinal instability. CONCLUSIONS: The OCC preserves segmental motion in the short-term, however, the tendency towards straightening of the spine, albeit without clinical worsening, warrants serial follow-up imaging to determine whether this motion preservation is long lasting.
Resumo:
Measurement of microvascular perfusion with Intravoxel Incoherent Motion (IVIM) MRI is gaining interest. Yet, the physiological influences on the IVIM perfusion parameters ("pseudo-diffusion" coefficient D*, perfusion fraction f, and flow related parameter fD*) remain insufficiently characterized. In this article, we hypothesize that D* and fD*, which depend on blood speed, should vary during the cardiac cycle. We extended the IVIM model to include time dependence of D* = D*(t), and demonstrate in the healthy human brain that both parameters D* and fD* are significantly larger during systole than diastole, while the diffusion coefficient D and f do not vary significantly. The results non-invasively demonstrate the pulsatility of the brain's microvasculature.
Resumo:
In the International Olympic Committee (IOC) accredited laboratories, specific methods have been developed to detect anabolic steroids in athletes' urine. The technique of choice to achieve this is gas-chromatography coupled with mass spectrometry (GC-MS). In order to improve the efficiency of anti-doping programmes, the laboratories have defined new analytical strategies. The final sensitivity of the analytical procedure can be improved by choosing new technologies for use in detection, such as tandem mass spectrometry (MS-MS) or high resolution mass spectrometry (HRMS). A better sample preparation using immuno-affinity chromatography (IAC) is also a good tool for improving sensitivity. These techniques are suitable for the detection of synthetic anabolic steroids whose structure is not found naturally in the human body. The more and more evident use, on a large scale, of substances chemically similar to the endogenous steroids obliges both the laboratory and the sports authorities to use the steroid profile of the athlete in comparison with reference ranges from a population or with intraindividual reference values.
Resumo:
This prospective study applies an extended Information-Motivation-Behavioural Skills (IMB) model to establish predictors of HIV-protection behaviour among HIV-positive men who have sex with men (MSM) during sex with casual partners. Data have been collected from anonymous, self-administered questionnaires and analysed by using descriptive and backward elimination regression analyses. In a sample of 165 HIV-positive MSM, 82 participants between the ages of 23 and 78 (M=46.4, SD=9.0) had sex with casual partners during the three-month period under investigation. About 62% (n=51) have always used a condom when having sex with casual partners. From the original IMB model, only subjective norm predicted condom use. More important predictors that increased condom use were low consumption of psychotropics, high satisfaction with sexuality, numerous changes in sexual behaviour after diagnosis, low social support from friends, alcohol use before sex and habitualised condom use with casual partner(s). The explanatory power of the calculated regression model was 49% (p<0.001). The study reveals the importance of personal and social resources and of routines for condom use, and provides information for the research-based conceptualisation of prevention offers addressing especially people living with HIV ("positive prevention").