108 resultados para Optimization procedures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Individual-as-maximizing agent analogies result in a simple understanding of the functioning of the biological world. Identifying the conditions under which individuals can be regarded as fitness maximizing agents is thus of considerable interest to biologists. Here, we compare different concepts of fitness maximization, and discuss within a single framework the relationship between Hamilton's (J Theor Biol 7: 1-16, 1964) model of social interactions, Grafen's (J Evol Biol 20: 1243-1254, 2007a) formal Darwinism project, and the idea of evolutionary stable strategies. We distinguish cases where phenotypic effects are additive separable or not, the latter not being covered by Grafen's analysis. In both cases it is possible to define a maximand, in the form of an objective function phi(z), whose argument is the phenotype of an individual and whose derivative is proportional to Hamilton's inclusive fitness effect. However, this maximand can be identified with the expression for fecundity or fitness only in the case of additive separable phenotypic effects, making individual-as-maximizing agent analogies unattractive (although formally correct) under general situations of social interactions. We also feel that there is an inconsistency in Grafen's characterization of the solution of his maximization program by use of inclusive fitness arguments. His results are in conflict with those on evolutionary stable strategies obtained by applying inclusive fitness theory, and can be repaired only by changing the definition of the problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Laboratory detection of vancomycin-intermediate Staphylococcus aureus (VISA) and their heterogeneous VISA (hVISA) precursors is difficult. Thus, it is possible that vancomycin failures against supposedly vancomycin-susceptible S. aureus are due to undiagnosed VISA or hVISA. We tested this hypothesis in experimental endocarditis.¦METHODS: Rats with aortic valve infection due to the vancomycin-susceptible (MIC 2 mg/L), methicillin-resistant S. aureus M1V2 were treated for 2 days with doses of vancomycin that mimicked the pharmacokinetics seen in humans following intravenous administration of 1 g of the drug every 12 h. Half of the treated animals were killed 8 h after treatment arrest and half 3 days thereafter. Population analyses were done directly on vegetation homogenates or after one subculture in drug-free medium to mimic standard diagnostic procedures.¦RESULTS: Vancomycin cured 14 of 26 animals (54%; P<0.05 versus controls) after 2 days of treatment. When vegetation homogenates were plated directly on vancomycin-containing plates, 6 of 13 rats killed 8 h after treatment arrest had positive cultures, 1 of which harboured hVISA. Likewise, 6 of 13 rats killed 3 days thereafter had positive valve cultures, 5 of which harboured hVISA. However, one subculture of vegetations in drug-free broth was enough to revert all the hVISA phenotypes to the susceptible pattern of the parent. Thus, vancomycin selected for hVISA during therapy of experimental endocarditis due to vancomycin-susceptible S. aureus. These hVISA were associated with vancomycin failure. The hVISA phenotype persisted in vivo, even after vancomycin arrest, but was missed in vitro after a single passage of the vegetation homogenate on drug-free medium.¦CONCLUSIONS: hVISA might escape detection in clinical samples if they are subcultured before susceptibility tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Percutaneous ablative procedures allow curative treatment of stage BCLC 0 or BCLC A hepatocellular carcinoma, as well as liver metastases of colorectal cancer. Several methods exist including radiofrequency ablation, the most commonly used. These techniques can be used in combination with surgical excision or alone if surgery is contraindicated. They are associated with significantly reduced mortality as compared to surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the context of Systems Biology, computer simulations of gene regulatory networks provide a powerful tool to validate hypotheses and to explore possible system behaviors. Nevertheless, modeling a system poses some challenges of its own: especially the step of model calibration is often difficult due to insufficient data. For example when considering developmental systems, mostly qualitative data describing the developmental trajectory is available while common calibration techniques rely on high-resolution quantitative data. Focusing on the calibration of differential equation models for developmental systems, this study investigates different approaches to utilize the available data to overcome these difficulties. More specifically, the fact that developmental processes are hierarchically organized is exploited to increase convergence rates of the calibration process as well as to save computation time. Using a gene regulatory network model for stem cell homeostasis in Arabidopsis thaliana the performance of the different investigated approaches is evaluated, documenting considerable gains provided by the proposed hierarchical approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article we present a novel approach for diffusion MRI global tractography. Our formulation models the signal in each voxel as a linear combination of fiber-tract basis func- tions, which consist of a comprehensive set of plausible fiber tracts that are locally compatible with the measured MR signal. This large dictionary of candidate fibers is directly estimated from the data and, subsequently, efficient convex optimization techniques are used for recovering the smallest subset globally best fitting the measured signal. Experimen- tal results conducted on a realistic phantom demonstrate that our approach significantly reduces the computational cost of global tractography while still attaining a reconstruction quality at least as good as the state-of-the-art global methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of ORAMED work package 4 was the optimization of the medical practices in nuclear medicine during the preparation of radiopharmaceuticals and their administration to the patient. During the project a wide campaign of measurements was performed in the nuclear medicine departments of the collaborating hospitals. Such data were intrinsically characterized by a large variability that depended on the procedure, the employed techniques and the operator's habits. That variability could easily hide some important parameter, for example, the effectiveness of the adopted shielding (for syringe and vial) or the effect of the distances from the source. This information is necessary for a valuable optimization purpose of radiation protection. To this end a sensitivity analysis was carried out through Monte Carlo simulations employing voxel models, representing operator's hand during the considered practices. Such analysis allowed understanding at what extent the range of personal dose equivalent evaluated during measurements can be considered intrinsically related to the procedures. Furthermore, with the Monte Carlo simulations it was possible to study the appropriateness of the shielding usually utilized in these practices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A basic prerequisite for in vivo X-ray imaging of the lung is the exact determination of radiation dose. Achieving resolutions of the order of micrometres may become particularly challenging owing to increased dose, which in the worst case can be lethal for the imaged animal model. A framework for linking image quality to radiation dose in order to optimize experimental parameters with respect to dose reduction is presented. The approach may find application for current and future in vivo studies to facilitate proper experiment planning and radiation risk assessment on the one hand and exploit imaging capabilities on the other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tumor Endothelial Marker-1 (TEM1/CD248) is a tumor vascular marker with high therapeutic and diagnostic potentials. Immuno-imaging with TEM1-specific antibodies can help to detect cancerous lesions, monitor tumor responses, and select patients that are most likely to benefit from TEM1-targeted therapies. In particular, near infrared(NIR) optical imaging with biomarker-specific antibodies can provide real-time, tomographic information without exposing the subjects to radioactivity. To maximize the theranostic potential of TEM1, we developed a panel of all human, multivalent Fc-fusion proteins based on a previously identified single chain antibody (scFv78) that recognizes both human and mouse TEM1. By characterizing avidity, stability, and pharmacokinectics, we identified one fusion protein, 78Fc, with desirable characteristics for immuno-imaging applications. The biodistribution of radiolabeled 78Fc showed that this antibody had minimal binding to normal organs, which have low expression of TEM1. Next, we developed a 78Fc-based tracer and tested its performance in different TEM1-expressing mouse models. The NIR imaging and tomography results suggest that the 78Fc-NIR tracer performs well in distinguishing mouse- or human-TEM1 expressing tumor grafts from normal organs and control grafts in vivo. From these results we conclude that further development and optimization of 78Fc as a TEM1-targeted imaging agent for use in clinical settings is warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of CT applications might become a public health problem if no effort is made on the justification and the optimisation of the examinations. This paper presents some hints to assure that the risk-benefit compromise remains in favour of the patient, especially when one deals with the examinations of young patients. In this context a particular attention has to be made on the justification of the examination. When performing the acquisition one needs to optimise the extension of the volume investigated together with the number of acquisition sequences used. Finally, the use of automatic exposure systems, now available on all the units, and the use of the Diagnostic Reference Levels (DRL) should allow help radiologists to control the exposure of their patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to use the Urinary Distress Inventory (UDI-6) and Incontinence Impact Quality of Life (IIQ-7) questionnaires to compare 3 surgical techniques for stress urinary incontinence: the transvaginal tape (TVT) (105 women), the transobturator tape outside-in (TOT) (43 women), and the transvaginal tape-obturator inside-out (TVT-O) (54 women). There were no significant differences in frequent urination, urine leakage related to the feeling of urgency, urine leakage related to physical activity, or small amounts of urine leakage. TVT-operated women had a lower percentage of micturition difficulties compared with TOT women. TVT-O-operated women described slight discomfort in the genital area compared with the TVT technique, but this difference was not significant when compared with the TOT technique. When utilizing the UDI-6 and IIQ-7 scoring modifications before and after surgery, no difference among these 3 techniques is apparent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For severe obesity (BMI > 35 kg/m2), bariatric surgery is not only the best, but often the only means of obtaining sufficient and durable weight loss. This article aims to review the available bariatric procedures. Gastric bypass remains the reference when it comes to the risk/benefit ratio. Gastric banding is declining rapidly due to the high prevalence of long-term complications. Primary malabsorptive procedures remain largely unpopular because of their potential nutritional complications. Sleeve gastrectomy, although it is not reversible as it includes a significant gastric resection, increases currently in popularity because of its apparent simplicity and the fact that early results regarding weight loss mimic those obtained with gastric bypass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Following the introduction of single-metal deposition (SMD), a simplified fingermark detection technique based on multimetal deposition, optimization studies were conducted. The different parameters of the original formula were tested and the results were evaluated based on the contrast and overall aspect of the enhanced fingermarks. The new formula for SMD was found based on the most optimized parameters. Interestingly, it was found that important variations from the base parameters did not significantly affect the outcome of the enhancement, thus demonstrating that SMD is a very robust technique. Finally, a comparison of the optimized SMD with multi-metal deposition (MMD) was carried out on different surfaces. It was demonstrated that SMD produces comparable results to MMD, thus validating the technique.