250 resultados para ORGANIZATION TEST
Resumo:
BACKGROUND: Baseline physical activity data are needed to effectively plan programs and policies to prevent noncommunicable diseases, but for many African countries these data are lacking. PURPOSE: To describe and compare levels and patterns of physical activity among adults across 22 African countries. METHODS: Data from 57,038 individuals from 22 countries (11 national and 11 subnational samples) that participated in the STEPwise approach to chronic disease risk factor surveillance (2003-2009) were analyzed in 2010. The validated Global Physical Activity Questionnaire (GPAQ) was used to assess days and duration of physical activity at work, for transport, and during leisure time in a typical week. RESULTS: Overall, 83.8% of men and 75.7% of women met WHO physical activity recommendations (at least 150 minutes of moderate activity per week or equivalent). Country prevalence ranged from 46.8% (Mali) to 96.0% (Mozambique). Physical activity, both at work and for transport, including walking, had large contributions to overall physical activity, while physical activity during leisure time was rare in the analyzed countries. CONCLUSIONS: Physical activity levels varied greatly across African countries and population subgroups. Leisure time activity was consistently low. These data will be useful to inform policymakers and to guide interventions to promote physical activity.
Resumo:
Cannula design is of prime importance for venous drainage during cardiopulmonary bypass (CPB). To evaluate cannulas intended for CPB, an in vitro circuit was set up with silicone tubing between the test cannula encased in a movable preload reservoir and another static reservoir. The pressure-drop (DeltaP) value (P-drainage - P-preload) was measured using Millar pressure transducers. Flow rate (Q) was measured using an ultrasound flowmeter. Data display and data recording were controlled using a LabView application, custom made particularly for our experiments. Our results demonstrated that DeltaP, Q, and cannula resistance (DeltaP/Q) values were significantly decreased when the cannula diameter was increased for Smart and Medtronic cannulas. Smartcanula showed 36% and 43% less resistance compared to Medtronic venous and Medtronic femoral cannulas, respectively. The cannula shape (straight- or curved-tips) did not affect the DLP cannula resistance. Out of five cannulas tested, the Smartcanula outperforms the other commercially available cannulas. The mean (DeltaP/Q) values were 3.3 +/- 0.08, 4.07 +/- 0.08, 5.58 +/- 0.10, 5.74 +/- 0.15, and 6.45 +/- 0.15 for Smart, Medtronic, Edwards, Sarns, and Gambro cannulas, respectively (two-way ANOVA, p < 0.0001). In conclusion, the present assay allows discrimination between different forms of cannula with high or low lumen resistance.
Resumo:
Screening for latent tuberculosis infection (LTBI) is recommended prior to organ transplantation. The Quantiferon-TB Gold assay (QFT-G) may be more accurate than the tuberculin skin test (TST) in the detection of LTBI. We prospectively compared the results of QFT-G to TST in patients with chronic liver disease awaiting transplantation. Patients were screened for LTBI with both the QFT-G test and a TST. Concordance between test results and predictors of a discordant result were determined. Of the 153 evaluable patients, 37 (24.2%) had a positive TST and 34 (22.2%) had a positive QFT-G. Overall agreement between tests was 85.1% (kappa= 0.60, p < 0.0001). Discordant test results were seen in 12 TST positive/QFT-G negative patients and in 9 TST negative/QFT-G positive patients. Prior BCG vaccination was not associated with discordant test results. Twelve patients (7.8%), all with a negative TST, had an indeterminate result of the QFT-G and this was more likely in patients with a low lymphocyte count (p = 0.01) and a high MELD score (p = 0.001). In patients awaiting liver transplantation, both the TST and QFT-G were comparable for the diagnosis of LTBI with reasonable concordance between tests. Indeterminate QFT-G result was more likely in those with more advanced liver disease.
Resumo:
In the International Olympic Committee (IOC) accredited laboratories, specific methods have been developed to detect anabolic steroids in athletes' urine. The technique of choice to achieve this is gas-chromatography coupled with mass spectrometry (GC-MS). In order to improve the efficiency of anti-doping programmes, the laboratories have defined new analytical strategies. The final sensitivity of the analytical procedure can be improved by choosing new technologies for use in detection, such as tandem mass spectrometry (MS-MS) or high resolution mass spectrometry (HRMS). A better sample preparation using immuno-affinity chromatography (IAC) is also a good tool for improving sensitivity. These techniques are suitable for the detection of synthetic anabolic steroids whose structure is not found naturally in the human body. The more and more evident use, on a large scale, of substances chemically similar to the endogenous steroids obliges both the laboratory and the sports authorities to use the steroid profile of the athlete in comparison with reference ranges from a population or with intraindividual reference values.
Resumo:
This prospective study applies an extended Information-Motivation-Behavioural Skills (IMB) model to establish predictors of HIV-protection behaviour among HIV-positive men who have sex with men (MSM) during sex with casual partners. Data have been collected from anonymous, self-administered questionnaires and analysed by using descriptive and backward elimination regression analyses. In a sample of 165 HIV-positive MSM, 82 participants between the ages of 23 and 78 (M=46.4, SD=9.0) had sex with casual partners during the three-month period under investigation. About 62% (n=51) have always used a condom when having sex with casual partners. From the original IMB model, only subjective norm predicted condom use. More important predictors that increased condom use were low consumption of psychotropics, high satisfaction with sexuality, numerous changes in sexual behaviour after diagnosis, low social support from friends, alcohol use before sex and habitualised condom use with casual partner(s). The explanatory power of the calculated regression model was 49% (p<0.001). The study reveals the importance of personal and social resources and of routines for condom use, and provides information for the research-based conceptualisation of prevention offers addressing especially people living with HIV ("positive prevention").
Resumo:
Sustained atrial fibrillation (AF) is maintained by sites displaying high dominant frequency (DF). In patients (pts) with long-standing persistent AF (LS-pAF), their spatial distribution and the presence of a left-to-right atrial DF gradient remain poorly known. We hypothesized that the pre-ablation bi-atrial frequency characteristics of LS-pAF pts terminated within the left atrium (LT) are different from that of non terminated (NT) ones. Methods: 23 consecutive pts (59±7y, LS-pAF duration 19±12m) underwent stepwise catheter ablation (step-CA) consisting in pulmonary veins isolation, left atrial (LA) defragmentation, and right atrial (RA) ablations for non terminated AF. A quadripolar catheter (CAT) was placed into the RA appendage (RAA), a decapolar CAT into the coronary sinus (CS) and a duodecapolar CAT into the LA divided into 8 segments. For each segment, 20-sec of bipolar recording was acquired. The DF was defined as the largest peak in the power spectrum (3-15 Hz). The inter-atrial DF gradient was defined as the DF difference between LA and RA appendages. Results: LS-pAF was terminated in 83% (19/23) of the pts: 17 LT, 2 during RA ablation and 4 NT. The figure shows that before ablation bi-atrial DF values of LT pts are significantly lower than that of NT pts for each LA segment as well as for the RAA (p < 0.05). No significant LA-to-RA DF gradient was observed both for LT (0.3±0.5 Hz, p=ns) and NT (0.5±0.03 Hz, p=ns) pts. No significant difference in DF values was observed between LA segments. Conclusions: The lower DF of LT pts is suggestive of a higher organization within both atria compared to NT pts. Our findings suggest that low bi-atrial DF values, but not inter-atrial DF gradient, might be of interest for selecting LS-pAF candidates for sinus rhythm restoration by step-CA.
Resumo:
Protecting native biodiversity against alien invasive species requires powerful methods to anticipate these invasions and to protect native species assumed to be at risk. Here, we describe how species distribution models (SDMs) can be used to identify areas predicted as suitable for rare native species and also predicted as highly susceptible to invasion by alien species, at present and under future climate and land-use scenarios. To assess the condition and dynamics of such conflicts, we developed a combined predictive modelling (CPM) approach, which predicts species distributions by combining two SDMs fitted using subsets of predictors classified as acting at either regional or local scales. We illustrate the CPM approach for an alien invader and a rare species associated to similar habitats in northwest Portugal. Combined models predict a wider variety of potential species responses, providing more informative projections of species distributions and future dynamics than traditional, non-combined models. They also provide more informative insight regarding current and future rare-invasive conflict areas. For our studied species, conflict areas of highest conservation relevance are predicted to decrease over the next decade, supporting previous reports that some invasive species may contract their geographic range and impact due to climate change. More generally, our results highlight the more informative character of the combined approach to address practical issues in conservation and management programs, especially those aimed at mitigating the impact of invasive plants, land-use and climate changes in sensitive regions
Resumo:
This study compares the clientele of a Swiss anonymous test centre with the general population tested. Information was obtained through similar questionnaires submitted to two samples of HIV-tested people aged from 17 to 45 years: the first administered in the context of a general population telephone survey (n = 245) and the second completed during face-to-face interviews of the clientele of an anonymous test centre (n = 250). The test centre sample has higher proportions of younger and single people. Attenders for anonymous testing were more likely to have acquired a new regular partner during the year preceding the interview (48.0% versus 14.4%). These differences remain when controlling for age and gender. Decision to test comes mostly from the respondent's own initiative, but suggestion from a doctor is more frequent in the general population (23.8% versus 0.8%), whereas suggestion from partner or friends is more frequent in the anonymous centre (44.4% versus 3.0%). The anonymous test centre clientele is not different from the general population tested except for the relational situation and origin of decision for testing. The test centre has become a place where the general population finds a response to a situation-specific need for HIV testing.
Resumo:
Rapid diagnostic tests (RDT) are sometimes recommended to improve the home-based management of malaria. The accuracy of an RDT for the detection of clinical malaria and the presence of malarial parasites has recently been evaluated in a high-transmission area of southern Mali. During the same study, the cost-effectiveness of a 'test-and-treat' strategy for the home-based management of malaria (based on an artemisinin-combination therapy) was compared with that of a 'treat-all' strategy. Overall, 301 patients, of all ages, each of whom had been considered a presumptive case of uncomplicated malaria by a village healthworker, were checked with a commercial RDT (Paracheck-Pf). The sensitivity, specificity, and positive and negative predictive values of this test, compared with the results of microscopy and two different definitions of clinical malaria, were then determined. The RDT was found to be 82.9% sensitive (with a 95% confidence interval of 78.0%-87.1%) and 78.9% (63.9%-89.7%) specific compared with the detection of parasites by microscopy. In the detection of clinical malaria, it was 95.2% (91.3%-97.6%) sensitive and 57.4% (48.2%-66.2%) specific compared with a general practitioner's diagnosis of the disease, and 100.0% (94.5%-100.0%) sensitive but only 30.2% (24.8%-36.2%) specific when compared against the fulfillment of the World Health Organization's (2003) research criteria for uncomplicated malaria. Among children aged 0-5 years, the cost of the 'test-and-treat' strategy, per episode, was about twice that of the 'treat-all' (U.S.$1.0. v. U.S.$0.5). In older subjects, however, the two strategies were equally costly (approximately U.S.$2/episode). In conclusion, for children aged 0-5 years in a high-transmission area of sub-Saharan Africa, use of the RDT was not cost-effective compared with the presumptive treatment of malaria with an ACT. In older patients, use of the RDT did not reduce costs. The question remains whether either of the strategies investigated can be made affordable for the affected population.
Resumo:
Neutrality tests in quantitative genetics provide a statistical framework for the detection of selection on polygenic traits in wild populations. However, the existing method based on comparisons of divergence at neutral markers and quantitative traits (Q(st)-F(st)) suffers from several limitations that hinder a clear interpretation of the results with typical empirical designs. In this article, we propose a multivariate extension of this neutrality test based on empirical estimates of the among-populations (D) and within-populations (G) covariance matrices by MANOVA. A simple pattern is expected under neutrality: D = 2F(st)/(1 - F(st))G, so that neutrality implies both proportionality of the two matrices and a specific value of the proportionality coefficient. This pattern is tested using Flury's framework for matrix comparison [common principal-component (CPC) analysis], a well-known tool in G matrix evolution studies. We show the importance of using a Bartlett adjustment of the test for the small sample sizes typically found in empirical studies. We propose a dual test: (i) that the proportionality coefficient is not different from its neutral expectation [2F(st)/(1 - F(st))] and (ii) that the MANOVA estimates of mean square matrices between and among populations are proportional. These two tests combined provide a more stringent test for neutrality than the classic Q(st)-F(st) comparison and avoid several statistical problems. Extensive simulations of realistic empirical designs suggest that these tests correctly detect the expected pattern under neutrality and have enough power to efficiently detect mild to strong selection (homogeneous, heterogeneous, or mixed) when it is occurring on a set of traits. This method also provides a rigorous and quantitative framework for disentangling the effects of different selection regimes and of drift on the evolution of the G matrix. We discuss practical requirements for the proper application of our test in empirical studies and potential extensions.