39 resultados para Mobility and roaming
Resumo:
OBJECTIVES: This study aimed to determine adjustments in spring-mass model characteristics, plantar loading and foot mobility induced by an exhaustive run. DESIGN: Within-participants repeated measures. METHODS: Eleven highly-trained adolescent middle-distance runners ran to exhaustion on a treadmill at a constant velocity corresponding to 95% of velocity associated with VO₂max (17.8 ± 1.4 kmh(-1), time to exhaustion=8.8 ± 3.4 min). Contact time obtained from plantar pressure sensors was used to estimate spring-mass model characteristics, which were recorded (during 30 s) 1 min after the start and prior to exhaustion using pressure insoles. Foot mobility magnitude (a composite measure of vertical and medial-lateral mobility of the midfoot) was measured before and after the run. RESULTS: Mean contact area (foot to ground), contact time, peak vertical ground reaction force, centre of mass vertical displacement and leg compression increased significantly with fatigue, while flight time, leg stiffness and mean pressure decreased. Leg stiffness decreased because leg compression increased to a larger extent than peak vertical ground reaction forces. Step length, step frequency and foot mobility magnitude did not change at exhaustion. CONCLUSIONS: The stride pattern of adolescents when running on a treadmill at high constant velocity deteriorates near exhaustion, as evidenced by impaired leg-spring behaviour (leg stiffness) and altered plantar loading.
Resumo:
Dual mobility cup systems in total hip arthroplasty consist of a metal back with a non-constrained liner, in which a constrained standard head articulates. While superior stability of such implants in comparison with standard total hip replacements is assumed, it is the purpose of this study to outline the biomechanical concept of dual mobility cups and to describe implant survival and dislocation rate based on the series published in the English-speaking and Francophone literature. A growing body of evidence indicates reduced dislocation rates in primary and revision total hip arthroplasty and in selected tumour cases. The limited availability of studies evaluating long-term implant survival and existing concerns with regard to increased wear rates and aseptic loosening, leads to the conclusion that such implants have to be used with prudence, particularly in standard primary hip arthroplasty and in young patients.
Resumo:
We systematically varied conditions of two-dimensional (2D) agarose gel electrophoresis to optimize separation of DNA topoisomers that differ either by the extent of knotting, the extent of catenation or the extent of supercoiling. To this aim we compared electrophoretic behavior of three different families of DNA topoisomers: (i) supercoiled DNA molecules, where supercoiling covered the range extending from covalently closed relaxed up to naturally supercoiled DNA molecules; (ii) postreplicative catenanes with catenation number increasing from 1 to ∼15, where both catenated rings were nicked; (iii) knotted but nicked DNA molecules with a naturally arising spectrum of knots. For better comparison, we studied topoisomer families where each member had the same total molecular mass. For knotted and supercoiled molecules, we analyzed dimeric plasmids whereas catenanes were composed of monomeric forms of the same plasmid. We observed that catenated, knotted and supercoiled families of topoisomers showed different reactions to changes of agarose concentration and voltage during electrophoresis. These differences permitted us to optimize conditions for their separation and shed light on physical characteristics of these different types of DNA topoisomers during electrophoresis.
Resumo:
Migration partnerships (MPs) have become a key instrument in global migration governance. In contrast to traditional unilateral approaches, MPs emphasize a more comprehensive and inclusive tackling of migration issues between countries of origin, transit, and destination. Due to this cooperation-oriented concept, most of the existing studies on MPs neglect power questions within partnerships in line with the official discourse, reflecting a broader trend in the international migration governance literature. Others take an instrumentalist view in analysing the power of partnerships or focus on soft power. Illustrated with the examples of the European Mobility Partnerships (EU MPs) and the Swiss Migration Partnerships (CH MPs), we conduct an analysis based on a concept of productive power drawing on post-structural and post-colonial insights. Our main argument is that in contrast to their seemingly consent-oriented and technical character, MPs are sites of intense (discursive) struggles, and (re-)produce meanings, subjects, and resistances. A productive power analysis allows us to move beyond the dichotomy in the literature between coercion and cooperation, as well as between power and resistance more broadly.
Resumo:
We address the general question of the extent to which the hydrodynamic behaviour of microscopic freely fluctuating objects can be reproduced by macrosopic rigid objects. In particular, we compare the sedimentation speeds of knotted DNA molecules undergoing gel electrophoresis to the sedimentation speeds of rigid stereolithographic models of ideal knots in both water and silicon oil. We find that the sedimentation speeds grow roughly linearly with the average crossing number of the ideal knot configurations, and that the correlation is stronger within classes of knots. This is consistent with previous observations with DNA knots in gel electrophoresis.
Resumo:
La luxation d'une prothèse totale de la hanche est une complication majeure en termes de morbidité pour le patient et des coûts pour le système de santé. Cette complication est retrouvée entre 2 à 3% selon les séries (1-3) pour des prothèses primaires, et beaucoup plus élevée suite à des révisions. Pour remédier à ce problème, des systèmes de prothèses contraintes sont une option, cependant associés à des descellements fréquents entre 10 à 26 % selon les séries (4-6). Ces échecs étant en partie expliqués par une usure rapide des surfaces de frottements due aux fortes contraintes, mais également par les contraintes cupule-os occasionnant des descellements mécaniques (7). Par conséquent, pour augmenter la stabilité, tout en évitant les contraintes sur le couple de frottement, Bousquet développe, en 1976, une prothèse totale de hanche « à double mobilité ». Ce système consiste à combiner deux articulations apparentes, premièrement une tête métallique dans un insert de polyéthylène, articulé lui- même dans la concavité d'une cupule métallique fixée au bassin. En tant que tel, ce système biomécanique réduirait en théorie le risque de luxation. Dès lors, on aperçoit depuis environ 15 ans une augmentation progressive de l'utilisation de ce type d'implants que ce soit comme implant primaire ou secondaire, chez des patients jeunes ou âgés. Cependant, des études in vitro, ont montré que des grandes surfaces de friction sont associées à une augmentation de l'usure du polyéthylène (8). En revanche, les données sur la cinématique et l'usure, in vivo, de ce type d'implant étaient jusqu'alors limitées. Depuis quelques années, un certain nombre d'études cliniques avec un follow up significatif ont été publiées. CONCLUSIONS ET PERSPECTIVES FUTURES La prothèse totale de hanche à double mobilité, développée par Bousquet dans les années 1970, est un concept novateur dans l'arthroplastie totale de hanche. Depuis sa première conception, de nombreuses améliorations ont été adoptées. Cependant, ses effets à long terme sur la survie de l'implant doivent encore être effectué. Certes, des études ont montré un net effet sur la réduction du taux de luxation des prothèses primaires, lors de révision ou après résection tumorale. Toutefois, compte tenu des données limitées à long terme sur le taux d'usure et le descellement aseptique, il convient d'utiliser ce type d'implant avec prudence, en particulier lors d'arthroplastie primaire chez des patients jeunes.