163 resultados para Methicillin-resistant Staphylococcus aureus


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: A hospitalised patient infected with MRSA was found to harbour a VISA strain after 6 weeks of treatment with vancomycin. Additional contact measures were reinforced according to CDCs recommendations. We decide to evaluate if these applied control measures were effective. Objective: To evaluate the efficacy of strict additional contact measures to contain the dissemination of VISA from an infected patient. Methods: All patients from the unit were screened weekly for MRSA during a 6-week period, whereas health care workers (HCW) were screened only once. Screening specimen included nose, throat, groin, and clinical specimens for patients, and only nose and throat for HCW. Broth enrichment and chromogenic agar (MRSA-select) were used for MRSA detection. All MRSA isolates were tested on Van screen plates, and growing colonies were tested for MIC of vancomycin. MIC was performed using Etest. Population analysis was done for VISA confirmation. One strain per person was typed by Double Locus Sequence Typing (based on clfB and spa sequencing). Results: 66 patients hospitalized in the same service during the 6 weeks and 55 HCW were screened for MRSA and VISA. MRSA was found in 16/66 (24%) patients and 1/55 (2%) HCW. 16/17 MRSA from patients belonged to the same genotype that the VISA strain. The remaining patient had a MRSA identical to the HCW isolate. Among the 16 MRSA isolates sharing the same genotype than the VISA strain, two showed Etests vancomycin MIC of only 4 mg/L. MIC results were confirmed by the population analysis. They were not considered as VISA, but as MRSA with increased vancomycin MICs. Both isolates were obtained from two roommates. Conclusion: Strict additional contact measures were found to be effective to contain VISA dissemination. However, the identification of two isolates with increased vancomycin MIC (4 mg/L) in two roommates raised the question of the need to routinely test this susceptibility and of adequate control measures for patients harbouring such isolates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To describe an ongoing outbreak that tripled the annual detection of methicillin-resistant Staphylococcus aureus (MRSA) carriage in a tertiary care hospital. Methods: Active surveillance of MRSA is performed since 20 years in our hospital. Our protocol includes screening of patients transferred from high-incidence health-care institutions or countries, roommates of new MRSA cases, and wards where _2 patients acquired MRSA during the same week. Contact precautions are used for known carriers. PFGE was used for molecular typing until 2004, and was then replaced by Double-Locus Sequence Typing (DLST). Results: A median yearly incidence of 173 new carriers of MRSA was observed from 2002 to 2007. Since September 2008, an increasing number of new cases were observed, mainly as successive clusters limited to distinct wards, reaching a total of 398 until October 2009. The yearly incidence of new cases rose to 275 in 2008 and 613 in 2009. 60% of the cases were due to one strain: DLST 4−4, ST 228, SCCmecI. The incidence of new cases due to the previously predominant strains remained unchanged. The epidemic strain corresponded to a new variant of a clone responsible for a previous outbreak in 2001, and only sporadically isolated (mean of 20 cases/year) since then. A case- control study documented a significant association between acquisition of the epidemic strain and a stay in intensive and intermediary care units, a highest number of internal transfers, but did not identify a point source of transmission. Infection control practices and antibiotic policy had remained unchanged for several years. Compliance with handhygiene as monitored yearly was on the rise. Screening of 313 healthcare workers only found one carrier of the epidemic strain lately in the outbreak. Additional infection control measures were enforced, including screening at ICU admission and discharge with PCR-based rapid test, routine screening for all patients leaving epidemic wards, introduction of PCR-based rapid test for contact tracing, additional working forces for environmental disinfection, and hospital-wide education of healthcare workers. However, the outbreak was still ongoing after 5 months. Conclusions: Factors linked to the dissemination of this new variant in our institution remain undetermined. This unresolved outbreak suggests that this new variant acquired hyperepidemic properties, which calls for further investigations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In vitro and in vivo activity of amoxicillin and penicillin G alone or combined with a penicillinase inhibitor (clavulanate) were tested against five isogenic pairs of methicillin-resistant Staphylococcus aureus (MRSA) producing or not producing penicillinase. Loss of the penicillinase plasmid caused an eight times or greater reduction in the MICs of amoxicillin and penicillin G (from greater than or equal to 64 to 8 micrograms/ml), but not of the penicillinase-resistant drugs methicillin and cloxacillin (greater than or equal to 64 micrograms/ml). This difference in antibacterial effectiveness correlated with a more than 10 times greater penicillin-binding protein 2a affinity of amoxicillin and penicillin G than of methicillin and a greater than or equal to 90% successful amoxicillin treatment of experimental endocarditis due to penicillinase-negative MRSA compared with cloxacillin, which was totally ineffective (P less than .001). Amoxicillin was also effective against penicillinase-producing parent MRSA, provided it was combined with clavulanate. Penicillinase-sensitive beta-lactam antibiotics plus penicillinase inhibitors might offer a rational alternative treatment for MRSA infections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During a 1-year period, 87 methicillin-resistant Staphylococcus aureus isolates were collected from 4 major Cuban hospitals for epidemiological analysis. The majority (86%) were related to the community-associated USA300 clone, whereas the remaining belonged to a new clone ST72-V. Interestingly, no hospital-associated clone was found in these Cuban hospitals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

LB11058 is a new synthetic cephalosporin with good affinity for staphylococcal penicillin-binding protein 2a (PBP2a). LB11058 was tested in vitro and in rats with experimental aortic endocarditis against three methicillin-resistant Staphylococcus aureus (MRSA) strains, one penicillinase-negative strain (strain COL), and two penicillinase-producing strains (COL-Bla+ and P8-Hom). The MICs of LB11058 for the organisms were 1 mg/liter. The MICs of vancomycin and ceftriaxone were 1 and >/=64 mg/liter, respectively. In population analysis profiles, none of the MRSA strains grew at >/=2 mg of LB11058/liter. Rats with endocarditis were treated for 5 days. LB11058 was highly bound to serum proteins in rats (>/=98%). However, binding was saturable above a threshold of 250 mg/liter. Therefore, continuous concentrations of 250 mg/liter in serum were infused to ensure a free fraction (>/=5 mg/liter) above the drug's MIC for the entire infusion period. Control treatments included simulation of human serum kinetics produced by intravenous vancomycin (1 g twice daily, free drug concentration above MIC, >/=90% of infusion period) or ceftriaxone (2 g/24 h, free drug concentrations above the MIC, 0% of infusion period). LB11058 successfully treated 10 of 10 (100%) and 13 of 14 (93%) of rats infected with COL-Bla+ and P8-Hom, respectively. This was comparable to vancomycin (sterilization of 8 of 12 [66%] and 6 of 8 [75%] rats, respectively). Ceftriaxone was inactive. Low concentrations of LB11058 (5 and 10 mg/liter, continuously infused) in serum were ineffective, as predicted by the pharmacodynamic parameters. At appropriate doses, LB11058 was highly effective both in vitro and in vivo. This finding supports the development of this beta-lactam with high PBP2a affinity for the treatment of MRSA infections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Methicillin-resistant Staphylococcus aureus (MRSA) is a major cause of both hospital- and community-acquired infections worldwide. However, data about the molecular epidemiology of MRSA in North Africa are still scarce. METHODOLOGY: All MRSA isolates recovered between January 2006 and July 2011 from one Algerian hospital were genetically and phenotypically characterized. RESULTS: The predominance of a European community-associated-MRSA (CA-MRSA) clone (ST80-SCCmec IV-PVL positive) was revealed by this analysis. CONCLUSION: Our data suggest that a CA-MRSA clone recently invaded the hospital setting in Algiers and replaced a typical hospital-associated pandemic clone such as the Brazilian clone (ST239-SCCmec IIImercury-PVL negative).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have compared the phylogenetic diversity of methicillin-resistant Staphylococcus aureus (MRSA) strains from Switzerland and their phylogenetic relationships with European epidemic clones, using multiprimer random amplification polymorphic DNA (RAPD). Strains included 24 European epidemic clones (59 strains), 66 sporadic strains isolated in Switzerland in 1996-1997, and 15 reference strains of five other Staphylococcus species. Similarity and clustering analysis with the Jaccard's coefficient showed that the maximum genetic distance between MRSA strains was 0.43, whereas the minimum genetic distance between the six Staphylococcus species was 0.97, indicating that the method permits phylogenetic hierarchization. The 24 MRSA clones reported to be epidemic in European countries during the 1990s were distributed into seven different genetic clusters with a maximum distance of 0.29 among them. This clustering pattern was confirmed by the analysis of a subset of MRSA strains by multilocus enzyme electrophoresis at 12 loci. Most of the sporadic Swiss strains were distributed into these seven different genetic clusters, together with the epidemic MRSA clones. This suggests that there is no phylogenetic cluster specific to epidemic clones of MRSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

UNLABELLED: Whole-genome sequencing (WGS) of 228 isolates was used to elucidate the origin and dynamics of a long-term outbreak of methicillin-resistant Staphylococcus aureus (MRSA) sequence type 228 (ST228) SCCmec I that involved 1,600 patients in a tertiary care hospital between 2008 and 2012. Combining of the sequence data with detailed metadata on patient admission and movement confirmed that the outbreak was due to the transmission of a single clonal variant of ST228, rather than repeated introductions of this clone into the hospital. We note that this clone is significantly more frequently recovered from groin and rectal swabs than other clones (P < 0.0001) and is also significantly more transmissible between roommates (P < 0.01). Unrecognized MRSA carriers, together with movements of patients within the hospital, also seem to have played a major role. These atypical colonization and transmission dynamics can help explain how the outbreak was maintained over the long term. This "stealthy" asymptomatic colonization of the gut, combined with heightened transmissibility (potentially reflecting a role for environmental reservoirs), means the dynamics of this outbreak share some properties with enteric pathogens such as vancomycin-resistant enterococci or Clostridium difficile. IMPORTANCE: Using whole-genome sequencing, we showed that a large and prolonged outbreak of methicillin-resistant Staphylococcus aureus was due to the clonal spread of a specific strain with genetic elements adapted to the hospital environment. Unrecognized MRSA carriers, the movement of patients within the hospital, and the low detection with clinical specimens were also factors that played a role in this occurrence. The atypical colonization of the gut means the dynamics of this outbreak may share some properties with enteric pathogens.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Y-688 is a new fluoroquinolone with increased activity against ciprofloxacin-resistant staphylococci. The MICs of Y-688 and other quinolones were determined for 58 isolates of ciprofloxacin-resistant and methicillin-resistant Staphylococcus aureus (MRSA). The MICs at which 50% and 90% of bacteria were inhibited were &gt;/=128 and &gt;/=128 mg/liter, respectively, for ciprofloxacin, 16 and 32 mg/liter, respectively, for sparfloxacin, and 0.25 and 1 mg/liter, respectively, for Y-688. This new quinolone was further tested in rats with experimental endocarditis due to either of two isolates of ciprofloxacin-resistant MRSA (namely, P8/128 and CR1). Infected animals were treated for 3 days with ciprofloxacin, vancomycin, or Y-688. Antibiotics were administered through a computerized pump to simulate human-like pharmacokinetics in the serum of rats. The anticipated peak and trough levels of Y-688 were 4 and 1 mg/liter at 0.5 and 12 h, respectively. Treatment with ciprofloxacin was ineffective. Vancomycin significantly decreased vegetation bacterial counts for both organisms (P less, similar 0.05). In contrast, Y-688 only marginally decreased vegetation bacterial counts (P greater, similar 0.05). Moreover, several vegetation that failed Y-688 treatment grew staphylococci for which the MICs of the test antibiotic were increased two to eight times. Y-688 also selected for resistance in vitro, and isolates for which the MICs were increased eight times emerged at a frequency of ca. 10(-8). Thus, in spite of its low MIC for ciprofloxacin-resistant MRSA, Y-688 failed in vivo and its use carried the risk of resistance selection. The fact that ciprofloxacin-resistant staphylococci became rapidly resistant to this potent new drug suggests that the treatment of ciprofloxacin-resistant MRSA with new quinolones might be more problematic than expected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Methicillin-resistant Staphylococcus aureus (MRSA) is a major cause of nosocomial infections worldwide. To differentiate reliably among S. aureus isolates, we recently developed double locus sequence typing (DLST) based on the analysis of partial sequences of clfB and spa genes. In the present study, we evaluated the usefulness of DLST for epidemiological investigations of MRSA by routinely typing 1242 strains isolated in Western Switzerland. Additionally, particular local and international collections were typed by pulsed field gel electrophoresis (PFGE) and DLST to check the compatibility of DLST with the results obtained by PFGE, and for international comparisons. Using DLST, we identified the major MRSA clones of Western Switzerland, and demonstrated the close relationship between local and international clones. The congruence of 88% between the major PFGE and DLST clones indicated that our results obtained by DLST were compatible with earlier results obtained by PFGE. DLST could thus easily be incorporated in a routine surveillance procedure. In addition, the unambiguous definition of DLST types makes this method more suitable than PFGE for long-term epidemiological surveillance. Finally, the comparison of the results obtained by DLST, multilocus sequence typing, PFGE, Staphylococcal cassette chromosome mec typing and the detection of Panton-Valentine leukocidin genes indicated that no typing scheme should be used on its own. It is only the combination of data from different methods that gives the best chance of describing precisely the epidemiology and phylogeny of MRSA.