86 resultados para Mechanical vibration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the advent of new technologies, experience with long-term mechanical circulatory support (MCS) is rapidly growing. Candidates to MCS are selected based on concepts, strategies and classifications that are specific to this indication. As results drastically improve, supported by stronger scientific evidence, the trend is towards earlier implantation. An adequate pre-implant follow-up is mandatory in order to avoid missing the best window of opportunity for implantation. While on chronic support, the hemodynamic profile of patients with continuous-flow ventricular assist devices is unique and remarkably influenced by the hydration status. Optimal management of these patients from the pre-implant phase to the long-term support phase requires a multidisciplinary approach that is similar to that already long validated for organ transplantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the influence of nursing on the duration of weaning from mechanical ventilation in patients with chronic obstructive pulmonary disease. DESIGN: Data were collected prospectively over a 1-yr period (study year) and compared with previously collected prospective data recorded in our chronic obstructive pulmonary disease database during a 5-yr period. SETTING: The medical intensive care unit (ICU) of a university hospital. PATIENTS: Eighty-seven patients with chronic obstructive pulmonary disease. Fifteen patients had chronic obstructive pulmonary disease that required mechanical ventilation for acute exacerbation of their disease (study year), and 72 were patients with chronic obstructive pulmonary disease from the previously collected data. INTERVENTIONS: The ICU course (duration of mechanical ventilation, mortality) was recorded, as well as several respiratory parameters (pulmonary function tests and arterial blood gases in stable conditions, and nutritional status), and they were compared with an "index of nursing." MEASUREMENTS AND MAIN RESULTS: We developed an "index of nursing", comparing the effective workforce of the nurses (number and qualifications) with the ideal workforce required by the number of patients and the severity of their diseases. A value of 1.0 represented a perfect match between the needed and the effectively present nurses, whereas a lesser value signified a diminished available workforce. This index was compared with the complications and duration of weaning from mechanical ventilation. During the first 5 yrs, the duration of mechanical ventilation increased progressively from 7.3 +/- 8.0 to 38.2 +/- 25.8 days (p = .006). A significant inverse correlation between the duration of mechanical ventilation and the nursing index (p = .025) was found. In the sixth comparative year, the number of nurses increased (nursing index = 1.05) and the duration of mechanical ventilation decreased to 9.9 +/- 13 days (p < .001, yr 5 vs. yr 6). CONCLUSIONS: The quality of nursing appears to be a measurable and critical factor in the weaning from mechanical ventilation of patients with chronic obstructive pulmonary disease. Below a threshold in the available workforce of ICU nurses, the weaning duration of patients with chronic obstructive pulmonary disease increases dramatically. Therefore, very close attention should be given to the education and number of ICU nurses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: In vitro mechanical injury of articular cartilage is useful to identify events associated with development of post-traumatic osteoarthritis (OA). To date, many in vitro injury models have used animal cartilage despite the greater clinical relevance of human cartilage. We aimed to characterize a new in vitro injury model using elderly human femoral head cartilage and compare its behavior to that of an existing model with adult bovine humeral head cartilage. DESIGN: Mechanical properties of human and bovine cartilage disks were characterized by elastic modulus and hydraulic permeability in radially confined axial compression, and by Young's modulus, Poisson's ratio, and direction-dependent radial strain in unconfined compression. Biochemical composition was assessed in terms of tissue water, solid, and glycosaminoglycan (GAG) contents. Responses to mechanical injury were assessed by observation of macroscopic superficial tissue cracks and histological measurements of cell viability following single injurious ramp loads at 7 or 70%/s strain rate to 3 or 14 MPa peak stress. RESULTS: Confined compression moduli and Young's moduli were greater in elderly human femoral cartilage vs adult bovine humeral cartilage whereas hydraulic permeability was less. Radial deformations of axially compressed explant disks were more anisotropic (direction-dependent) for the human cartilage. In both cartilage sources, tissue cracking and associated cell death during injurious loading was common for 14 MPa peak stress at both strain rates. CONCLUSION: Despite differences in mechanical properties, acute damage induced by injurious loading was similar in both elderly human femoral cartilage and adult bovine humeral cartilage, supporting the clinical relevance of animal-based cartilage injury models. However, inherent structural differences such as cell density may influence subsequent cell-mediated responses to injurious loading and affect the development of OA.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Whole-body vibration (WBV) exercise is progressively adopted as an alternative therapeutic modality for enhancing muscle force and muscle activity via neurogenic potentiation. So far, possible changes in the recruitment patterns of the trunk musculature after WBV remain undetermined. The main objective of this study was to evaluate the short-term effects of a single WBV session on trunk neuromuscular responses in patients with chronic low back pain (cLBP) and healthy participants. METHODS: Twenty patients with cLBP and 21 healthy participants performed 10 trunk flexion-extensions before and after a single WBV session consisting of five 1-minute vibration sets. Surface electromyography (EMG) of erector spinae at L2-L3 and L4-L5 and lumbopelvic kinematic variables were collected during the trials. Data were analyzed using 2-way mixed analysis of variance models. RESULTS: The WBV session led to increased lumbar EMG activity during the flexion and extension phases but yielded no change in the quiet standing and fully flexed phases. Kinematic data showed a decreased contribution to the movement of the lumbar region in the second extension quartile. These effects were not different between patients with cLBP and healthy participants. CONCLUSIONS: Increased lumbar EMG activity after a single WBV session most probably results from potentiation effects of WBV on lumbar muscles reflex responses. Decreased EMG activity in full trunk flexion, usually observed in healthy individuals, was still present after WBV, suggesting that the ability of the spine stabilizing mechanisms to transfer the extension torque from muscles to passive structures was not affected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to examine the magnitude and the origin of neuromuscular fatigue induced by half-squat static whole-body vibration (WBV) exercise, and to compare it to a non-WBV condition. Nine healthy volunteers completed two fatiguing protocols (WBV and non-WBV, randomly presented) consisting of five 1-min bouts of static half-squat exercise with a load corresponding to 50 % of their individual body mass. Neuromuscular fatigue of knee and ankle muscles was investigated before and immediately after each fatiguing protocol. The main outcomes were maximal voluntary contraction (MVC) torque, voluntary activation, and doublet peak torque. Knee extensor MVC torque decreased significantly (P < 0.01) and to the same extent after WBV (-23 %) and non-WBV (-25 %), while knee flexor, plantar flexor, and dorsiflexor MVC torque was not affected by the treatments. Voluntary activation of knee extensor and plantar flexor muscles was unaffected by the two fatiguing protocols. Doublet peak torque decreased significantly and to a similar extent following WBV and non-WBV exercise, for both knee extensors (-25 %; P < 0.01) and plantar flexors (-7 %; P < 0.05). WBV exercise with additional load did not accentuate fatigue and did not change its causative factors compared to non-WBV half-squat resistive exercise in recreationally active subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: To evaluate outcomes after optimized laser in situ keratomileusis (LASIK) for astigmatism correction with flap created by a mechanical microkeratome or a femtosecond laser. Patients and Methods: In this retrospective study, a total of 102 eyes of 71 consecutive patients were enrolled undergoing optimized LASIK treatments using the Allegretto laser system (WaveLight Laser Technologie AG, Erlangen, Germany). A mechanical microkeratome for flap creation was used (One Use, Moria®) in 46 eyes (31 patients, spherical equivalent [SE] -4.44 D ± 2.4) and a femtosecond laser was used (LDV, Ziemer®) in 56 eyes (40 patients, spherical equivalent [SE] -3.07 D ± 3.3). The two groups were matched for inclusion criteria and were operated under similar conditions by the same surgeon. Results: Overall, the preoperative spherical equivalent was -9.5 diopters (D) to +3.37 D; the preoperative manifest astigmatism was between -1.5 D and -3.5 D. At 6 months postoperatively, the mean postoperative uncorrected distance visual acuity (UDVA) was 0.93 ± 0.17 (range 0.4 to 1.2) in the Moria group and 1.0 ± 0.21 (range 0.6 to 1.6) in the Femto group, which was statistically significant (p = 0.003). Comparing the cylinder power there was a statistical difference between the two groups (p = 0.0015). Conclusions: This study shows that the method of flap creation has a significant impact on postoperative astigmatism with a significantly better postoperative UDVA in the Femto group. These findings suggest that the femtosecond laser provides a better platform for LASIK treatment of astigmatism than the commonly used microkeratome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mortality of the acute respiratory distress syndrome (ARDS) remains extremely high and only few evidence-based specific treatments are currently available. Protective mechanical ventilation has emerged as the comer stone of the management of ARDS to avoid the occurrence of ventilation-induced lung injuries (VILI). Mechanical ventilation in the prone position has often been considered as a rescue therapy reserved to refractory hypoxemia. Since the publication of the PROSEVA study in 2013, early prone positioning for mechanical ventilation should be recommended to improve survival of patients with severe ARDS. In this article, both the theoretical and practical aspects of mechanical ventilation in prone position are reviewed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND/AIM: Excitation-contraction coupling is modulated by nitric oxide (NO) which otherwise has either beneficial or detrimental effects on myocardial function during hypoxia-reoxygenation. This work aimed at characterizing the variations of electromechanical delay (EMD) induced by anoxia-reoxygenation within the developing heart and determining whether atrial and ventricular EMD are modulated by NO to the same extent. METHODS: Hearts of 4 or 4.5-day-old chick embryos were excised and submitted in vitro to normoxia (45 min), anoxia (30 min) and reoxygenation (60 min). Electrocardiogram and atrial and ventricular contractions were simultaneously recorded throughout experiment. Anoxia-reoxygenation-induced chrono-, dromo-and inotropic disturbances and changes in EMD in atrium (EMDa) and ventricle (EMDv) were investigated in control hearts and in hearts exposed to 0.1, 1, 10, 50 and 100 microM of DETA-NONOate (a NO donating agent) or to 50 microM of L-NAME (a NOS inhibitor). RESULTS: Under normoxia, heart rate, PR interval, ventricular shortening velocity, EMDa and EMDv were similar in control, L-NAME-treated and DETA-NONOate-treated hearts. Under anoxia, cardiac activity became markedly erratic within less than 10 min in all groups. At the onset of reoxygenation, EMDv was increased by about 300% with respect to the preanoxic value while EMDa did not vary significatively. Compared to control conditions, L-NAME or DETA-NONOate had no influence on the negative chrono-, dromo- and inotropic effects induced by anoxia-reoxygenation. However, L-NAME prolonged EMDv during anoxia and delayed EMDv recovery during reoxygenation while 100 microM DETA-NONOate had the opposite effects. EMDa was neither affected by NOS inhibitor nor NO donor. At the end of reoxygenation, all the investigated parameters returned to their basal values. CONCLUSION: This work provides evidence that a NO-dependent pathway is involved in regulation of the ventricular excitation-contraction coupling in the anoxic-reoxygenated developing heart.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The net mechanical efficiency of positive work (eta(pos)) has been shown to increase if it is immediately preceded by negative work. This phenomenon is explained by the storage of elastic energy during the negative phase and its release during the subsequent positive phase. If a transition time (T) takes place, the elastic energy is dissipated into heat. The aim of the present study was to investigate the relationship between eta(pos) and T, and to determine the minimal T required so that eta(pos) reached its minimal value. Seven healthy male subjects were tested during four series of lowering-raising of the body mass. In the first series (S (0)), the negative and positive phases were executed without any transition time. In the three other series, T was varied by a timer (0.12, 0.24 and 0.56 s for series S (1), S (2) and S (3), respectively). These exercises were performed on a force platform sensitive to vertical forces to measure the mechanical work and a gas analyser was used to determine the energy expenditure. The results indicated that eta(pos) was the highest (31.1%) for the series without any transition time (S (0)). The efficiencies observed with transition times (S (1), S (2) and S (3)) were 27.7, 26.0 and 23.8%, respectively, demonstrating that T plays an important role for mechanical efficiency. The investigation of the relationship between eta(pos) and T revealed that the minimal T required so that eta(pos) reached its minimal value is 0.59 s.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The case of a man exposed during 25 years to vibration while maneuvering a heavy earth moving tractor is reported. The first clinical manifestation of hand-arm vibration syndrome was a bilateral Raynaud's phenomenon followed five years later by digital necrosis. The arteriography revealed a proximal and bilateral ulnar artery occlusion. Bilateral median nerve conduction abnormalities were also present. Vibration exposure level was much higher than the threshold level proposed by the European Commission. Laboratory examinations for vasculitis and other vascular diseases were all negative. The purpose of this report is to show that vibration can be responsible for proximal occlusion of a medium sized artery and severe neurovascular abnormalities which must be distinguished from the usual vasospastic Raynaud's phenomenon and the classical hypothenar hammer syndrome. An early and correct diagnosis is crucial because continued repetitive trauma can result in irreversible ischemic injury and loss of digits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peripheral inflammation induces persistent central sensitization characterized by mechanical allodynia and heat hyperalgesia that are mediated by distinct mechanisms. Compared to well-demonstrated mechanisms of heat hyperalgesia, mechanisms underlying the development of mechanical allodynia and contralateral pain are incompletely known. In this study, we investigated the distinct role of spinal JNK in heat hyperalgesia, mechanical allodynia, and contralateral pain in an inflammatory pain model. Intraplantar injection of complete Freund's adjuvant (CFA) induced bilateral mechanical allodynia but unilateral heat hyperalgesia. CFA also induced a bilateral activation (phosphorylation) of JNK in the spinal cord, and the phospho JNK1 (pJNK1) levels were much higher than that of pJNK2. Notably, both pJNK and JNK1 were expressed in GFAP-positive astrocytes. Intrathecal infusion of a selective peptide inhibitor of JNK, D-JNKI-1, starting before inflammation via an osmotic pump, reduced CFA-induced mechanical allodynia in the maintenance phase but had no effect on CFA-induced heat hyperalgesia. A bolus intrathecal injection of D-JNKI-1 or SP600126, a small molecule inhibitor of JNK also reversed mechanical allodynia bilaterally. In contrast, peripheral (intraplantar) administration of D-JNKI-1 reduced the induction of CFA-induced heat hyperalgesia but did not change mechanical allodynia. Finally, CFA-induced bilateral mechanical allodynia was attenuated in mice lacking JNK1 but not JNK2. Taken together, our data suggest that spinal JNK, in particular JNK1 plays an important role in the maintenance of persistent inflammatory pain. Our findings also reveal a unique role of JNK1 and astrocyte network in regulating tactile allodynia and contralateral pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STUDY OBJECTIVE: To evaluate the safety of a combined heat and moisture exchanger filter (HMEF) for the conditioning of inspired gas in long-term mechanical ventilation (MV). DESIGN: Randomized controlled trial. SETTING: Medical ICU in a large teaching hospital. PATIENTS: One hundred fifteen consecutive patients who required > or = 48 h of MV. INTERVENTIONS: Patients were randomized at intubation time (day 1) to receive inspired gas conditioned either by a water-bath humidifier heated at 32 degrees C (HWBH) or by an HMEF (Hygroster; DAR; Mirandola, Italy). MEASUREMENTS AND MAIN RESULTS: The two study groups were comparable in terms of primary pathologic condition at the time of hospital admission, disease severity as measured by the Simplified Acute Physiology Score, and ICU mortality. They did not differ with respect to ventilator days per patient (mean +/- SD: HMEF, 7.6 +/- 6.5; HWBH, 7.8 +/- 5.8), incidence of endotracheal tube obstruction (HMEF, 0/59; HWBH, 1/56), and incidence of hypothermic episodes (HMEF, five; HWBH, two). In 41 patients receiving MV for > or = 5 days, the morphologic integrity of respiratory epithelium was evaluated on day 1 and day 5, using a cytologic examination of tracheal aspirate smears. The state of ciliated epithelium was scored on a scale from 0 (poorest integrity) to 1,200 (maximum integrity), according to a well-described method. In both patient groups, the scores slightly but significantly decreased from day 1 to day 5 (mean +/- SD: HWBH, from 787 +/- 104 to 745 +/- 88; HMEF, from 813 +/- 79 to 739 +/- 62; p < 0.01 for both groups); there were no statistically significant differences between groups. CONCLUSIONS: These data indicate acceptable safety of HMEFs of the type used in the present study for long-term mechanical ventilation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whole-body vibration (WBV) is a new exercise method, with good acceptance among sedentary subjects. The metabolic response to WBV has not been well documented. Three groups of male subjects, inactive (SED), endurance (END) and strength trained (SPRINT) underwent a session of side-alternating WBV composed of three 3-min exercises (isometric half-squat, dynamic squat, dynamic squat with added load), and repeated at three frequencies (20, 26 and 32 Hz). VO(2), heart rate and Borg scale were monitored. Twenty-seven healthy young subjects (10 SED, 8 SPRINT and 9 END) were included. When expressed in % of their maximal value recorded in a treadmill test, both the peak oxygen consumption (VO(2)) and heart rate (HR) attained during WBV were greatest in the SED, compared to the other two groups (VO(2): 59.3 % in SED vs 50.8 % in SPRINT and 48.0 % in END, p<0.01; HR 82.7 % in SED vs 80.4 % in SPRINT and 72.4 % in END, p<0.05). In conclusions, the heart rate and metabolic response to WBV differs according to fitness level and type, exercise type and vibration frequency. In SED, WBV can elicit sufficient cardiovascular response to benefit overall fitness and thus be a potentially useful modality for the reduction of cardiovascular risk.