68 resultados para MICROVOLTAMMETRIC ELECTRODES


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To study delayed failure after subthalamic nucleus (STN) deep brain stimulation in Parkinson's disease (PD) patients. METHODS: Out of 56 consecutive bilaterally STN-implanted PD patients, we selected subjects who, after initial clinical improvement (1 month after surgery), lost benefit (delayed failure, DF). RESULTS: Five patients developed sub-acutely severe gait disorders (DF). In 4/5 DF patients, a micro-lesion effect, defined as improvement without stimulation, was observed; immediate post-operative MRI demonstrated electrode located above or behind to the STN. CONCLUSIONS: Patients presenting micro-lesion effect should be carefully monitored, as this phenomenon can mask electrodes misplacement and evolution in DF

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to evaluate the efficiency and the effects of changes in parameters of chronic amygdala-hippocampal deep brain stimulation (AH-DBS) in mesial temporal lobe epilepsy (TLE). Eight pharmacoresistant patients, not candidates for ablative surgery, received chronic AH-DBS (130 Hz, follow-up 12-24 months): two patients with hippocampal sclerosis (HS) and six patients with non-lesional mesial TLE (NLES). The effects of stepwise increases in intensity (0-Off to 2 V) and stimulation configuration (quadripolar and bipolar), on seizure frequency and neuropsychological performance were studied. The two HS patients obtained a significant decrease (65-75%) in seizure frequency with high voltage bipolar DBS (≥1 V) or with quadripolar stimulation. Two out of six NLES patients became seizure-free, one of them without stimulation, suggesting a microlesional effect. Two NLES patients experienced reductions of seizure frequency (65-70%), whereas the remaining two showed no significant seizure reduction. Neuropsychological evaluations showed reversible memory impairments in two patients under strong stimulation only. AH-DBS showed long-term efficiency in most of the TLE patients. It is a valuable treatment option for patients who suffer from drug resistant epilepsy and who are not candidates for resective surgery. The effects of changes in the stimulation parameters suggest that a large zone of stimulation would be required in HS patients, while a limited zone of stimulation or even a microlesional effect could be sufficient in NLES patients, for whom the importance of the proximity of the electrode to the epileptogenic zone remains to be studied. Further studies are required to ascertain these latter observations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wounded leaves communicate their damage status to one another through a poorly understood process of long-distance signalling. This stimulates the distal production of jasmonates, potent regulators of defence responses. Using non-invasive electrodes we mapped surface potential changes in Arabidopsis thaliana after wounding leaf eight and found that membrane depolarizations correlated with jasmonate signalling domains in undamaged leaves. Furthermore, current injection elicited jasmonoyl-isoleucine accumulation, resulting in a transcriptome enriched in RNAs encoding key jasmonate signalling regulators. From among 34 screened membrane protein mutant lines, mutations in several clade 3 GLUTAMATE RECEPTOR-LIKE genes (GLRs 3.2, 3.3 and 3.6) attenuated wound-induced surface potential changes. Jasmonate-response gene expression in leaves distal to wounds was reduced in a glr3.3 glr3.6 double mutant. This work provides a genetic basis for investigating mechanisms of long-distance wound signalling in plants and indicates that plant genes related to those important for synaptic activity in animals function in organ-to-organ wound signalling.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Selection of action may rely on external guidance or be motivated internally, engaging partially distinct cerebral networks. With age, there is an increased allocation of sensorimotor processing resources, accompanied by a reduced differentiation between the two networks of action selection. The present study examines the age effects on the motor-related oscillatory patterns related to the preparation of externally and internally guided movements. Thirty-two older and 30 younger adults underwent three delayed motor tasks with S1 as preparatory and S2 as imperative cue: Full, laterality instructed by S1 (external guidance); Free, laterality freely selected (internal guidance); None, laterality instructed by S2 (no preparation). Electroencephalogram (EEG) was recorded using 64 surface electrodes. Motor-Related Amplitude Asymmetries (MRAA), indexing the lateralization of oscillatory activities, were analyzed within the S1-S2 interval in the mu (9-12 Hz) and low beta (15-20 Hz) motor-related frequency bands. Reaction times to S2 were slower in older than younger subjects, and slower in the Free than in the Full condition in older subjects only. In the Full condition, there were significant mu MRAA in both age groups, and significant low beta MRAA only in older adults. The Free condition was associated with large mu MRAA in younger adults and limited low beta MRAA in older adults. In younger subjects, the lateralization of mu activity in both Full and Free conditions indicated effective external and internal motor preparation. In older subjects, external motor preparation was associated with lateralization of low beta in addition with mu activity, compatible with an increase of motor-related resources. In contrast, absence of mu and limited low beta lateralization in internal motor preparation was concomitant with reaction time slowing and suggested less efficient cerebral processes subtending free movement selection in older adults, indicating reduced capacity for internally driven action with age.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Human decision-making has consistently demonstrated deviation from "pure" rationality. Emotions are a primary driver of human actions and the current study investigates how perceived emotions and personality traits may affect decision-making during the Ultimatum Game (UG). We manipulated emotions by showing images with emotional connotation while participants decided how to split money with a second player. Event-related potentials (ERPs) from scalp electrodes were recorded during the whole decision-making process. We observed significant differences in the activity of central and frontal areas when participants offered money with respect to when they accepted or rejected an offer. We found that participants were more likely to offer a higher amount of money when making their decision in association with negative emotions. Furthermore, participants were more likely to accept offers when making their decision in association with positive emotions. Honest, conscientious, and introverted participants were more likely to accept offers. Our results suggest that factors others than a rational strategy may predict economic decision-making in the UG.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neural signatures of humans' movement intention can be exploited by future neuroprosthesis. We propose a method for detecting self-paced upper limb movement intention from brain signals acquired with both invasive and noninvasive methods. In the first study with scalp electroencephalograph (EEG) signals from healthy controls, we report single trial detection of movement intention using movement related potentials (MRPs) in a frequency range between 0.1 to 1 Hz. Movement intention can be detected above chance level (p<0.05) on average 460 ms before the movement onset with low detection rate during the on-movement intention period. Using intracranial EEG (iEEG) from one epileptic subject, we detect movement intention as early as 1500 ms before movement onset with accuracy above 90% using electrodes implanted in the bilateral supplementary motor area (SMA). The coherent results obtained with non-invasive and invasive method and its generalization capabilities across different days of recording, strengthened the theory that self-paced movement intention can be detected before movement initiation for the advancement in robot-assisted neurorehabilitation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: EEG is the cornerstone of epilepsy diagnostics and mandatory to determine the underlying epilepsy syndrome (e.g. focal vs idiopathic generalized). However, its potential as imaging tool is still underrecognized. In the present study, we aim to determine the prerequisites of maximal benefit of electric source imaging (ESI) to localize the irritative zone in patients with focal epilepsy. Methods: 150 patients suffering from focal epilepsy and with minimum 1 year post-operative follow-up were studied prospectively by reviewers blinded to the underlying diagnosis and outcome. We evaluated the influence of two important factors on sensitivity and specificity of ESI: the number of electrodes (low resolution, LR-ESI: \30 vs. high resolution, HR-ESI: 128-256 electrodes), and the use of individual MRI (i-MRI) vs. template MRI (t-MRI) as head model.Results: ESI had a sensitivity of 85% and a specificity of 87% when HR-ESI with i-MRI was used. Using LR-ESI, sensitivity decreased to 68%, or even 57% when only t-MRI was available. The sensitivity of HR-ESI/i-MRI compared favorably with those of MRI (76%), PET (69%) and ictal/interictal SPECT (64%).Interpretation: This study on a large patient group shows excellent sensitivity and specificity of ESI if 128 EEG channels or more are used for ESI and if the results are co-registered to the patient's individual MRI. Localization precision is as high as or even higher than established brain imaging techniques, providing excellent costeffectiveness in epilepsy evaluation. HR-ESI appears to be a valuable additional imaging tool, given that larger electrode arrays are easily and rapidly applied with modern EEG equipment and that structural MRI is nearly always available for these patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We evaluated a new combined sensor for monitoring transcutaneous carbon dioxide tension (PtcCO2) and oxygen tension (PtcO2) in 20 critically ill newborn infants. Arterial oxygen tension (PaO2) ranged from 16 to 126 torr and arterial carbon dioxide tension (PaCO2) from 14 to 72 torr. Linear correlation analysis (100 paired values) of PtcO2 versus PaO2 showed an r value of 0.75 with a regression equation of PtcO2 = 8.59 + 0.905 (PaO2), while PtcCO2 versus PaCO2 revealed a correlation coefficient of r = 0.89 with an equation of PtcCO2 = 2.53 + 1.06 (PaCO2). The bias between PaO2 and PtcO2 was -2.8 with a precision of +/- 16.0 torr (range, -87 to +48 torr). The bias between PaCO2 and PtcCO2 was -5.1 with a precision of +/- 7.3 torr (range, -34 to +8 torr). The transcutaneous sensor detected 83% of hypoxia (PaO2 less than 45 torr), 75% of hyperoxia (PaO2 greater than 90 torr), 45% of hypocapnia (PaCO2 less than 35 torr), and 96% of hypercapnia (PaCO2 greater than 45 torr). We conclude that the reliability of the combined transcutaneous PO2 and PCO2 monitor in sick neonates is good for detecting hypercapnia, fair for hypoxia and hyperoxia, but poor for hypocapnia. It is an improvement in that it spares available skin surface and requires less handling, but it appears to be slightly less accurate than the single electrodes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACT High frequency electrical deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a worldwide recognized therapy for the motor symptoms of Parkinson's disease in fluctuating patients who are progressively disabled despite medical treatment adjustments. However, such improvements emerge despite a lack of understanding of either the precise role of STN in human motor control or the mechanism(s) of action of DBS. Through the question "are we where we think we are", this thesis is first dedicated to the control of the position of the preoperatively defined target and of the implanted electrodes on magnetic resonance imaging (MRI). This anatomical approach will provide a way to identify more precisely the structure(s) involved by electrical stimulation. Then, a study of the correlation existing between the position of the preoperative target and the position of the electrode is performed. In this part, a unique opportunity is given to identify factors that may affect these correlation results. Finally, the whole work represents a « quality assessment » of the crucial steps of STN DBS: first, the target and the implanted electrode localisation procedures that have been developed in collaboration with the Radiological department; second the implantation procedure that has been performed nowadays on more than 50 parkinsonian patients in the Neurosurgical department of the Centre Hospitalier Universitaire Vaudois in collaboration with the Neurological department. This work is especially addressed to the multidisciplinary medical team involved in the surgical treatment of movement disorders, including also neurophysiologists, neuropsychologists and psychiatrists. RESUME La stimulation électrique à haute fréquence du noyau sous-thalamique est à ce jour mondialement reconnue pour le traitement des symptômes moteurs de la maladie de Parkinson chez des patients sévèrement atteints et chez qui la réponse fluctuante au traitement médicamenteux ne peut être améliorée de façon satisfaisante. Cependant, les résultats observés surviennent malgré une compréhension approximative et controversée du rôle réel du noyau sous-thalamique dans le contrôle du mouvement volontaire aussi bien que des mécanismes d'action de la stimulation cérébrale profonde. A travers la question « sommes-nous où nous pensons être », cette thèse est tout d'abord consacrée à l'étude du contrôle de la position de la cible définie avant l'intervention et de la position des électrodes implantées sur l'imagerie par résonance magnétique (IRM). Cette approche anatomique permettra d'identifier plus précisément la (les) structure(s) influencées par la stimulation électrique. Ensuite, une étude de la corrélation existant entre la position de la cible préopératoire et la position des électrodes implantées est effectuée. Elle a pour but de mettre en évidence les facteurs influençant les résultats de cette corrélation. Enfin, le travail dans son ensemble est un « contrôle de qualité » des étapes cruciales de la stimulation du noyau sous-thalamique : premièrement, des méthodes de localisation de la cible et des électrodes implantées effectuées sur IRM, développées en collaboration avec le service de Radiologie ; deuxièmement, de la méthode d'implantation utilisée à ce jour chez plus de 50 patients dans le service de Neurochirurgie du Centre Hospitalier Universitaire Vaudois en collaboration avec le service de Neurologie. Ce travail s'adresse spécialement aux équipes médicales pluridisciplinaires impliquées dans le traitement chirurgical des mouvements anormaux, incluant également des neurophysiologistes, des neuropsychologues et des psychiatres.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Limbic encephalitis (LE) with waxing and waning neuropsychiatric manifestations including behavioral, personality, psychiatric, and memory changes can evolve over days to months. Many features of LE show remarkable overlap with the characteristics of mesial-temporal (limbic) status epilepticus (MTLSE or LSE). With LE, these prolonged impaired states are assumed not to be due to ongoing epileptic activity or MTLSE, because scalp EEGs usually show no epileptiform spike-wave activity; cycling behavioral and motor changes are attributed to LE; there may be little immediate improvement with antiepileptic drugs (AEDs); and of course, implanted electrodes are rarely used. Conversely, it is known that in pre-surgical patients with refractory limbic epilepsy, implanted electrodes have revealed limbic seizures that cannot be seen at the scalp. This paper assembles a chain of inferences to advance the proposition that refractory LE might represent LSE more often than is thought, and that implanted electrodes should be considered in some cases. We present two cases that suggest that LE was also LSE, one of which warranted implanted electrodes (case 1).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECT: The aim of this study was to evaluate the long-term safety and efficacy of bilateral contemporaneous deep brain stimulation (DBS) in patients who have levodopa-responsive parkinsonism with untreatable motor fluctuations. Bilateral pallidotomy carries a high risk of corticobulbar and cognitive dysfunction. Deep brain stimulation offers new alternatives with major advantages such as reversibility of effects, minimal permanent lesions, and adaptability to individual needs, changes in medication, side effects, and evolution of the disease. METHODS: Patients in whom levodopa-responsive parkinsonism with untreatable severe motor fluctuations has been clinically diagnosed underwent bilateral pallidal magnetic resonance image-guided electrode implantation while receiving a local anesthetic. Pre- and postoperative evaluations at 3-month intervals included Unified Parkinson's Disease Rating Scale (UPDRS) scoring, Hoehn and Yahr staging, 24-hour self-assessments, and neuropsychological examinations. Six patients with a mean age of 55 years (mean 42-67 years), a mean duration of disease of 15.5 years (range 12-21 years), a mean "on/off' Hoehn and Yahr stage score of 3/4.2 (range 3-5), and a mean "off' time of 40% (range 20-50%) underwent bilateral contemporaneous pallidal DBS, with a minimum follow-up period lasting 24 months (range 24-30 months). The mean dose of levodopa in these patients could not be changed significantly after the procedure and pergolide was added after 12 months in five patients because of recurring fluctuations despite adjustments in stimulation parameters. All but two patients had no fluctuations until 9 months. Two of the patients reported barely perceptible fluctuations at 12 months and two at 15 months; however, two patients remain without fluctuations at 2 years. The mean improvements in the UPDRS motor score in the off time and the activities of daily living (ADL) score were more than 50%; the mean off time decreased from 40 to 10%, and the mean dyskinesia and complication of treatment scores were reduced to one-third until pergolide was introduced at 12 months. No significant improvement in "on" scores was observed. A slight worsening after 1 year was observed and three patients developed levodopa- and stimulation-resistant gait ignition failure and minimal fluctuations at 1 year. Side effects, which were controlled by modulation of stimulation, included dysarthria, dystonia, and confusion. CONCLUSIONS: Bilateral pallidal DBS is safe and efficient in patients who have levodopa-responsive parkinsonism with severe fluctuations. Major improvements in motor score, ADL score, and off time persisted beyond 2 years after the operation, but signs of decreased efficacy started to be seen after 12 months.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a novel approach for analyzing single-trial electroencephalography (EEG) data, using topographic information. The method allows for visualizing event-related potentials using all the electrodes of recordings overcoming the problem of previous approaches that required electrode selection and waveforms filtering. We apply this method to EEG data from an auditory object recognition experiment that we have previously analyzed at an ERP level. Temporally structured periods were statistically identified wherein a given topography predominated without any prior information about the temporal behavior. In addition to providing novel methods for EEG analysis, the data indicate that ERPs are reliably observable at a single-trial level when examined topographically.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oxygen consumption of collagenase-liberated rat adipocytes was measured by two different techniques: a microspectrophotometric method using hemoglobin as indicator of respiration and a technique using the oxygen electrode. These two completely different techniques gave similar values for oxygen consumption. With the spectrophotometric method, the oxygen consumption of single fat cells was determined. A close positive correlation (r = greater than 0.90) between oxygen consumption and fat cell size was observed in each tissue examined. With the oxygen electrode technique, oxygen consumption of adipocyte suspensions from young (40 days, 180 g) and old (90 days, 480 g) rats was examined. Fat cells of the suspensions were separated into classes of different size by a flotation technique. A significant positive correlation between fat cell size and oxygen consumption was observed in both young (r = 0.88) and old (r = 0.95) rats. However, the slope was much steeper in young rats. At a cell weight of 0.1 microgram the oxygen consumption was 0.364 and 0.086 microL O2/10(6) cells/min-1 in young and old rats, respectively. In the literature, a number of separate metabolic pathways have been found to be related positively to fat cell size and negatively to age. We conclude that these scattered metabolic observations are in agreement with integrated data on energy expenditure as evaluated from oxygen consumption. Estimations of the energy expenditure of adipose tissue indicates that this tissue is responsible for about 1% and 0.5% of the total energy expenditure in young and old rats, respectively.