43 resultados para MEASURE
Resumo:
The available virus-like particle (VLP)-based prophylactic vaccines against specific human papillomavirus (HPV) types afford close to 100% protection against the type-associated lesions and disease. Based on papillomavirus animal models, it is likely that protection against genital lesions in humans is mediated by HPV type-restricted neutralizing antibodies that transudate or exudate at the sites of genital infection. However, a correlate of protection was not established in the clinical trials because few disease cases occurred, and true incident infection could not be reliably distinguished from the emergence or reactivation of prevalent infection. In addition, the current assays for measuring vaccine-induced antibodies, even the gold standard HPV pseudovirion (PsV) in vitro neutralization assay, may not be sensitive enough to measure the minimum level of antibodies needed for protection. Here, we characterize the recently developed model of genital challenge with HPV PsV and determine the minimal amounts of VLP-induced neutralizing antibodies that can afford protection from genital infection in vivo after transfer into recipient mice. Our data show that serum antibody levels >100-fold lower than those detectable by in vitro PsV neutralization assays are sufficient to confer protection against an HPV PsV genital infection in this model. The results clearly demonstrate that, remarkably, the in vivo assay is substantially more sensitive than in vitro PsV neutralization and thus may be better suited for studies to establish correlates of protection.
Resumo:
Large numbers and functionally competent T cells are required to protect from diseases for which antibody-based vaccines have consistently failed (1), which is the case for many chronic viral infections and solid tumors. Therefore, therapeutic vaccines aim at the induction of strong antigen-specific T-cell responses. Novel adjuvants have considerably improved the capacity of synthetic vaccines to activate T cells, but more research is necessary to identify optimal compositions of potent vaccine formulations. Consequently, there is a great need to develop accurate methods for the efficient identification of antigen-specific T cells and the assessment of their functional characteristics directly ex vivo. In this regard, hundreds of clinical vaccination trials have been implemented during the last 15 years, and monitoring techniques become more and more standardized.
Resumo:
Careers today increasingly require engagement in proactive career behaviors; however, there is a lack of validated measures assessing the general degree to which somebody is engaged in such career behaviors. We describe the results of six studies with six independent samples of German university students (total N = 2,854), working professionals (total N = 561), and university graduates (N = 141) that report the development and validation of the Career Engagement Scale - a measure of the degree to which somebody is proactively developing her or his career as expressed by diverse career behaviors. The studies provide support for measurement invariance across gender and time. In support of convergent and discriminant validity, we find that career engagement is more prevalent among working professionals than among university students and that this scale has incremental validity above several specific career behaviors regarding its relation to vocational identity clarity and career self-efficacy beliefs among students and to job and career satisfaction among employees. In support of incremental predictive validity, beyond the effects of several more specific career behaviors, career engagement while at university predicts higher job and career satisfaction several months later after beginning work.
Resumo:
BACKGROUND: The purpose of this study is to validate the Pulvers silhouette showcard as a measure of weight status in a population in the African region. This tool is particularly beneficial when scarce resources do not allow for direct anthropometric measurements due to limited survey time or lack of measurement technology in face-to-face general-purpose surveys or in mailed, online, or mobile device-based surveys. METHODS: A cross-sectional study was conducted in the Republic of Seychelles with a sample of 1240 adults. We compared self-reported body sizes measured by Pulvers' silhouette showcards to four measurements of body size and adiposity: body mass index (BMI), body fat percent measured, waist circumference, and waist to height ratio. The accuracy of silhouettes as an obesity indicator was examined using sex-specific receiver operator curve (ROC) analysis and the reliability of this tool to detect socioeconomic gradients in obesity was compared to BMI-based measurements. RESULTS: Our study supports silhouette body size showcards as a valid and reliable survey tool to measure self-reported body size and adiposity in an African population. The mean correlation coefficients of self-reported silhouettes with measured BMI were 0.80 in men and 0.81 in women (P < 0.001). The silhouette showcards also showed high accuracy for detecting obesity as per a BMI ≥ 30 (Area under curve, AUC: 0.91/0.89, SE: 0.01), which was comparable to other measured adiposity indicators: fat percent (AUC: 0.94/0.94, SE: 0.01), waist circumference (AUC: 0.95/0.94, SE: 0.01), and waist to height ratio (AUC: 0.95/0.94, SE: 0.01) amongst men and women, respectively. The use of silhouettes in detecting obesity differences among different socioeconomic groups resulted in similar magnitude, direction, and significance of association between obesity and socioeconomic status as when using measured BMI. CONCLUSIONS: This study highlights the validity and reliability of silhouettes as a survey tool for measuring obesity in a population in the African region. The ease of use and cost-effectiveness of this tool makes it an attractive alternative to measured BMI in the design of non-face-to-face online- or mobile device-based surveys as well as in-person general-purpose surveys of obesity in social sciences, where limited resources do not allow for direct anthropometric measurements.
Resumo:
Bandura (1986) developed the concept of moral disengagement to explain how individuals can engage in detrimental behavior while experiencing low levels of negative feelings such as guilt-feelings. Most of the research conducted on moral disengagement investigated this concept as a global concept (e.g., Bandura, Barbaranelli, Caprara, & Pastorelli, 1996; Moore, Detert, Klebe Treviño, Baker, & Mayer, 2012) while Bandura (1986, 1990) initially developed eight distinct mechanisms of moral disengagement grouped into four categories representing the various means through which moral disengagement can operate. In our work, we propose to develop measures of this concept based on its categories, namely rightness of actions, rejection of personal responsibility, distortion of negative consequences, and negative perception of the victims, and which is not specific a particular area of research. Through our measures, we aim at better understanding the cognitive process leading individuals to behave unethically by investigating which category plays a role in explaining unethical behavior depending on the situations in which individuals are. To this purpose, we conducted five studies to develop the measures and to test its predictive validity. Particularly, we assessed the ability of the newly developed measures to predict two types of unethical behaviors, i.e. discriminatory behavior and cheating behavior. Confirmatory Factor analyses demonstrated a good fit of the model and findings generally supported our predictions.
Resumo:
A photonic system has been developed that enables sensitive quantitative determination of reactive oxygen species (ROS) - mainly hydrogen peroxide (H2O2) - in aerosol samples such as airborne nanoparticles and exhaled air from patients. The detection principle relies on the amplification of the absorbance under multiple scattering conditions due to optical path lengthening [1] and [2]. In this study, the presence of cellulose membrane that acts as random medium into the glass optical cell considerably improved the sensitivity of the detection based on colorimetric FOX assay (FeII/orange xylenol). Despite the loss of assay volume (cellulose occupies 75% of cell volume) the limit of detection is enhanced by one order of magnitude reaching the value of 9 nM (H2O2 equivalents). Spectral analysis is performed automatically with a periodicity of 5 to 15 s, giving rise to real-time ROS measurements. Moreover, the elution of air sample into the collection chamber via a micro-diffuser (impinger) enables quantitative determination of ROS contained in or generated from airborne samples. As proof-of-concept the photonic ROS detection system was used in the determination of both ROS generated from traffic pollution and ROS contained in the exhaled breath as lung inflammation biomarkers.
Resumo:
BACKGROUND: A single overall rating of quality of life (QoL) is a sensitive method that is often used in population surveys. However, the exact meaning of response choices is unclear. In particular, uneven spacing may affect the way QoL ratings should be analyzed and interpreted. This study aimed to determine the intervals between response choices to a single-item QoL assessment. METHODS: A secondary analysis was conducted on data from the Lc65+ cohort study and two additional, population-based, stratified random samples of older people (N = 5,300). Overall QoL was rated as excellent, very good, good, fair or poor. A QoL score (range 0-100) was derived from participants' answers to a 28-item QoL assessment tool. A transformed QoL score ranging from 1 (poor) to 5 (excellent) was calculated. The same procedure was repeated to compute seven domain-specific QoL subscores (Feeling of safety; Health and mobility; Autonomy; Close entourage; Material resources; Esteem and recognition; Social and cultural life). RESULTS: Mean (95 % confidence intervals) QoL scores were 96.23 (95.81-96.65) for excellent, 93.09 (92.74-93.45) for very good, 81.45 (80.63-82.27) for good, 65.44 (62.67-68.20) for fair and 54.52 (45.31-63.73) for poor overall QoL, corresponding to transformed QoL scores of respectively 5.00, 4.70, 3.58, 2.05, and 1.00. Ordinality of the categories excellent to poor was preserved in all seven QoL subscores. CONCLUSIONS: The excellent-to-poor rating scale provides an ordinal measure of overall QoL. The intervals between response choices are unequal, but an interval scale can be obtained after adequate recoding of excellent, very good, good, fair and poor.