58 resultados para Livingston, Leon Ray 1872-
Resumo:
Introduction: Growth is a central process in paediatrics. Weight and height evaluation are therefore routine exams for every child but in some situation, particularly inflammatory bowel disease (IBD), a wider evaluation of nutritional status needs to be performed. Objectives: To assess the accuracy of bio-impedance analysis (BIA) compared to the gold standard dual energy X-ray absorptiometry (DEXA) in estimating percentage body fat (fat mass; FM) and lean body mass (fat free mass; FFM) in children with inflammatory bowel disease (IBD). To compare FM and FFM levels between patients with IBD and healthy controls. Methods: Twenty-nine healthy controls (12 females; mean age: 12.7 ± 1.9 years) and 21 patients (11 females; 14.3 ± 1.3 years) were recruited from August 2011 to October 2012 at our institution. BIA was performed in all children and DEXA in patients only. Concordance between BIA and DEXA was assessed using Lin's concordance correlation and the Bland-Altman method. Between-group comparisons were made using analysis of variance adjusting for age. Results: BIA-derived FM% showed a good concordance with DEXA-derived values, while BIA-derived FFM% tended to be slightly higher than DEXA-derived values (table). No differences were found between patients and controls regarding body mass index (mean ± SD: 19.3 ± 3.3 vs. 20.1 ± 2.8 kg/m2, respectively; age-adjusted P = 0.08) and FM% (boys: 25.3 ± 10.2 vs. 22.6 ± 7.1%, for patients and controls, respectively; P = 0.20; girls: 28.2 ± 5.7 vs. 26.4 ± 7.7%; P = 0.91). Also, no differences were found regarding FFM% in boys (74.9 ± 10.2 vs. 77.4 ± 7.1%; P = 0.22) and girls (71.8 ± 5.6 vs. 73.5 ± 7.7%; P = 0.85). Conclusion: BIA adequately assesses body composition (FM%) in children with IBD and could advantageously replace DEXA, which is more expensive and less available. No differences in body composition were found between children with IBD and healthy controls.
Resumo:
X-ray imaging with grating interferometry has previously been regarded as a technique providing information only in direct space. It delivers absorption, phase, and dark-field contrast, which can be viewed as parameters of the underlying but unresolved scattering distribution. Here, we present a method that provides the ultrasmall-angle x-ray scattering distribution and, thus, allows simultaneous access to direct and reciprocal space information.
Resumo:
Regulator of G-protein signalling (RGS) proteins negatively regulate heterotrimeric G-protein signalling through their conserved RGS domains. RGS domains act as GTPase-activating proteins, accelerating the GTP hydrolysis rate of the activated form of Gα-subunits. Although omnipresent in eukaryotes, RGS proteins have not been adequately analysed in non-mammalian organisms. The Drosophila melanogaster Gαo-subunit and the RGS domain of its interacting partner CG5036 have been overproduced and purified; the crystallization of the complex of the two proteins using PEG 4000 as a crystallizing agent and preliminary X-ray crystallographic analysis are reported. Diffraction data were collected to 2.0 Å resolution using a synchrotron-radiation source.
Resumo:
Monalysin was recently described as a novel pore-forming toxin (PFT) secreted by the Drosophila pathogen Pseudomonas entomophila. Recombinant monalysin is multimeric in solution, whereas PFTs are supposed to be monomeric until target membrane association. Monalysin crystals were obtained by the hanging-drop vapour-diffusion method using PEG 8000 as precipitant. Preliminary X-ray diffraction analysis revealed that monalysin crystals belonged to the monoclinic space group C2, with unit-cell parameters a = 162.4, b = 146.2, c = 144.4 Å, β = 122.8°, and diffracted to 2.85 Å resolution using synchrotron radiation. Patterson self-rotation analysis and Matthews coefficient calculation indicate that the asymmetric unit contains nine copies of monalysin. Heavy-atom derivative data were collected and a Ta6Br14 cluster derivative data set confirmed the presence of ninefold noncrystallographic symmetry.
Resumo:
The present study was carried out to check whether classic osteometric parameters can be determined from the 3D reconstructions of MSCT (multislice computed tomography) scans acquired in the context of the Virtopsy project. To this end, four isolated and macerated skulls were examined by six examiners. First the skulls were conventionally (manually) measured using 32 internationally accepted linear measurements. Then the skulls were scanned by the use of MSCT with slice thicknesses of 1.25 mm and 0.63 mm, and the 33 measurements were virtually determined on the digital 3D reconstructions of the skulls. The results of the traditional and the digital measurements were compared for each examiner to figure out variations. Furthermore, several parameters were measured on the cranium and postcranium during an autopsy and compared to the values that had been measured on a 3D reconstruction from a previously acquired postmortem MSCT scan. The results indicate that equivalent osteometric values can be obtained from digital 3D reconstructions from MSCT scans using a slice thickness of 1.25 mm, and from conventional manual examinations. The measurements taken from a corpse during an autopsy could also be validated with the methods used for the digital 3D reconstructions in the context of the Virtopsy project. Future aims are the assessment and biostatistical evaluation in respect to sex, age and stature of all data sets stored in the Virtopsy project so far, as well as of future data sets. Furthermore, a definition of new parameters, only measurable with the aid of MSCT data would be conceivable.
Resumo:
Impressive developments in X-ray imaging are associated with X-ray phase contrast computed tomography based on grating interferometry, a technique that provides increased contrast compared with conventional absorption-based imaging. A new "single-step" method capable of separating phase information from other contributions has been recently proposed. This approach not only simplifies data-acquisition procedures, but, compared with the existing phase step approach, significantly reduces the dose delivered to a sample. However, the image reconstruction procedure is more demanding than for traditional methods and new algorithms have to be developed to take advantage of the "single-step" method. In the work discussed in this paper, a fast iterative image reconstruction method named OSEM (ordered subsets expectation maximization) was applied to experimental data to evaluate its performance and range of applicability. The OSEM algorithm with different subsets was also characterized by comparison of reconstruction image quality and convergence speed. Computer simulations and experimental results confirm the reliability of this new algorithm for phase-contrast computed tomography applications. Compared with the traditional filtered back projection algorithm, in particular in the presence of a noisy acquisition, it furnishes better images at a higher spatial resolution and with lower noise. We emphasize that the method is highly compatible with future X-ray phase contrast imaging clinical applications.
Resumo:
Well developed experimental procedures currently exist for retrieving and analyzing particle evidence from hands of individuals suspected of being associated with the discharge of a firearm. Although analytical approaches (e.g. automated Scanning Electron Microscopy with Energy Dispersive X-ray (SEM-EDS) microanalysis) allow the determination of the presence of elements typically found in gunshot residue (GSR) particles, such analyses provide no information about a given particle's actual source. Possible origins for which scientists may need to account for are a primary exposure to the discharge of a firearm or a secondary transfer due to a contaminated environment. In order to approach such sources of uncertainty in the context of evidential assessment, this paper studies the construction and practical implementation of graphical probability models (i.e. Bayesian networks). These can assist forensic scientists in making the issue tractable within a probabilistic perspective. The proposed models focus on likelihood ratio calculations at various levels of detail as well as case pre-assessment.
Resumo:
Glucose metabolism is difficult to image with cellular resolution in mammalian brain tissue, particularly with (18) fluorodeoxy-D-glucose (FDG) positron emission tomography (PET). To this end, we explored the potential of synchrotron-based low-energy X-ray fluorescence (LEXRF) to image the stable isotope of fluorine (F) in phosphorylated FDG (DG-6P) at 1 μm(2) spatial resolution in 3-μm-thick brain slices. The excitation-dependent fluorescence F signal at 676 eV varied linearly with FDG concentration between 0.5 and 10 mM, whereas the endogenous background F signal was undetectable in brain. To validate LEXRF mapping of fluorine, FDG was administered in vitro and in vivo, and the fluorine LEXRF signal from intracellular trapped FDG-6P over selected brain areas rich in radial glia was spectrally quantitated at 1 μm(2) resolution. The subsequent generation of spatial LEXRF maps of F reproduced the expected localization and gradients of glucose metabolism in retinal Müller glia. In addition, FDG uptake was localized to periventricular hypothalamic tanycytes, whose morphological features were imaged simultaneously by X-ray absorption. We conclude that the high specificity of photon emission from F and its spatial mapping at ≤1 μm resolution demonstrates the ability to identify glucose uptake at subcellular resolution and holds remarkable potential for imaging glucose metabolism in biological tissue. © 2012 Wiley Periodicals, Inc.
Resumo:
Nutrition assessment is important during chronic respiratory insufficiency to evaluate the level of malnutrition or obesity and should include body composition measurements. The appreciation of fat-free and fat reserves in patients with chronic respiratory insufficiency can aid in designing an adapted nutritional support, e.g., nutritional support in malnutrition and food restriction in obesity. The purpose of the present study was to cross-validate fat-free and fat mass obtained by various bioelectric impedance (BIA) formulas with the fat-free and fat mass measured by dual-energy X-ray absorptiometry (DXA) and determine the formulas that are best suited to predict the fat-free and fat mass for a group of patients with severe chronic respiratory insufficiency. Seventy-five patients (15 women and 60 men) with chronic obstructive and restrictive respiratory insufficiency aged 45-86 y were included in this study. Body composition was calculated according to 13 different BIA formulas for women and 12 for men and compared with DXA. Because of the variability, calculated as 2 standard deviations, of +/- 5.0 kg fat-free mass for women and +/- 6.4 kg for men for the best predictive formula, the use of the various existing BIA formulas was considered not clinically relevant. Therefore disease-specific formulas for patients with chronic respiratory insufficiency should be developed to improve the prediction of fat-free and fat mass by BIA in these patients.