246 resultados para LIVE-ANIMAL ULTRASOUND
Resumo:
In recent years, management of abdominal pain in emergency care units (ECU) has undergone a radical change. Chronic work overload of ECU and increase in severity and complexity of cases required an optimal medical imaging method, such as ultrasound, to establish an accurate diagnosis as quickly as possible. A great variety of causes may cause acute abdominal pain and the role of sonography is to accurately distinguish between these aetiologies. For the application of sonography, perhaps more so than with other imaging methods, a perfect knowledge of sonographical characteristics and technical possibilities is essential to achieve an optimal answer. The purpose of this review is to present and discuss the sonographic characteristics of extra-digestive causes of acute abdominal pain such as splenic infarction, thoracic pathologies, urinary and gynaecologic diseases or retroperitoneal pathologies.
Resumo:
WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: The AMS 800 urinary control system is the gold standard for the treatment of urinary incontinence due to sphincter insufficiency. Despite excellent functional outcome and latest technological improvements, the revision rate remains significant. To overcome the shortcomings of the current device, we developed a modern electromechanical artificial urinary sphincter. The results demonstrated that this new sphincter is effective and well tolerated up to 3 months. This preliminary study represents a first step in the clinical application of novel technologies and an alternative compression mechanism to the urethra. OBJECTIVES: To evaluate the effectiveness in continence achievement of a new electromechanical artificial urinary sphincter (emAUS) in an animal model. To assess urethral response and animal general response to short-term and mid-term activation of the emAUS. MATERIALS AND METHODS: The principle of the emAUS is electromechanical induction of alternating compression of successive segments of the urethra by a series of cuffs activated by artificial muscles. Between February 2009 and May 2010 the emAUS was implanted in 17 sheep divided into three groups. The first phase aimed to measure bladder leak point pressure during the activation of the device. The second and third phases aimed to assess tissue response to the presence of the device after 2-9 weeks and after 3 months respectively. Histopathological and immunohistochemistry evaluation of the urethra was performed. RESULTS: Bladder leak point pressure was measured at levels between 1091 ± 30.6 cmH2 O and 1244.1 ± 99 cmH2 O (mean ± standard deviation) depending on the number of cuffs used. At gross examination, the explanted urethra showed no sign of infection, atrophy or stricture. On microscopic examination no significant difference in structure was found between urethral structure surrounded by a cuff and control urethra. In the peripheral tissues, the implanted material elicited a chronic foreign body reaction. Apart from one case, specimens did not show significant presence of lymphocytes, polymorphonuclear leucocytes, necrosis or cell degeneration. Immunohistochemistry confirmed the absence of macrophages in the samples. CONCLUSIONS: This animal study shows that the emAUS can provide continence. This new electronic controlled sequential alternating compression mechanism can avoid damage to urethral vascularity, at least up to 3 months after implantation. After this positive proof of concept, long-term studies are needed before clinical application could be considered.
Resumo:
OBJECTIVE: Prospective studies have shown that quantitative ultrasound (QUS) techniques predict the risk of fracture of the proximal femur with similar standardised risk ratios to dual-energy x-ray absorptiometry (DXA). Few studies have investigated these devices for the prediction of vertebral fractures. The Basel Osteoporosis Study (BOS) is a population-based prospective study to assess the performance of QUS devices and DXA in predicting incident vertebral fractures. METHODS: 432 women aged 60-80 years were followed-up for 3 years. Incident vertebral fractures were assessed radiologically. Bone measurements using DXA (spine and hip) and QUS measurements (calcaneus and proximal phalanges) were performed. Measurements were assessed for their value in predicting incident vertebral fractures using logistic regression. RESULTS: QUS measurements at the calcaneus and DXA measurements discriminated between women with and without incident vertebral fracture, (20% height reduction). The relative risks (RRs) for vertebral fracture, adjusted for age, were 2.3 for the Stiffness Index (SI) and 2.8 for the Quantitative Ultrasound Index (QUI) at the calcaneus and 2.0 for bone mineral density at the lumbar spine. The predictive value (AUC (95% CI)) of QUS measurements at the calcaneus remained highly significant (0.70 for SI, 0.72 for the QUI, and 0.67 for DXA at the lumbar spine) even after adjustment for other confounding variables. CONCLUSIONS: QUS of the calcaneus and bone mineral density measurements were shown to be significant predictors of incident vertebral fracture. The RRs for QUS measurements at the calcaneus are of similar magnitude as for DXA measurements.
Resumo:
BACKGROUND: In contrast to mammalian erythrocytes, which have lost their nucleus and mitochondria during maturation, the erythrocytes of almost all other vertebrate species are nucleated throughout their lifespan. Little research has been done however to test for the presence and functionality of mitochondria in these cells, especially for birds. Here, we investigated those two points in erythrocytes of one common avian model: the zebra finch (Taeniopygia guttata). RESULTS: Transmission electron microscopy showed the presence of mitochondria in erythrocytes of this small passerine bird, especially after removal of haemoglobin interferences. High-resolution respirometry revealed increased or decreased rates of oxygen consumption by erythrocytes in response to the addition of respiratory chain substrates or inhibitors, respectively. Fluorometric assays confirmed the production of mitochondrial superoxide by avian erythrocytes. Interestingly, measurements of plasmatic oxidative markers indicated lower oxidative stress in blood of the zebra finch compared to a size-matched mammalian model, the mouse. CONCLUSIONS: Altogether, those findings demonstrate that avian erythrocytes possess functional mitochondria in terms of respiratory activities and reactive oxygen species (ROS) production. Interestingly, since blood oxidative stress was lower for our avian model compared to a size-matched mammalian, our results also challenge the idea that mitochondrial ROS production could have been one actor leading to this loss during the course of evolution. Opportunities to assess mitochondrial functioning in avian erythrocytes open new perspectives in the use of birds as models for longitudinal studies of ageing via lifelong blood sampling of the same subjects.
Resumo:
Purpose: Extension of retinoblastoma cells anterior to the vitreous surface is a criteria used to categorize retinoblastomas in Group E. In some cases, the assessment of anterior chamber invasion is readily visible by slit lamp examination, but in other cases, invasion of the posterior chamber is clinically difficult to determinate. Ultrasound biomicroscopy (UBM) allows high-resolution images of the anterior segment and structures normally hidden from clinical visualization such as ciliary body, zonule or posterior chamber. This prompted us to evaluate the value of UBM in the assessment of posterior and anterior chamber involvement in patients with peripheral extending retinoblastomas. Methods: We retrospectively reviewed all retinoblastoma cases that underwent enucleation in our institution from 1.1996 till 12.2009 in which UBM ( 35-MHz or 50-MHz) evaluation was available. The UBM results were compared with the histopathological data. Results: From 1.1996 till 12.2009, 146 enucleations were performed in our institution. UBM information was available in 18 cases. There were 8 males and 10 females. The mean age was 4 years old. UBM allowed correct assessement of posterior chamber invasion in 15 cases (13 cases with retinoblastoma in the posterior chamber and 2 cases without retinoblastoma in the posterior chamber). There was a significant correlation between the presence of retinoblastoma cells in the posterior chamber detected by UBM and the histopathological confirmation of posterior chamber involvement (p=0,0008). The sensitivity of UBM in the assessment of posterior chamber invasion by retinoblastoma was 81% and the specificity 100%. UBM allowed correct assessment of anterior chamber invasion in 13 cases. The sensitivity of UBM for this purpose was 50% and the specificity 60 %. Conclusions: In selected cases of advanced retinoblastoma, UBM appears to represent a valuable tool in the evaluation of the precise extension of the disease. Although our series encompasses only a limited number of cases, the sensitivity and specificity of UBM in the assessment of retinoblastoma anterior extension is interesting. Further prospective multi-centered clinical studies would be necessary to better delineate the utility of this method in the precise categorization of retinoblastoma anterior extension
Resumo:
BACKGROUND AND OBJECTIVES: The suprascapular nerve (SSN) block is frequently performed for different shoulder pain conditions and for perioperative and postoperative pain control after shoulder surgery. Blind and image-guided techniques have been described, all of which target the nerve within the supraspinous fossa or at the suprascapular notch. This classic target point is not always ideal when ultrasound (US) is used because it is located deep under the muscles, and hence the nerve is not always visible. Blocking the nerve in the supraclavicular region, where it passes underneath the omohyoid muscle, could be an attractive alternative. METHODS: In the first step, 60 volunteers were scanned with US, both in the supraclavicular and the classic target area. The visibility of the SSN in both regions was compared. In the second step, 20 needles were placed into or immediately next to the SSN in the supraclavicular region of 10 cadavers. The accuracy of needle placement was determined by injection of dye and following dissection. RESULTS: In the supraclavicular region of volunteers, the nerve was identified in 81% of examinations (95% confidence interval [CI], 74%-88%) and located at a median depth of 8 mm (interquartile range, 6-9 mm). Near the suprascapular notch (supraspinous fossa), the nerve was unambiguously identified in 36% of examinations (95% CI, 28%-44%) (P < 0.001) and located at a median depth of 35 mm (interquartile range, 31-38 mm; P < 0.001). In the cadaver investigation, the rate of correct needle placement of the supraclavicular approach was 95% (95% CI, 86%-100%). CONCLUSIONS: Visualization of the SSN with US is better in the supraclavicular region as compared with the supraspinous fossa. The anatomic dissections confirmed that our novel supraclavicular SSN block technique is accurate.
Resumo:
The Atripump is a motorless, volume displacement pump based on artificial muscle technology that could reproduce the pump function of normal atrium. It could help prevent blood clots due to blood stagnation and eventually avoid anticoagulation therapy in atrial fibrillation (AF). An animal study has been designed to assess mechanical effects of this pump on fibrillating atrium. The Atripump is a dome shaped silicone coated nitinol actuator. A pacemaker like control unit drives the actuator. In five adult sheep, the right atrium (RA) was exposed and dome sutured onto the epicardium. Atrial fibrillation was induced using rapid epicardial pacing (600 beats/min). Ejection fraction of the RA was obtained with intracardiac ultrasound in baseline, AF and Atripump assisted AF conditions. The dome's contraction rate was 60/min with power supply of 12V, 400 mA for 200 ms and ran for 2 hours in total. Mean temperature on the RA was 39+/-1.5 degrees C. Right atrium ejection fraction was 31% in baseline conditions, 5% and 20% in AF and assisted AF, respectively. In two animals a thrombus appeared in the right appendix and washed out once the pump was turned on. The Atripump washes blood out the RA acting as an anticoagulant device. Possible clinical implications in patients with chronic AF are prevention of embolism of cardiac origin and avoidance of hemorrhagic complication due to chronic anticoagulation.