104 resultados para IMPLANT-SUPPORTED FIXED PROSTHESIS
Resumo:
Stiffness tomography is a new atomic force microscopy imaging technique that allows highlighting structures located underneath the surface of the sample. In this imaging mode, such structures are identified by investigating their mechanical properties. We present here, for the first time, a description of the use of this technique to acquire detailed stiffness maps of fixed and living macrophages. Indeed, the mechanical properties of several macrophages were studied through stiffness tomography imaging, allowing some insight of the structures lying below the cell's surface. Through these investigations, we were able to evidence the presence and properties of stiff column-like features located underneath the cell membrane. To our knowledge, this is the first evidence of the presence, underneath the cell membrane, of such stiff features, which are in dimension and form compatible with phagosomes. Moreover, by exposing the cells to cytochalasin, we were able to study the induced modifications, obtaining an indication of the location and mechanical properties of the actin cytoskeleton. Copyright © 2012 John Wiley & Sons, Ltd.
Resumo:
Reversed shoulder prostheses are increasingly being used for the treatment of glenohumeral arthropathy associated with a deficient rotator cuff. These non-anatomical implants attempt to balance the joint forces by means of a semi-constrained articular surface and a medialised centre of rotation. A finite element model was used to compare a reversed prosthesis with an anatomical implant. Active abduction was simulated from 0 degrees to 150 degrees of elevation. With the anatomical prosthesis, the joint force almost reached the equivalence of body weight. The joint force was half this for the reversed prosthesis. The direction of force was much more vertically aligned for the reverse prosthesis, in the first 90 degrees of abduction. With the reversed prosthesis, abduction was possible without rotator cuff muscles and required 20% less deltoid force to achieve it. This force analysis confirms the potential mechanical advantage of reversed prostheses when rotator cuff muscles are deficient.
Resumo:
Treatment of hypertension remains a difficult task despite the availability of different types of medications lowering blood pressure by different mechanisms. In order to reach the target blood pressures recommended today combination therapy is required in most patients. The co-administration of two drugs with different impacts on the cardiovascular system markedly increases the antihypertensive effectiveness without altering adversely tolerability. Fixed low-dose combinations are becoming a valuable option not only as second-line, but also as first-line therapy. In this respect the co-administration of thiazide diuretic with an AT(1)-receptor blocker is particularly appealing. The diuretic-induced decrease in total body sodium activates the renin-angiotensin system, thus rendering blood pressure maintenance angiotensin II-dependent. During blockade of the renin-angiotensin system low doses of thiazides generally suffice, allowing the prevention of undesirable metabolic effects. Also, blockade of the AT(1)-receptor, particularly when angiotensin II production is enhanced in response to diuretic therapy, is expected to be beneficial, since angiotensin II seems to contribute importantly to the pathogenesis of cardiovascular and renal complications of hypertension.
Resumo:
It is well documented that reducing blood pressure (BP) in hypertensive individuals reduces the risk of cardiovascular (CV) events. Despite this, many patients with hypertension remain untreated or inadequately treated, and fail to reach the recommended BP goals. Suboptimal BP control, whilst arising from multiple causes, is often due to poor patient compliance and/or persistence, and results in a significant health and economic burden on society. The use of fixed-dose combinations (FDCs) for the treatment of hypertension has the potential to increase patient compliance and persistence. When compared with antihypertensive monotherapies, FDCs may also offer equivalent or better efficacy, and the same or improved tolerability. As a result, FDCs have the potential to reduce both the CV event rates and the non-drug healthcare costs associated with hypertension. When FDCs are adopted for the treatment of hypertension, issues relating to copayment, formulary restrictions and therapeutic reference pricing must be addressed.
Resumo:
Background: Mobile-bearing knee replacements have some theoretical advantages over fixed-bearing devices. However, very few randomized controlled clinical trials have been published to date, and studies showed little clinical and subjective advantages for the mobile-bearing using traditional systems of scoring. The choice of the ideal outcome measure to assess total joint replacement remains a complex issue. However, gait analysis provides objective and quantifying evidences of treatment evaluation. Significant methodological advances are currently made in gait analysis laboratories and ambulatory gait devices are now available. The goal of this study was to provide gait parameters as a new objective method to assess total knee arthroplasty outcome between patients with fixed- and mobile-bearing, using an ambulatory device with minimal sensor configuration. This randomized controlled double-blind study included to date 14 patients: the gait signatures of four patients with mobile-bearing were compared to the gait signatures of nine patients with fixed-bearing pre-operatively and post-operatively at 6 weeks, 3 months and 6 months. Each participant was asked to perform two walking trials of 30m long at his/her preferred speed and to complete a EQ-5D questionnaire, a WOMAC and Knee Society Score (KSS). Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. A new method for a portable system for gait analysis has been developed with very encouraging results regarding the objective outcome of total knee arthroplasty using mobile- and fixed-bearings.
Resumo:
Il s'agit de comparer in vivo la sécurité et l'efficacité d'un implant en polyméthylméthacrylate (PMMA) avec un implant standard en collagène dans la sclérectomie profonde (SP) sur une durée de six mois. La population étudiée comprend vingt lapins, chaque lapin étant randomisé pour une SP avec implant en PMMA dans un oeil et implant de collagène dans l'autre oeil. Plusieurs éléments ont été pris en compte dans la comparaison : - la mesure de la pression intraoculaire - l'évolution de l'espace de drainage intrascléral et de la bulle de filtration sous-conjonctivale, suivie par ultrasonographic biomicroscopique (UBM) - la croissance de nouveaux vaisseaux de drainage sous-conjonctivaux, croissance quantifiée par angiographie du segment antérieur à la fluorescéine combinée au vert d'indocyanine - la facilité à l'écoulement de l'humeur aqueuse (C), mesurée à six mois par cannulation-perfusion de la chambre antérieur - la sclère au site de SP, histologiquement comparée à la sclère native opposée à 180°, également à six mois La pression intraoculaire moyenne préopératoire à une, quatre, douze et 24 semaines postopératoires est comparable dans les deux groupes (P>0.1). L'UBM montre une régression légèrement plus rapide (statistiquement non significative) de la bulle de filtration sous-conjonctivale et la persistance d'un espace de drainage intrascléral dans le groupe PMMA (P>0.05). De nouveaux vaisseaux de drainage sont observés à un mois de la chirurgie ; à six mois, ces vaisseaux sont plus nombreux dans le groupe PMMA, tant sur l'analyse angiographique que sur l'analyse histologique (P>0.05). La facilité moyenne à l'écoulement de l'humeur aqueuse est significativement plus élevées à six mois dans les deux groupes par rapport aux valeurs préopératoires (P>0.05), sans qu'il n'y ait de différence entre les deux implants (0.24 ± 0.06 μΙ/min/mmHg [PMMA] et 0.23 ± 0.07 μΙ/min/mmHg [implant en collagène]) (Ρ = 0.39). Cette étude a pu démontrer que la sclérectomie profonde avec implant en collagène ou en PMMA donne des résultats similaires en terme de diminution de l'IOP et d'augmentation de la facilité à l'écoulement de l'humeur aqueuse, sans différence sur le plan des réactions inflammatoires post-intervention.
Resumo:
Introduction: Several studies have reported significant alteration of the scapula-humeral rythm after total shoulder arthroplasty. However, the biomechanical and clinical effects, particularly on implants lifespan, are still unknown. The goal of this study was to evaluate the biomechanical consequences of an altered scapula-humeral rhythm. Methods: A numerical musculoskeletal model of the shoulder was used. The model included the scapula, the humerus and 6 scapulohumeral muscles: middle, anterior, and posterior deltoid, supraspinatus, subscapularis and infraspinatus combined with teres minor. Arm motion and joint stability were achieved by muscles. The reverse and anatomic Aequalis prostheses (Tornier Inc) were inserted. Two scapula-humeral rhythms were considered for each prosthesis: a normal 2:1 rhythm, and an altered 1:2 rhythm. For the 4 configurations, a movement of abduction in the scapular plane was simulated. The gleno-humeral force and contact pattern, but also the stress in the polyethylene and cement were evaluated. Results: With the anatomical prosthesis, the gleno-humeral force increased of 23% for the altered rhythm, with a more eccentric (posterior and superior) contact. The contact pressure, polyethylene stress, and cement stress increased respectively by 20%, 48% and 64%. With the reverse prosthesis, the gleno-humeral force increased of 11% for an altered rhythm. There was nearly no effect on the contact pattern on the polyethylene component surface. Conclusion: The present study showed that alteration oft the scapula-humeral rythm induced biomechanical consequences which could preclude the long term survival of the glenoid implant of anatomic prostheses. However,an altered scapula-humeral rhythm, even severe, should not be a contra indication for the use of a reverse prosthesis.
Resumo:
Reconstruction of important parameters such as femoral offset and torsion is inaccurate, when templating is based on plain x-rays. We evaluate intraoperative reproducibility of pre-operative CT-based 3D-templating in a consecutive series of 50 patients undergoing primary cementless THA through an anterior approach. Pre-operative planning was compared to a postoperative CT scan by image fusion. The implant size was correctly predicted in 100% of the stems, 94% of the cups and 88% of the heads (length). The difference between the planned and the postoperative leg length was 0.3 + 2.3 mm. Values for overall offset, femoral anteversion, cup inclination and anteversion were 1.4 mm ± 3.1, 0.6° ± 3.3°, -0.4° ± 5° and 6.9° ± 11.4°, respectively. This planning allows accurate implant size prediction. Stem position and cup inclination are accurately reproducible.
Total knee arthroplasty - a clinical and numerical study of the micromovements of the tibial implant
Resumo:
Introduction The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant.Material and Methods Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms.The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the microvements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion.Results 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present.Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns).Discussion Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established.Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.
Resumo:
Bisphosphonates are known for their strong inhibitory effect on bone resorption. Their influence on bone formation however is less clear. In this study we investigated the spatio-temporal effect of locally delivered Zoledronate on peri-implant bone formation and resorption in an ovariectomized rat femoral model. A cross-linked hyaluronic acid hydrogel was loaded with the drug and applied bilaterally in predrilled holes before inserting polymer screws. Static and dynamic bone parameters were analyzed based on in vivo microCT scans performed first weekly and then biweekly. The results showed that the locally released Zoledronate boosted bone formation rate up to 100% during the first 17 days after implantation and reduced the bone resorption rate up to 1000% later on. This shift in bone remodeling resulted in an increase in bone volume fraction (BV/TV) by 300% close to the screw and 100% further away. The double effect on bone formation and resorption indicates a great potential of Zoledronate-loaded hydrogel for enhancement of peri-implant bone volume which is directly linked to improved implant fixation.
Resumo:
BACKGROUND: Reversed shoulder arthroplasty is an accepted treatment for glenohumeral arthritis associated to rotator cuff deficiency. For most reversed shoulder prostheses, the baseplate of the glenoid component is uncemented and its primary stability is provided by a central peg and peripheral screws. Because of the importance of the primary stability for a good osteo-integration of the baseplate, the optimal fixation of the screws is crucial. In particular, the amplitude of the tightening force of the nonlocking screws is clearly associated to this stability. Since this force is unknown, it is currently not accounted for in experimental or numerical analyses. Thus, the primary goal of this work is to measure this tightening force experimentally. In addition, the tightening torque was also measured, to estimate an optimal surgical value. METHODS: An experimental setup with an instrumented baseplate was developed to measure simultaneously the tightening force, tightening torque and screwing angle, of the nonlocking screws of the Aquealis reversed prosthesis. In addition, the amount of bone volume around each screw was measured with a micro-CT. Measurements were performed on 6 human cadaveric scapulae. FINDINGS: A statistically correlated relationship (p<0.05, R=0.83) was obtained between the maximal tightening force and the bone volume. The relationship between the tightening torque and the bone volume was not statistically significant. INTERPRETATION: The experimental relationship presented in this paper can be used in numerical analyses to improve the baseplate fixation in the glenoid bone.
Resumo:
AIM: To prospectively study the intraocular pressure (IOP) lowering effect and safety of the new method of very deep sclerectomy with collagen implant (VDSCI) compared with standard deep sclerectomy with collagen implant (DSCI). METHODS: The trial involved 50 eyes of 48 patients with medically uncontrolled primary and secondary open-angle glaucoma, randomized to undergo either VDSCI procedure (25 eyes) or DSCI procedure (25 eyes). Follow-up examinations were performed before surgery and after surgery at day 1, at week 1, at months 1, 2, 3, 6, 9, 12, 18, and 24 months. Ultrasound biomicroscopy was performed at 3 and 12 months. RESULTS: Mean follow-up period was 18.6+/-5.9 (VDSCI) and 18.9+/-3.6 (DSCI) months (P=NS). Mean preoperative IOP was 22.4+/-7.4 mm Hg for VDSCI and 20.4+/-4.4 mm Hg for DSCI eyes (P=NS). Mean postoperative IOP was 3.9+/-2.3 (VDSCI) and 6.3+/-4.3 (DSCI) (P<0.05) at day 1, and 12.2+/-3.9 (VDSCI) and 13.3+/-3.4 (DSCI) (P=NS) at month 24. At the last visit, the complete success rate (defined as an IOP of < or =18 mm Hg and a percentage drop of at least 20%, achieved without medication) was 57% in VDSCI and 62% in DSCI eyes (P=NS) ultrasound biomicroscopy at 12 months showed a mean volume of the subconjunctival filtering bleb of 3.9+/-4.2 mm3 (VDSCI) and 6.8+/-7.5 mm3 (DSCI) (P=0.426) and 5.2+/-3.6 mm3 (VDSCI) and 5.4+/-2.9 mm3 (DSCI) (P=0.902) for the intrascleral space. CONCLUSIONS: Very deep sclerectomy seems to provide stable and good control of IOP at 2 years of follow-up with few postoperative complications similar to standard deep sclerectomy with the collagen implant.
Resumo:
With the advent of new technologies, experience with long-term mechanical circulatory support (MCS) is rapidly growing. Candidates to MCS are selected based on concepts, strategies and classifications that are specific to this indication. As results drastically improve, supported by stronger scientific evidence, the trend is towards earlier implantation. An adequate pre-implant follow-up is mandatory in order to avoid missing the best window of opportunity for implantation. While on chronic support, the hemodynamic profile of patients with continuous-flow ventricular assist devices is unique and remarkably influenced by the hydration status. Optimal management of these patients from the pre-implant phase to the long-term support phase requires a multidisciplinary approach that is similar to that already long validated for organ transplantation.