60 resultados para Gel-filtration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assessment of glomerular filtration rate (GFR) is critical for the diagnosis and management of renal diseases in pediatric nephrology. Ideally, it requires the measurement of the renal clearance of a filtration marker. Inulin, an exogenous marker, is the only compound the excretion of which occurs exclusively by glomerular filtration, with no tubular handling. Therefore, inulin clearance provides the most accurate method to measure GFR and is considered as the "gold standard", at all ages including very premature neonates. However, inulin dearance is cumbersome and alternative methods are used in clinical practice. If urine is available, endogenous creatinine clearance is the most reliable method. When urine collection is difficult to obtain, GFR can be estimated by the plasma concentration of endogenous markers mainly eliminated by glomerular filtration, such as creatinine, or the more recently described cystatin C and beta 2-microglobulin. When the endogenous production of these markers is constant, their plasma concentration reflects glomerular filtration; it increases with decreasing renal function. However, in pediatric patients creatinine production depends on muscle mass, which significantly increases with linear growth, as well as age and gender. Mathematical formulas taking these parameters into account have thus been developed. Among these, the so-called "Schwartz formula" is often used and is a reliable estimate of GFR in children. Finally, radionuclide renal scans can be used to evaluate the separate glomerular function of each kidney.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A statistical methodology for the objective comparison of LDI-MS mass spectra of blue gel pen inks was evaluated. Thirty-three blue gel pen inks previously studied by RAMAN were analyzed directly on the paper using both positive and negative mode. The obtained mass spectra were first compared using relative areas of selected peaks using the Pearson correlation coefficient and the Euclidean distance. Intra-variability among results from one ink and inter-variability between results from different inks were compared in order to choose a differentiation threshold minimizing the rate of false negative (i.e. avoiding false differentiation of the inks). This yielded a discriminating power of up to 77% for analysis made in the negative mode. The whole mass spectra were then compared using the same methodology, allowing for a better DP in the negative mode of 92% using the Pearson correlation on standardized data. The positive mode results generally yielded a lower differential power (DP) than the negative mode due to a higher intra-variability compared to the inter-variability in the mass spectra of the ink samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: Inulin clearance (Cin) is the gold standard for assessing glomerular filtration rate (GFR). Other methods are based on the plasma creatinine concentration (Pcreat), creatinine clearance (Ccreat), the Haycock-Schwartz formula and the plasma concentration of cystatin C (PcysC), a 13 kDa basic protein produced at a constant rate by all nucleated cells. The present prospective study was thus designed to evaluate the reliability of PcysC as a marker of GFR in comparison with that of Pcreat, Ccreat and the Haycock-Schwartz formula, using Cin as the gold standard. METHODS: Ninety-nine children (51 m/48 f), with a median age of 8.3 y (1.0-17.9) were studied. Using a cut-off for Cin of 100 ml/min per 1.73 m2, 54 children (54.5%) had impaired GFR. Those with normal GFR were comparable for age, height, weight and body mass index. RESULTS: Logistic regression, ROC analysis and linear regression all showed that Ccreat was the best parameter to discriminate between impaired and normal GFR, followed by the Haycock-Schwartz formula, PcysC, and finally Pcreat, each one being significantly more predictive than the next. CONCLUSION: GFR is better assessed by the Haycock-Schwartz formula than by PcysC or Pcreat alone. It is therefore concluded that when urine collection is not possible, simply measuring the child's Pcreat and height is the best, easiest and cheapest way to assess GFR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carcinoembryonic antigen (CEA) was identified in perchloric acid (PCA)_extract from normal colon mucosa by 2 immunological criteria: a line of identity in double diffusion and a parallel inhibition curve in radioimmunoassay (RIA), both with reference colon carcinoma-CEA (CEA-Tu). The average concentration of CEA in normal colon mucosa (CEA-No) was 35 times lower than in primary large bowel carcinomas and 230 times lower than in metastatic colon or rectum carcinomas. CEA-No was purified from PCA extracts of normal colon mucosa by Sephadex G-200 filtration and immunoadsorbent columns. Purified CEA-No had quatitatively the same inhibition activity in RIA as the British Standard CEA coded 73/601. Purified CEA-No was labelled with 125I. The percentage of binding of labelled CEA-No to a specific goat anti-CEA-Tu antiserum was similar to that of CEA-Tu. Labelled CEA-No could be used as radioactive tracer in RIA as well as labelled CEA-Tu. The physico-chemical properties of purified CEA-Tu as demonstrated by Sepharose 6 B filtration, SDS Polyacrylamide gel analysis and cesium chloride density gradient, were found to be almost identical to those of reference CEA-Tu. Preliminary results showed that CEA-No and CEA-Tu contained the same types of carbohydrates in similar proportions. A rabbit antiserum against CEA-No was obtained which demonstrated the same specificity as conventional anti-CEA-Tu antisera.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the benefits of a novel formulation of vasoactive intestinal peptide (VIP) based on the incorporation of VIP-loaded rhodamine-conjugated liposomes (VIP-Rh-Lip) within hyaluronic acid (HA) gel (Gel-VIP-Rh-Lip) for the treatment of endotoxin-induced uveitis (EIU) in comparison with VIP-Rh-Lip alone. In vitro release study and rheological analysis showed that interactions between HA chains and liposomes resulted in increased viscosity and reinforced elasticity of the gel. In vivo a single intravitreal injection of Gel-VIP-Rh-Lip was performed in rats 7 days prior to uveitis induction by subcutaneous lipopolysaccharide injection. The maximal ocular inflammation occurs within 16-24 h in controls (VIP-Rh-Lip, unloaded-Rh-Lip). Whereas intraocular injection of VIP-Rh-Lip had no effect on EIU severity compared with controls, Gel-VIP-Rh-Lip reduced significantly the clinical score and number of inflammatory cells infiltrating the eye. The fate of liposomes, VIP and HA in the eyes, regional and inguinal lymph nodes and spleen was analyzed by immunostaining and fluorescence microscopy. Retention of liposomes by HA gel was observed in vitro and in vivo. Inflammation severity seemed to impact on system stability resulting in the delayed release of VIP. Thus, HA gel containing VIP-Rh-Lip is an efficient strategy to obtain a sustained delivery of VIP in ocular and lymph node tissues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gel electrophoresis can be used to separate nicked circular DNA molecules of equal length but forming different knot types. At low electric fields, complex knots drift faster than simpler knots. However, at high electric field the opposite is the case and simpler knots migrate faster than more complex knots. Using Monte Carlo simulations we investigate the reasons of this reversal of relative order of electrophoretic mobility of DNA molecules forming different knot types. We observe that at high electric fields the simulated knotted molecules tend to hang over the gel fibres and require passing over a substantial energy barrier to slip over the impeding gel fibre. At low electric field the interactions of drifting molecules with the gel fibres are weak and there are no significant energy barriers that oppose the detachment of knotted molecules from transverse gel fibres.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gel electrophoresis allows one to separate knotted DNA (nicked circular) of equal length according to the knot type. At low electric fields, complex knots, being more compact, drift faster than simpler knots. Recent experiments have shown that the drift velocity dependence on the knot type is inverted when changing from low to high electric fields. We present a computer simulation on a lattice of a closed, knotted, charged DNA chain drifting in an external electric field in a topologically restricted medium. Using a Monte Carlo algorithm, the dependence of the electrophoretic migration of the DNA molecules on the knot type and on the electric field intensity is investigated. The results are in qualitative and quantitative agreement with electrophoretic experiments done under conditions of low and high electric fields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tissue-engineered grafts for the urinary tract are being investigated for the potential treatment of several urologic diseases. These grafts, predominantly tubular-shaped, usually require in vitro culture prior to implantation to allow cell engraftment on initially cell-free scaffolds. We have developed a method to produce tubular-shaped collagen scaffolds based on plastic compression. Our approach produces a ready cell-seeded graft that does not need further in vitro culture prior to implantation. The tubular collagen scaffolds were in particular investigated for their structural, mechanical and biological properties. The resulting construct showed an especially high collagen density, and was characterized by favorable mechanical properties assessed by axial extension and radial dilation. Young modulus in particular was greater than non-compressed collagen tubes. Seeding densities affected proliferation rate of primary human bladder smooth muscle cells. An optimal seeding density of 10(6) cells per construct resulted in a 25-fold increase in Alamar blue-based fluorescence after 2 wk in culture. These high-density collagen gel tubes, ready seeded with smooth muscle cells could be further seeded with urothelial cells, drastically shortening the production time of graft for urinary tract regeneration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High performance liquid chromatography (HPLC) is the reference method for measuring concentrations of antimicrobials in blood. This technique requires careful sample preparation. Protocols using organic solvents and/or solid extraction phases are time consuming and entail several manipulations, which can lead to partial loss of the determined compound and increased analytical variability. Moreover, to obtain sufficient material for analysis, at least 1 ml of plasma is required. This constraint makes it difficult to determine drug levels when blood sample volumes are limited. However, drugs with low plasma-protein binding can be reliably extracted from plasma by ultra-filtration with a minimal loss due to the protein-bound fraction. This study validated a single-step ultra-filtration method for extracting fluconazole (FLC), a first-line antifungal agent with a weak plasma-protein binding, from plasma to determine its concentration by HPLC. Spiked FLC standards and unknowns were prepared in human and rat plasma. Samples (240 microl) were transferred into disposable microtube filtration units containing cellulose or polysulfone filters with a 5 kDa cut-off. After centrifugation for 60 min at 15000g, FLC concentrations were measured by direct injection of the filtrate into the HPLC. Using cellulose filters, low molecular weight proteins were eluted early in the chromatogram and well separated from FLC that eluted at 8.40 min as a sharp single peak. In contrast, with polysulfone filters several additional peaks interfering with the FLC peak were observed. Moreover, the FLC recovery using cellulose filters compared to polysulfone filters was higher and had a better reproducibility. Cellulose filters were therefore used for the subsequent validation procedure. The quantification limit was 0.195 mgl(-1). Standard curves with a quadratic regression coefficient > or = 0.9999 were obtained in the concentration range of 0.195-100 mgl(-1). The inter and intra-run accuracies and precisions over the clinically relevant concentration range, 1.875-60 mgl(-1), fell well within the +/-15% variation recommended by the current guidelines for the validation of analytical methods. Furthermore, no analytical interference was observed with commonly used antibiotics, antifungals, antivirals and immunosuppressive agents. Ultra-filtration of plasma with cellulose filters permits the extraction of FLC from small volumes (240 microl). The determination of FLC concentrations by HPLC after this single-step procedure is selective, precise and accurate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare the efficacy and safety of a slowly resorbable glaucoma implant, Healaflow (HF) and Healon 5 (H5) as spacers injected into failing filtration blebs at the time of bleb needlings, augmented with MMC Methods: Eighty-four glaucoma patients with filtration bleb failure following glaucoma surgery (deep sclerectomy/ trabeculectomy) underwent bleb needling using either HF (n=44) or H5 (n=40) as an intrableb viscoelastic spacer. All needlings were augmented by MMC and performed in the operating room, by a single surgeon. The choice between HF and H5 was randomised. Postoperative data for IOP, number of glaucoma medications (GMs), antimetabolite injections (AMIs), bleb morphology and all complications were recorded at day 1 (D1), weeks 1 (W1), 4 (W4), month 6 (M6) and last visit. Success was defined as IOP≤21mmHg and 20% reduction in IOP from baseline Results: Age was comparable between groups (HF vs H5; 66 vs 72 years; p=0.13*). There were no differences in mean postoperative IOP or GMs at any time point between groups (mean IOP = HF vs H5; prior to needling=19.8mmHg vs 18.7mmHg, p=0.48*; D1=10.4mmHg vs 10.2mmHg, p=0.85*; W1=12.3mmHg vs 13.8mmHg, p=0.33*; W4=15.7mmHg vs 15.1mmHg, p=0.69*; M6=14.3mmHg vs 13.8mmHg, p=0.69*. Mean GMs= HF vs H5; prior to needling=1.7 vs 1.7, p=0.96*; M6=0.9 vs 1.1, p=0.66*). Success rates were comparable between HF and H5 groups (74% vs 71%). Requirements for AMIs were similar between groups; post filtration surgery and prior to needling (mean AMIs 1.54 vs 1.65 p=0.82*) and within the first six months following needling ( 0.77 vs 0.65 p=0.70*). Complication rates were infrequent in both groups (9%, HF; 3%, H5) * two-sample t-test Conclusions: The early to mid-term success rates of needlings using intrableb spacers were high. However there were no differences observed between the use of crosslinked and high molecular weight sodium hyaluronate

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To evaluate the safety and efficacy of infliximab as an antifibrotic agent after experimental glaucoma filtration surgery in rabbits. Methods In a randomized, prospective, masked-observer study, 30 New Zealand Albino rabbits underwent glaucoma filtration surgery. The animals were allocated to receive either intraoperative application of infliximab (group A) or mitomycin C (MMC) at a concentration of 0.2mg/ml (group B) or balanced salt solution (BSS, control)(group C). Different infliximab doses, namely 1.0mg, 2.0mg, 3.0mg, 4.0mg, 5.0mg in 0.1ml were applied. Bleb survival and characteristics were evaluated over a 30day period. The animals were killed on postoperative day 15 and 30. Histology of the operated eyes was performed to evaluate and grade the amount of scarring in each group.Cellular density was evaluated in each case. Results Infliximab did not appear to improve the outcome of filtration surgery in this model of glaucoma filtration surgery.There was a significant decrease in cellular density in the MMC group compared to the control group (p=0.0352). There was neither a significant decrease in cellular density between the infliximab group and the control group nor between the infliximab group and the MMC group. Overall there was no difference in terms of fibrosis between the three different groups. There was slightly less inflammation in the infliximab group, but not significant. Conclusions In this study intraoperative application of infliximab does not appear to be superior to the application of MMC or a control with regard to bleb survival and fibrosis. This study however demonstrates that intraoperative application of MMC significantly reduces the cellular density of the filtration bleb.