133 resultados para GAS EXCHANGE


Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: Standard cardiopulmonary bypass (CPB) circuits with their large surface area and volume contribute to postoperative systemic inflammatory reaction and hemodilution. In order to minimize these problems a new approach has been developed resulting in a single disposable, compact arterio-venous loop, which has integral kinetic-assist pumping, oxygenating, air removal, and gross filtration capabilities (CardioVention Inc., Santa Clara, CA, USA). The impact of this system on gas exchange capacity, blood elements and hemolysis is compared to that of a conventional circuit in a model of prolonged perfusion. METHODS: Twelve calves (mean body weight: 72.2+/-3.7 kg) were placed on cardiopulmonary bypass for 6 h with a flow of 5 l/min, and randomly assigned to the CardioVention system (n=6) or a standard CPB circuit (n=6). A standard battery of blood samples was taken before bypass and throughout bypass. Analysis of variance was used for comparison. RESULTS: The hematocrit remained stable throughout the experiment in the CardioVention group, whereas it dropped in the standard group in the early phase of perfusion. When normalized for prebypass values, both profiles differed significantly (P<0.01). Both O2 and CO2 transfers were significantly improved in the CardioVention group (P=0.04 and P<0.001, respectively). There was a slightly higher pressure drop in the CardioVention group but no single value exceeded 112 mmHg. No hemolysis could be detected in either group with all free plasma Hb values below 15 mg/l. Thrombocyte count, when corrected by hematocrit and normalized by prebypass values, exhibited an increased drop in the standard group (P=0.03). CONCLUSION: The CardioVention system with its concept of limited priming volume and exposed foreign surface area, improves gas exchange probably because of the absence of detectable hemodilution, and appears to limit the decrease in the thrombocyte count which may be ascribed to the reduced surface. Despite the volume and surface constraints, no hemolysis could be detected throughout the 6 h full-flow perfusion period.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Major burns are characterized by an initial capillary leak which requires fluid resuscitation for hemodynamic stabilisation. While under-resuscitation was the major cause of death until the 80ies, over-resuscitation has become an important source of complications: abdominal compartment syndrome, escharotomies, impaired gas exchange and prolonged mechanical ventilation and hospital stay. The fluid creep started in the 90ies with an increasing proportion of the first 24 hours' fluid delivery above the 4 ml/kg/% BSA Parkland prediction. The first alerts were published under the form of case reports of increased mortality due to abdominal compartment syndrome and respiratory failure. The paper analyses the causes of this fluid creep, and the ways to prevent it, which includes rationing prehospital fluid delivery, avoiding early colloids and permissive hypovolemia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A carrier system for gases and nutrients became mandatory when primitive animals grew larger and developed different organs. The first circulatory systems are peristaltic tubes pushing slowly the haemolymph into an open vascular tree without capillaries (worms). Arthropods developed contractile bulges on the abdominal aorta assisted by accessory hearts for wings or legs and by abdominal respiratory motions. Two-chamber heart (atrium and ventricle) appeared among mollusks. Vertebrates have a multi-chamber heart and a closed circulation with capillaries. Their heart has two chambers in fishes, three chambers (two atria and one ventricle) in amphibians and reptiles, and four chambers in birds and mammals. The ventricle of reptiles is partially divided in two cavities by an interventricular septum, leaving only a communication of variable size leading to a variable shunt. Blood pressure increases progressively from 15 mmHg (worms) to 170/70 mmHg (birds) according to the increase in metabolic rate. When systemic pressure exceeds 50 mmHg, a lower pressure system appears for the circulation through gills or lungs in order to improve gas exchange. A four-chamber heart allows a complete separation of systemic and pulmonary circuits. This review describes the circulatory pumping systems used in the different classes of animals, their advantages and failures, and the way they have been modified with evolution.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The thermogenic response to a 100-g oral glucose challenge was studied in 12 patients with Graves' disease using continuous indirect calorimetry. Seven hyperthyroid patients were reinvestigated under the same experimental conditions after medical therapy. The mean net increase in energy expenditure (delta EE) following the glucose challenge was the same in hyperthyroid patients as compared to a control group (delta EE = +0.15 +/- 0.02 and 0.15 +/- 0.01 kcal/min, respectively) and the treated patients (delta EE = +0.11 +/- 0.03 kcal/min ns). When expressed as a percentage of the energy content of the glucose challenge, the mean glucose induced thermogenesis was similar in all three groups: 7.0 +/- 1.0%, 7.4 +/- 0.5%, and 5.5 +/- 1.3% in hyperthyroid, control subjects, and treated patients, respectively. It is concluded that the high energy requirement of hyperthyroid patients is due primarily to an elevated resting energy expenditure. The postprandial thermogenesis in itself does not contribute to the elevated fuel utilization in Graves' disease.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A transportable, whole body indirect calorimeter, designed for use in the tropics, is described. The calorimeter was built to study energy expenditure of people having chronically or acutely low levels of food intake, and it will help to determine energy adaptations made by individuals with restricted food intake. The calorimeter comprises two units: a 27 m3 ventilated chamber connected to an office housing control and monitoring equipment. The system also allows the experimenter to assess the rate of energy expenditure by means of a ventilated hood or a baby respiration chamber. The incoming air flow rate is variable and is typically set at approximately 30 l/min. Carbon dioxide production (VCO2) and oxygen consumption (VO2) are continuously monitored by means of differential gas analysers via a computerized data acquisition unit. Gas production/consumption rates are measured with a delay of 80 s, the complete response to step changes in VCO2 or VO2 consumption being calculated over 15 min using the rate of change terms in the gas exchange equations. The total electrical power required for the whole system is 12 kW. The calorimeter has been functioning for nearly 4 years in a rural village of The Gambia during which ambient temperatures have ranged from 16 to 44 degrees C and dewpoints from -8 to 24 degrees C. The performance and accuracy of the calorimeter were tested using 20 per cent CO2 in N2 infusion and butane burning. Agreement between the theoretical and the measured values was found to be 99 per cent for VO2 and 100 per cent for VCO2 with a precision for both gases of +/- 10 ml/min over a 1-h period.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Recent data suggest that beta-blockers can be beneficial in subgroups of patients with chronic heart failure (CHF). For metoprolol and carvedilol, an increase in ejection fraction has been shown and favorable effects on the myocardial remodeling process have been reported in some studies. We examined the effects of bisoprolol fumarate on exercise capacity and left ventricular volume with magnetic resonance imaging (MRI) and applied a novel high-resolution MRI tagging technique to determine myocardial rotation and relaxation velocity. METHODS: Twenty-eight patients (mean age, 57 +/- 11 years; mean ejection fraction, 26 +/- 6%) were randomized to bisoprolol fumarate (n = 13) or to placebo therapy (n = 15). The dosage of the drugs was titrated to match that of the the Cardiac Insufficiency Bisoprolol Study protocol. Hemodynamic and gas exchange responses to exercise, MRI measurements of left ventricular end-systolic and end-diastolic volumes and ejection fraction, and left ventricular rotation and relaxation velocities were measured before the administration of the drug and 6 and 12 months later. RESULTS: After 1 year, heart rate was reduced in the bisoprolol fumarate group both at rest (81 +/- 12 before therapy versus 61 +/- 11 after therapy; P <.01) and peak exercise (144 +/- 20 before therapy versus 127 +/- 17 after therapy; P <.01), which indicated a reduction in sympathetic drive. No differences were observed in heart rate responses in the placebo group. No differences were observed within or between groups in peak oxygen uptake, although work rate achieved was higher (117.9 +/- 36 watts versus 146.1 +/- 33 watts; P <.05) and exercise time tended to be higher (9.1 +/- 1.7 minutes versus 11.4 +/- 2.8 minutes; P =.06) in the bisoprolol fumarate group. A trend for a reduction in left ventricular end-diastolic volume (-54 mL) and left ventricular end-systolic volume (-62 mL) in the bisoprolol fumarate group occurred after 1 year. Ejection fraction was higher in the bisoprolol fumarate group (25.0 +/- 7 versus 36.2 +/- 9%; P <.05), and the placebo group remained unchanged. Most changes in volume and ejection fraction occurred during the latter 6 months of treatment. With myocardial tagging, insignificant reductions in left ventricular rotation velocity were observed in both groups, whereas relaxation velocity was reduced only after bisoprolol fumarate therapy (by 39%; P <.05). CONCLUSION: One year of bisoprolol fumarate therapy resulted in an improvement in exercise capacity, showed trends for reductions in end-diastolic and end-systolic volumes, increased ejection fraction, and significantly reduced relaxation velocity. Although these results generally confirm the beneficial effects of beta-blockade in patients with chronic heart failure, they show differential effects on systolic and diastolic function.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study compares the effects of two short multiple-sprint exercise (MSE) (6 × 6 s) sessions with two different recovery durations (30 s or 180 s) on the slow component of oxygen uptake ([Formula: see text]O(2)) during subsequent high-intensity exercise. Ten male subjects performed a 6-min cycling test at 50% of the difference between the gas exchange threshold and [Formula: see text]O(2peak) (Δ50). Then, the subjects performed two MSEs of 6 × 6 s separated by two intersprint recoveries of 30 s (MSE(30)) and 180 s (MSE(180)), followed 10 min later by the Δ50 (Δ50(30) and Δ50(180), respectively). Electromyography (EMG) activities of the vastus medialis and lateralis were measured throughout each exercise bout. During MSE(30), muscle activity (root mean square) increased significantly (p ≤ 0.04), with a significant leftward-shifted median frequency of the power density spectrum (MDF; p ≤ 0.01), whereas MDF was significantly rightward-shifted during MSE(180) (p = 0.02). The mean [Formula: see text]O(2) value was significantly higher in MSE(30) than in MSE(180) (p < 0.001). During Δ50(30), [Formula: see text]O(2) and the deoxygenated hemoglobin ([HHb]) slow components were significantly reduced (-27%, p = 0.02, and -34%, p = 0.003, respectively) compared with Δ50. There were no significant modifications of the [Formula: see text]O(2) slow component in Δ50(180) compared with Δ50 (p = 0.32). The neuromuscular and metabolic adaptations during MSE(30) (preferential activation of type I muscle fibers evidenced by decreased MDF and a greater aerobic metabolism contribution to the required energy demands), but not during MSE(180), may lead to reduced [Formula: see text]O(2) and [HHb] slow components, suggesting an alteration in motor units recruitment profile (i.e., change in the type of muscle fibers recruited) and (or) an improved muscle O(2) delivery during subsequent exercise.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to compare O2 consumption (VO2) determination by the gas-exchange (VO2GE) and Fick (VO2F) methods in cardiac surgical patients. A total of 10 mechanically ventilated postoperative patients were studied prospectively. Thermodilution was performed using three randomly applied techniques: room temperature saline injected at end expiration, room temperature saline randomly injected in the respiratory cycle, and iced saline injected at end expiration. The influence of the number of thermodilution determinations was assessed by comparing results from 2 and 10 injections. The variability of VO2F was greater than that of VO2GE. There was no bias between VO2GE and VO2F values using injectate at room temperature. Accuracy and precision were not improved by increasing the number of cardiac output determinations from 2 to 10. A significant bias was observed using ice-cold injectate, VO2F being 18.0 +/- 15.4 ml/min/m2 lower than VO2GE (p = 0.001). Published results when comparing VO2F and VO2GE are discrepant. However, a significant bias was found in all studies using cold injectate, with lower VO2F values. We conclude that iced injectate should not be used to assess VO2 in critically ill patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To assess the effect of a fructose meal on resting energy expenditure (EE), indirect calorimetry was used in 23 women (10 lean and 13 obese) for 30 min before and 6 h after the ingestion of a mixed meal containing 20% protein, 33% fat, and either 75 g glucose or 75 g fructose as carbohydrate source (47%). Expressed as a percentage of the energy content of the meal, the thermogenic response to the fructose meal was significantly greater (10.2 +/- 0.5%) than that of the glucose meal (8.4 +/- 0.4%, P less than 0.01). This difference was still apparent when the lean and obese women were considered separately. The mean respiratory quotient during the 6-h postprandial period was significantly greater (P less than 0.01) for the fructose (0.85 +/- 0.01) than for the glucose meal (0.83 +/- 0.01) in the combined subjects. In addition, cumulative carbohydrate oxidation was significantly greater after the fructose than after the glucose meal (51.1 +/- 2.3 vs. 40.9 +/- 2.0 g/6 h, respectively, P less than 0.01). Only small changes were observed in postprandial plasma levels of glucose and insulin after the fructose meal, but the plasma levels of lactate increased more with fructose than with the glucose meal. These results suggest that there might be some advantages (higher thermogenesis and carbohydrate oxidations) in using fructose as part of the carbohydrate source in diet of people with obesity and/or insulin resistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

White micas in carbonate-rich tectonites and a few other rock types of large thrusts in the Swiss Helvetic fold-and-thrust belt have been analyzed by Ar-40/Ar-39 and Rb/Sr techniques to better constrain the timing of Alpine deformation for this region. Incremental Ar-40/Ar-39 heating experiments of 25 weakly metamorphosed (anchizone to low greenschist) samples yield plateau and staircase spectra. We interpret most of the staircase release spectra result from variable mixtures of syntectonic (neoformed) and detrital micas. The range in dates obtained within individual spectra depends primarily on the duration of mica nucleation and growth, and relative proportions of neoformed and detrital mica. Rb/Sr analyses of 12 samples yield dates of ca. 10-39 Ma (excluding one anomalously young sample). These dates are slightly younger than the Ar-40/Ar-39 total gas dates obtained for the same samples. The Rb/ Sr dates were calculated using initial Sr-87/Sr-86 ratios obtained from the carbonate-dominated host rocks, which are higher than normal Mesozoic carbonate values due to exchange with fluids of higher Sr-87/Sr-86 ratios (and lower O-18/O-16 ratios). Model dates calculated using Sr-87/Sr-86 values typical of Mesozoic marine carbonates more closely approximate the Ar-40/Ar-39 total gas dates for most of the samples. The similarities of Rb/Sr and Ar-40/Ar-39 total gas dates are consistent with limited amounts of detrital mica in the samples. The delta(18)O values range from 24-15%. (VSMOW) for 2-6 mum micas and 27-16parts per thousand for the carbonate host rocks. The carbonate values are significantly lower than their protolith values due to localized fluid-rock interaction and fluid flow along most thrust surfaces. Although most calcite-mica pairs are not in oxygen isotope equilibrium at temperatures of ca. 200-400 degreesC, their isotopic fractionations are indicative of either 1) partial exchange between the minerals and a common external fluid, or 2) growth or isotopic exchange of the mica with the carbonate after the carbonate had isotopically exchanged with an external fluid. The geological significance of these results is not easily or uniquely determined, and exemplifies the difficulties inherent in dating very fine-grained micas of highly deformed tectonites in low-grade metamorphic terranes. Two generalizations can be made regarding the dates obtained from the Helvetic thrusts: 1) samples from the two highest thrusts (Mt. Gond and Sublage) have all of their Ar-40/Ar-39 steps above 20 Ma, and 2) most samples from the deepest Helvetic thrusts have steps (often accounting for more than 80% of Ar-39 release) between 15 and 25 Ma. These dates are consistent with the order of thrusting in the foreland-imbricating system and increase proportions of neoformed to detrital mica in the more metamorphosed hinterland and deeply buried portions of the nappe pile. Individual thrusts accommodated the majority of their displacement during their initial incorporation into the foreland-imbricating system, and some thrusts remained active or were reactivated down to 15 Ma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gas chromatography (GC) is an analytical tool very useful to investigate the composition of gaseous mixtures. The different gases are separated by specific columns but, if hydrogen (H2 ) is present in the sample, its detection can be performed by a thermal conductivity detector or a helium ionization detector. Indeed, coupled to GC, no other detector can perform this detection except the expensive atomic emission detector. Based on the detection and analysis of H2 isotopes by low-pressure chemical ionization mass spectrometry (MS), a new method for H2 detection by GC coupled to MS with an electron ionization ion source and a quadrupole analyser is presented. The presence of H2 in a gaseous mixture could easily be put in evidence by the monitoring of the molecular ion of the protonated carrier gas. Copyright © 2013 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Drug abuse is a widespread problem affecting both teenagers and adults. Nitrous oxide is becoming increasingly popular as an inhalation drug, causing harmful neurological and hematological effects. Some gas chromatography-mass spectrometry (GC-MS) methods for nitrous oxide measurement have been previously described. The main drawbacks of these methods include a lack of sensitivity for forensic applications; including an inability to quantitatively determine the concentration of gas present. The following study provides a validated method using HS-GC-MS which incorporates hydrogen sulfide as a suitable internal standard allowing the quantification of nitrous oxide. Upon analysis, sample and internal standard have similar retention times and are eluted quickly from the molecular sieve 5Å PLOT capillary column and the Porabond Q column therefore providing rapid data collection whilst preserving well defined peaks. After validation, the method has been applied to a real case of N2O intoxication indicating concentrations in a mono-intoxication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Furosemide (FD: Lasix) is a loop diuretic which strongly increases both urine flow and electrolyte urinary excretion. Healthy volunteers were administered 40 mg orally (dissolved in water) and concentrations of FD were determined in serum and urine for up to 6 h for eight subjects, who absorbed water at a rate of 400 ml/h. Quantification was performed by HPLC with fluorescence detection (excitation at 233 nm, emission at 389 nm) with a limit of detection of 5 ng/ml for a 300-microliters sample. The elution of FD was completed within 4 min using a gradient of acetonitrile concentration rising from 30 to 50% in 0.08 M phosphoric acid. The delay to the peak serum concentration ranged from 60 to 120 min. FD was still easily measurable in the sera from all subjects 6 h after administration. In urine, the excretion rates reached their maximum between 1 and 3 h. The total amount of FD excreted in the urine averaged 11.2 mg (range 7.6-14.0 mg), with a mean urine volume of 3024 ml (range 2620-3596 ml). Moreover, the urine density was lower than 1.010 (recommended as an upper limit in doping analysis to screen diuretics) only for 2 h. An additional volunteer was administered 40 mg of FD and his urine was collected over a longer period. FD was still detectable 48 h after intake. Gas chromatography-mass spectrometry with different types of ionization was used to confirm the occurrence of FD after permethylation of the extract. Negative-ion chemical ionization, with ammonia as reactant gas, was found to be the most sensitive method of detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel approach to measure carbon dioxide (CO2) in gaseous samples, based on a precise and accurate quantification by (13)CO2 internal standard generated in situ is presented. The main goal of this study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable in the routine determination of CO2. The main drawback of the GC methods discussed in the literature for CO2 measurement is the lack of a specific internal standard necessary to perform quantification. CO2 measurement is still quantified by external calibration without taking into account analytical problems which can often occur considering gaseous samples. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in situ an internal labeled standard gas ((13)CO2) on the basis of the stoichiometric formation of CO2 by the reaction of hydrochloric acid (HCl) with sodium hydrogen carbonate (NaH(13)CO3). This method allows a precise measurement of CO2 concentration and was validated on various human postmortem gas samples in order to study its efficiency.