58 resultados para Free Software
Resumo:
Coltop3D is a software that performs structural analysis by using digital elevation model (DEM) and 3D point clouds acquired with terrestrial laser scanners. A color representation merging slope aspect and slope angle is used in order to obtain a unique code of color for each orientation of a local slope. Thus a continuous planar structure appears in a unique color. Several tools are included to create stereonets, to draw traces of discontinuities, or to compute automatically density stereonet. Examples are shown to demonstrate the efficiency of the method.
Resumo:
The distribution of free and liposomal doxorubicin (Liporubicin) administered by intravenous injection (IV) or isolated lung perfusion (ILP) was compared in normal and tumor tissues of sarcoma bearing rodent lungs. A single sarcomatous tumor was generated in the left lung of 35 Fischer rats, followed 10 days later by left-sided ILP (n=20) or IV drug administration (n=12), using 100 microg and 400 microg free or liposomal doxorubicin, respectively. The tumor and lung tissue drug concentration was measured by HPLC. Free doxorubicin administered by ILP resulted in a three-fold (100 microg) and 10-fold (400 microg) increase of the drug concentration in the tumor and normal lung tissue compared to IV administration. In contrast, ILP with Liporubicin resulted in a similar drug uptake in the tumor and lung tissue compared to IV injection. For both drug formulations and dosages, ILP resulted in a higher tumor to lung tissue drug ratio but also in a higher spatial heterogeneity of drug distribution within the lung compared to IV administration. ILP resulted in a higher tumor to lung tissue drug ratio and in a more heterogeneous drug distribution within the lung compared to IV drug administration.
Resumo:
Microautophagy is the direct uptake of soluble or particulate cellular constituents into lysosomes. Here, I describe methods to reconstitute and study this process in vitro, using vacuoles (lysosomes) from the yeast Saccharomyces cerevisiae as model organelles. Protocols to grow the cells, isolate vacuoles from them, and to induce microautophagy of soluble tracers are presented.
Resumo:
The purpose of this study was to prospectively compare free-breathing navigator-gated cardiac-triggered three-dimensional steady-state free precession (SSFP) spin-labeling coronary magnetic resonance (MR) angiography performed by using Cartesian k-space sampling with that performed by using radial k-space sampling. A new dedicated placement of the two-dimensional selective labeling pulse and an individually adjusted labeling delay time approved by the institutional review board were used. In 14 volunteers (eight men, six women; mean age, 28.8 years) who gave informed consent, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, vessel length, and subjective image quality were investigated. Differences between groups were analyzed with nonparametric tests (Wilcoxon, Pearson chi2). Radial imaging, as compared with Cartesian imaging, resulted in a significant reduction in the severity of motion artifacts, as well as an increase in SNR (26.9 vs 12.0, P < .05) in the coronary arteries and CNR (23.1 vs 8.8, P < .05) between the coronary arteries and the myocardium. A tendency toward improved vessel sharpness and vessel length was also found with radial imaging. Radial SSFP imaging is a promising technique for spin-labeling coronary MR angiography.
Resumo:
Black-blood fast spin-echo imaging is a powerful technique for the evaluation of cardiac anatomy. To avoid fold-over artifacts, using a sufficiently large field of view in phase-encoding direction is mandatory. The related oversampling affects scanning time and respiratory chest motion artifacts are commonly observed. The excitation of a volume that exclusively includes the heart without its surrounding structures may help to improve scan efficiency and minimize motion artifacts. Therefore, and by building on previously reported inner-volume approach, the combination of a black-blood fast spin-echo sequence with a two-dimensionally selective radiofrequency pulse is proposed for selective "local excitation" small field of view imaging of the heart. This local excitation technique has been developed, implemented, and tested in phantoms and in vivo. With this method, small field of view imaging of a user-specified region in the human thorax is feasible, scanning becomes more time efficient, motion artifacts can be minimized, and additional flexibility in the choice of imaging parameters can be exploited.
Resumo:
Recognition by the T-cell receptor (TCR) of immunogenic peptides (p) presented by Class I major histocompatibility complexes (MHC) is the key event in the immune response against virus-infected cells or tumor cells. A study of the 2C TCR/SIYR/H-2K(b) system using a computational alanine scanning and a much faster binding free energy decomposition based on the Molecular Mechanics-Generalized Born Surface Area (MM-GBSA) method is presented. The results show that the TCR-p-MHC binding free energy decomposition using this approach and including entropic terms provides a detailed and reliable description of the interactions between the molecules at an atomistic level. Comparison of the decomposition results with experimentally determined activity differences for alanine mutants yields a correlation of 0.67 when the entropy is neglected and 0.72 when the entropy is taken into account. Similarly, comparison of experimental activities with variations in binding free energies determined by computational alanine scanning yields correlations of 0.72 and 0.74 when the entropy is neglected or taken into account, respectively. Some key interactions for the TCR-p-MHC binding are analyzed and some possible side chains replacements are proposed in the context of TCR protein engineering. In addition, a comparison of the two theoretical approaches for estimating the role of each side chain in the complexation is given, and a new ad hoc approach to decompose the vibrational entropy term into atomic contributions, the linear decomposition of the vibrational entropy (LDVE), is introduced. The latter allows the rapid calculation of the entropic contribution of interesting side chains to the binding. This new method is based on the idea that the most important contributions to the vibrational entropy of a molecule originate from residues that contribute most to the vibrational amplitude of the normal modes. The LDVE approach is shown to provide results very similar to those of the exact but highly computationally demanding method.
Resumo:
Free-living amoebae constitute reservoirs for many bacteria including not only well-known pathogens but also emerging pathogens responsible for respiratory diseases, and contribute to the protection, survival and dissemination of these bacteria in water systems, despite the application of disinfection or thermal treatments. In this article we review the available information on the presence of free-living amoebae and amoebae-resisting bacteria in drinking water systems, on the factors that contribute to their presence in the water and/or the biofilms, on the possible control measures and their effectiveness, and we identify some gaps in current knowledge needing further research.
Resumo:
PURPOSE: To determine the diagnostic value of the intravascular contrast agent gadocoletic acid (B-22956) in three-dimensional, free breathing coronary magnetic resonance angiography (MRA) for stenosis detection in patients with suspected or known coronary artery disease. METHODS: Eighteen patients underwent three-dimensional, free breathing coronary MRA of the left and right coronary system before and after intravenous application of a single dose of gadocoletic acid (B-22956) using three different dose regimens (group A 0.050 mmol/kg; group B 0.075 mmol/kg; group C 0.100 mmol/kg). Precontrast scanning followed a coronary MRA standard non-contrast T2 preparation/turbo-gradient echo sequence (T2Prep); for postcontrast scanning an inversion-recovery gradient echo sequence was used (real-time navigator correction for both scans). In pre- and postcontrast scans quantitative analysis of coronary MRA data was performed to determine the number of visible side branches, vessel length and vessel sharpness of each of the three coronary arteries (LAD, LCX, RCA). The number of assessable coronary artery segments was determined to calculate sensitivity and specificity for detection of stenosis > or = 50% on a segment-to-segment basis (16-segment-model) in pre- and postcontrast scans with x-ray coronary angiography as the standard of reference. RESULTS: Dose group B (0.075 mmol/kg) was preferable with regard to improvement of MR angiographic parameters: in postcontrast scans all MR angiographic parameters increased significantly except for the number of visible side branches of the left circumflex artery. In addition, assessability of coronary artery segments significantly improved postcontrast in this dose group (67 versus 88%, p < 0.01). Diagnostic performance (sensitivity, specificity, accuracy) was 83, 77 and 78% for precontrast and 86, 95 and 94% for postcontrast scans. CONCLUSIONS: The use of gadocoletic acid (B-22956) results in an improvement of MR angiographic parameters, asssessability of coronary segments and detection of coronary stenoses > or = 50%.
Resumo:
At least 10% of glioblastoma relapses occur at distant and even contralateral locations. This disseminated growth limits surgical intervention and contributes to neurological morbidity. Preclinical data pointed toward a role for temozolomide (TMZ) in reducing radiotherapy-induced glioma cell invasiveness. Our objective was to develop and validate a new analysis tool of MRI data to examine the clinical recurrence pattern of glioblastomas. MRIcro software was used to map the location and extent of initial preoperative and recurrent tumors on MRI of 63 patients in the European Organisation for Research and Treatment of Cancer (EORTC) 26981/22981/National Cancer Institute of Canada (NCIC) CE.3 study into the same stereotaxic space. This allowed us to examine changes of site and distance between the initial and the recurrent tumor on the group level. Thirty of the 63 patients were treated using radiotherapy, while the other patients completed a radiotherapy-plus-TMZ treatment. Baseline characteristics (median age, KPS) and outcome data (progression-free survival, overall survival) of the patients included in this analysis resemble those of the general study cohort. The patient groups did not differ in the promoter methylation status of methyl guanine methyltransferase (MGMT). Overall frequency of distant recurrences was 20%. Analysis of recurrence patterns revealed no difference between the groups in the size of the recurrent tumor or in the differential effect on the distance of the recurrences from the preoperative tumor location. The data show the feasibility of groupwise recurrence pattern analysis. An effect of TMZ treatment on the recurrence pattern in the EORTC 26981/22981/NCIC CE.3 study could not be demonstrated.
Resumo:
The MyHits web server (http://myhits.isb-sib.ch) is a new integrated service dedicated to the annotation of protein sequences and to the analysis of their domains and signatures. Guest users can use the system anonymously, with full access to (i) standard bioinformatics programs (e.g. PSI-BLAST, ClustalW, T-Coffee, Jalview); (ii) a large number of protein sequence databases, including standard (Swiss-Prot, TrEMBL) and locally developed databases (splice variants); (iii) databases of protein motifs (Prosite, Interpro); (iv) a precomputed list of matches ('hits') between the sequence and motif databases. All databases are updated on a weekly basis and the hit list is kept up to date incrementally. The MyHits server also includes a new collection of tools to generate graphical representations of pairwise and multiple sequence alignments including their annotated features. Free registration enables users to upload their own sequences and motifs to private databases. These are then made available through the same web interface and the same set of analytical tools. Registered users can manage their own sequences and annotations using only web tools and freeze their data in their private database for publication purposes.
Resumo:
RATIONALE AND OBJECTIVES: Recent developments of MR imaging equipment enabled high-quality steady state-free-precession (Balanced FFE, True-FISP) MR-imaging with a substantial 'T2 like' contrast, resulting in a high signal intensity of the blood-pool without the application of exogenous contrast agents. It is hypothesized that Balanced-FFE may be valuable for contrast enhancement in 3D free-breathing coronary MRA. MATERIALS AND METHODS: Navigator-gated free-breathing cardiac triggered coronary MRA was performed in 10 healthy adult subjects and three patients with radiograph defined coronary artery disease using a segmented k-space 3D Balanced FFE imaging sequence. RESULTS: High contrast-to-noise ratio between the blood-pool and the myocardium (29 +/- 8) and long segment visualization of both coronary arteries could be obtained in about 5 minutes during free breathing using the present navigator-gated Balanced-FFE coronary MRA approach. First patient results demonstrated successful display of coronary artery stenoses. CONCLUSION: Balanced FFE offers a potential alternative for endogenous contrast enhancement in navigator-gated free-breathing 3D coronary MRA. The obtained results together with the relatively short scanning time warrant further studies in larger patient collectives.