93 resultados para Eye--Anatomy
Resumo:
BACKGROUND: Medialization of the cup with a respective increase in femoral offset has been proposed in THA to increase abductor moment arms. Insofar as there are potential disadvantages to cup medialization, it is important to ascertain whether the purported biomechanical benefits of cup medialization are large enough to warrant the downsides; to date, studies regarding this question have disagreed. QUESTIONS/PURPOSES: The purpose of this study was to quantify the effect of cup medialization with a compensatory increase in femoral offset compared with anatomic reconstruction for patients undergoing THA. We tested the hypothesis that there is a (linear) correlation between preoperative anatomic parameters and muscle moment arm increase caused by cup medialization. METHODS: Fifteen patients undergoing THA were selected, covering a typical range of preoperative femoral offsets. For each patient, a finite element model was built based on a preoperative CT scan. The model included the pelvis, femur, gluteus minimus, medius, and maximus. Two reconstructions were compared: (1) anatomic position of the acetabular center of rotation, and (2) cup medialization compensated by an increase in the femoral offset. Passive abduction-adduction and flexion-extension were simulated in the range of normal gait. Muscle moment arms were evaluated and correlated to preoperative femoral offset, acetabular offset, height of the greater trochanter (relative to femoral center of rotation), and femoral antetorsion angle. RESULTS: The increase of muscle moment arms caused by cup medialization varied among patients. Muscle moment arms increase by 10% to 85% of the amount of cup medialization for abduction-adduction and from -35% (decrease) to 50% for flexion-extension. The change in moment arm was inversely correlated (R(2) = 0.588, p = 0.001) to femoral antetorsion (anteversion), such that patients with less femoral antetorsion gained more in terms of hip muscle moments. No linear correlation was observed between changes in moment arm and other preoperative parameters in this series. CONCLUSIONS: The benefit of cup medialization is variable and depends on the individual anatomy. CLINICAL RELEVANCE: Cup medialization with compensatory increase of the femoral offset may be particularly effective in patients with less femoral antetorsion. However, cup medialization must be balanced against its tradeoffs, including the additional loss of medial acetabular bone stock, and eventual proprioceptive implications of the nonanatomic center of rotation and perhaps joint reaction forces. Clinical studies should better determine the relevance of small changes of moment arms on function and joint reaction forces.
Resumo:
The vision-for-action literature favours the idea that the motor output of an action - whether manual or oculomotor - leads to similar results regarding object handling. Findings on line bisection performance challenge this idea: healthy individuals bisect lines manually to the left of centre, and to the right of centre when using eye fixation. In case that these opposite biases for manual and oculomotor action reflect more universal compensatory mechanisms that cancel each other out to enhance overall accuracy, one would like to observe comparable opposite biases for other material. In the present study, we report on three independent experiments in which we tested line bisection (by hand, by eye fixation) not only for solid lines, but also for letter lines; the latter, when bisected manually, is known to result in a rightward bias. Accordingly, we expected a leftward bias for letter lines when bisected via eye fixation. Analysis of bisection biases provided evidence for this idea: manual bisection was more rightward for letter as compared to solid lines, while bisection by eye fixation was more leftward for letter as compared to solid lines. Support for the eye fixation observation was particularly obvious in two of the three studies, for which comparability between eye and hand action was increasingly adjusted (paper-pencil versus touch screen for manual action). These findings question the assumption that ocular motor and manual output are always inter-changeable, but rather suggest that at least for some situations ocular motor and manual output biases are orthogonal to each other, possibly balancing each other out.
Resumo:
A questionnaire was developed by the members of WG12 of EURADOS in order to establish an overview of the current status of eye lens radiation dose monitoring in hospitals. The questionnaire was sent to medical physicists and radiation protection officers in hospitals across Europe. Specific topics were addressed in the questionnaire such as: knowledge of the proposed eye lens dose limit; monitoring and dosimetry issues; training and radiation protection measures. The results of the survey highlighted that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens protection is crucial. Personnel should be properly trained in how to use protective equipment in order to keep eye lens doses as low as reasonably achievable. Finally, the results also highlighted the need to improve the design of eye dosemeters in order to ensure satisfactory use by workers.
Resumo:
Cyclosporine A (CsA) has been demonstrated to be effective for the treatment of a variety of ophthalmological conditions, including ocular surface disorders such as the dry eye disease (DED). Since CsA is characterised by its low water solubility, the development of a topical ophthalmic formulation represents an interesting pharmaceutical question. In the present study, two different strategies to address this challenge were studied and compared: (i) a water-soluble CsA prodrug formulated within an aqueous solution and (ii) a CsA oil-in-water emulsion (Restasis, Allergan Inc., Irvine, CA). First, the prodrug formulation was shown to have an excellent ocular tolerance as well as no influence on the basal tear production; maintaining the ocular surface properties remained unchanged. Then, in order to allow in vivo investigations, a specific analytical method based on ultra high pressure liquid chromatography coupled with triple quadrupole mass spectrometer (UHPLC-MS/MS) was developed and optimised to quantify CsA in ocular tissues and fluids. The CsA ocular kinetics in lachrymal fluid for both formulations were found to be similar between 15 min and 48 h. The CsA ocular distribution study evidenced the ability of the prodrug formulation to penetrate into the eye, achieving therapeutically active CsA levels in tissues of both the anterior and posterior segments. In addition, the detailed analysis of the in vivo data using a bicompartmental model pointed out a higher bioavailability and lower elimination rate for CsA when it is generated from the prodrug than after direct application as an emulsion. The interesting in vivo properties displayed by the prodrug solution make it a safe and suitable option for the treatment of DED.
Resumo:
A precise knowledge of arterial, portal, hepatic and biliary anatomical variations is mandatory when a liver intervention is planned. However, only certain variations must be searched when a precise intervention is planned. The basic liver anatomy as well as the most relevant malformations will be precised.
Resumo:
Ophthalmologists typically acquire different image modalities to diagnose eye pathologies. They comprise, e.g., Fundus photography, optical coherence tomography, computed tomography, and magnetic resonance imaging (MRI). Yet, these images are often complementary and do express the same pathologies in a different way. Some pathologies are only visible in a particular modality. Thus, it is beneficial for the ophthalmologist to have these modalities fused into a single patient-specific model. The goal of this paper is a fusion of Fundus photography with segmented MRI volumes. This adds information to MRI that was not visible before like vessels and the macula. This paper contributions include automatic detection of the optic disc, the fovea, the optic axis, and an automatic segmentation of the vitreous humor of the eye.
Resumo:
There are various methods of providing pain relief for painful blind eyes. We wish to recommend this effective method of providing temporary analgesia in patients suffering from a severe painful blind eye before undergoing enucleation.
Resumo:
OBJECTIVE: Patients with intractable epilepsy due to extensive lesions involving the posterior quadrant (temporal, parietal, and occipital lobes) form a small subset of epilepsy surgery. This study was done with a view to analyze our experience with this group of patients and to define the changes in the surgical technique over the last 15 years. We also describe the microsurgical technique of the different surgical variants used, along with their functional neuroanatomy. METHODS: In this series there were 13 patients with a median age of 17 years. All patients had extensive presurgical evaluation that provided concordant evidence localizing the lesion and seizure focus to the posterior quadrant. The objective of the surgery was to eliminate the effect of the epileptogenic tissue and preserve motor and sensory functions. RESULTS: During the course of this study period of 15 years, the surgical procedure performed evolved toward incorporating more techniques of disconnection and minimizing resection. Three technical variants were thus utilized in this series, namely, (i) anatomical posterior quadrantectomy (APQ), (ii) functional posterior quadrantectomy (FPQ), and (iii) periinsular posterior quadrantectomy (PIPQ). After a median follow-up period of 6 years, 12/13 patients had Engel's Class I seizure outcome. CONCLUSION: The results of surgery for posterior quadrantic epilepsy have yielded excellent seizure outcomes in 92% of the patients in the series with no mortality or major morbidity. The incorporation of disconnective techniques in multilobar surgery has maintained the excellent results obtained earlier with resective surgery.
Resumo:
A significant postoperative problem in patients undergoing excision of intramedullary tumors is painful dysesthesiae, attributed to various causes, including edema, arachnoid scarring and cord tethering. The authors describe a technique of welding the pia and arachnoid after the excision of intramedullary spinal cord tumors used in seven cases. Using a fine bipolar forcep and a low current, the pial edges of the myelotomy were brought together and welded under saline irrigation. A similar method was used for closing the arachnoid while the dura was closed with a running 5-0 vicryl suture. Closing the pia and arachnoid restores normal cord anatomy after tumor excision and may reduce the incidence of postoperative painful dysesthesiae.
Resumo:
PURPOSE: To evaluate the effect of intraocular administration of nitric oxide (NO) donors in the rabbit eye on intraocular pressure (IOP), inflammation, and toxicity. METHODS: Intravitreal and intracameral injections of two NO donors, SIN-1 and SNAP, and SIN-1C and BSS were performed. Clinical examination, IOP measurements, protein evaluation in aqueous humor, and histologic analysis of the ocular globes were realized. Nitric oxide release was demonstrated by nitrite production in the aqueous humor and in the vitreous using the Griess reaction. RESULTS: The drastic decrease of IOP, observed after a single NO donor injection, was correlated directly with nitrite production and, thus, to NO release. Injection of inactive metabolite of SIN-1, SIN-1C, which is not able to release NO, did not modulate IOP. When administered in the aqueous humor or in the vitreous, NO did not diffuse from one segment of the eye to another. No inflammation or histologic damage was observed as a result of a single NO donor administration. CONCLUSIONS: Nitric oxide is implicated directly in the regulation of IOP and its acute, and massive release into the rabbit eye did not induce inflammation or other growth toxic effects on the ocular tissues.
Resumo:
PURPOSE: To characterize in detail the phenotype of five unrelated families with autosomal dominant bull's eye maculopathy (BEM) due to the R373C mutation in the PROM1 gene. METHODS: Forty-one individuals of five families of Caribbean (family A), British (families B, D, E), and Italian (family C) origin, segregating the R373C mutation in PROM1, were ascertained. Electrophysiological assessment, fundus autofluorescence (FAF) imaging, fundus fluorescein angiography (FFA), and optical coherence tomography (OCT) were performed in available subjects. Mutation screening of PROM1 was performed. RESULTS: The R373C mutant was present heterozygously in all affected patients. The age at onset was variable and ranged between 9 and 58 years, with most of the individuals presenting with reading difficulties. Subjects commonly had a mild to moderate reduction in visual acuity except for members of family C who experienced markedly reduced central vision. The retinal phenotype was characterized by macular dystrophy, with retinal pigment epithelial mottling in younger subjects, progressing to typical BEM over time, with the development of macular atrophy in older patients. In addition, all members of family C had typical features of RP. The electrophysiological findings were variable both within and between families. CONCLUSIONS: Mutations in PROM1 have been described to cause a severe form of autosomal recessive RP in two families of Indian and Pakistani descent. The results of this study have demonstrated that a distinct redundant PROM1 mutation (R373C) can also produce an autosomal dominant, fully penetrant retinopathy, characterized by BEM with little inter- and intrafamilial variability, and retinal dystrophy with variable rod or rod-cone dysfunction and marked intra- and interfamilial variability, ranging from isolated maculopathy without generalized photoreceptor dysfunction to maculopathy associated with very severe rod-cone dysfunction.
Resumo:
Splenic arterial interventions are increasingly performed to treat various clinical conditions, including abdominal trauma, hypersplenism, splenic arterial aneurysm, portal hypertension, and splenic neoplasm. When clinically appropriate, these procedures may provide an alternative to open surgery. They may help to salvage splenic function in patients with posttraumatic injuries or hypersplenism and to improve hematologic parameters in those who otherwise would be unable to undergo high-dose chemotherapy or immunosuppressive therapy. Splenic arterial interventions also may be performed to exclude splenic artery aneurysms from the parent vessel lumen and prevent aneurysm rupture; to reduce portal pressure and prevent sequelae in patients with portal hypertension; to treat splenic artery steal syndrome and improve liver perfusion in liver transplant recipients; and to administer targeted treatment to areas of neoplastic disease in the splenic parenchyma. As the use of splenic arterial interventions increases in interventional radiology practice, clinicians must be familiar with the splenic vascular anatomy, the indications and contraindications for performing interventional procedures, the technical considerations involved, and the potential use of other interventional procedures, such as radiofrequency ablation, in combination with splenic arterial interventions. Familiarity with the complications that can result from these interventional procedures, including abscess formation and pancreatitis, also is important.