55 resultados para Empirical Mode Decomposition, vibration-based analysis, damage detection, signal decomposition
Resumo:
This study describes the validation of a new wearable system for assessment of 3D spatial parameters of gait. The new method is based on the detection of temporal parameters, coupled to optimized fusion and de-drifted integration of inertial signals. Composed of two wirelesses inertial modules attached on feet, the system provides stride length, stride velocity, foot clearance, and turning angle parameters at each gait cycle, based on the computation of 3D foot kinematics. Accuracy and precision of the proposed system were compared to an optical motion capture system as reference. Its repeatability across measurements (test-retest reliability) was also evaluated. Measurements were performed in 10 young (mean age 26.1±2.8 years) and 10 elderly volunteers (mean age 71.6±4.6 years) who were asked to perform U-shaped and 8-shaped walking trials, and then a 6-min walking test (6MWT). A total of 974 gait cycles were used to compare gait parameters with the reference system. Mean accuracy±precision was 1.5±6.8cm for stride length, 1.4±5.6cm/s for stride velocity, 1.9±2.0cm for foot clearance, and 1.6±6.1° for turning angle. Difference in gait performance was observed between young and elderly volunteers during the 6MWT particularly in foot clearance. The proposed method allows to analyze various aspects of gait, including turns, gait initiation and termination, or inter-cycle variability. The system is lightweight, easy to wear and use, and suitable for clinical application requiring objective evaluation of gait outside of the lab environment.
Resumo:
PURPOSE: Corticosteroids have recorded beneficial clinical effects and are widely used in medicine. In ophthalmology, besides their treatment benefits, side effects, including ocular toxicity have been observed especially when intraocular delivery is used. The mechanism of these toxic events remains, however, poorly understood. In our present study, we investigated the mechanisms and potential pathways of corticosteroid-induced retinal cell death. METHODS: Rats were sacrificed 24 h and 8 days after an intravitreous injection of 1 microl (40 microg) of Kenacort Retard. The eyes were processed for ultra structure analysis and detection of activated caspase-3, cytochrome-C, apoptosis-inducing factor (AIF), LEI-L-Dnase II, terminal transferase dUTP nick end labeling (TUNEL), and microtubule-associated protein 1-light chain 3 (MAP-LC3). In vitro, rat retinal pigment epithelial cells (RPE), retinal Müller glial cells (RMG) and human ARPE-19 cells were treated with triamcinolone acetonide (TA) or other glucocorticoids. Cell viability was quantified by 3-(4,5-dimethylthiazol-2-yl)-2,5 phenyltetrazolium bromide test (MTT) assay and cell counts. Nuclei staining, TUNEL assay, annexin-V binding, activated caspase-3 and lactate dehydrogenase (LDH) production characterized cell death. Localization of cytochrome-C, AIF, LEI-and L-Dnase II, and staining with MAP-LC3 or monodansylcadaverine were also carried out. Finally, ARPE-19 cells transfected with AIP-1/Alix were exposed to TA. RESULTS: In vitro incubation of retinal cell in the presence of corticosteroids induced a specific and dose-dependent reduction of cell viability. These toxic events were not associated with the anti-inflammatory activity of these compounds but depended on the hydro solubility of their formulation. Before cell death, extensive cytoplasmic vacuolization was observed in the retinal pigment epithelial (RPE) cells in vivo and in vitro. The cells however, did not show known caspase-dependent or caspase-independent apoptotic reactions. These intracellular vacuoles were negative for MAP-LC3 but some stained positive for monodansylcadaverine. Furthermore, over expression of AIP-1/Alix inhibited RPE cell death. CONCLUSIONS: These observations suggest that corticosteroid-induced retinal cell death may be carried out mainly through a paraptosis pathway.
Resumo:
BACKGROUND: Atrial arrhythmias increase disease burden in the general adult population. Adults with congenital heart lesions constitute a rapidly growing group of patients with cardiovascular disease. We hypothesized that atrial arrhythmias increase with age and impair health outcomes in this population. METHODS AND RESULTS: We conducted a population-based analysis of prevalence, lifetime risk, mortality, and morbidity associated with atrial arrhythmias in adults with congenital heart disease from l983 to 2005. In 38 428 adults with congenital heart disease in 2005, 5812 had atrial arrhythmias. Overall, the 20-year risk of developing atrial arrhythmia was 7% in a 20-year-old subject and 38% in a 50-year-old subject. More than 50% of patients with severe congenital heart disease reaching age 18 years developed atrial arrhythmias by age 65 years. In patients with congenital heart disease, the hazard ratio of any adverse event in those with atrial arrhythmias compared with those without was 2.50 (95% confidence interval, 2.38 to 2.62; P<0.0001), with a near 50% increase in mortality (hazard ratio, 1.47; 95% confidence interval, 1.37 to 1.58; P<0.001), more than double the risk of morbidity (stroke or heart failure) (hazard ratio, 2.21; 95% confidence interval, 2.07 to 2.36; P<0.001), and 3 times the risk of cardiac interventions (hazard ratio, 3.00; 95% confidence interval, 2.81 to 3.20; P<0.001). CONCLUSIONS: Atrial arrhythmias occurred in 15% of adults with congenital heart disease. The lifetime incidence increased steadily with age and was associated with a doubling of the risk of adverse events. An increase in resource allocation should be anticipated to deal with this increasing burden.
Resumo:
Summary : Forensic science - both as a source of and as a remedy for error potentially leading to judicial error - has been studied empirically in this research. A comprehensive literature review, experimental tests on the influence of observational biases in fingermark comparison, and semistructured interviews with heads of forensic science laboratories/units in Switzerland and abroad were the tools used. For the literature review, some of the areas studied are: the quality of forensic science work in general, the complex interaction between science and law, and specific propositions as to error sources not directly related to the interaction between law and science. A list of potential error sources all the way from the crime scene to the writing of the report has been established as well. For the empirical tests, the ACE-V (Analysis, Comparison, Evaluation, and Verification) process of fingermark comparison was selected as an area of special interest for the study of observational biases, due to its heavy reliance on visual observation and recent cases of misidentifications. Results of the tests performed with forensic science students tend to show that decision-making stages are the most vulnerable to stimuli inducing observational biases. For the semi-structured interviews, eleven senior forensic scientists answered questions on several subjects, for example on potential and existing error sources in their work, of the limitations of what can be done with forensic science, and of the possibilities and tools to minimise errors. Training and education to augment the quality of forensic science have been discussed together with possible solutions to minimise the risk of errors in forensic science. In addition, the time that samples of physical evidence are kept has been determined as well. Results tend to show considerable agreement on most subjects among the international participants. Their opinions on possible explanations for the occurrence of such problems and the relative weight of such errors in the three stages of crime scene, laboratory, and report writing, disagree, however, with opinions widely represented in existing literature. Through the present research it was therefore possible to obtain a better view of the interaction of forensic science and judicial error to propose practical recommendations to minimise their occurrence. Résumé : Les sciences forensiques - considérés aussi bien comme source de que comme remède à l'erreur judiciaire - ont été étudiées empiriquement dans cette recherche. Une revue complète de littérature, des tests expérimentaux sur l'influence du biais de l'observation dans l'individualisation de traces digitales et des entretiens semi-directifs avec des responsables de laboratoires et unités de sciences forensiques en Suisse et à l'étranger étaient les outils utilisés. Pour la revue de littérature, quelques éléments étudies comprennent: la qualité du travail en sciences forensiques en général, l'interaction complexe entre la science et le droit, et des propositions spécifiques quant aux sources d'erreur pas directement liées à l'interaction entre droit et science. Une liste des sources potentielles d'erreur tout le long du processus de la scène de crime à la rédaction du rapport a également été établie. Pour les tests empiriques, le processus d'ACE-V (analyse, comparaison, évaluation et vérification) de l'individualisation de traces digitales a été choisi comme un sujet d'intérêt spécial pour l'étude des effets d'observation, due à son fort recours à l'observation visuelle et dû à des cas récents d'identification erronée. Les résultats des tests avec des étudiants tendent à prouver que les étapes de prise de décision sont les plus vulnérables aux stimuli induisant des biais d'observation. Pour les entretiens semi-structurés, onze forensiciens ont répondu à des questions sur des sujets variés, par exemple sur des sources potentielles et existantes d'erreur dans leur travail, des limitations de ce qui peut être fait en sciences forensiques, et des possibilités et des outils pour réduire au minimum ses erreurs. La formation et l'éducation pour augmenter la qualité des sciences forensiques ont été discutées ainsi que les solutions possibles pour réduire au minimum le risque d'erreurs en sciences forensiques. Le temps que des échantillons sont gardés a été également déterminé. En général, les résultats tendent à montrer un grand accord sur la plupart des sujets abordés pour les divers participants internationaux. Leur avis sur des explications possibles pour l'occurrence de tels problèmes et sur le poids relatif de telles erreurs dans les trois étapes scène de crime;', laboratoire et rédaction de rapports est cependant en désaccord avec les avis largement représentés dans la littérature existante. Par cette recherche il était donc possible d'obtenir une meilleure vue de l'interaction des sciences forensiques et de l'erreur judiciaire afin de proposer des recommandations pratiques pour réduire au minimum leur occurrence. Zusammenfassung : Forensische Wissenschaften - als Ursache und als Hilfsmittel gegen Fehler, die möglicherweise zu Justizirrtümern führen könnten - sind hier empirisch erforscht worden. Die eingestzten Methoden waren eine Literaturübersicht, experimentelle Tests über den Einfluss von Beobachtungseffekten (observer bias) in der Individualisierung von Fingerabdrücken und halbstandardisierte Interviews mit Verantwortlichen von kriminalistischen Labors/Diensten in der Schweiz und im Ausland. Der Literaturüberblick umfasst unter anderem: die Qualität der kriminalistischen Arbeit im Allgemeinen, die komplizierte Interaktion zwischen Wissenschaft und Recht und spezifische Fehlerquellen, welche nicht direkt auf der Interaktion von Recht und Wissenschaft beruhen. Eine Liste möglicher Fehlerquellen vom Tatort zum Rapportschreiben ist zudem erstellt worden. Für die empirischen Tests wurde der ACE-V (Analyse, Vergleich, Auswertung und Überprüfung) Prozess in der Fingerabdruck-Individualisierung als speziell interessantes Fachgebiet für die Studie von Beobachtungseffekten gewählt. Gründe sind die Wichtigkeit von visuellen Beobachtungen und kürzliche Fälle von Fehlidentifizierungen. Resultate der Tests, die mit Studenten durchgeführt wurden, neigen dazu Entscheidungsphasen als die anfälligsten für Stimuli aufzuzeigen, die Beobachtungseffekte anregen könnten. Für die halbstandardisierten Interviews beantworteten elf Forensiker Fragen über Themen wie zum Beispiel mögliche und vorhandene Fehlerquellen in ihrer Arbeit, Grenzen der forensischen Wissenschaften und Möglichkeiten und Mittel um Fehler zu verringern. Wie Training und Ausbildung die Qualität der forensischen Wissenschaften verbessern können ist zusammen mit möglichen Lösungen zur Fehlervermeidung im selben Bereich diskutiert worden. Wie lange Beweismitten aufbewahrt werden wurde auch festgehalten. Resultate neigen dazu, für die meisten Themen eine grosse Übereinstimmung zwischen den verschiedenen internationalen Teilnehmern zu zeigen. Ihre Meinungen über mögliche Erklärungen für das Auftreten solcher Probleme und des relativen Gewichts solcher Fehler in den drei Phasen Tatort, Labor und Rapportschreiben gehen jedoch mit den Meinungen, welche in der Literatur vertreten werden auseinander. Durch diese Forschungsarbeit war es folglich möglich, ein besseres Verständnis der Interaktion von forensischen Wissenschaften und Justizirrtümer zu erhalten, um somit praktische Empfehlungen vorzuschlagen, welche diese verringern. Resumen : Esta investigación ha analizado de manera empírica el rol de las ciencias forenses como fuente y como remedio de potenciales errores judiciales. La metodología empleada consistió en una revisión integral de la literatura, en una serie de experimentos sobre la influencia de los sesgos de observación en la individualización de huellas dactilares y en una serie de entrevistas semiestructuradas con jefes de laboratorios o unidades de ciencias forenses en Suiza y en el extranjero. En la revisión de la literatura, algunas de las áreas estudiadas fueron: la calidad del trabajo en ciencias forenses en general, la interacción compleja entre la ciencia y el derecho, así como otras fuentes de error no relacionadas directamente con la interacción entre derecho y ciencia. También se ha establecido una lista exhaustiva de las fuentes potenciales de error desde la llegada a la escena del crimen a la redacción del informe. En el marco de los tests empíricos, al analizar los sesgos de observación dedicamos especial interés al proceso de ACE-V (análisis, comparación, evaluación y verificación) para la individualización de huellas dactilares puesto que este reposa sobre la observación visual y ha originado varios casos recientes de identificaciones erróneas. Los resultados de las experimentaciones realizadas con estudiantes sugieren que las etapas en las que deben tornarse decisiones son las más vulnerables a lös factores que pueden generar sesgos de observación. En el contexto de las entrevistas semi-estructuradas, once científicos forenses de diversos países contestaron preguntas sobre varios temas, incluyendo las fuentes potenciales y existehtes de error en su trabajo, las limitaciones propias a las ciencias forenses, las posibilidades de reducir al mínimo los errores y las herramientas que podrían ser utilizadas para ello. Se han sugerido diversas soluciones para alcanzar este objetivo, incluyendo el entrenamiento y la educación para aumentar la calidad de las ciencias forenses. Además, se ha establecido el periodo de conservación de las muestras judiciales. Los resultados apuntan a un elevado grado de consenso entre los entrevistados en la mayoría de los temas. Sin embargo, sus opiniones sobre las posibles causas de estos errores y su importancia relativa en las tres etapas de la investigación -la escena del crimen, el laboratorio y la redacción de informe- discrepan con las que predominan ampliamente en la literatura actual. De este modo, esta investigación nos ha permitido obtener una mejor imagen de la interacción entre ciencias forenses y errores judiciales, y comenzar a formular una serie de recomendaciones prácticas para reducirlos al minimo.
Resumo:
RESUME Les améliorations méthodologiques des dernières décennies ont permis une meilleure compréhension de la motilité gastro-intestinale. Il manque toutefois une méthode qui permette de suivre la progression du chyme le long du tube gastro-intestinal. Pour permettre l'étude de la motilité de tout le tractus digestif humain, une nouvelle technique, peu invasive, a été élaborée au Département de Physiologie, en collaboration avec l'EPFL. Appelée "Magnet Tracking", la technique est basée sur la détection du champ magnétique généré par des matériaux ferromagnétiques avalés. A cet usage, une pilule magnétique, une matrice de capteurs et un logiciel ont été développés. L'objet de ce travail est de démontrer la faisabilité d'un examen de la motilité gastro-intestinale chez l'Homme par cette méthode. L'aimant est un cylindre (ø 6x7 mm, 0.2 cm3) protégé par une gaine de silicone. Le système de mesure est constitué d'une matrice de 4x4 capteurs et d'un ordinateur portable. Les capteurs fonctionnent sur l'effet Hall. Grâce à l'interface informatique, l'évolution de la position de l'aimant est suivie en temps réel à travers tout le tractus digestif. Sa position est exprimée en fonction du temps ou reproduite en 3-D sous forme d'une trajectoire. Différents programmes ont été crées pour analyser la dynamique des mouvements de l'aimant et caractériser la motilité digestive. Dix jeunes volontaires en bonne santé ont participé à l'étude. L'aimant a été avalé après une nuit de jeûne et son séjour intra digestif suivi pendant 2 jours consécutifs. Le temps moyen de mesure était de 34 heures. Chaque sujet a été examiné une fois sauf un qui a répété sept fois l'expérience. Les sujets restaient en décubitus dorsal, tranquilles et pouvaient interrompre la mesure s'ils le désiraient. Ils sont restés à jeûne le premier jour. L'évacuation de l'aimant a été contrôlée chez tous les sujets. Tous les sujets ont bien supporté l'examen. Le marqueur a pu être détecté de l'oesophage au rectum. La trajectoire ainsi constituée représente une conformation de l'anatomie digestive : une bonne superposition de celle-ci à l'anatomie est obtenue à partir des images de radiologie conventionnelle (CT-scan, lavement à la gastrografine). Les mouvements de l'aimant ont été caractérisés selon leur périodicité, leur amplitude ou leur vitesse pour chaque segment du tractus digestif. Ces informations physiologiques sont bien corrélées à celles obtenues par des méthodes établies d'étude de la motilité gastro-intestinale. Ce travail démontre la faisabilité d'un examen de la motilité gastro-intestinal chez l'Homme par la méthode de Magnet Tracking. La technique fournit les données anatomiques et permet d'analyser en temps réel la dynamique des mouvements du tube digestif. Cette méthode peu invasive ouvre d'intéressantes perspectives pour l'étude de motilité dans des conditions physiologiques et pathologiques. Des expériences visant à valider cette approche en tant que méthode clinique sont en voie de réalisation dans plusieurs centres en Suisse et à l'étranger. SUMMARY Methodological improvements realised over the last decades have permitted a better understanding of gastrointestinal motility. Nevertheless, a method allowing a continuous following of lumina' contents is still lacking. In order to study the human digestive tract motility, a new minimally invasive technique was developed at the Department of Physiology in collaboration with Swiss Federal Institute of Technology. The method is based on the detection of magnetic field generated by swallowed ferromagnetic materials. The aim of our work was to demonstrate the feasibility of this new approach to study the human gastrointestinal motility. The magnet used was a cylinder (ø6x7mm, 0.2 cm3) coated with silicon. The magnet tracking system consisted of a 4x4 matrix of sensors based on the Hall effect Signals from the sensors were digitised and sent to a laptop computer for processing and storage. Specific software was conceived to analyse in real time the progression of the magnet through the gastrointestinal tube. Ten young and healthy volunteers were enrolled in the study. After a fasting period of 12 hours, they swallowed the magnet. The pill was then tracked for two consecutive days for 34 hours on average. Each subject was studied once except one who was studied seven times. Every subject laid on his back for the entire experiment but could interrupt it at anytime. Evacuation of the magnet was controlled in all subjects. The examination was well tolerated. The pill could be followed from the esophagus to the rectum. The trajectory of the magnet represented a "mould" of the anatomy of the digestive tube: a good superimposition with radiological anatomy (gastrografin contrast and CT) was obtained. Movements of the magnet were characterized by periodicity, velocity, and amplitude of displacements for every segment of the digestive tract. The physiological information corresponded well to data from current methods of studying gastrointestinal motility. This work demonstrates the feasibility of the new approach in studies of human gastrointestinal motility. The technique allows to correlate in real time the dynamics of digestive movements with the anatomical data. This minimally invasive method is ready for studies of human gastrointestinal motility under physiological as well as pathological conditions. Studies aiming at validation of this new approach as a clinically relevant tool are being realised in several centres in Switzerland and abroad. Abstract: A new minimally invasive technique allowing for anatomical mapping and motility studies along the entire human digestive system is presented. The technique is based on continuous tracking of a small magnet progressing through the digestive tract. The coordinates of the magnet are calculated from signals recorded by 16 magnetic field sensors located over the abdomen. The magnet position, orientation and trajectory are displayed in real time. Ten young healthy volunteers were followed during 34 h. The technique was well tolerated and no complication was encountered, The information obtained was 3-D con-figuration of the digestive tract and dynamics of the magnet displacement (velocity, transit time, length estimation, rhythms). In the same individual, repea-ted examination gave very reproducible results. The anatomical and physiological information obtained corresponded well to data from current methods and imaging. This simple, minimally invasive technique permits examination of the entire digestive tract and is suitable for both research and clinical studies. In combination with other methods, it may represent a useful tool for studies of Cl motility with respect to normal and pathological conditions.
Resumo:
Understanding brain reserve in preclinical stages of neurodegenerative disorders allows determination of which brain regions contribute to normal functioning despite accelerated neuronal loss. Besides the recruitment of additional regions, a reorganisation and shift of relevance between normally engaged regions are a suggested key mechanism. Thus, network analysis methods seem critical for investigation of changes in directed causal interactions between such candidate brain regions. To identify core compensatory regions, fifteen preclinical patients carrying the genetic mutation leading to Huntington's disease and twelve controls underwent fMRI scanning. They accomplished an auditory paced finger sequence tapping task, which challenged cognitive as well as executive aspects of motor functioning by varying speed and complexity of movements. To investigate causal interactions among brain regions a single Dynamic Causal Model (DCM) was constructed and fitted to the data from each subject. The DCM parameters were analysed using statistical methods to assess group differences in connectivity, and the relationship between connectivity patterns and predicted years to clinical onset was assessed in gene carriers. In preclinical patients, we found indications for neural reserve mechanisms predominantly driven by bilateral dorsal premotor cortex, which increasingly activated superior parietal cortices the closer individuals were to estimated clinical onset. This compensatory mechanism was restricted to complex movements characterised by high cognitive demand. Additionally, we identified task-induced connectivity changes in both groups of subjects towards pre- and caudal supplementary motor areas, which were linked to either faster or more complex task conditions. Interestingly, coupling of dorsal premotor cortex and supplementary motor area was more negative in controls compared to gene mutation carriers. Furthermore, changes in the connectivity pattern of gene carriers allowed prediction of the years to estimated disease onset in individuals. Our study characterises the connectivity pattern of core cortical regions maintaining motor function in relation to varying task demand. We identified connections of bilateral dorsal premotor cortex as critical for compensation as well as task-dependent recruitment of pre- and caudal supplementary motor area. The latter finding nicely mirrors a previously published general linear model-based analysis of the same data. Such knowledge about disease specific inter-regional effective connectivity may help identify foci for interventions based on transcranial magnetic stimulation designed to stimulate functioning and also to predict their impact on other regions in motor-associated networks.
Resumo:
Object The purpose of this study was to investigate whether diffusion tensor imaging (DTI) of the corticospinal tract (CST) is a reliable surrogate for intraoperative macrostimulation through the deep brain stimulation (DBS) leads. The authors hypothesized that the distance on MRI from the DBS lead to the CST as determined by DTI would correlate with intraoperative motor thresholds from macrostimulations through the same DBS lead. Methods The authors retrospectively reviewed pre- and postoperative MRI studies and intraoperative macrostimulation recordings in 17 patients with Parkinson disease (PD) treated by DBS stimulation. Preoperative DTI tractography of the CST was coregistered with postoperative MRI studies showing the position of the DBS leads. The shortest distance and the angle from each contact of each DBS lead to the CST was automatically calculated using software-based analysis. The distance measurements calculated for each contact were evaluated with respect to the intraoperative voltage thresholds that elicited a motor response at each contact. Results There was a nonsignificant trend for voltage thresholds to increase when the distances between the DBS leads and the CST increased. There was a significant correlation between the angle and the voltage, but the correlation was weak (coefficient of correlation [R] = 0.36). Conclusions Caution needs to be exercised when using DTI tractography information to guide DBS lead placement in patients with PD. Further studies are needed to compare DTI tractography measurements with other approaches such as microelectrode recordings and conventional intraoperative MRI-guided placement of DBS leads.
Resumo:
BACKGROUND: Various centralised mammography screening programmes have shown to reduce breast cancer mortality at reasonable costs. However, mammography screening is not necessarily cost-effective in every situation. Opportunistic screening, the predominant screening modality in several European countries, may under certain circumstances be a cost-effective alternative. In this study, we compared the cost-effectiveness of both screening modalities in Switzerland. METHODS: Using micro-simulation modelling, we predicted the effects and costs of biennial mammography screening for 50-69 years old women between 1999 and 2020, in the Swiss female population aged 30-70 in 1999. A sensitivity analysis on the test sensitivity of opportunistic screening was performed. RESULTS: Organised mammography screening with an 80% participation rate yielded a breast cancer mortality reduction of 13%. Twenty years after the start of screening, the predicted annual breast cancer mortality was 25% lower than in a situation without screening. The 3% discounted cost-effectiveness ratio of organised mammography screening was euro11,512 per life year gained. Opportunistic screening with a similar participation rate was comparably effective, but at twice the costs: euro22,671-24,707 per life year gained. This was mainly related to the high costs of opportunistic mammography and frequent use of imaging diagnostics in combination with an opportunistic mammogram. CONCLUSION: Although data on the performance of opportunistic screening are limited, both opportunistic and organised mammography screening seem effective in reducing breast cancer mortality in Switzerland. However, for opportunistic screening to become equally cost-effective as organised screening, costs and use of additional diagnostics should be reduced.
Resumo:
We performed association studies with 5,151 SNPs that were judged as likely candidate genetic variations conferring susceptibility to anorexia nervosa (AN) based on location under reported linkage peaks, previous results in the literature (182 candidate genes), brain expression, biological plausibility, and estrogen responsivity. We employed a case-control design that tested each SNP individually as well as haplotypes derived from these SNPs in 1,085 case individuals with AN diagnoses and 677 control individuals. We also performed separate association analyses using three increasingly restrictive case definitions for AN: all individuals with any subtype of AN (All AN: n = 1,085); individuals with AN with no binge eating behavior (AN with No Binge Eating: n = 687); and individuals with the restricting subtype of AN (Restricting AN: n = 421). After accounting for multiple comparisons, there were no statistically significant associations for any individual SNP or haplotype block with any definition of illness. These results underscore the importance of large samples to yield appropriate power to detect genotypic differences in individuals with AN and also motivate complementary approaches involving Genome-Wide Association (GWA) studies, Copy Number Variation (CNV) analyses, sequencing-based rare variant discovery assays, and pathway-based analysis in order to make up for deficiencies in traditional candidate gene approaches to AN.
Resumo:
Decision to revascularize a patient with stable coronary artery disease should be based on the detection of myocardial ischemia. If this decision can be straightforward with significant stenosis or in non-significant stenosis, the decision with intermediate stenosis is far more difficult and require invasive measures of functional impact of coronary stenosis on maximal blood (flow fractional flow reserve=FFR). A recent computer based method has been developed and is able to measure FFR with data acquired during a standard coronary CT-scan (FFRcT). Two recent clinical studies (DeFACTO and DISCOVER-FLOW) show that diagnostic performance of FFRcT was associated with improved diagnostic accuracy versus standard coronary CT-scan for the detection of myocardial ischemia although FFRcT need further development.
Resumo:
Optimal behavior relies on flexible adaptation to environmental requirements, notably based on the detection of errors. The impact of error detection on subsequent behavior typically manifests as a slowing down of RTs following errors. Precisely how errors impact the processing of subsequent stimuli and in turn shape behavior remains unresolved. To address these questions, we used an auditory spatial go/no-go task where continual feedback informed participants of whether they were too slow. We contrasted auditory-evoked potentials to left-lateralized go and right no-go stimuli as a function of performance on the preceding go stimuli, generating a 2 × 2 design with "preceding performance" (fast hit [FH], slow hit [SH]) and stimulus type (go, no-go) as within-subject factors. SH trials yielded SH trials on the following trials more often than did FHs, supporting our assumption that SHs engaged effects similar to errors. Electrophysiologically, auditory-evoked potentials modulated topographically as a function of preceding performance 80-110 msec poststimulus onset and then as a function of stimulus type at 110-140 msec, indicative of changes in the underlying brain networks. Source estimations revealed a stronger activity of prefrontal regions to stimuli after successful than error trials, followed by a stronger response of parietal areas to the no-go than go stimuli. We interpret these results in terms of a shift from a fast automatic to a slow controlled form of inhibitory control induced by the detection of errors, manifesting during low-level integration of task-relevant features of subsequent stimuli, which in turn influences response speed.
Resumo:
Achieving a high degree of dependability in complex macro-systems is challenging. Because of the large number of components and numerous independent teams involved, an overview of the global system performance is usually lacking to support both design and operation adequately. A functional failure mode, effects and criticality analysis (FMECA) approach is proposed to address the dependability optimisation of large and complex systems. The basic inductive model FMECA has been enriched to include considerations such as operational procedures, alarm systems. environmental and human factors, as well as operation in degraded mode. Its implementation on a commercial software tool allows an active linking between the functional layers of the system and facilitates data processing and retrieval, which enables to contribute actively to the system optimisation. The proposed methodology has been applied to optimise dependability in a railway signalling system. Signalling systems are typical example of large complex systems made of multiple hierarchical layers. The proposed approach appears appropriate to assess the global risk- and availability-level of the system as well as to identify its vulnerabilities. This enriched-FMECA approach enables to overcome some of the limitations and pitfalls previously reported with classical FMECA approaches.
Resumo:
The objective of this study was to investigate whether it is possible to pool together diffusion spectrum imaging data from four different scanners, located at three different sites. Two of the scanners had identical configuration whereas two did not. To measure the variability, we extracted three scalar maps (ADC, FA and GFA) from the DSI and utilized a region and a tract-based analysis. Additionally, a phantom study was performed to rule out some potential factors arising from the scanner performance in case some systematic bias occurred in the subject study. This work was split into three experiments: intra-scanner reproducibility, reproducibility with twin-scanner settings and reproducibility with other configurations. Overall for the intra-scanner and twin-scanner experiments, the region-based analysis coefficient of variation (CV) was in a range of 1%-4.2% and below 3% for almost every bundle for the tract-based analysis. The uncinate fasciculus showed the worst reproducibility, especially for FA and GFA values (CV 3.7-6%). For the GFA and FA maps, an ICC value of 0.7 and above is observed in almost all the regions/tracts. Looking at the last experiment, it was found that there is a very high similarity of the outcomes from the two scanners with identical setting. However, this was not the case for the two other imagers. Given the fact that the overall variation in our study is low for the imagers with identical settings, our findings support the feasibility of cross-site pooling of DSI data from identical scanners.
Resumo:
The prognosis of superficial bladder cancer in terms of recurrence and disease progression is related to bladder tumor multiplicity and the presence of concomitant "plane" tumors such as high-grade dysplasia and carcinoma in situ. This study in 33 patients aimed to demonstrate the role of fluorescence cystoscopy in transurethral resection of superficial bladder cancer. The method is based on the detection of protoporphyrin-IX-induced fluorescence in urothelial cancer cells by topical administration of 5-aminolevulinic acid. The sensitivity and the specificity of this procedure on apparently normal mucosa in superficial bladder cancer are estimated to be 82.9% and 81.3%, respectively. Thus, fluorescence cytoscopy is a simple and reliable method for mapping the bladder mucosa, especially in the case of multifocal bladder disease, and it facilitates the screening of occult dysplasia.
Resumo:
HIV-1 diagnosis is usually based on the detection of specific antibodies, appearing in a time-determined pattern following the infection. We describe a prolonged HIV-1 seroconversion in an elite controller (defined as having HIV-1 RNA persistently <50copies/ml while untreated). HIV-1 diagnosis was delayed and complicated by this atypical evolution.