257 resultados para Drug-monitoring systems
Resumo:
A liquid chromatography method coupled to mass spectrometry was developed for the quantification of bupropion, its metabolite hydroxy-bupropion, moclobemide, reboxetine and trazodone in human plasma. The validation of the analytical procedure was assessed according to Société Française des Sciences et Techniques Pharmaceutiques and the latest Food and Drug Administration guidelines. The sample preparation was performed with 0.5mL of plasma extracted on a cation-exchange solid phase 96-well plate. The separation was achieved in 14min on a C18 XBridge column (2.1mm×100mm, 3.5μm) using a 50mM ammonium acetate pH 9/acetonitrile mobile phase in gradient mode. The compounds of interest were analysed in the single ion monitoring mode on a single quadrupole mass spectrometer working in positive electrospray ionisation mode. Two ions were selected per molecule to increase the number of identification points and to avoid as much as possible any false positives. Since selectivity is always a critical point for routine therapeutic drug monitoring, more than sixty common comedications for the psychiatric population were tested. For each analyte, the analytical procedure was validated to cover the common range of concentrations measured in plasma samples: 1-400ng/mL for reboxetine and bupropion, 2-2000ng/mL for hydroxy-bupropion, moclobemide, and trazodone. For all investigated compounds, reliable performance in terms of accuracy, precision, trueness, recovery, selectivity and stability was obtained. One year after its implementation in a routine process, this method demonstrated a high robustness with accurate values over the wide concentration range commonly observed among a psychiatric population.
Resumo:
A selective and sensitive method was developed for the simultaneous quantification of seven typical antipsychotic drugs (cis-chlorprothixene, flupentixol, haloperidol, levomepromazine, pipamperone, promazine and zuclopenthixol) in human plasma. Ultra-high performance liquid chromatography (UHPLC) was used for complete separation of the compounds in less than 4.5min on an Acquity UPLC BEH C18 column (2.1mm×50mm; 1.7μm), with a gradient elution of ammonium formate buffer pH 4.0 and acetonitrile at a flow rate of 400μl/min. Detection was performed on a tandem quadrupole mass spectrometer (MS/MS) equipped with an electrospray ionization interface. A simple protein precipitation procedure with acetonitrile was used for sample preparation. Thanks to the use of stable isotope-labeled internal standards for all analytes, internal standard-normalized matrix effects were in the range of 92-108%. The method was fully validated to cover large concentration ranges of 0.2-90ng/ml for haloperidol, 0.5-90ng/ml for flupentixol, 1-450ng/ml for levomepromazine, promazine and zuclopenthixol and 2-900ng/ml for cis-chlorprothixene and pipamperone. Trueness (89.1-114.8%), repeatability (1.8-9.9%), intermediate precision (1.9-16.3%) and accuracy profiles (<30%) were in accordance with the latest international recommendations. The method was successfully used in our laboratory for routine quantification of more than 500 patient plasma samples for therapeutic drug monitoring. To the best of our knowledge, this is the first UHPLC-MS/MS method for the quantification of the studied drugs with a sample preparation based on protein precipitation.
Resumo:
Introduction: As imatinib pharmacokinetics are highly variable, plasma levels differ largely between patients under the same dosage. Retrospective studies in chronic myeloid leukemia (CML) patients showed significant correlations between low levels and suboptimal response, as well as between high levels and poor tolerability. Monitoring of trough plasma levels, targeting 1000 μg/L and above, is thus increasingly advised. Our study was launched to assess prospectively the clinical usefulness of systematic imatinib TDM in CML patients. This preliminary analysis addresses the appropriateness of the dosage adjustment approach applied in this study, which targets the recommended trough level and allows an interval of 4-24 h after last drug intake for blood sampling. Methods: Blood samples from the first 15 patients undergoing 1st TDM were obtained 1.5-25 h after last dose. Imatinib plasma levels were measured by LC-MS/MS and the concentrations were extrapolated to trough based on a Bayesian approach using a population pharmacokinetic model. Trough levels were predicted to differ significantly from the target in 12 patients (10 <750 μg/L; 2 >1500 μg/L along with poor tolerance) and individual dose adjustments were proposed. 8 patients underwent a 2nd TDM cycle. Trough levels of 1st and 2nd TDM were compared, the sample drawn 1.5 h after last dose (during distribution phase) was excluded from the analysis. Results: Individual dose adjustments were applied in 6 patients. Observed concentrations extrapolated to trough ranged from 360 to 1832 μg/L (median 725; mean 810, CV 52%) on 1st TDM and from 720 to 1187 μg/L (median 950; mean 940, CV 18%) on 2nd TDM cycle. Conclusions: These preliminary results suggest that TDM of imatinib using a Bayesian interpretation is able to target the recommended trough level of 1000 μg/L and to reduce the considerable differences in trough level exposure between patients (with CV decreasing from 52% to 18%). While this may simplify blood collection in daily practice, as samples do not have to be drawn exactly at trough, the largest possible interval to last drug intake yet remains preferable to avoid sampling during distribution phase leading to biased extrapolation. This encourages the evaluation of the clinical benefit of a routine TDM intervention in CML patients, which the randomized Swiss I-COME trial aims to.
Resumo:
New directly acting antivirals (DAAs) that inhibit hepatitis C virus (HCV) replication are increasingly used for the treatment of chronic hepatitis C. A marked pharmacokinetic variability and a high potential for drug-drug interactions between DAAs and numerous drug classes have been identified. In addition, ribavirin (RBV), commonly associated with hemolytic anemia, often requires dose adjustment, advocating for therapeutic drug monitoring (TDM) in patients under combined antiviral therapy. However, an assay for the simultaneous analysis of RBV and DAAs constitutes an analytical challenge because of the large differences in polarity among these drugs, ranging from hydrophilic (RBV) to highly lipophilic (telaprevir [TVR]). Moreover, TVR is characterized by erratic behavior on standard octadecyl-based reversed-phase column chromatography and must be separated from VRT-127394, its inactive C-21 epimer metabolite. We have developed a convenient assay employing simple plasma protein precipitation, followed by high-performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) for the simultaneous determination of levels of RBV, boceprevir, and TVR, as well as its metabolite VRT-127394, in plasma. This new, simple, rapid, and robust HPLC-MS/MS assay offers an efficient method of real-time TDM aimed at maximizing efficacy while minimizing the toxicity of antiviral therapy.
Resumo:
From data collected during routine TDM, plasma concentrations of citalopram (CIT) and its metabolites demethylcitalopram (DCIT) and didemethylcitalopram (DDCIT) were measured in 345 plasma samples collected in steady-state conditions. They were from 258 patients treated with usual doses (20-60 mg/d) and from patients medicated with 80-360 mg/d CIT. Most patients had one or several comedications, including other antidepressants, antipsychotics, lithium, anticonvulsants, psychostimulants and somatic medications. Dose-corrected CIT plasma concentrations (C/D ratio) were 2.51 +/- 2.25 ng mL-1 mg-1 (n = 258; mean +/- SD). Patients >65 years had significantly higher dose-corrected CIT plasma concentrations (n = 56; 3.08 +/- 1.35 ng mL-1 mg-1) than younger patients (n = 195; 2.35 +/- 2.46 ng mL-1 mg-1) (P = 0.03). CIT plasma concentrations in the generally recommended dose range were [mean +/- SD, (median)]: 57 +/- 64 (45) ng/mL (10-20 mg/d; n = 64), 117 +/- 95 (91) ng/mL (21-60 mg/d; n = 96). At higher than usual doses, the following concentrations of CIT were measured: 61-120 mg/d CIT, 211 +/- 103 (190) ng/mL (n = 93); 121-200 mg/d: 339 +/- 143 (322) ng/mL (n = 70); 201-280 mg/d: 700 +/- 408 (565) ng/mL (n = 18); 281-360 mg/d: 888 +/- 620 (616) ng/mL (n = 4). When only one sample per patient (at the highest daily dose if repeated dosages) is considered, there is a linear and significant correlation (n = 48, r = 0.730; P < 0.001) between daily dose (10-200 mg/d) and CIT plasma concentrations. In experiments with dogs, DDCIT was reported to affect the QT interval when present at concentrations >300 ng/mL. In this study, DDCIT concentration reached 100 ng/mL in a patient treated with 280 mg/d CIT. Twelve other patients treated with 140-320 mg/d CIT had plasma concentrations of DDCIT within the range 52-73 ng/mL. In a subgroup comprised of patients treated with > or =160 mg/d CIT and with CIT plasma concentrations < or =300 ng/mL, and patients treated with < or =200 mg/d CIT and CIT plasma concentrations > or = 600 ng/mL, the enantiomers of CIT and DCIT were also analyzed. The highest S-CIT concentration measured in this subgroup was 327 ng/mL in a patient treated with 140 mg/d CIT, but the highest S-CIT concentration (632 ng/mL) was measured in patient treated with 360 mg/d CIT. In conclusion, there is a highly linear correlation between CIT plasma concentrations and CIT doses, well above the usual dose range.
Resumo:
A simple and sensitive liquid chromatography-electrospray ionization mass spectrometry method was developed for the simultaneous quantification in human plasma of all selective serotonin reuptake inhibitors (citalopram, fluoxetine, fluvoxamine, paroxetine and sertraline) and their main active metabolites (desmethyl-citalopram and norfluoxetine). A stable isotope-labeled internal standard was used for each analyte to compensate for the global method variability, including extraction and ionization variations. After sample (250μl) pre-treatment with acetonitrile (500μl) to precipitate proteins, a fast solid-phase extraction procedure was performed using mixed mode Oasis MCX 96-well plate. Chromatographic separation was achieved in less than 9.0min on a XBridge C18 column (2.1×100mm; 3.5μm) using a gradient of ammonium acetate (pH 8.1; 50mM) and acetonitrile as mobile phase at a flow rate of 0.3ml/min. The method was fully validated according to Société Française des Sciences et Techniques Pharmaceutiques protocols and the latest Food and Drug Administration guidelines. Six point calibration curves were used to cover a large concentration range of 1-500ng/ml for citalopram, desmethyl-citalopram, paroxetine and sertraline, 1-1000ng/ml for fluoxetine and fluvoxamine, and 2-1000ng/ml for norfluoxetine. Good quantitative performances were achieved in terms of trueness (84.2-109.6%), repeatability (0.9-14.6%) and intermediate precision (1.8-18.0%) in the entire assay range including the lower limit of quantification. Internal standard-normalized matrix effects were lower than 13%. The accuracy profiles (total error) were mainly included in the acceptance limits of ±30% for biological samples. The method was successfully applied for routine therapeutic drug monitoring of more than 1600 patient plasma samples over 9 months. The β-expectation tolerance intervals determined during the validation phase were coherent with the results of quality control samples analyzed during routine use. This method is therefore precise and suitable both for therapeutic drug monitoring and pharmacokinetic studies in most clinical laboratories.