204 resultados para Digestive System Surgical Procedures
Partial cricotracheal resection for pediatric subglottic stenosis: long-term outcome in 57 patients.
Resumo:
OBJECTIVE: We sought to assess the long-term outcome of 57 pediatric patients who underwent partial cricotracheal resection for subglottic stenosis. METHODS: Eighty-one pediatric partial cricotracheal resections were performed in our tertiary care institution between 1978 and 2004. Fifty-seven patients had a minimal follow-up time of 1 year and were included in this study. Evaluation was based on the last laryngotracheal endoscopy, the responses to a questionnaire, and a retrospective review of the patient's data. The following parameters were analyzed: decannulation rates, breathing, voice quality, and deglutition. RESULTS: A single-stage partial cricotracheal resection was performed in 38 patients, and a double-stage procedure was performed in 19 patients. Sixteen patients underwent an extended partial cricotracheal resection (ie, partial cricotracheal resection combined with another open procedure). At a median follow-up time of 5.1 years, the decannulation rates after a single- or double-stage procedure were 97.4% and 95%, respectively. Two patients remained tracheotomy dependent. One patient had moderate exertional dyspnea, and all other patients had no exertional dyspnea. Voice quality was found to improve after surgical intervention for 1 +/- 1.34 grade dysphonia (P < .0001) according to the adapted GRBAS grading system (Grade, Roughness, Breathiness, Asthenia, and Strain). CONCLUSIONS: Partial cricotracheal resection provides good results for grades III and IV subglottic stenosis as primary or salvage operations. The procedure has no deleterious effects on laryngeal growth and function. The quality of voice significantly improves after surgical intervention but largely depends on the preoperative condition.
Resumo:
The relationship between coffee drinking and the risk of digestive tract neoplasms was analyzed in a case-control study of 50 cases of cancer of the mouth or pharynx, 209 of the esophagus, 397 of the stomach, 455 of the colon, 295 of the rectum, 151 of the liver, 214 of the pancreas, and 1944 control subjects admitted for acute, non-digestive tract disorders. There was no significant or consistent association between coffee and cancers of the mouth or pharynx, esophagus, stomach, liver, or pancreas. In particular, for pancreatic cancer, the multivariate relative risks for the intermediate and upper tertiles were 1.05 and 1.01, respectively. There were significant inverse trends in risk with measures of coffee consumption for colon and rectal cancers, the multivariate relative risks according to tertiles of coffee consumption being 0.86 and 0.64 for colon and 0.97 and 0.66 for rectum. This apparent protection is in agreement with some (but not all) previous epidemiological evidence and finds a possible biological interpretation in terms of interference on bile secretion, causing reduced bile acid and neutral sterol concentrations in the bowel. In conclusion, the results of this study, the major interest of which lies in the opportunity of drawing up an overall pattern of risk for various digestive neoplasms, offer further reassurance as regards the effects of coffee on digestive tract carcinogenesis.
Resumo:
BACKGROUND: Use of cardiopulmonary bypass for emergency resuscitation is not new. In fact, John Gibbon proposed this concept for the treatment of severe pulmonary embolism in 1937. Significant progress has been made since, and two main concepts for cardiac assist based on cardiopulmonary bypass have emerged: cardiopulmonary support (CPS) and extracorporeal membrane oxygenation (ECMO). The objective of this review is to summarize the state of the art in these two technologies. METHODS: Configuration of CPS is now fairly standard. A mobile cart with relatively large wheels allowing for easy transportation carries a centrifugal pump, a back-up battery with a charger, an oxygen cylinder, and a small heating system. Percutaneous cannulation, pump-driven venous return, rapid availability, and transportability are the main characteristics of a CPS system. Cardiocirculatory arrest is a major predictor of mortality despite the use of CPS. In contrast, CPS appears to be a powerful tool for patients in cardiogenic shock before cardiocirculatory arrest, requiring some type of therapeutic procedures, especially repair of anatomically correctable problems or bridging to other mechanical circulatory support systems such as ventricular assist devices. CPS is in general not suitable for long-term applications because of the small-bore cannulas, resulting in significant pressure gradients and eventually hemolysis. RESULTS: In contrast, ECMO can be designed for longer-term circulatory support. This requires large-bore cannulas and specifically designed oxygenators. The latter are either plasma leakage resistent (true membranes) or relatively thrombo-resistant (heparin coated). Both technologies require oxygenator changeovers although the main reason for this is different (clotting for the former, plasma leakage for the latter). Likewise, the tubing within a roller pump has to be displaced and centrifugal pump heads have to be replaced over time. ECMO is certainly the first choice for a circulatory support system in the neonatal and pediatric age groups, where the other assist systems are too bulky. ECMO is also indicated for patients improving on CPS. Septic conditions are, in general, considered as contraindications for ECMO. CONCLUSIONS: Ease of availability and moderate cost of cardiopulmonary bypass-based cardiac support technologies have to be balanced against the significant immobilization of human resources, which is required to make them successful.
Resumo:
BACKGROUND: Partial excision of the nail matrix (matricectomy) is generally considered necessary in the surgical treatment of ingrown toenail. Recurrences may occur, however, and poor cosmetic results are frequently observed. OBJECTIVE: The objective is to present a new surgical procedure for ingrown toenail with complete preservation of the nail matrix. METHODS: Twenty-three patients with ingrown toenail were included in this study. The surgical excision was performed 1 week after the completion of treatment of the initial infection. A large volume of soft tissue surrounding the nail plate was removed under local anesthesia. No matrix excision was performed. RESULTS: Short-term results were excellent. No recurrences or severe complications were observed during the minimum 12-months follow-up period. Cosmetic results were remarkable. CONCLUSIONS: Ingrown toenail results from the compression of the lateral nail folds on the nail plate. This study shows that ingrown toenail can be surgically treated without matricectomy. A large volume of soft tissue surrounding the nail plate should be removed to decompress the nail and reduce inflammation. Cosmetic results are excellent and superior to the classical Emmert plasty. Postoperative nail dystrophies and spicule formation are not observed. The main advantage of this surgical approach is the complete preservation of the anatomy and function of the nail to improve both therapeutic and cosmetic results.
Resumo:
RESUME Les améliorations méthodologiques des dernières décennies ont permis une meilleure compréhension de la motilité gastro-intestinale. Il manque toutefois une méthode qui permette de suivre la progression du chyme le long du tube gastro-intestinal. Pour permettre l'étude de la motilité de tout le tractus digestif humain, une nouvelle technique, peu invasive, a été élaborée au Département de Physiologie, en collaboration avec l'EPFL. Appelée "Magnet Tracking", la technique est basée sur la détection du champ magnétique généré par des matériaux ferromagnétiques avalés. A cet usage, une pilule magnétique, une matrice de capteurs et un logiciel ont été développés. L'objet de ce travail est de démontrer la faisabilité d'un examen de la motilité gastro-intestinale chez l'Homme par cette méthode. L'aimant est un cylindre (ø 6x7 mm, 0.2 cm3) protégé par une gaine de silicone. Le système de mesure est constitué d'une matrice de 4x4 capteurs et d'un ordinateur portable. Les capteurs fonctionnent sur l'effet Hall. Grâce à l'interface informatique, l'évolution de la position de l'aimant est suivie en temps réel à travers tout le tractus digestif. Sa position est exprimée en fonction du temps ou reproduite en 3-D sous forme d'une trajectoire. Différents programmes ont été crées pour analyser la dynamique des mouvements de l'aimant et caractériser la motilité digestive. Dix jeunes volontaires en bonne santé ont participé à l'étude. L'aimant a été avalé après une nuit de jeûne et son séjour intra digestif suivi pendant 2 jours consécutifs. Le temps moyen de mesure était de 34 heures. Chaque sujet a été examiné une fois sauf un qui a répété sept fois l'expérience. Les sujets restaient en décubitus dorsal, tranquilles et pouvaient interrompre la mesure s'ils le désiraient. Ils sont restés à jeûne le premier jour. L'évacuation de l'aimant a été contrôlée chez tous les sujets. Tous les sujets ont bien supporté l'examen. Le marqueur a pu être détecté de l'oesophage au rectum. La trajectoire ainsi constituée représente une conformation de l'anatomie digestive : une bonne superposition de celle-ci à l'anatomie est obtenue à partir des images de radiologie conventionnelle (CT-scan, lavement à la gastrografine). Les mouvements de l'aimant ont été caractérisés selon leur périodicité, leur amplitude ou leur vitesse pour chaque segment du tractus digestif. Ces informations physiologiques sont bien corrélées à celles obtenues par des méthodes établies d'étude de la motilité gastro-intestinale. Ce travail démontre la faisabilité d'un examen de la motilité gastro-intestinal chez l'Homme par la méthode de Magnet Tracking. La technique fournit les données anatomiques et permet d'analyser en temps réel la dynamique des mouvements du tube digestif. Cette méthode peu invasive ouvre d'intéressantes perspectives pour l'étude de motilité dans des conditions physiologiques et pathologiques. Des expériences visant à valider cette approche en tant que méthode clinique sont en voie de réalisation dans plusieurs centres en Suisse et à l'étranger. SUMMARY Methodological improvements realised over the last decades have permitted a better understanding of gastrointestinal motility. Nevertheless, a method allowing a continuous following of lumina' contents is still lacking. In order to study the human digestive tract motility, a new minimally invasive technique was developed at the Department of Physiology in collaboration with Swiss Federal Institute of Technology. The method is based on the detection of magnetic field generated by swallowed ferromagnetic materials. The aim of our work was to demonstrate the feasibility of this new approach to study the human gastrointestinal motility. The magnet used was a cylinder (ø6x7mm, 0.2 cm3) coated with silicon. The magnet tracking system consisted of a 4x4 matrix of sensors based on the Hall effect Signals from the sensors were digitised and sent to a laptop computer for processing and storage. Specific software was conceived to analyse in real time the progression of the magnet through the gastrointestinal tube. Ten young and healthy volunteers were enrolled in the study. After a fasting period of 12 hours, they swallowed the magnet. The pill was then tracked for two consecutive days for 34 hours on average. Each subject was studied once except one who was studied seven times. Every subject laid on his back for the entire experiment but could interrupt it at anytime. Evacuation of the magnet was controlled in all subjects. The examination was well tolerated. The pill could be followed from the esophagus to the rectum. The trajectory of the magnet represented a "mould" of the anatomy of the digestive tube: a good superimposition with radiological anatomy (gastrografin contrast and CT) was obtained. Movements of the magnet were characterized by periodicity, velocity, and amplitude of displacements for every segment of the digestive tract. The physiological information corresponded well to data from current methods of studying gastrointestinal motility. This work demonstrates the feasibility of the new approach in studies of human gastrointestinal motility. The technique allows to correlate in real time the dynamics of digestive movements with the anatomical data. This minimally invasive method is ready for studies of human gastrointestinal motility under physiological as well as pathological conditions. Studies aiming at validation of this new approach as a clinically relevant tool are being realised in several centres in Switzerland and abroad. Abstract: A new minimally invasive technique allowing for anatomical mapping and motility studies along the entire human digestive system is presented. The technique is based on continuous tracking of a small magnet progressing through the digestive tract. The coordinates of the magnet are calculated from signals recorded by 16 magnetic field sensors located over the abdomen. The magnet position, orientation and trajectory are displayed in real time. Ten young healthy volunteers were followed during 34 h. The technique was well tolerated and no complication was encountered, The information obtained was 3-D con-figuration of the digestive tract and dynamics of the magnet displacement (velocity, transit time, length estimation, rhythms). In the same individual, repea-ted examination gave very reproducible results. The anatomical and physiological information obtained corresponded well to data from current methods and imaging. This simple, minimally invasive technique permits examination of the entire digestive tract and is suitable for both research and clinical studies. In combination with other methods, it may represent a useful tool for studies of Cl motility with respect to normal and pathological conditions.
Resumo:
BACKGROUND: The correction of oculomotor disorder in Grave's disease is applied on pathological extraocular muscles. Based on the global muscular restriction (bilateral forced duction test) and angular measurements, we have used a non-adjustable technique. PATIENTS AND METHODS: We performed a retrospective analysis of 21 patients (23 operations) with thyroid-associated orbitopathy operated for persisting diplopia. The angles of deviation in the 9 diagnostic directions of gaze and the field of binocular vision were measured with the Harm's tangent scale before and after surgery. Sixteen patients were operated only on vertical muscles. The mean follow-up was 45 months. RESULTS: 76 % of the patients (95 % confidence interval [CI], 58-94 %) obtained a large and centred field of binocular vision without prisms. 14 % (95 % CI, 0-29 %) had binocular vision with the use of prisms. Diplopia persisted in one patient despite 3 operations. Taking into consideration the interventions done before the patient was referred to us, the reintervention rate was 13 % (95 % CI, 0-28 %). CONCLUSIONS: A binocular field of vision can be successfully restored in the majority of patients with Graves' orbitopathy, using a non-adjustable surgical technique.
Resumo:
BACKGROUND: Multimodality treatment suites for patients with cerebral arteriovenous malformations (AVM) have recently become available. This study was designed to evaluate feasibility, safety and impact on treatment of a new intraoperative flat-panel (FP) based integrated surgical and imaging suite for combined endovascular and surgical treatment of cerebral AVM. METHODS: Twenty-five patients with AVMs to treat with combined endovascular and surgical interventions were prospectively enrolled in this consecutive case series. The hybrid suite allows combined endovascular and surgical approaches with intraoperative scanner-like imaging (XperCT®) and intraoperative 3D rotational angiography (3D-RA). The impact of intraoperative multimodal imaging on feasibility, workflow of combined interventions, surgery, and unexpected imaging findings were analyzed. RESULTS: Twenty-five patients (mean age 38 ± 18.6 year) with a median Spetzler-Martin grade 2 AVM (range 1-4) underwent combined endovascular and surgical procedures. Sixteen patients presented with a ruptured AVM and nine with an unruptured AVM. In 16 % (n = 4) of cases, intraoperative imaging visualized AVM remnants ≤3 mm and allowed for completion of the resections in the same sessions. Complete resection was confirmed in all n = 16 patients who had follow-up angiography one year after surgery so far. All diagnostic and therapeutical steps, including angiographic control, were performed without having to move the patients CONCLUSION: The hybrid neurointerventional suite was shown to be a safe and useful setup which allowed for unconstrained combined microsurgical and neuroradiological workflow. It reduces the need for extraoperative angiographic controls and subsequent potential surgical revisions a second time, as small AVM remnants can be detected with high security.
Resumo:
Adequate in-vitro training in valved stents deployment as well as testing of the latter devices requires compliant real-size models of the human aortic root. The casting methods utilized up to now are multi-step, time consuming and complicated. We pursued a goal of building a flexible 3D model in a single-step procedure. We created a precise 3D CAD model of a human aortic root using previously published anatomical and geometrical data and printed it using a novel rapid prototyping system developed by the Fab@Home project. As a material for 3D fabrication we used common house-hold silicone and afterwards dip-coated several models with dispersion silicone one or two times. To assess the production precision we compared the size of the final product with the CAD model. Compliance of the models was measured and compared with native porcine aortic root. Total fabrication time was 3 h and 20 min. Dip-coating one or two times with dispersion silicone if applied took one or two extra days, respectively. The error in dimensions of non-coated aortic root model compared to the CAD design was <3.0% along X, Y-axes and 4.1% along Z-axis. Compliance of a non-coated model as judged by the changes of radius values in the radial direction by 16.39% is significantly different (P<0.001) from native aortic tissue--23.54% at the pressure of 80-100 mmHg. Rapid prototyping of compliant, life-size anatomical models with the Fab@Home 3D printer is feasible--it is very quick compared to previous casting methods.
Resumo:
Contemporary thoracic and cardiovascular surgery uses extensive equipment and devices to enable its performance. As the specialties develop and new frontiers are crossed, the technology needs to advance in a parallel fashion. Strokes of genius or problem-solving brain-storming may generate great ideas, but the metamorphosis of an idea into a physical functioning tool requires a lot more than just a thinking process. A modern surgical device is the end-point of a sophisticated, complicated and potentially treacherous route, which incorporates new skills and knowledge acquisition. Processes including technology transfer, commercialisation, corporate and product development, intellectual property and regulatory routes all play pivotal roles in this voyage. Many good ideas may fall by the wayside for a multitude of reasons as they may not be marketable or may be badly marketed. In this article, we attempt to illuminate the components required in the process of surgical innovation, which we believe must remain in the remit of the modern-day thoracic and cardiovascular surgeon.
Resumo:
Facial reanimation following persistent facial paralysis can be managed with surgical procedures of varying complexity. The choice of the technique is mainly determined by the cause of facial paralysis, the age and desires of the patient. The techniques most commonly used are the nerve grafts (VII-VII, XII-VII, cross facial graft), dynamic muscle transfers (temporal myoplasty, free muscle transfert) and static suspensions. An intensive rehabilitation through specific exercises after all procedures is essential to archieve good results.
Resumo:
Paroxysmal nocturnal hemoglobinuria (PNH) is a rare, acquired stem cell disorder, with its primary clinical manifestations being hemolytic anemia, marrow failure and thrombophilia. Chronic hemolysis, failures of the fibrinolytic system, increased leukocyte-derived tissue factor levels in plasma, procoagulant microparticles generated through complement-mediated damage of platelets and venous endothelium are related to the acquired hypercoagulable state. Visceral thrombosis (including hepatic veins and mesenteric veins), cerebrovascular events and pulmonary embolism predict a poor outcome. Thrombosis is also associated with significant morbidity during pregnancy. Depending on the sites of thrombosis, a score-based probability to predict outcome can be assigned. Abdominal vein thromboses account for the majority of morbidity and mortality related to thrombosis, and time-dependent trends suggest that mortality rates tend to decline, with the advent of evolution of therapeutic and diagnostic strategies. In contrast, mortality rates from cerebrovascular events display no significant decline. Prompt diagnosis requires both clinical suspicion and sophisticated imaging techniques, along with multidisciplinary therapeutic intervention. In the eculizumab era, a significant reduction of thrombotic events was observed during therapy, and long-term follow up is needed to establish any benefit in rates and pattern of this complication. However, up to now, only bone marrow transplantation permanently abolishes the coagulation defect.
Resumo:
OBJECTIVES: To refine the classic definition of, and provide a working definition for, congenital high airway obstruction syndrome (CHAOS) and to discuss the various aspects of long-term airway reconstruction, including the range of laryngeal anomalies and the various techniques for reconstruction. DESIGN: Retrospective chart review. PATIENTS: Four children (age range, 2-8 years) with CHAOS who presented to a single tertiary care children's hospital for pediatric airway reconstruction between 1995 and 2000. CONCLUSIONS: To date, CHAOS remains poorly described in the otolaryngologic literature. We propose the following working definition for pediatric cases of CHAOS: any neonate who needs a surgical airway within 1 hour of birth owing to high upper airway (ie, glottic, subglottic, or upper tracheal) obstruction and who cannot be tracheally intubated other than through a persistent tracheoesophageal fistula. Therefore, CHAOS has 3 possible presentations: (1) complete laryngeal atresia without an esophageal fistula, (2) complete laryngeal atresia with a tracheoesophageal fistula, and (3) near-complete high upper airway obstruction. Management of the airway, particularly in regard to long-term reconstruction, in children with CHAOS is complex and challenging.
Resumo:
OBJECTIVE: To compare transanal endoscopic microsurgery (TEMS) with conventional transanal excision (TAE) in terms of the quality of resection, local recurrence, and survival rates in patients with stage I rectal cancer. BACKGROUND: Although TEMS is often considered a superior surgical technique to TAE, it is poorly suited for excising tumors in the lower third of the rectum. Such tumors may confer a worse prognosis. METHODS: We retrospectively reviewed information on all patients with stage pT1 and pT2 rectal adenocarcinoma who underwent local excision from 1997 through mid-2006. We excluded patients with node-positive, metastatic, recurrent, previously irradiated, or snare-excised tumors. RESULTS: Our study included 42 TEMS and 129 TAE patients. We found no significant differences in patient characteristics, adjuvant therapy, tumor stage, or adverse histopathologic features. In the TAE group, 52 (40%) of tumors were <5 cm from the anal verge (AV); in the TEMS group, only 1 (2%) (P = 0.0001). Surgical margins were less often positive in the TEMS group (2%) than in the TAE group (16%) (P = 0.017). For patients with tumors > or =5 cm from the AV, the estimated 5-year disease-free survival (DFS) rate was similar between the TEMS group (84.1%) and the TAE group (76.1%) (P = 0.651). But within the TAE group, the estimated 5-year DFS rate was better for patients with tumors > or =5 cm from the AV (76.1%) vs. <5 cm from the AV (60.5%) (P = 0.029). In our multivariate analysis, the tumor distance from the anal verge, the resection margin status, the T stage, and the use of adjuvant therapy--but not the surgical technique (i.e., TEMS or TAE) itself--were independent predictors of local recurrence and DFS. CONCLUSIONS: The quality of resection is better with TEMS than with TAE. However, the apparently better oncologic outcomes with TEMS can be partly explained by case selection of lower-risk tumors of the upper rectum.
Resumo:
Since 2000 and the commercialisation of the Da Vinci robotic system, indications for robotic surgery are rapidly increasing. Recent publications proved superior functional outcomes with equal oncologic safety in comparison to conventional open surgery. Its field of application may extend to the nasopharynx and skull base surgery. The preliminary results are encouraging. This article reviews the current literature on the role of transoral robotic surgery in head and neck cancer.