89 resultados para Commercial live vaccines
Resumo:
Pneumocystis jirovecii pneumonia (PCP) is a common opportunistic infection. Microscopic diagnosis, including diagnosis using the Merifluor-Pneumocystis direct fluorescent antigen (MP-DFA) test, has limitations. Real-time PCR may assist in diagnosis, but no commercially validated real-time PCR assay has been available to date. MycAssay Pneumocystis is a commercial assay that targets the P. jirovecii mitochondrial large subunit (analytical detection limit, ≤3.5 copies/μl of sample). A multicenter trial recruited 110 subjects: 54 with transplants (40 with lung transplants), 32 with nonmalignant conditions, 13 with leukemia, and 11 with solid tumors; 9 were HIV positive. A total of 110 respiratory samples (92% of which were bronchoalveolar lavage [BAL] specimens) were analyzed by PCR. Performance was characterized relative to investigator-determined clinical diagnosis of PCP (including local diagnostic tests), and PCR results were compared with MP-DFA test results for 83 subjects. Thirteen of 14 subjects with PCP and 9/96 without PCP (including 5 undergoing BAL surveillance after lung transplantation) had positive PCR results; sensitivity, specificity, and positive and negative predictive values (PPV and NPV, respectively) were 93%, 91%, 59%, and 99%, respectively. Fourteen of 83 subjects for whom PCR and MP-DFA test results were available had PCP; PCR sensitivity, specificity, PPV, and NPV were 93%, 90%, 65%, and 98%, respectively, and MP-DFA test sensitivity, specificity, PPV, and NPV were 93%, 100%, 100%, and 98%. Of the 9 PCR-positive subjects without PCP, 1 later developed PCP. The PCR diagnostic assay compares well with clinical diagnosis using nonmolecular methods. Additional positive results compared with the MP-DFA test may reflect low-level infection or colonization.
Resumo:
Combined positron emission tomography and computed tomography (PET/CT) scanners play a major role in medicine for in vivo imaging in an increasing number of diseases in oncology, cardiology, neurology, and psychiatry. With the advent of short-lived radioisotopes other than 18F and newer scanners, there is a need to optimize radioisotope activity and acquisition protocols, as well as to compare scanner performances on an objective basis. The Discovery-LS (D-LS) was among the first clinical PET/CT scanners to be developed and has been extensively characterized with older National Electrical Manufacturer Association (NEMA) NU 2-1994 standards. At the time of publication of the latest version of the standards (NU 2-2001) that have been adapted for whole-body imaging under clinical conditions, more recent models from the same manufacturer, i.e., Discovery-ST (D-ST) and Discovery-STE (D-STE), were commercially available. We report on the full characterization both in the two- and three-dimensional acquisition mode of the D-LS according to latest NEMA NU 2-2001 standards (spatial resolution, sensitivity, count rate performance, accuracy of count losses, and random coincidence correction and image quality), as well as a detailed comparison with the newer D-ST widely used and whose characteristics are already published.
Resumo:
Chronique de jurisprudence et de législation pour l'année 2008
Resumo:
Des équipes mobiles de psychiatrie ont été développées dans les trois âges pour répondre aux besoins de personnes qui devraient bénéficier d'une évaluation ou de soins spécialisés, lorsque ceux-ci doivent avoir lieu à domicile. Pour arriver à ce but, les équipes tissent de forts liens de partenariat dans le réseau, que ce soit avec les proches ou avec les professionnels impliqués. Les principes généraux d'intervention sont semblables entre les âges : une population cible définie, une intervention à domicile au bénéfice également des proches et des soins de proximité, des équipes pluridisciplinaires avec une charge de cas limitée pour garantir leur disponibilité. Les spécificités de chaque âge seront analysées. Mobile teams have been developed for the three ages to meet the needs of people who should receive--but do not access to--a psychiatric assessment or to specialized care. To achieve this goal, the teams built a strong partnership within the social network, both with relatives and professionals involved. The general principles of intervention are similar between the ages: a focused target population, assertive outreach which benefits also relatives and carers, multidisciplinary teams with a limited caseload to ensure availability. The specificities of each age will be analyzed
Saponins from the Spanish saffron Crocus sativus are efficient adjuvants for protein-based vaccines.
Resumo:
Protein and peptide-based vaccines provide rigorously formulated antigens. However, these purified products are only weakly immunogenic by themselves and therefore require the addition of immunostimulatory components or adjuvants in the vaccine formulation. Various compounds derived from pathogens, minerals or plants, possess pro-inflammatory properties which allow them to act as adjuvants and contribute to the induction of an effective immune response. The results presented here demonstrate the adjuvant properties of novel saponins derived from the Spanish saffron Crocus sativus. In vivo immunization studies and tumor protection experiments unambiguously establish the value of saffron saponins as candidate adjuvants. These saponins were indeed able to increase both humoral and cellular immune responses to protein-based vaccines, ultimately providing a significant degree of protection against tumor challenge when administered in combination with a tumor antigen. This preclinical study provides an in depth immunological characterization of a new saponin as a vaccine adjuvant, and encourages its further development for use in vaccine formulations.
Resumo:
The activity of radiopharmaceuticals in nuclear medicine is measured before patient injection with radionuclide calibrators. In Switzerland, the general requirements for quality controls are defined in a federal ordinance and a directive of the Federal Office of Metrology (METAS) which require each instrument to be verified. A set of three gamma sources (Co-57, Cs-137 and Co-60) is used to verify the response of radionuclide calibrators in the gamma energy range of their use. A beta source, a mixture of (90)Sr and (90)Y in secular equilibrium, is used as well. Manufacturers are responsible for the calibration factors. The main goal of the study was to monitor the validity of the calibration factors by using two sources: a (90)Sr/(90)Y source and a (18)F source. The three types of commercial radionuclide calibrators tested do not have a calibration factor for the mixture but only for (90)Y. Activity measurements of a (90)Sr/(90)Y source with the (90)Y calibration factor are performed in order to correct for the extra-contribution of (90)Sr. The value of the correction factor was found to be 1.113 whereas Monte Carlo simulations of the radionuclide calibrators estimate the correction factor to be 1.117. Measurements with (18)F sources in a specific geometry are also performed. Since this radionuclide is widely used in Swiss hospitals equipped with PET and PET-CT, the metrology of the (18)F is very important. The (18)F response normalized to the (137)Cs response shows that the difference with a reference value does not exceed 3% for the three types of radionuclide calibrators.
Resumo:
While cell sorting usually relies on cell-surface protein markers, molecular beacons (MBs) offer the potential to sort cells based on the presence of any expressed mRNA and in principle could be extremely useful to sort rare cell populations from primary isolates. We show here how stem cells can be purified from mixed cell populations by sorting based on MBs. Specifically, we designed molecular beacons targeting Sox2, a well-known stem cell marker for murine embryonic (mES) and neural stem cells (NSC). One of our designed molecular beacons displayed an increase in fluorescence compared to a nonspecific molecular beacon both in vitro and in vivo when tested in mES and NSCs. We sorted Sox2-MB(+)SSEA1(+) cells from a mixed population of 4-day retinoic acid-treated mES cells and effectively isolated live undifferentiated stem cells. Additionally, Sox2-MB(+) cells isolated from primary mouse brains were sorted and generated neurospheres with higher efficiency than Sox2-MB(-) cells. These results demonstrate the utility of MBs for stem cell sorting in an mRNA-specific manner.
Resumo:
Needle-free procedures are very attractive ways to deliver vaccines because they diminish the risk of contamination and may reduce local reactions, pain or pain fear especially in young children with a consequence of increasing the vaccination coverage for the whole population. For this purpose, the possible development of a mucosal malaria vaccine was investigated. Intranasal immunization was performed in BALB/c mice using a well-studied Plasmodium berghei model antigen derived from the circumsporozoite protein with the modified heat-labile toxin of Escherichia coli (LTK63), which is devoid of any enzymatic activity compared to the wild type form. Here, we show that intranasal administration of the two compounds activates the T and B cell immune response locally and systemically. In addition, a total protection of mice is obtained upon a challenge with live sporozoites.
Resumo:
The results of numerous phases I and II clinical trials testing the safety and immunogenicity of various cancer vaccine formulations based on cytolytic T lymphocytes (CTLs)-defined tumor antigens have been reported recently. Specific T cell responses can be detected in only a fraction of immunized patients. A smaller but significant fraction of these patients have objective tumor responses. Efficient therapeutic vaccination should aim at boosting naturally occurring anti-tumor responses and at sustaining a large contingent of tumor antigen-specific and fully functional effector T cells at tumor sites.
Resumo:
BACKGROUND: By reducing the amount of nicotine that reaches the brain when a person smokes a cigarette, nicotine vaccines may help people to stop smoking or to prevent recent quitters from relapsing. OBJECTIVES: The aims of this review are to assess the efficacy of nicotine vaccines for smoking cessation and for relapse prevention, and to assess the frequency and type of adverse events associated with the use of nicotine vaccines. SEARCH METHODS: We searched the Cochrane Tobacco Addiction Review Group specialised register for trials, using the term 'vaccine' in the title or abstract, or in a keyword (date of most recent search April 2012). To identify any other material including reviews and papers potentially relevant to the background or discussion sections, we also searched MEDLINE, EMBASE, and PsycINFO, combining terms for nicotine vaccines with terms for smoking and tobacco use, without design limits or limits for human subjects. We searched the Annual Meeting abstracts of the Society for Research on Nicotine and Tobacco up to 2012, using the search string 'vaccin'. We searched Google Scholar for 'nicotine vaccine'. We also searched company websites and Google for information related to specific vaccines. We searched clinicaltrials.gov in March 2012 for 'nicotine vaccine' and for the trade names of known vaccine candidates. SELECTION CRITERIA: We included randomized controlled trials of nicotine vaccines, at Phase II and Phase III trial stage and beyond, in adult smokers or recent ex-smokers. We included studies of nicotine vaccines used as part of smoking cessation or relapse prevention interventions. DATA COLLECTION AND ANALYSIS: We extracted data on the type of participants, the dose and duration of treatment, the outcome measures, the randomization procedure, concealment of allocation, blinding of participants and personnel, reporting of outcomes, and completeness of follow-up.Our primary outcome measure was a minimum of six months abstinence from smoking. We used the most rigorous definition of abstinence, and preferred cessation rates at 12 months and biochemically validated rates where available. We have used the risk ratio (RR) to summarize individual trial outcomes. We have not pooled the current group of included studies as they cover different vaccines and variable regimens. MAIN RESULTS: There are no nicotine vaccines currently licensed for public use, but there are a number in development. We found four trials which met our inclusion criteria, three comparing NicVAX to placebo and one comparing NIC002 (formerly NicQbeta) to placebo. All were smoking cessation trials conducted by pharmaceutical companies as part of the drug development process, and all trials were judged to be at high or unclear risk of bias in at least one domain. Overall, 2642 smokers participated in the included studies in this review. None of the four included studies detected a statistically significant difference in long-term cessation between participants receiving vaccine and those receiving placebo. The RR for 12 month cessation in active and placebo groups was 1.35 (95% Confidence Interval (CI) 0.82 to 2.22) in the trial of NIC002 and 1.74 (95% CI 0.73 to 4.18) in one NicVAX trial. Two Phase III NicVAX trials, for which full results were not available, reported similar quit rates of approximately 11% in both groups. In the two studies with full results available, post hoc analyses detected higher cessation rates in participants with higher levels of nicotine antibodies, but these findings are not readily generalisable. The two studies with full results showed nicotine vaccines to be well tolerated, with the majority of adverse events classified as mild or moderate. In the study of NIC002, participants receiving the vaccine were more likely to report mild to moderate adverse events, most commonly flu-like symptoms, whereas in the study of NicVAX there was no significant difference between the two arms. Information on adverse events was not available for the large Phase III trials of NicVAX.Vaccine candidates are likely to undergo significant changes before becoming available to the general public, and those included in this review may not be the first to reach market; this limits the external validity of the results reported in this review in terms of both effectiveness and tolerability. AUTHORS' CONCLUSIONS: There is currently no evidence that nicotine vaccines enhance long-term smoking cessation. Rates of serious adverse events recorded in the two trials with full data available were low, and the majority of adverse events reported were at mild to moderate levels. The evidence available suggests nicotine vaccines do not induce compensatory smoking or affect withdrawal symptoms. No nicotine vaccines are currently licensed for use in any country but a number are under development.Further trials of nicotine vaccines are needed, comparing vaccines with placebo for smoking cessation. Further trials are also needed to explore the potential of nicotine vaccines to prevent relapse. Results from past, current and future research should be reported in full. Adverse events and serious adverse events should continue to be carefully monitored and thoroughly reported.
Resumo:
The CD8 T cell response generatedby gene-based vaccines is importantfor protective immunity againstmany infectious diseases but its complexityis incompletely understood.Here, we report that different vaccinesencoding HIV Env elicit qualitativelydistinct CD8 T cells that wereidentified by patterns of gene expressionin individual cells. Three alternativeprime-boost vector combinationsstimulated antigen-specific CD8 Tcell populations of similar magnitudeand function by intracellular cytokinestaining; however, single cell geneexpression profiling enabled the discriminationof distinct CM and EMCD8 cells elicited by the three vaccines.Two previously unrecognizedCD8 T cell subsets have been definedby their coexpression of Eomes,Cxcr3 and Ccr7; or Klrk1, Klrg1 andCcr5 in CM and EM cells respectively.
Resumo:
OBJECTIVES: To determine the risk of a Down syndrome (DS) live birth for women 45 years of age and over. METHODS: A meta-analysis of data from five published articles, 13 EUROCAT congenital anomaly population registers and two unpublished sources. RESULTS: Information was available on the number of DS live births occurring amongst 13,745 live births to women 45 years of age and over. Information was also available on DS pregnancies diagnosed prenatally that were subsequently terminated. These pregnancies were adjusted for expected fetal loss to estimate the number of live births that would have occurred in the absence of prenatal diagnoses, when a total of 471 DS live births were estimated to have occurred. The risk of a DS birth did not increase for women 45 years of age and over. The average risk was 34 per 1000 births (95% CI: 31-37). CONCLUSION: The risk of a DS live birth for women 45 years of age and over is considerably lower than has often been previously assumed. The most likely explanation is that women of this age are more likely to miscarry DS pregnancies than younger mothers.