34 resultados para Collagen and elastic fibres
Resumo:
PURPOSE: To localize collagen types I, III, and IV, laminin and fibronectin in the anterior human lens capsule. MATERIAL AND METHODS: Twenty-one anterior capsules were sampled by capsulorhexis during extracapsular cataract extraction (mean age 71.5). All capsules were labelled by an immunostaining specific for each antibodies. Immunostaining of four capsules was revealed with immunoperoxydase and seventeen using indirect immunofluorescence. RESULTS: Labelling of collagen types I and III was observed throughout the entire thickness of the capsule for each technique, the strongest labelling was found in the base of the epithelial cells with immunofluorescence. Collagen type IV was observed at the base of the epithelial cells whichever technique was used. Laminin could be detected in the inner layer of the capsule, using immunoperoxydase or immunofluorescence. No specific labelling was found for fibronectin using the two techniques. CONCLUSIONS: Different kinds of collagens have been found in capsules, more particularly the type III. The latter does not appear on other ocular basement membrane. Because of this uneven distribution in the capsule's thickness, each collagen might have a specific function.
Resumo:
A collaborative study on Raman spectroscopy and microspectrophotometry (MSP) was carried out by members of the ENFSI (European Network of Forensic Science Institutes) European Fibres Group (EFG) on different dyed cotton fabrics. The detection limits of the two methods were tested on two cotton sets with a dye concentration ranging from 0.5 to 0.005% (w/w). This survey shows that it is possible to detect the presence of dye in fibres with concentrations below that detectable by the traditional methods of light microscopy and microspectrophotometry (MSP). The MSP detection limit for the dyes used in this study was found to be a concentration of 0.5% (w/w). At this concentration, the fibres appear colourless with light microscopy. Raman spectroscopy clearly shows a higher potential to detect concentrations of dyes as low as 0.05% for the yellow dye RY145 and 0.005% for the blue dye RB221. This detection limit was found to depend both on the chemical composition of the dye itself and on the analytical conditions, particularly the laser wavelength. Furthermore, analysis of binary mixtures of dyes showed that while the minor dye was detected at 1.5% (w/w) (30% of the total dye concentration) using microspectrophotometry, it was detected at a level as low as 0.05% (w/w) (10% of the total dye concentration) using Raman spectroscopy. This work also highlights the importance of a flexible Raman instrument equipped with several lasers at different wavelengths for the analysis of dyed fibres. The operator and the set up of the analytical conditions are also of prime importance in order to obtain high quality spectra. Changing the laser wavelength is important to detect different dyes in a mixture.
Resumo:
The GH-2000 and GH-2004 projects have developed a method for detecting GH misuse based on measuring insulin-like growth factor-I (IGF-I) and the amino-terminal pro-peptide of type III collagen (P-III-NP). The objectives were to analyze more samples from elite athletes to improve the reliability of the decision limit estimates, to evaluate whether the existing decision limits needed revision, and to validate further non-radioisotopic assays for these markers. The study included 998 male and 931 female elite athletes. Blood samples were collected according to World Anti-Doping Agency (WADA) guidelines at various sporting events including the 2011 International Association of Athletics Federations (IAAF) World Athletics Championships in Daegu, South Korea. IGF-I was measured by the Immunotech A15729 IGF-I IRMA, the Immunodiagnostic Systems iSYS IGF-I assay and a recently developed mass spectrometry (LC-MS/MS) method. P-III-NP was measured by the Cisbio RIA-gnost P-III-P, Orion UniQ? PIIINP RIA and Siemens ADVIA Centaur P-III-NP assays. The GH-2000 score decision limits were developed using existing statistical techniques. Decision limits were determined using a specificity of 99.99% and an allowance for uncertainty because of the finite sample size. The revised Immunotech IGF-I - Orion P-III-NP assay combination decision limit did not change significantly following the addition of the new samples. The new decision limits are applied to currently available non-radioisotopic assays to measure IGF-I and P-III-NP in elite athletes, which should allow wider flexibility to implement the GH-2000 marker test for GH misuse while providing some resilience against manufacturer withdrawal or change of assays. Copyright © 2015 John Wiley & Sons, Ltd.
Resumo:
Le système nerveux périphérique est responsable de la transmission des impulses motrices, ainsi que de la réception des afférences sensorielles. Les lésions traumatiques des nerfs périphériques conduisent à une impotence fonctionnelle qui peut être dévastant, notamment chez les travailleurs manuels,. La récupération fonctionnelle est donc le but principal dans chirurgie des nerfs périphériques. Malheureusement, une suture directe des moignons nerveux est souvent impossible dans le contexte des traumatismes complexes qui surviennent lors des accidents. La suture nerveuse par interposition d'autogreffe reste le gold standard dans la pratique chirurgicale mais nécessite le sacrifice d'un nerf donneur, avec dysesthésie et possibles douleurs neuropathiques conséquentes. Alternativement, des guides tubulaires pour les nerfs peuvent être utilisées si le gap nerveux est inférieur à 3 cm. Plusieurs guides résorbables en collagène sont approuve en Europe et aux Etas Unis (FDA). Dans cette étude, des conduits de collagène ont été associe a des cellules régénératives (cellules souches adultes) comme stratégie supplémentaire de régénération. Une fois testé le rapport des cellules avec le biomatériau (NeuraGen® nerve guides) in vitro, une étude in vivo dans le rat a été effectuée. Les différents groupes de conduits ont été supplémentés respectivement avec Schwann cells (SC); avec cellules souches adultes dérivées de la moelle épinière, différentiées en cellules "Schwann-like" (dMSC); avec cellules souches adultes dérivées de la graisse, différentiées en cellules "Schwann-like" (dASC). Un groupe de conduits avec du milieu de culture sans cellules a été utilisé comme group control. Les conduits ont été utilisés pour combler un gap de 1cm dans un model de section totale du nerf sciatique chez le rat. Deux semaines post implantation, une analyse immuno-histochimique a été effectuée pour évaluer la régénération axonales et l'infiltration de cellules de Schwann au niveau du conduit. Les cellules ont montré une adhérence efficace aux parois de collagène. En particulier, les cellules de Schwann ont montré une amélioration significative au niveau du sprouting distale. Par contre, aucune différence significative n'a été remarquée entre les groupes pour le sprouting axonale proximal. De plus, si les cellules souches ont montré un pattern de sprouting diffus, les cellules de Schwann ont par contre garanti un cône de croissance typique, associé a une affinité remarquable pour les parois de collagène. NeuraGen® guides pourraient donc être un moyen adapté a l'association avec la thérapie cellulaire en raison de la bonne adhérence des cellules au biomatériau. Des modifications de surface dans le but d'améliorer la performance neurotrophique cellulaire in vivo (e.g. peptides de matrice extracellulaire) pourront être utilisées dans des applications futures.