120 resultados para Caries assessment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assessment of medical technologies has to answer several questions ranging from safety and effectiveness to complex economical, social, and health policy issues. The type of data needed to carry out such evaluation depends on the specific questions to be answered, as well as on the stage of development of a technology. Basically two types of data may be distinguished: (a) general demographic, administrative, or financial data which has been collected not specifically for technology assessment; (b) the data collected with respect either to a specific technology or to a disease or medical problem. On the basis of a pilot inquiry in Europe and bibliographic research, the following categories of type (b) data bases have been identified: registries, clinical data bases, banks of factual and bibliographic knowledge, and expert systems. Examples of each category are discussed briefly. The following aims for further research and practical goals are proposed: criteria for the minimal data set required, improvement to the registries and clinical data banks, and development of an international clearinghouse to enhance information diffusion on both existing data bases and available reports on medical technology assessments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Dynamic high-field magnetic resonance (MR) defecography including the evacuation phase is a promising tool for the assessment of functional pelvic disorders, nowadays seen with increasing frequency in elderly women in particular. Learning objectives: 1. To describe the adequate technique of dynamic high-field MRI (3T) in assessing pelvic floor disorders. 2. To provide an overview of the most common pathologies occurring during the evacuation phase, especially in comparison with results of conventional defecography. Methods and materials: After description of the ideal technical parameters of MR defecography performed in supine position after gel rectal filling with a 3 Tesla unit and including the evacuation phase we stress the importance of using a standardized evaluation system for the exact assessment of pelvic floor pathophysiology. Results: The typical pelvic floor disorders occurring before and/or during the evacuation phase, such as sphincter insufficiency, vaginal vault and/or uterine prolapse, cystourethrocele, peritoneo-/ entero-/ sigmoïdocele or rectal prolapse, are demonstrated. The difference between the terms "pelvic floor descent" and "pelvic floor relaxation" are pictorially outlined. MR results are compared with these of conventional defecography. Conclusion: Exact knowledge about the correct technique including the evacuation phase and the use of a standardized evaluation system in assessing pelvic floor disorders by dynamic high-field MRI is mandatory for accurate and reproducible diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The movement of the upper limbs (eg fidgeting-like activities) is a meaningful component of nonexercise activity thermogenesis (NEAT). This study examined the relationship between upper limb movements and whole body trunk movements, by simultaneously measuring energy expenditure during the course of the day. DESIGN: A cross-sectional study consisting of 88 subjects with a wide range in body mass index (17.3-32.5 kg/m(2)). The energy expenditure over a 24-h period was measured in a large respiratory chamber. The body movements were assessed by two uniaxial-accelerometers during daytime, one on the waist and the other on the dominant arm. The accelerometry scores from level 0 (=immobile) up to level 9 (=maximal intensity) were recorded. The activities of subjects were classified into eight categories: walking at two speeds on a horizontal treadmill (A & B), ambling (C), self-care tasks (D), desk work (E), meals (F), reading (G), watching TV (H). RESULTS: There was a significant relationship between the accelerometry scores from the waist (ACwaist) and that from the wrist (ACwrist) over the daytime period (R(2)=0.64; P<0.001). The ACwrist was systematically higher than the ACwaist during sedentary activities, whereas it was the reverse for walking activities. ACwrist to ACwaist ratio of activities E-H were above 1.0 and for walking activities (A-C) were below 1.0. A multiple regression analysis for predicting daytime energy expenditure revealed that the explained variance improved by 2% only when the ACwrist was added as a second predictor in addition to the ACwaist. This indicates that the effect of the ACwrist for predicting energy expenditure was of limited importance in our conditions of measurement. CONCLUSIONS: The acceleration of the upper limbs which includes fidgeting is more elevated than that of the whole body for sitting/lying down activities. However, their contribution to energy expenditure is lower than whole body trunk movements, thus indicating that the weight-bearing locomotion activities may be a key component of NEAT. However, its contribution may depend on the total duration of the upper limb movements during the course of the day.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study describes the validation of a new wearable system for assessment of 3D spatial parameters of gait. The new method is based on the detection of temporal parameters, coupled to optimized fusion and de-drifted integration of inertial signals. Composed of two wirelesses inertial modules attached on feet, the system provides stride length, stride velocity, foot clearance, and turning angle parameters at each gait cycle, based on the computation of 3D foot kinematics. Accuracy and precision of the proposed system were compared to an optical motion capture system as reference. Its repeatability across measurements (test-retest reliability) was also evaluated. Measurements were performed in 10 young (mean age 26.1±2.8 years) and 10 elderly volunteers (mean age 71.6±4.6 years) who were asked to perform U-shaped and 8-shaped walking trials, and then a 6-min walking test (6MWT). A total of 974 gait cycles were used to compare gait parameters with the reference system. Mean accuracy±precision was 1.5±6.8cm for stride length, 1.4±5.6cm/s for stride velocity, 1.9±2.0cm for foot clearance, and 1.6±6.1° for turning angle. Difference in gait performance was observed between young and elderly volunteers during the 6MWT particularly in foot clearance. The proposed method allows to analyze various aspects of gait, including turns, gait initiation and termination, or inter-cycle variability. The system is lightweight, easy to wear and use, and suitable for clinical application requiring objective evaluation of gait outside of the lab environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Meta-analysis of prospective studies shows that quantitative ultrasound of the heel using validated devices predicts risk of different types of fracture with similar performance across different devices and in elderly men and women. These predictions are independent of the risk estimates from hip DXA measures.Introduction Clinical utilisation of heel quantitative ultrasound (QUS) depends on its power to predict clinical fractures. This is particularly important in settings that have no access to DXA-derived bone density measurements. We aimed to assess the predictive power of heel QUS for fractures using a meta-analysis approach.Methods We conducted an inverse variance random effects meta-analysis of prospective studies with heel QUS measures at baseline and fracture outcomes in their follow-up. Relative risks (RR) per standard deviation (SD) of different QUS parameters (broadband ultrasound attenuation [BUA], speed of sound [SOS], stiffness index [SI], and quantitative ultrasound index [QUI]) for various fracture outcomes (hip, vertebral, any clinical, any osteoporotic and major osteoporotic fractures) were reported based on study questions.Results Twenty-one studies including 55,164 women and 13,742 men were included in the meta-analysis with a total follow-up of 279,124 person-years. All four QUS parameters were associated with risk of different fracture. For instance, RR of hip fracture for 1 SD decrease of BUA was 1.69 (95% CI 1.43-2.00), SOS was 1.96 (95% CI 1.64-2.34), SI was 2.26 (95%CI 1.71-2.99) and QUI was 1.99 (95% CI 1.49-2.67). There was marked heterogeneity among studies on hip and any clinical fractures but no evidence of publication bias amongst them. Validated devices from different manufacturers predicted fracture risks with similar performance (meta-regression p values > 0.05 for difference of devices). QUS measures predicted fracture with a similar performance in men and women. Meta-analysis of studies with QUS measures adjusted for hip BMD showed a significant and independent association with fracture risk (RR/SD for BUA = 1.34 [95%CI 1.22-1.49]).Conclusions This study confirms that heel QUS, using validated devices, predicts risk of different fracture outcomes in elderly men and women. Further research is needed for more widespread utilisation of the heel QUS in clinical settings across the world.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the past twenty years, various instruments have been developed for the assessment of substance use in adolescents, mainly in the United States. However, few of them have been adapted to, and validated in, French-speaking populations. Consequently, although increasing alcohol and drug use among teenagers has become a major concern, the various health and social programs developed in response to this specific problem have received little attention with regard to follow-up and outcome assessment. A standardized multidimensional assessment instrument adapted for adolescents is needed to assess the individual needs of adolescents and assign them to the most appropriate treatment setting, to provide a single measurement within and across health and social systems, and to conduct treatment outcome evaluations. Moreover, having an available instrument makes it possible to develop longitudinal and transcultural research studies. For this reason, a French version of the Adolescent Drug Abuse Diagnosis (ADAD) was developed and validated at the University Child and Adolescent Psychiatric Clinic in Lausanne, Switzerland. This article aims to discuss the methodological issues that we faced when using the ADAD instrument in a 4-year longitudinal study including adolescent substance users. Methodological aspects relating to the content and format of the instrument, the assessment administration and the statistical analyses are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this pilot study was to describe problems in functioning and associated rehabilitation needs in persons with spinal cord injury after the 2010 earthquake in Haiti by applying a newly developed tool based on the International Classification of Functioning, Disability and Health (ICF). DESIGN: Pilot study. SUBJECTS: Eighteen persons with spinal cord injury (11 women, 7 men) participated in the needs assessment. Eleven patients had complete lesions (American Spinal Injury Association Impairment Scale; AIS A), one patient had tetraplegia. METHODS: Data collection included information from the International Spinal Cord Injury Core Data Set and a newly developed needs assessment tool based on ICF Core Sets. This tool assesses the level of functioning, the corresponding rehabilitation need, and required health professional. Data were summarized using descriptive statistics. RESULTS: In body functions and body structures, patients showed typical problems following spinal cord injury. Nearly all patients showed limitations and restrictions in their activities and participation related to mobility, self-care and aspects of social integration. Several environmental factors presented barriers to these limitations and restrictions. However, the availability of products and social support were identified as facilitators. Rehabilitation needs were identified in nearly all aspects of functioning. To address these needs, a multidisciplinary approach would be needed. CONCLUSION: This ICF-based needs assessment provided useful information for rehabilitation planning in the context of natural disaster. Future studies are required to test and, if necessary, adapt the assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In patients with malignant pleural mesothelioma undergoing a multimodality therapy, treatment toxicity may outweigh the benefit of progression-free survival. The subjective experience across different treatment phases is an important clinical outcome. This study compares a standard with an individual quality of life (QoL) measure used in a multi-center phase II trial. PATIENTS AND METHODS: Sixty-one patients with stage I-III technically operable pleural mesothelioma were treated with preoperative chemotherapy, followed by pleuropneumonectomy and subsequent radiotherapy. QoL was assessed at baseline, at day 1 of cycle 3, and 1, 3 and 6 months post-surgery by using the Rotterdam Symptom Checklist (RSCL) and the Schedule for the Evaluation of Quality of Life-Direct Weighting (SEIQoL-DW), a measure that is based on five individually nominated and weighted QoL-domains. RESULTS: Completion rates were 98% (RSCL) and 92% (SEIQoL) at baseline and 98%/89% at cycle 3, respectively. Of the operated patients (N=45) RSCL and SEIQoL were available from 86%/72%, 93%/74%, and 94%/76% at months 1, 3, and 6 post-surgery. Average assessment time for the SEIQoL was 24min compared to 8min needed for the RSCL. Median changes from baseline indicate that both RSCL QoL overall score and SEIQoL index remained stable during chemotherapy with a clinically significant deterioration (change>or=8 points) 1 month after surgery (median change of -66 and -14 for RSCL and SEIQoL, respectively). RSCL QoL overall scores improved thereafter, but remained beneath baseline level until 6 months after surgery. SEIQoL scores improved to baseline-level at month 3 after surgery, but worsened again at month 6. RSCL QoL overall score and SEIQoL index were moderately correlated at baseline (r=.30; p<or=.05) and at 6-month follow-up (r=.42; p<or=.05) but not at the other time points. CONCLUSION: The SEIQoL assessment seems to be feasible within a phase II clinical trial, but may require more effort from staff. More distinctive QoL changes in accordance with clinical changes were measured with the RSCL. Our findings suggest that the two measures are not interchangeable: the RSCL is to favor when mainly information related to the course of disease- and treatment is of interest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared adherence (persistence and execution) during pregnancy and postpartum in HIV-positive women having taken part in the adherence-enhancing program of the Community Pharmacy of the Department of Ambulatory Care and Community Medicine in Lausanne between 2004 and 2012. This interdisciplinary program combined electronic drug monitoring and semi-structured, repeated motivational interviews. This was a retrospective, observational study. Observation period spread over from first adherence visit after last menstruation until 6 months after childbirth. Medication-taking was recorded by electronic drug monitoring. Socio-demographic and delivery data were collected from Swiss HIV Cohort database. Adherence data, barriers and facilitators were collected from pharmacy database. Electronic data were reconciled with pill-count and interview notes in order to include reported pocket-doses. Execution was analyzed over 3-day periods by a mixed effect logistic model, separating time before and after childbirth. This model allowed us to estimate different time slopes for both periods and to show a sudden fall associated with childbirth. Twenty-five pregnant women were included. Median age was 29 (IQR: 26.5, 32.0), women were in majority black (n_17,68%) and took a cART combining protease and nucleoside reverse transcriptase inhibitors (n_24,96%). Eleven women (44%) were ART-naı¨ve at the beginning of pregnancy. Twenty women (80%) were included in the program because of pregnancy. Women were included at all stages of pregnancy. Six women (24%) stopped the program during pregnancy, 3 (12%) at delivery, 4 (16%) during postpartum and 12 (48%) stayed in program at the end of observation time. Median number of visits was 4 (3.0, 6.3) during pregnancy and 3 (0.8, 6.0) during postpartum. Execution was continuously high during pregnancy, low at beginning of postpartum and increased gradually during the 6 months of postpartum. Major barriers to adherence were medication adverse events and difficulties in daily routine. Facilitators were motivation for promoting child-health and social support. The dramatic drop and very slow increase in cART adherence during postpartum might result in viral rebound and drug resistance. Although much attention is devoted to pregnant women, interdisciplinary care should also be provided to women in the community during first trimester of postpartum to support them in sustaining cART adherence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cannula design is of prime importance for venous drainage during cardiopulmonary bypass (CPB). To evaluate cannulas intended for CPB, an in vitro circuit was set up with silicone tubing between the test cannula encased in a movable preload reservoir and another static reservoir. The pressure-drop (DeltaP) value (P-drainage - P-preload) was measured using Millar pressure transducers. Flow rate (Q) was measured using an ultrasound flowmeter. Data display and data recording were controlled using a LabView application, custom made particularly for our experiments. Our results demonstrated that DeltaP, Q, and cannula resistance (DeltaP/Q) values were significantly decreased when the cannula diameter was increased for Smart and Medtronic cannulas. Smartcanula showed 36% and 43% less resistance compared to Medtronic venous and Medtronic femoral cannulas, respectively. The cannula shape (straight- or curved-tips) did not affect the DLP cannula resistance. Out of five cannulas tested, the Smartcanula outperforms the other commercially available cannulas. The mean (DeltaP/Q) values were 3.3 +/- 0.08, 4.07 +/- 0.08, 5.58 +/- 0.10, 5.74 +/- 0.15, and 6.45 +/- 0.15 for Smart, Medtronic, Edwards, Sarns, and Gambro cannulas, respectively (two-way ANOVA, p < 0.0001). In conclusion, the present assay allows discrimination between different forms of cannula with high or low lumen resistance.