56 resultados para CROSS-VALIDATION
ASTRAL-R score predicts non-recanalisation after intravenous thrombolysis in acute ischaemic stroke.
Resumo:
Intravenous thrombolysis (IVT) as treatment in acute ischaemic strokes may be insufficient to achieve recanalisation in certain patients. Predicting probability of non-recanalisation after IVT may have the potential to influence patient selection to more aggressive management strategies. We aimed at deriving and internally validating a predictive score for post-thrombolytic non-recanalisation, using clinical and radiological variables. In thrombolysis registries from four Swiss academic stroke centres (Lausanne, Bern, Basel and Geneva), patients were selected with large arterial occlusion on acute imaging and with repeated arterial assessment at 24 hours. Based on a logistic regression analysis, an integer-based score for each covariate of the fitted multivariate model was generated. Performance of integer-based predictive model was assessed by bootstrapping available data and cross validation (delete-d method). In 599 thrombolysed strokes, five variables were identified as independent predictors of absence of recanalisation: Acute glucose > 7 mmol/l (A), significant extracranial vessel STenosis (ST), decreased Range of visual fields (R), large Arterial occlusion (A) and decreased Level of consciousness (L). All variables were weighted 1, except for (L) which obtained 2 points based on β-coefficients on the logistic scale. ASTRAL-R scores 0, 3 and 6 corresponded to non-recanalisation probabilities of 18, 44 and 74 % respectively. Predictive ability showed AUC of 0.66 (95 %CI, 0.61-0.70) when using bootstrap and 0.66 (0.63-0.68) when using delete-d cross validation. In conclusion, the 5-item ASTRAL-R score moderately predicts non-recanalisation at 24 hours in thrombolysed ischaemic strokes. If its performance can be confirmed by external validation and its clinical usefulness can be proven, the score may influence patient selection for more aggressive revascularisation strategies in routine clinical practice.
Resumo:
Free induction decay (FID) navigators were found to qualitatively detect rigid-body head movements, yet it is unknown to what extent they can provide quantitative motion estimates. Here, we acquired FID navigators at different sampling rates and simultaneously measured head movements using a highly accurate optical motion tracking system. This strategy allowed us to estimate the accuracy and precision of FID navigators for quantification of rigid-body head movements. Five subjects were scanned with a 32-channel head coil array on a clinical 3T MR scanner during several resting and guided head movement periods. For each subject we trained a linear regression model based on FID navigator and optical motion tracking signals. FID-based motion model accuracy and precision was evaluated using cross-validation. FID-based prediction of rigid-body head motion was found to be with a mean translational and rotational error of 0.14±0.21 mm and 0.08±0.13(°) , respectively. Robust model training with sub-millimeter and sub-degree accuracy could be achieved using 100 data points with motion magnitudes of ±2 mm and ±1(°) for translation and rotation. The obtained linear models appeared to be subject-specific as inter-subject application of a "universal" FID-based motion model resulted in poor prediction accuracy. The results show that substantial rigid-body motion information is encoded in FID navigator signal time courses. Although, the applied method currently requires the simultaneous acquisition of FID signals and optical tracking data, the findings suggest that multi-channel FID navigators have a potential to complement existing tracking technologies for accurate rigid-body motion detection and correction in MRI.
Resumo:
OBJECTIVE: To develop predictive models for early triage of burn patients based on hypersusceptibility to repeated infections. BACKGROUND: Infection remains a major cause of mortality and morbidity after severe trauma, demanding new strategies to combat infections. Models for infection prediction are lacking. METHODS: Secondary analysis of 459 burn patients (≥16 years old) with 20% or more total body surface area burns recruited from 6 US burn centers. We compared blood transcriptomes with a 180-hour cutoff on the injury-to-transcriptome interval of 47 patients (≤1 infection episode) to those of 66 hypersusceptible patients [multiple (≥2) infection episodes (MIE)]. We used LASSO regression to select biomarkers and multivariate logistic regression to built models, accuracy of which were assessed by area under receiver operating characteristic curve (AUROC) and cross-validation. RESULTS: Three predictive models were developed using covariates of (1) clinical characteristics; (2) expression profiles of 14 genomic probes; (3) combining (1) and (2). The genomic and clinical models were highly predictive of MIE status [AUROCGenomic = 0.946 (95% CI: 0.906-0.986); AUROCClinical = 0.864 (CI: 0.794-0.933); AUROCGenomic/AUROCClinical P = 0.044]. Combined model has an increased AUROCCombined of 0.967 (CI: 0.940-0.993) compared with the individual models (AUROCCombined/AUROCClinical P = 0.0069). Hypersusceptible patients show early alterations in immune-related signaling pathways, epigenetic modulation, and chromatin remodeling. CONCLUSIONS: Early triage of burn patients more susceptible to infections can be made using clinical characteristics and/or genomic signatures. Genomic signature suggests new insights into the pathophysiology of hypersusceptibility to infection may lead to novel potential therapeutic or prophylactic targets.
Resumo:
OBJECTIVES: Different accelerometer cutpoints used by different researchers often yields vastly different estimates of moderate-to-vigorous intensity physical activity (MVPA). This is recognized as cutpoint non-equivalence (CNE), which reduces the ability to accurately compare youth MVPA across studies. The objective of this research is to develop a cutpoint conversion system that standardizes minutes of MVPA for six different sets of published cutpoints. DESIGN: Secondary data analysis. METHODS: Data from the International Children's Accelerometer Database (ICAD; Spring 2014) consisting of 43,112 Actigraph accelerometer data files from 21 worldwide studies (children 3-18 years, 61.5% female) were used to develop prediction equations for six sets of published cutpoints. Linear and non-linear modeling, using a leave one out cross-validation technique, was employed to develop equations to convert MVPA from one set of cutpoints into another. Bland Altman plots illustrate the agreement between actual MVPA and predicted MVPA values. RESULTS: Across the total sample, mean MVPA ranged from 29.7MVPAmind(-1) (Puyau) to 126.1MVPAmind(-1) (Freedson 3 METs). Across conversion equations, median absolute percent error was 12.6% (range: 1.3 to 30.1) and the proportion of variance explained ranged from 66.7% to 99.8%. Mean difference for the best performing prediction equation (VC from EV) was -0.110mind(-1) (limits of agreement (LOA), -2.623 to 2.402). The mean difference for the worst performing prediction equation (FR3 from PY) was 34.76mind(-1) (LOA, -60.392 to 129.910). CONCLUSIONS: For six different sets of published cutpoints, the use of this equating system can assist individuals attempting to synthesize the growing body of literature on Actigraph, accelerometry-derived MVPA.
Resumo:
AIM: The aim of this study was to interpret and validate a French version of the Oswestry disability index (ODI), using a cross-cultural validation method. The validity and reliability of the questionnaire was assessed in order to ensure the psychometric characteristics. METHOD: The cross-cultural validation was carried out according to Beaton's methodology. The study was conducted with 41 patients suffering from low back pain. The correlation between the ODI and the Roland-Morris disability questionnaire (RMDQ), the medical outcome survey short form-36 (MOS SF-36) and a pain visual analogical scale (VAS) was assessed. RESULTS: The validity of the Oswestry questionnaire was studied using the Cronbach Alpha coefficient calculation: 0.87 (n=36). The significant correlation between the ODI and RMDQ was 0.8 (P<0.001, n=41) and 0.71 (P<0.001, n=36) for the pain VAS. The correlation between the ODI and certain subscales (physical functioning 0.7 (P<0.001, n=41), physical role 0.49 et bodily pain 0.73 (P<0.001, n=41)) of the MOS SF-36 were equally significant. The reproducibility of the ODI was calculated using the Wilcoxon matched pairs test: there was no significant difference for eight out of ten sections or for the final score. CONCLUSION: This French translation of the ODI should be considered as valid and reliable. It should be used for any future clinical studies carried out using French language patients. Complimentary studies must be completed in order to assess its sensitivity to change in the event of any modifications in the patients functional capacity.
Resumo:
Introduction Functional subjective evaluation through questionnaire is fundamental, but not often realized in patients with back complaints, lacking validated tools. The Spinal Function Sort (SFS) was only validated in English. We aimed to translate, adapt and validate the French (SFS-F) and German (SFS-G) versions of the SFS. Methods Three hundred and forty-four patients, experiencing various back complaints, were recruited in a French (n = 87) and a German-speaking (n = 257) center. Construct validity was estimated via correlations with SF-36 physical and mental scales, pain intensity and hospital anxiety and depression scales (HADS). Scale homogeneities were assessed by Cronbach's α. Test-retest reliability was assessed on 65 additional patients using intraclass correlation (IC). Results For the French and German translations, respectively, α were 0.98 and 0.98; IC 0.98 (95% CI: [0.97; 1.00]) and 0.94 (0.90; 0.98). Correlations with physical functioning were 0.63 (0.48; 0.74) and 0.67 (0.59; 0.73); with physical summary 0.60 (0.44; 0.72) and 0.52 (0.43; 0.61); with pain -0.33 (-0.51; -0.13) and -0.51 (-0.60; -0.42); with mental health -0.08 (-0.29; 0.14) and 0.25 (0.13; 0.36); with mental summary 0.01 (-0.21; 0.23) and 0.28 (0.16; 0.39); with depression -0.26 (-0.45; -0.05) and -0.42 (-0.52; -0.32); with anxiety -0.17 (-0.37; -0.04) and -0.45 (-0.54; -0.35). Conclusions Reliability was excellent for both languages. Convergent validity was good with SF-36 physical scales, moderate with VAS pain. Divergent validity was low with SF-36 mental scales in both translated versions and with HADS for the SFS-F (moderate in SFS-G). Both versions seem to be valid and reliable for evaluating perceived functional capacity in patients with back complaints.
Resumo:
Aim: Functional subjective evaluation through questionnaire is fundamental, but not often realized in patients with back complaints, notably because of lack of validated tools, in accordance with recognized psychometric criteria. The Spinal Function Sort (SFS), developed according to actual standards, was only validated in English. The aim of this study is to translate, adapt and validate the French and German version of the SFS.Method and material: The translation and cross-cultural adaptation were performed following the methodology proposed by the American Association of Orthopedist Surgeon. A total of 344 patients, presenting varied back complaints (especially degenerative and traumatic), took part in this study in a tertiary French- (n=87; mean age 44y; 17 women) and German-speaking (n=257; mean age 41y; 53 women) center. Test-retest reliability was quantified using the intraclass correlation coefficient (ICC) and construct validity was assessed by estimating the Pearson's correlation with the SF-36 physical and mental scales, the Visual Analogue Scale for Pain Intensity (VAS), and subscales of the Hospital Anxiety and Depression Scale (HADS).Results: Respectively for the French and German version, ICC were 0.98 and 0.94. Correlations 0.63 and 0.67 with the SF-36 Physical Functioning subscale; 0.60 and 0.52 with the SF-36 Physical Summary Scale ; -0.33 and -0.51 with the VAS ; -0.08 and 0.25 with the SF-36 Mental Health scale; 0.01 and 0.28 with the SF-36 Mental Summary Scale; -0.26 and -0.42 with the HADS depression; -0.17 and -0.45 with the HADS anxiety.Discussion: For both the French and German version of the SFS, the reliability was excellent. Convergent construct validity with SF-36 physical scales is good, moderated with the VAS. We find out a low correlation with SF-36 mental scales (divergent construct validity). We find out a low correlation with HADS subscales in the French version, and a moderate one in the German version. Selection bias, chronicity of the complaints, as well as cultural differences could explain these results. In conclusion, both the French and German version of the SFS are valid and reliable for evaluation of perceived functional capacity for patients with back complaints.
Resumo:
OBJECTIVE: The aim of the study was to validate a French adaptation of the 5th version of the Addiction Severity Index (ASI) instrument in a Swiss sample of illicit drug users. PARTICIPANTS AND SETTING: The participants in the study were 54 French-speaking dependent patients, most of them with opiates as the drug of first choice. Procedure: Analyses of internal consistency (convergent and discriminant validity) and reliability, including measures of test-retest and inter-observer correlations, were conducted. RESULTS: Besides good applicability of the test, the results on composite scores (CSs) indicate comparable results to those obtained in a sample of American opiate-dependent patients. Across the seven dimensions of the ASI, Cronbach's alpha ranged from 0.42 to 0.76, test-retest correlations coefficients ranged from 0.48 to 0.98, while for CSs, inter-observer correlations ranged from 0.76 to 0.99. CONCLUSIONS: Despite several limitations, the French version of the ASI presents acceptable criteria of applicability, validity and reliability in a sample of drug-dependent patients.
Resumo:
The study was designed to investigate the psychometric properties of the French version and the cross-language replicability of the Hierarchical Personality Inventory for Children (HiPIC). The HiPIC is an instrument aimed at assessing the five dimensions of the Five-Factor Model for Children. Subjects were 552 children aged between 8 and 12 years, rated by one or both parents. At the domain level, reliability ranged from .83 to .93 and at the facet level, reliability ranged from .69 to .89. Differences between genders were congruent with those found in the Dutch sample. Girls scored higher on Benevolence and Conscientiousness. Age was negatively correlated with Extraversion and Imagination. For girls, we also observed a decrease of Emotional Stability. A series of exploratory factor analyses confirmed the overall five-factor structure for girls and boys. Targeted factor analyses and congruence coefficients revealed high cross-language replicability at the domain and at the facet levels. The results showed that the French version of the HiPIC is a reliable and valid instrument for assessing personality with children and has a particularly high cross-language replicability.
Resumo:
L'objectif de l'étude présentée est d'adapter et de valider une version française de la Stigma Scale (King, 2007) auprès d'une population de personnes souffrant de troubles psychiques. Dans une première phase, la stabilité temporelle (fidélité test-retest), la cohérence interne et la validité convergente de l'instrument original à 28 items traduit en français ont été évaluées auprès d'un échantillon de 183 patients. Les résultats d'analyses factorielles confirmatoires ne nous ont pas permis de confirmer la structure originale de l'instrument. Nous avons donc proposé, sur la base des résultats d'une analyse factorielle exploratoire, une version courte de l'échelle de stigmatisation (9 items) qui conserve la structure en trois facteurs du modèle original. Dans une deuxième phase, nous avons examiné les qualités psychométriques et validé cette version abrégée de l'échelle de stigmatisation auprès d'un second échantillon de 234 patients. Les indices d'ajustements de notre analyse factorielle confirmatoire confirme la structure en trois facteurs de la version abrégée de la Stigma Scale. Les résultats suggèrent que la version française abrégée de l'échelle de stigmatisation constitue un instrument utile, fiable et valide dans l'autoévaluation de la stigmatisation perçue par des personnes souffrant de troubles psychiques. - Aim People suffering from mental illness are exposed to stigma. However, only few tools are available to assess stigmatization as perceived from the patient's perspective. The aim of this study is to adapt and validate a French version of the Stigma Scale (King, 2007). This self-report questionnaire has a three-factor structure: discrimination, disclosure and positive aspects of mental illness. Discrimination subscale refers to perceived negative reactions by others. Disclosure subscale refers mainly to managing disclosure to avoid discrimination and finally positive aspects subscale taps into how patients are becoming more accepting, more understanding toward their illness. Method In the first step, internal consistency, convergent validity and test-retest reliability of the French adaptation of the 28-item scale have been assessed on a sample of 183 patients. Results of confirmatory factor analyses (CFA) did not confirm the hypothesized structure. In light of the failed attempts to validate the original version, an alternative 9-item short-form version of the Stigma Scale, maintaining the integrity of the original model, was developed based on results of exploratory factor analyses in the first sample and cross- validated in a new sample of 234 patients. Results Results of CFA did not confirm that the data fitted well to the three-factor model of the 28-item Stigma Scale (χ2/άί=2.02, GFI=0.77, AGFI=0.73, RMSEA=0.07, CFI=0.77 et NNFI=0.75). Cronbach's α are excellent for discrimination (0.84) and disclosure (0.83) subscales but poor for potential positive aspects (0.46). External validity is satisfactory. Overall Stigma Scale total score is negatively correlated with score on Rosenberg's Self-Esteem Scale (r = -0.49), and each sub-scale is significantly correlated with a visual analogue scale that refers to the specific aspect of stigma (0.43 < |r| < 0.60). Intraclass correlation coefficients between 0.68 and 0.89 indicate good test- retest reliability. Results of CFA demonstrate that the items chosen for the short version of the Stigma Scale have the expected fit properties fa2/df=1.02, GFI=0.98, AGFI=0.98, RMSEA=0.01, CFI=1.0 et NNFI=1.0). Considering the small number (3 items) of items in each subscales of the short version of the Stigma Scale, a coefficients for the discrimination (0.57), disclosure (0.80) and potential positive aspects subscales (0.62) are considered as good. Conclusion Our results suggest that the 9-item French short-version of the Stigma Scale is a useful, reliable and valid self-report questionnaire to assess perceived stigmatization in people suffering from mental illness. The time of completion is really short and questions are well understood and accepted by the patients.
Resumo:
OBJECTIVE: To determine the psychometric properties of an adapted version of the Falls Efficacy Scale (FES) in older rehabilitation patients. DESIGN: Cross-sectional survey. SETTING: Postacute rehabilitation facility in Switzerland. PARTICIPANTS: Seventy elderly persons aged 65 years and older receiving postacute, inpatient rehabilitation. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: FES questions asked about subject's confidence (range, 0 [none]-10 [full]) in performing 12 activities of daily living (ADLs) without falling. Construct validity was assessed using correlation with measures of physical (basic ADLs [BADLs]), cognitive (Mini-Mental State Examination [MMSE]), affective (15-item Geriatric Depression Scale [GDS]), and mobility (Performance Oriented Mobility Assessment [POMA]) performance. Predictive validity was assessed using the length of rehabilitation stay as the outcome. To determine test-retest reliability, FES administration was repeated in a random subsample (n=20) within 72 hours. RESULTS: FES scores ranged from 10 to 120 (mean, 88.7+/-26.5). Internal consistency was optimal (Cronbach alpha=.90), and item-to-total correlations were all significant, ranging from .56 (toilet use) to .82 (reaching into closets). Test-retest reliability was high (intraclass correlation coefficient, .97; 95% confidence interval, .95-.99; P<.001). Subjects reporting a fall in the previous year had lower FES scores than nonfallers (85.0+/-25.2 vs 94.4+/-27.9, P=.054). The FES correlated with POMA (Spearman rho=.40, P<.001), MMSE (rho=.37, P=.001), BADL (rho=.43, P<.001), and GDS (rho=-.53, P<.001) scores. These relationships remained significant in multivariable analysis for BADLs and GDS, confirming FES construct validity. There was a significant inverse relationship between FES score and the length of rehabilitation stay, independent of sociodemographic, functional, cognitive, and fall status. CONCLUSIONS: This adapted FES is reliable and valid in older patients undergoing postacute rehabilitation. The independent association between poor falls efficacy and increased length of stay has not been previously described and needs further investigations.
Resumo:
OBJECTIVE: The principal aim of this study was to develop a Swiss Food Frequency Questionnaire (FFQ) for the elderly population for use in a study to investigate the influence of nutritional factors on bone health. The secondary aim was to assess its validity and both short-term and long-term reproducibility. DESIGN: A 4-day weighed record (4 d WR) was applied to 51 randomly selected women of a mean age of 80.3 years. Subsequently, a detailed FFQ was developed, cross-validated against a further 44 4-d WR, and the short- (1 month, n = 15) and long-term (12 months, n = 14) reproducibility examined. SETTING: French speaking part of Switzerland. SUBJECTS: The subjects were randomly selected women recruited from the Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture cohort study. RESULTS: Mean energy intakes by 4-d WR and FFQ showed no significant difference [1564.9 kcal (SD 351.1); 1641.3 kcal (SD 523.2) respectively]. Mean crude nutrient intakes were also similar (with nonsignifcant P-values examining the differences in intake) and ranged from 0.13 (potassium) to 0.48 (magnesium). Similar results were found in the reproducibility studies. CONCLUSION: These findings provide evidence that this FFQ adequately estimates nutrient intakes and can be used to rank individuals within distributions of intake in specific populations.
Resumo:
The aim of the present study was to develop a short form of the Zuckerman-Kuhlman Personality Questionnaire (ZKPQ) with acceptable psychometric properties in four languages: English (United States), French (Switzerland), German (Germany), and Spanish (Spain). The total sample (N = 4,621) was randomly divided into calibration and validation samples. An exploratory factor analysis was conducted in the calibration sample. Eighty items, with loadings equal or higher than 0.30 on their own factor and lower on the remaining factors, were retained. A confirmatory factor analysis was performed over the survival items in the validation sample in order to select the best 10 items for each scale. This short version (named ZKPQ-50-CC) presents psychometric properties strongly similar to the original version in the four countries. Moreover, the factor structure are near equivalent across the four countries since the congruence indices were all higher than 0.90. It is concluded that the ZKPQ-50-CC presented a high cross-language replicability, and it could be an useful questionnaire that may be used for personality research.
Resumo:
Study design:Cross-sectional validation study.Objectives:To develop and validate a self-report version of the Spinal Cord Independence Measure (SCIM III).Setting:Two SCI rehabilitation facilities in Switzerland.Methods:SCIM III comprises 19 questions on daily tasks with a total score between 0 and 100 and subscales for 'self-care', 'respiration & sphincter management' and 'mobility'. A self-report version (SCIM-SR) was developed by expert discussions and pretests in individuals with spinal cord injury (SCI) using a German translation. A convenience sample of 99 inpatients with SCI was recruited. SCIM-SR data were analyzed together with SCIM III data obtained from attending health professionals.Results:High correlations between SCIM III and SCIM-SR were observed. Pearson's r for the total score was 0.87 (95% confidence interval (CI) 0.82-0.91), for the subscales self-care 0.87 (0.81-0.91); respiration & sphincter management 0.81 (0.73-0.87); and mobility 0.87 (0.82-0.91). Intraclass correlations were: total score 0.90 (95% CI 0.85-0.93); self-care 0.86 (0.79-0.90); respiration & sphincter management 0.80 (0.71-0.86); and mobility 0.83 (0.76-0.89). Bland-Altman plots showed that patients rated their functioning higher than professionals, in particular for mobility. The mean difference between SCIM-SR and SCIM III for the total score was 5.14 (point estimate 95% CI 2.95-7.34), self-care 0.89 (0.19-1.59), respiration & sphincter management 1.05 (0.18-2.28 ) and mobility 3.49 (2.44-4.54). Particularly patients readmitted because of pressure sores rated their independence higher than attending professionals.Conclusion:Our results support the criterion validity of SCIM-SR. The self-report version may facilitate long-term evaluations of independence in persons with SCI in their home situation.