49 resultados para CLINICIAN RATINGS OF VOICE QUALITY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An objective analysis of image quality parameters was performed for a computed radiography (CR) system using both standard single-side and prototype dual-side read plates. The pre-sampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of pediatric chest radiography, at an entrance detector air kerma of 5 microGy. The NPS and DQE measurements were realized under clinically relevant x-ray spectra for pediatric radiology, including x-ray scatter radiations. Compared to the standard single-side read system, the MTF for the dual-side read system is reduced, but this is offset by a significant decrease in image noise, resulting in a marked increase in DQE (+40%) in the low spatial frequency range. Thus, for the same image quality, the new technology permits the CR system to be used at a reduced dose level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Despite the increasing incidences of the publication of assessment frameworks intending to establish the "standards" of the quality of qualitative research, the research conducted using such empirical methods are still facing difficulties in being published or recognised by funding agencies. Methods: We conducted a thematic content analysis of eight frameworks from psychology/psychiatry and general medicine. The frameworks and their criteria are then compared against each other. Findings: The results illustrated the difficulties in reaching consensus on the definition of quality criteria. This showed the differences between the frameworks from the point of views of the underlying epistemology and the criteria suggested. Discussion: The aforementioned differences reflect the diversity of paradigms implicitly referred to by the authors of the frameworks, although rarely explicitly mentioned in text. We conclude that the increase in qualitative research and publications has failed to overcome the difficulties in establishing shared criteria and the great heterogeneity of concepts raises methodological and epistemological problems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Statistics of causes of death remain an important source of epidemiological data for the evaluation of various medical and health problems. The improvement of analytical techniques and, above all, the transformation of demographic and morbid structures of populations have prompted researchers in the field to give more importance to the quality of death certificates. After describing the data collection system presently used in Switzerland, the paper discusses various indirect estimations of the quality of Swiss data and reviews the corresponding international literature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gene expression data from microarrays are being applied to predict preclinical and clinical endpoints, but the reliability of these predictions has not been established. In the MAQC-II project, 36 independent teams analyzed six microarray data sets to generate predictive models for classifying a sample with respect to one of 13 endpoints indicative of lung or liver toxicity in rodents, or of breast cancer, multiple myeloma or neuroblastoma in humans. In total, >30,000 models were built using many combinations of analytical methods. The teams generated predictive models without knowing the biological meaning of some of the endpoints and, to mimic clinical reality, tested the models on data that had not been used for training. We found that model performance depended largely on the endpoint and team proficiency and that different approaches generated models of similar performance. The conclusions and recommendations from MAQC-II should be useful for regulatory agencies, study committees and independent investigators that evaluate methods for global gene expression analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The Internet is increasingly used as a source of information for mental health issues. The burden of obsessive compulsive disorder (OCD) may lead persons with diagnosed or undiagnosed OCD, and their relatives, to search for good quality information on the Web. This study aimed to evaluate the quality of Web-based information on English-language sites dealing with OCD and to compare the quality of websites found through a general and a medically specialized search engine. METHODS: Keywords related to OCD were entered into Google and OmniMedicalSearch. Websites were assessed on the basis of accountability, interactivity, readability, and content quality. The "Health on the Net" (HON) quality label and the Brief DISCERN scale score were used as possible content quality indicators. Of the 235 links identified, 53 websites were analyzed. RESULTS: The content quality of the OCD websites examined was relatively good. The use of a specialized search engine did not offer an advantage in finding websites with better content quality. A score ≥16 on the Brief DISCERN scale is associated with better content quality. CONCLUSION: This study shows the acceptability of the content quality of OCD websites. There is no advantage in searching for information with a specialized search engine rather than a general one. Practical implications: The Internet offers a number of high quality OCD websites. It remains critical, however, to have a provider-patient talk about the information found on the Web.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Cardiovascular magnetic resonance (CMR) has become a robust and important diagnostic imaging modality in cardiovascular medicine. However,insufficient image quality may compromise its diagnostic accuracy. No standardized criteria are available to assess the quality of CMR studies. We aimed todescribe and validate standardized criteria to evaluate the quality of CMR studies including: a) cine steady-state free precession, b) delayed gadoliniumenhancement, and c) adenosine stress first-pass perfusion. These criteria will serve for the assessment of the image quality in the setting of the Euro-CMR registry.METHOD AND MATERIALS: First, a total of 45 quality criteria were defined (35 qualitative criteria with a score from 0-3, and 10 quantitative criteria). Thequalitative score ranged from 0 to 105. The lower the qualitative score, the better the quality. The quantitative criteria were based on the absolute signal intensity (delayed enhancement) and on the signal increase (perfusion) of the anterior/posterior left ventricular wall after gadolinium injection. These criteria were then applied in 30 patients scanned with a 1.5T system and in 15 patients scanned with a 3.0T system. The examinations were jointly interpreted by 3 CMR experts and 1 study nurse. In these 45 patients the correlation between the results of the quality assessment obtained by the different readers was calculated.RESULTS: On the 1.5T machine, the mean quality score was 3.5. The mean difference between each pair of observers was 0.2 (5.7%) with a mean standarddeviation of 1.4. On the 3.0T machine, the mean quality score was 4.4. The mean difference between each pair of onservers was 0.3 (6.4%) with a meanstandard deviation of 1.6. The quantitative quality assessments between observers were well correlated for the 1.5T machine: R was between 0.78 and 0.99 (pCONCLUSION: The described criteria for the assessment of CMR image quality are robust and have a low inter-observer variability, especially on 1.5T systems.CLINICAL RELEVANCE/APPLICATION: These criteria will allow the standardization of CMR examinations. They will help to improve the overall quality ofexaminations and the comparison between clinical studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The EORTC 22043-30041 trial investigates the role of the addition of androgen suppression to post-operative radiotherapy in patients who have undergone radical prostatectomy. As part of the quality assurance of radiotherapy (QART) a Dummy Run (DR) procedure was performed. MATERIALS AND METHOD: The protocol included detailed and published delineation guidelines. Participating institutions digitally submitted radiotherapy treatment volumes and a treatment plan for a standard clinical case. Submissions were centrally reviewed using the VODCA software platform. RESULTS: Thirty-eight submissions from thirty-one institutions were reviewed. Six were accepted without comments. Twenty-three were accepted with comments on one or more items: target volume delineation (22), OAR delineation (23), planning and dosimetry (3) or treatment verification (1). Nine submissions were rejected requiring resubmission, seven for target volume delineation reasons alone. Intervention to highlight the importance of delineation guidelines was made prior to the entry of the first patient in the trial. After this, a lower percentage of resubmissions was required. CONCLUSIONS: The EORTC 22043-30041 Dummy Run highlights the need for timely and effective QART in clinical trials. The variation in target volume and OAR definition demonstrates that clinical guidelines and radiotherapy protocols are not a substitute for QART procedures. Early intervention in response to the Dummy Run improved protocol understanding.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: This study assessed whether breast cancer (BC) patients express similar levels of needs for equivalent severity of symptoms, functioning difficulties, or degrees of satisfaction with care aspects. BC patients who did (or not) report needs in spite of similar difficulties were identified among their sociodemographic or clinical characteristics. PATIENTS AND METHODS: Three hundred and eighty-four (73% response rate) BC patients recruited in ambulatory or surgery hospital services completed the European Organisation for Research and Treatment of Cancer Quality of Life questionnaire (EORTC QLQ)-C30 quality of life [health-related quality of life (HRQOL)], the EORTC IN-PATSAT32 (in-patient) or OUT-PATSAT35 (out-patient) satisfaction with care, and the supportive care needs survey short form 34-item (SCNS-SF34) measures. RESULTS: HRQOL or satisfaction with care scale scores explained 41%, 45%, 40% and 22% of variance in, respectively, psychological, physical/daily living needs, information/health system, and care/support needs (P < 0.001). BC patients' education level, having children, hospital service attendance, and anxiety/depression levels significantly predicted differences in psychological needs relative to corresponding difficulties (adjusted R(2) = 0.11). Medical history and anxiety/depression levels significantly predicted differences in information/health system needs relative to degrees of satisfaction with doctors, nurses, or radiotherapy technicians and general satisfaction (adjusted R(2) = 0.12). Unmet needs were most prevalent in the psychological domains across hospital services. CONCLUSIONS: Assessment of needs, HRQOL, and satisfaction with care highlights the subgroups of BC patients requiring better supportive care targeting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The quality of colon cleansing is a major determinant of quality of colonoscopy. To our knowledge, the impact of bowel preparation on the quality of colonoscopy has not been assessed prospectively in a large multicenter study. Therefore, this study assessed the factors that determine colon-cleansing quality and the impact of cleansing quality on the technical performance and diagnostic yield of colonoscopy. METHODS: Twenty-one centers from 11 countries participated in this prospective observational study. Colon-cleansing quality was assessed on a 5-point scale and was categorized on 3 levels. The clinical indication for colonoscopy, diagnoses, and technical parameters related to colonoscopy were recorded. RESULTS: A total of 5832 patients were included in the study (48.7% men, mean age 57.6 [15.9] years). Cleansing quality was lower in elderly patients and in patients in the hospital. Procedures in poorly prepared patients were longer, more difficult, and more often incomplete. The detection of polyps of any size depended on cleansing quality: odds ratio (OR) 1.73: 95% confidence interval (CI)[1.28, 2.36] for intermediate-quality compared with low-quality preparation; and OR 1.46: 95% CI[1.11, 1.93] for high-quality compared with low-quality preparation. For polyps >10 mm in size, corresponding ORs were 1.0 for low-quality cleansing, OR 1.83: 95% CI[1.11, 3.05] for intermediate-quality cleansing, and OR 1.72: 95% CI[1.11, 2.67] for high-quality cleansing. Cancers were not detected less frequently in the case of poor preparation. CONCLUSIONS: Cleansing quality critically determines quality, difficulty, speed, and completeness of colonoscopy, and is lower in hospitalized patients and patients with higher levels of comorbid conditions. The proportion of patients who undergo polypectomy increases with higher cleansing quality, whereas colon cancer detection does not seem to critically depend on the quality of bowel preparation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Cardiovascular magnetic resonance (CMR) has become an important diagnostic imaging modality in cardiovascular medicine. However, insufficient image quality may compromise its diagnostic accuracy. We aimed to describe and validate standardized criteria to evaluate a) cine steady-state free precession (SSFP), b) late gadolinium enhancement (LGE), and c) stress first-pass perfusion images. These criteria will serve for quality assessment in the setting of the Euro-CMR registry. METHODS: Thirty-five qualitative criteria were defined (scores 0-3) with lower scores indicating better image quality. In addition, quantitative parameters were measured yielding 2 additional quality criteria, i.e. signal-to-noise ratio (SNR) of non-infarcted myocardium (as a measure of correct signal nulling of healthy myocardium) for LGE and % signal increase during contrast medium first-pass for perfusion images. These qualitative and quantitative criteria were assessed in a total of 90 patients (60 patients scanned at our own institution at 1.5T (n=30) and 3T (n=30) and in 30 patients randomly chosen from the Euro-CMR registry examined at 1.5T). Analyses were performed by 2 SCMR level-3 experts, 1 trained study nurse, and 1 trained medical student. RESULTS: The global quality score was 6.7±4.6 (n=90, mean of 4 observers, maximum possible score 64), range 6.4-6.9 (p=0.76 between observers). It ranged from 4.0-4.3 for 1.5T (p=0.96 between observers), from 5.9-6.9 for 3T (p=0.33 between observers), and from 8.6-10.3 for the Euro-CMR cases (p=0.40 between observers). The inter- (n=4) and intra-observer (n=2) agreement for the global quality score, i.e. the percentage of assignments to the same quality tertile ranged from 80% to 88% and from 90% to 98%, respectively. The agreement for the quantitative assessment for LGE images (scores 0-2 for SNR <2, 2-5, >5, respectively) ranged from 78-84% for the entire population, and 70-93% at 1.5T, 64-88% at 3T, and 72-90% for the Euro-CMR cases. The agreement for perfusion images (scores 0-2 for %SI increase >200%, 100%-200%,<100%, respectively) ranged from 81-91% for the entire population, and 76-100% at 1.5T, 67-96% at 3T, and 62-90% for the Euro-CMR registry cases. The intra-class correlation coefficient for the global quality score was 0.83. CONCLUSIONS: The described criteria for the assessment of CMR image quality are robust with a good inter- and intra-observer agreement. Further research is needed to define the impact of image quality on the diagnostic and prognostic yield of CMR studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Velopharyngeal insufficiency (VPI) is a structural or functional trouble, which causes hypernasal speech. Velopharyngeal flaps, speech therapy and augmentation pharyngoplasty, using different implants, have all been used to address this trouble. We hereby present our results following rhinopharyngeal autologous fat injection in 18 patients with mild velopharyngeal insufficiency (12 soft palate clefts, 4 functional VPI, 2 myopathy). 28 injections were carried out between 2004 and 2007. The degree of hypernasal speech was evaluated pre- and postoperatively by a speech therapist and an ENT specialist and quantified by an acoustic nasometry (Kay Elemetrics). All patients were exhaustively treated with preoperative speech therapy (average, 8 years). The mean value of the nasalance score was 37% preoperatively and 23% postoperatively (p = 0.015). The hypernasality was reduced postoperatively in all patients (1-3 degrees of the Borel-Maisonny score). There were no major complications, two minor complications (one hematoma, one cervical pain). The autologous fat injection is a simple, safe, minimally invasive procedure. It proves to be efficient in cases of mild velopharyngeal insufficiency or after a suboptimal velopharyngoplasty.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper outlines the approach that the WHO's Family of International Classifications (WHO-FIC) network is undertaking to create ICD-11. We also outline the more focused work of the Quality and Safety Topic Advisory Group, whose activities include the following: (i) cataloguing existing ICD-9 and ICD-10 quality and safety indicators; (ii) reviewing ICD morbidity coding rules for main condition, diagnosis timing, numbers of diagnosis fields and diagnosis clustering; (iii) substantial restructuring of the health-care related injury concepts coded in the ICD-10 chapters 19/20, (iv) mapping of ICD-11 quality and safety concepts to the information model of the WHO's International Classification for Patient Safety and the AHRQ Common Formats; (v) the review of vertical chapter content in all chapters of the ICD-11 beta version and (vi) downstream field testing of ICD-11 prior to its official 2015 release. The transition from ICD-10 to ICD-11 promises to produce an enhanced classification that will have better potential to capture important concepts relevant to measuring health system safety and quality-an important use case for the classification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To delineate the various factors contributing to failure or delay in decannulation after partial cricotracheal resection (PCTR) in children. STUDY DESIGN: Case series. SETTING: Academic tertiary medical center. SUBJECTS AND METHODS: A retrospective case review of 100 children who underwent PCTR between 1978 and 2008 for severe subglottic stenosis using an ongoing database. RESULTS: Ninety of 100 (90%) patients were decannulated. Six patients needed secondary tracheostomy. The results of the preoperative evaluation showed grade II stenosis in four patients, grade III in 64 patients, and grade IV in 32 patients. The overall decannulation rate was 100 percent in grade II, 95 percent in grade III, and 78 percent in grade IV stenosis. Fourteen (14%) patients required revision open surgery. The most common cause of revision surgery was posterior glottic stenosis. Partial anastomotic dehiscence was seen in four patients. Delayed decannulation (>1 year) occurred in nine patients. Overall mortality rate in the whole series was 6 percent. No deaths were directly related to the surgery. No iatrogenic recurrent laryngeal nerve injury was present in the entire series. CONCLUSION: Comorbidities and associated syndromes should be addressed before PCTR is planned to improve the final postoperative outcome in terms of decannulation. Perioperative morbidity due to anastomotic dehiscence, to a certain extent, can be avoided by intraoperative judgment in the selection of double-stage surgery when more than five tracheal rings need to be resected. Subglottic stenosis with glottic involvement continues to pose a difficult challenge to pediatric otolaryngologists, often necessitating revision procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The Advisa MRI system is designed to safely undergo magnetic resonance imaging (MRI). Its influence on image quality is not well known. OBJECTIVE: To evaluate cardiac magnetic resonance (CMR) image quality and to characterize myocardial contraction patterns by using the Advisa MRI system. METHODS: In this international trial with 35 participating centers, an Advisa MRI system was implanted in 263 patients. Of those, 177 were randomized to the MRI group and 150 underwent MRI scans at the 9-12-week visit. Left ventricular (LV) and right ventricular (RV) cine long-axis steady-state free precession MR images were graded for quality. Signal loss along the implantable pulse generator and leads was measured. The tagging CMR data quality was assessed as the percentage of trackable tagging points on complementary spatial modulation of magnetization acquisitions (n=16) and segmental circumferential fiber shortening was quantified. RESULTS: Of all cine long-axis steady-state free precession acquisitions, 95% of LV and 98% of RV acquisitions were of diagnostic quality, with 84% and 93%, respectively, being of good or excellent quality. Tagging points were trackable from systole into early diastole (360-648 ms after the R-wave) in all segments. During RV pacing, tagging demonstrated a dyssynchronous contraction pattern, which was not observed in nonpaced (n = 4) and right atrial-paced (n = 8) patients. CONCLUSIONS: In the Advisa MRI study, high-quality CMR images for the assessment of cardiac anatomy and function were obtained in most patients with an implantable pacing system. In addition, this study demonstrated the feasibility of acquiring tagging data to study the LV function during pacing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Regarding recent progress, musculoskeletal ultrasound (US) will probably soon be integrated in standard care of patient with rheumatoid arthritis (RA). However, in daily care, quality of US machines and level of experience of sonographers are varied. We conducted a study to assess reproducibility and feasibility of an US scoring for RA, including US devices of different quality and rheumatologist with various levels of expertise in US as it would be in daily care. METHODS: The Swiss Sonography in Arthritis and Rheumatism (SONAR) group has developed a semi-quantitative score using OMERACT criteria for synovitis and erosion in RA. The score was taught to 108 rheumatologists trained in US. One year after the last workshop, 19 rheumatologists participated in the study. Scans were performed on 6 US machines ranging from low to high quality, each with a different patient. Weighted kappa was calculated for each pair of readers. RESULTS: Overall, the agreement was fair to moderate. Quality of device, experience of the sonographers and practice of the score before the study improved substantially the agreement. Agreement assessed on higher quality machine, among sonographers with good experience in US increased to substantial (median kappa for B-mode and Doppler: 0.64 and 0.41 for erosion). CONCLUSIONS: This study demonstrated feasibility and reproducibility of the Swiss US SONAR score for RA. Our results confirmed importance of the quality of US machine and the training of sonographers for the implementation of US scoring in the routine daily care of RA.