33 resultados para CHIRAL ORGANOSELENIUM COMPOUNDS
Resumo:
One aim of this study is to determine the impact of water velocity on the uptake of indicator polychlorinated biphenyls (iPCBs) by silicone rubber (SR) and low-density polyethylene (LDPE) passive samplers. A second aim is to assess the efficiency of performance reference compounds (PRCs) to correct for the impact of water velocity. SR and LDPE samplers were spiked with 11 or 12 PRCs and exposed for 6 weeks to four different velocities (in the range of 1.6 to 37.7 cm s−1) in river-like flow conditions using a channel system supplied with river water. A relationship between velocity and the uptakewas found for each iPCB and enables to determine expected changes in the uptake due to velocity variations. For both samplers, velocity increases from 2 to 10 cm s−1, 30 cm s−1 (interpolated data) and 100 cm s−1 (extrapolated data) lead to increases of the uptake which do not exceed a factor of 2, 3 and 4.5, respectively. Results also showed that the influence of velocity decreased with increasing the octanol-water coefficient partition (log Kow) of iPCBs when SR is used whereas the opposite effect was observed for LDPE. Time-weighted average (TWA) concentrations of iPCBs in water were calculated from iPCB uptake and PRC release. These calculations were performed using either a single PRC or all the PRCs. The efficiency of PRCs to correct the impact of velocity was assessed by comparing the TWA concentrations obtained at the four tested velocities. For SR, a good agreement was found among the four TWA concentrations with both methods (average RSD b 10%). Also for LDPE, PRCs offered a good correction of the impact of water velocity (average RSD of about 10 to 20%). These results contribute to the process of acceptance of passive sampling in routine regulatory monitoring programs.
Resumo:
OBJECTIVES: Invasive mould infections are associated with a high mortality rate and the emergence of MDR moulds is of particular concern. Calcineurin and its chaperone, the heat shock protein 90 (Hsp90), represent an important pathway for fungal virulence that can be targeted at different levels. We investigated the antifungal activity of compounds directly or indirectly targeting the Hsp90-calcineurin axis against different mould species. METHODS: The in vitro antifungal activity of the anticalcineurin drug FK506 (tacrolimus), the Hsp90 inhibitor geldanamycin, the lysine deacetylase inhibitor trichostatin A and the Hsp70 inhibitor pifithrin-μ was assessed by the standard broth dilution method against 62 clinical isolates of Aspergillus spp. and non-Aspergillus moulds (Mucoromycotina, Fusarium spp., Scedosporium spp., Purpureocillium/Paecilomyces spp. and Scopulariopsis spp.) RESULTS: FK506 had variable antifungal activity against different Aspergillus spp. and was particularly active against Mucor spp. Geldanamycin had moderate antifungal activity against Fusarium spp. and Paecilomyces variotii. Importantly, trichostatin A had good activity against the triazole-resistant Aspergillus ustus and the amphotericin B-resistant Aspergillus terreus as well as the MDR Scedosporium prolificans. Moreover, trichostatin A exhibited synergistic interactions with caspofungin against A. ustus and with geldanamycin against Rhizopus spp. for which none of the other agents showed activity. Pifithrin-μ exhibited little antifungal activity. CONCLUSIONS: Targeting the Hsp90-calcineurin axis at different levels resulted in distinct patterns of susceptibility among different fungal species. Lysine deacetylase inhibition may represent a promising novel antifungal strategy against emerging resistant moulds.
Resumo:
A headspace-gas chromatography-tandem mass spectrometry (HS-GC-MS/MS) method for the trace measurement of perfluorocarbon compounds (PFCs) in blood was developed. Due to oxygen carrying capabilities of PFCs, application to doping and sports misuse is speculated. This study was therefore extended to perform validation methods for F-tert-butylcyclohexane (Oxycyte(®)), perfluoro(methyldecalin) (PFMD) and perfluorodecalin (PFD). The limit of detection of these compounds was established and found to be 1.2µg/mL blood for F-tert-butylcyclohexane, 4.9µg/mL blood for PFMD and 9.6µg/mL blood for PFD. The limit of quantification was assumed to be 12µg/mL blood (F-tert-butylcyclohexane), 48µg/mL blood (PFMD) and 96µg/mL blood (PFD). HS-GC-MS/MS technique allows detection from 1000 to 10,000 times lower than the estimated required dose to ensure a biological effect for the investigated PFCs. Thus, this technique could be used to identify a PFC misuse several hours, maybe days, after the injection or the sporting event. Clinical trials with those compounds are still required to evaluate the validation parameters with the calculated estimations.