207 resultados para Blood Gas Monitoring, Transcutaneous


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A small proportion of the treated hypertensive population consistently has a blood pressure greater than 140/90 mm Hg despite a triple therapy including a diuretic, a calcium channel blocker, and a blocker of the renin-angiotensin system. According to guidelines, these patients have so-called resistant hypertension. The prevalence of this clinical condition is higher in tertiary than primary care centers and often is associated with chronic kidney disease, diabetes, obesity, and sleep apnea syndrome. Exclusion of pseudoresistant hypertension using ambulatory or home blood pressure monitoring is a crucial step in the investigation of patients with resistant hypertension. Thus, among the multiple factors to consider when investigating patients with resistant hypertension, ambulatory blood pressure monitoring should be performed very early. Among other factors to consider, physicians should investigate patient adherence to therapy, assess the adequacy of treatment, exclude interfering factors, and, finally, look for secondary forms of hypertension. Poor adherence to therapy accounts for 30% to 50% of cases of resistance to therapy depending on the methodology used to diagnose adherence problems. This review discusses the clinical factors implicated in the pathogenesis of resistant hypertension with a particular emphasis on pseudoresistance, drug adherence, and the use of ambulatory blood pressure monitoring for the diagnosis and management of resistant hypertension.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pulse oximetry has been proposed as a noninvasive continuous method for transcutaneous monitoring of arterial oxygen saturation of hemoglobin (tcSO2) in the newborn infant. The reliability of this technique in detecting hyperoxemia is controversial, because small changes in saturation greater than 90% are associated with relatively large changes in arterial oxygen tension (PaO2). The purpose of this study was to assess the reliability of pulse oximetry using an alarm limit of 95% tcSO2 in detecting hyperoxemia (defined as PaO2 greater than 90 mm Hg) and to examine the effect of varying the alarm limit on reliability. Two types of pulse oximeter were studied alternately in 50 newborn infants who were mechanically ventilated with indwelling arterial lines. Three arterial blood samples were drawn from every infant during routine increase of inspired oxygen before intratracheal suction, and PaO2 was compared with tcSO2. The Nellcor N-100 pulse oximeter identified all 26 hyperoxemic instances correctly (sensitivity 100%) and alarmed falsely in 25 of 49 nonhyperoxemic instances (specificity 49%). The Ohmeda Biox 3700 pulse oximeter detected 13 of 35 hyperoxemic instances (sensitivity 37%) and alarmed falsely in 7 of 40 nonhyperoxemic instances (specificity 83%). The optimal alarm limit, defined as a sensitivity of 95% or more associated with maximal specificity, was determined for Nellcor N-100 at 96% tcSO2 (specificity 38%) and for Ohmeda Biox 3700 at 89% tcSO2 (specificity 52%). It was concluded that pulse oximeters can be highly sensitive in detecting hyperoxemia provided that type-specific alarm limits are set and a low specificity is accepted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

IMPLICATIONS: A new combined ear sensor was tested for accuracy in 20 critically ill children. It provides noninvasive and continuous monitoring of arterial oxygen saturation, arterial carbon dioxide tension, and pulse rate. The sensor proved to be clinically accurate in the tested range.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Poor long-term adherence is an important cause of uncontrolled hypertension. We examined whether monitoring drug adherence with an electronic system improves long-term blood pressure (BP) control in hypertensive patients followed by general practitioners (GPs). METHODS: A pragmatic cluster randomised controlled study was conducted over one year in community pharmacists/GPs' networks randomly assigned either to usual care (UC) where drugs were dispensed as usual, or to intervention (INT) group where drug adherence could be monitored with an electronic system (Medication Event Monitoring System). No therapy change was allowed during the first 2 months in both groups. Thereafter, GPs could modify therapy and use electronic monitors freely in the INT group. The primary outcome was a target office BP<140/90 mmHg. RESULTS: Sixty-eight treated uncontrolled hypertensive patients (UC: 34; INT: 34) were enrolled. Over the 12-month period, the likelihood of reaching the target BP was higher in the INT group compared to the UC group (p<0.05). At 4 months, 38% in the INT group reached the target BP vs. 12% in the UC group (p<0.05), and 21% vs. 9% at 12 months (p: ns). Multivariate analyses, taking account of baseline characteristics, therapy modification during follow-up, and clustering effects by network, indicate that being allocated to the INT group was associated with a greater odds of reaching the target BP at 4 months (p<0.01) and at 12 months (p=0.051). CONCLUSION: GPs monitoring drug adherence in collaboration with pharmacists achieved a better BP control in hypertensive patients, although the impact of monitoring decreased with time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In acute respiratory failure, arterial blood gas analysis (ABG) is used to diagnose hypercapnia. Once non-invasive ventilation (NIV) is initiated, ABG should at least be repeated within 1 h to assess PaCO2 response to treatment in order to help detect NIV failure. The main aim of this study was to assess whether measuring end-tidal CO2 (EtCO2) with a dedicated naso-buccal sensor during NIV could predict PaCO2 variation and/or PaCO2 absolute values. The additional aim was to assess whether active or passive prolonged expiratory maneuvers could improve the agreement between expiratory CO2 and PaCO2. METHODS: This is a prospective study in adult patients suffering from acute hypercapnic respiratory failure (PaCO2 ≥ 45 mmHg) treated with NIV. EtCO2 and expiratory CO2 values during active and passive expiratory maneuvers were measured using a dedicated naso-buccal sensor and compared to concomitant PaCO2 values. The agreement between two consecutive values of EtCO2 (delta EtCO2) and two consecutive values of PaCO2 (delta PaCO2) and between PaCO2 and concomitant expiratory CO2 values was assessed using the Bland and Altman method adjusted for the effects of repeated measurements. RESULTS: Fifty-four datasets from a population of 11 patients (8 COPD and 3 non-COPD patients), were included in the analysis. PaCO2 values ranged from 39 to 80 mmHg, and EtCO2 from 12 to 68 mmHg. In the observed agreement between delta EtCO2 and deltaPaCO2, bias was -0.3 mmHg, and limits of agreement were -17.8 and 17.2 mmHg. In agreement between PaCO2 and EtCO2, bias was 14.7 mmHg, and limits of agreement were -6.6 and 36.1 mmHg. Adding active and passive expiration maneuvers did not improve PaCO2 prediction. CONCLUSIONS: During NIV delivered for acute hypercapnic respiratory failure, measuring EtCO2 using a dedicating naso-buccal sensor was inaccurate to predict both PaCO2 and PaCO2 variations over time. Active and passive expiration maneuvers did not improve PaCO2 prediction. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01489150.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The traditional basis for assessing the effect of antihypertensive therapy is the blood pressure reading taken by a physician. However, several recent trials have been designed to evaluate the blood pressure lowering effect of various therapeutic agents during the patients' normal daytime activities, using a portable, semi-automatic blood pressure recorder. The results have shown that in a given patient, blood pressure measured at the physician's office often differs greatly from that prevailing during the rest of the day. This is true both in treated and untreated hypertensive patients. The difference between office and ambulatory recorded pressures cannot be predicted from blood pressure levels measured by the physician. Therefore, a prospective study was carried out in patients with diastolic blood pressures that were uncontrolled at the physician's office despite antihypertensive therapy. The purpose was to evaluate the response of recorded ambulatory blood pressure to treatment adjustments aimed at reducing office blood pressure below a pre-set target level. Only patients with high ambulatory blood pressures at the outset appeared to benefit from further changes in therapy. Thus, ambulatory blood pressure monitoring can be used to identify those patients who remain hypertensive only when facing the physician, despite antihypertensive therapy. Ambulatory monitoring could thus help to evaluate the efficacy of antihypertensive therapy and allow individual treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Renal cytochrome P450 3A5 (CYP3A5) activity has been associated with blood pressure and salt sensitivity in humans. We determined whether CYP3A5 polymorphisms are associated with ambulatory blood pressure (ABP) and with glomerular filtration rate (GFR) in African families. METHODS: Using a cross-sectional design, 375 individuals from 72 families, each with at least two hypertensive siblings, were recruited through a hypertension register in the Seychelles (Indian Ocean). We analyzed the association between the CYP3A5 alleles (*1, *3, *6 and *7) and ABP, GFR and renal sodium handling (fractional excretion of lithium), from pedigree data, allowing for other covariates and familial correlations. RESULTS: CYP3A5*1 carriers increased their daytime systolic and diastolic ABP with age (0.55 and 0.23 mmHg/year) more than non-carriers (0.21 and 0.04 mmHg/year). CYP3A5*1 had a significant main effect on daytime systolic/diastolic ABP [regression coefficient (SE): -29.6 (10.0)/-8.2 (4.1) mmHg, P = 0.003/0.045, respectively] and this effect was modified by age (CYP3A5*1 x age interactions, P = 0.017/0.018). For night-time ABP, the effect of CYP3A5*1 was modified by urinary sodium excretion, not by age. For renal function, CYP3A5*1 carriers had a 7.6(3.8) ml/min lower GFR (P = 0.045) than non-carriers. Proximal sodium reabsorption decreased with age in non-carriers, but not in CYP3A5*1 carriers (P for interaction = 0.02). CONCLUSIONS: These data demonstrate that CYP3A5 polymorphisms are associated with ambulatory BP, CYP3A5*1 carriers showing a higher age- and sodium- related increase in ABP than non-carriers. The age effect may be due, in part, to the action of CYP3A5 on renal sodium handling.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The permeability-glycoprotein efflux-transporter encoded by the multidrug resistance 1 (ABCB1) gene and the cytochromes P450 3A4/5 encoded by the CYP3A4/5 genes are known to interact in the transport and metabolism of many drugs. Recent data have shown that the CYP3A5 genotypes influence blood pressure and that permeability-glycoprotein activity might influence the activity of the renin-angiotensin system. Hence, these 2 genes may contribute to blood pressure regulation in humans. We analyzed the association of variants of the ABCB1 and CYP3A5 genes with ambulatory blood pressure, plasma renin activity, plasma aldosterone, endogenous lithium clearance, and blood pressure response to treatment in 72 families (373 individuals; 55% women; mean age: 46 years) of East African descent. The ABCB1 and CYP3A5 genes interact with urinary sodium excretion in their effect on ambulatory blood pressure (daytime systolic: P=0.05; nighttime systolic and diastolic: P<0.01), suggesting a gene-gene-environment interaction. The combined action of these genes is also associated with postproximal tubular sodium reabsorption, plasma renin activity, plasma aldosterone, and with an altered blood pressure response to the angiotensin-converting enzyme inhibitor lisinopril (P<0.05). This is the first reported association of the ABCB1 gene with blood pressure in humans and demonstration that genes encoding for proteins metabolizing and transporting drugs and endogenous substrates contribute to blood pressure regulation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We estimated the heritability of ambulatory systolic blood pressure (SBP), diastolic blood pressure (DBP), and pulse pressure (PP) in east African families with at least 2 hypertensive siblings and living in the Seychelles islands (Indian Ocean). The sample consisted of 314 individuals (147 men and 167 women), both normotensive and hypertensive, from 76 pedigrees (mean+/-SD of 4.1+/-2.8 persons per pedigree). After a 2-week off-treatment period, daytime and nighttime ambulatory blood pressure (BP) was monitored. Office BP was measured with a standard mercury sphygmomanometer. We estimated by maximum likelihood the age- and sex-adjusted heritabilities from the additive polygenic component of the variance of the traits allowing for the presence of other familial correlations. We also adjusted for ascertainment (ie, for the fact that 2 siblings had to be hypertensive) and examined the effect of adjusting for body mass index, 24-hour urinary excretion of sodium and potassium, plasma renin activity, and plasma aldosterone concentration. Heritability estimates (+/-SE) for ambulatory SBP, DBP, and PP were, respectively, 0.37+/-0.12/0.24+/-0.12/0.54+/-0.12 for daytime and 0.34+/-0.13/ 0.37+/-0.15/0.47+/-0.12 for nighttime measurements (P<0.05 for all estimates). Heritability estimates for office SBP, DBP, and PP were, respectively, 0.20+/-0.11, 0.05+/-0.09, and 0.37+/-0.12. Heritability estimates for SBP varied markedly according to whether participants were treated for hypertension at baseline. The present data show that ambulatory BP and PP have a high heritability in families of African descent. They also demonstrate that antihypertensive treatment and the number of BP measurements have a major influence on the heritability estimates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Recent trials have documented no benefit from small reductions in blood pressure measured in the clinical office. However, ambulatory blood pressure is a better predictor of cardiovascular events than office-based blood pressure. We assessed control of ambulatory blood pressure in treated hypertensive patients at high cardiovascular risk. METHODS: We selected 4729 patients from the Spanish Ambulatory Blood Pressure Monitoring Registry. Patients were aged >/=55 years and presented with at least one of the following co-morbidities: coronary heart disease, stroke, and diabetes with end-organ damage. An average of 2 measures of blood pressure in the office was used for analyses. Also, 24-hour ambulatory blood pressure was recorded at 20-minute intervals with a SpaceLabs 90207 device. RESULTS: Patients had a mean age of 69.6 (+/-8.2) years, and 60.8% of them were male. Average time from the diagnosis of hypertension to recruitment into the Registry was 10.9 (+/-8.4) years. Mean blood pressure in the office was 152.3/82.3 mm Hg, and mean 24-hour ambulatory blood pressure was 133.3/72.4 mm Hg. About 60% of patients with an office-pressure of 130-139/85-89 mm Hg, 42.4% with office-pressure of 140-159/90-99 mm Hg, and 23.3% with office-pressure > or =160/100 mm Hg were actually normotensive, according to 24-hour ambulatory blood pressure criteria (<130/80 mm Hg). CONCLUSION: We suggest that the lack of benefit of antihypertensive therapy in some trials may partly be due to some patients having normal pressure at trial baseline. Ambulatory monitoring of blood pressure may allow for a better assessment of trial eligibility.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Postoperative neurosurgical patients are at risk of developing complications. Systemic and neuro-monitoring are used to identify patients who deteriorate in order to treat the underlying cause and minimize the impact on outcome. Hypotension and hypoxia are likely to be the most frequent insults and can be detected easily with blood pressure monitoring and pulse oximetry. Repeated clinical examination, however, is probably the most important monitor in the postoperative setting. Clinical scores such as the Glasgow Coma Score and the more recently introduced FOUR Score are important tools to standardize the clinical assessment. Intracranial pressure monitoring, cerebral blood flow monitoring, electroencephalography, and brain imaging are often used postoperatively. Despite the numerous publications on this topic only few studies address the impact of postoperative monitoring on outcome. Accordingly, in most patients the decision on which monitors are to be used must be based on the patient's presentation and clinical judgment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To test a method that allows automatic set-up of the ventilator controls at the onset of ventilation. DESIGN: Prospective randomized crossover study. SETTING: ICUs in one adult and one children's hospital in Switzerland. PATIENTS: Thirty intubated stable, critically ill patients (20 adults and 10 children). INTERVENTIONS: The patients were ventilated during two 20-min periods using a modified Hamilton AMADEUS ventilator. During the control period the ventilator settings were chosen immediately prior to the study. During the other period individual settings were automatically determined by the ventilatior (AutoInit). MEASUREMENTS AND RESULTS: Pressure, flow, and instantaneous CO2 concentration were measured at the airway opening. From these measurements, series dead space (V(DS)), expiratory time constant (RC), tidal volume (VT, total respiratory frequency (f(tot), minute ventilation (MV), and maximal and mean airway pressure (Paw, max and Paw, mean) were calculated. Arterial blood gases were analyzed at the end of each period. Paw, max was significantly less with the AutoInit ventilator settings while f(tot) was significantly greater (P < 0.05). The other values were not statistically significant. CONCLUSIONS: The AutoInit ventilator settings, which were automatically derived, were acceptable for all patients for a period of 20 min and were not found to be inferior to the control ventilator settings. This makes the AutoInit method potentially useful as an automatic start-up procedure for mechanical ventilation.