52 resultados para BUILT-IN FIELD


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Recent laboratory studies have suggested that heart rate variability (HRV) may be an appropriate criterion for training load (TL) quantification. The aim of this study was to validate a novel HRV index that may be used to assess TL in field conditions. Eleven well-trained long-distance male runners performed four exercises of different duration and intensity. TL was evaluated using Foster and Banister methods. In addition, HRV measurements were performed 5 minutes before exercise and 5 and 30 minutes after exercise. We calculated HRV index (TLHRV) based on the ratio between HRV decrease during exercise and HRV increase during recovery. HRV decrease during exercise was strongly correlated with exercise intensity (R = -0.70; p < 0.01) but not with exercise duration or training volume. TLHRV index was correlated with Foster (R = 0.61; p = 0.01) and Banister (R = 0.57; p = 0.01) methods. This study confirms that HRV changes during exercise and recovery phase are affected by both intensity and physiological impact of the exercise. Since the TLHRV formula takes into account the disturbance and the return to homeostatic balance induced by exercise, this new method provides an objective and rational TL index. However, some simplification of the protocol measurement could be envisaged for field use.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We propose a new method, based on inertial sensors, to automatically measure at high frequency the durations of the main phases of ski jumping (i.e. take-off release, take-off, and early flight). The kinematics of the ski jumping movement were recorded by four inertial sensors, attached to the thigh and shank of junior athletes, for 40 jumps performed during indoor conditions and 36 jumps in field conditions. An algorithm was designed to detect temporal events from the recorded signals and to estimate the duration of each phase. These durations were evaluated against a reference camera-based motion capture system and by trainers conducting video observations. The precision for the take-off release and take-off durations (indoor < 39 ms, outdoor = 27 ms) can be considered technically valid for performance assessment. The errors for early flight duration (indoor = 22 ms, outdoor = 119 ms) were comparable to the trainers' variability and should be interpreted with caution. No significant changes in the error were noted between indoor and outdoor conditions, and individual jumping technique did not influence the error of take-off release and take-off. Therefore, the proposed system can provide valuable information for performance evaluation of ski jumpers during training sessions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Exogenous administration of glucocorticoids is a widely used and efficient tool to investigate the effects of elevated concentrations of these hormones in field studies. Because the effects of corticosterone are dose and duration-dependent, the exact course of plasma corticosterone levels after exogenous administration needs to be known. We tested the performance of self-degradable corticosterone pellets (implanted under the skin) in elevating plasma corticosterone levels. We monitored baseline (sampled within 3min after capture) total corticosterone levels and investigated potential interactions with corticosteroid-binding-globulin (CBG) capacity and the endogenous corticosterone response to handling in Eurasian kestrel Falco tinnunculus and barn owl Tyto alba nestlings. Corticosterone pellets designed for a 7-day-release in rodents elevated circulating baseline total corticosterone during only 2-3 days compared to placebo-nestlings. Highest levels occurred 1-2days after implantation and levels decreased strongly thereafter. CBG capacity was also increased, resulting in a smaller, but still significant, increase in baseline free corticosterone levels. The release of endogenous corticosterone as a response to handling was strong in placebo-nestlings, but absent 2 and 8 days after corticosterone pellet implantation. This indicates a potential shut-down of the hypothalamo-pituitary-adrenal axis after the 2-3 days of elevated baseline corticosterone levels. 20 days after pellet implantation, the endogenous corticosterone response to handling of nestlings implanted with corticosterone pellets attained similar levels as in placebo-nestlings. Self-degradable pellets proved to be an efficient tool to artificially elevate circulating baseline corticosterone especially in field studies, requiring only one intervention. The resulting peak-like elevation of circulating corticosterone, the concomitant elevation of CBG capacity, and the absence of an endogenous corticosterone response to an acute stressor have to be taken into account.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Solid phase microextraction (SPME) has been widely used for many years in various applications, such as environmental and water samples, food and fragrance analysis, or biological fluids. The aim of this study was to suggest the SPME method as an alternative to conventional techniques used in the evaluation of worker exposure to benzene, toluene, ethylbenzene, and xylene (BTEX). Polymethylsiloxane-carboxen (PDMS/CAR) showed as the most effective stationary phase material for sorbing BTEX among other materials (polyacrylate, PDMS, PDMS/divinylbenzene, Carbowax/divinylbenzene). Various experimental conditions were studied to apply SPME to BTEX quantitation in field situations. The uptake rate of the selected fiber (75 microm PDMS/CAR) was determined for each analyte at various concentrations, relative humidities, and airflow velocities from static (calm air) to dynamic (> 200 cm/s) conditions. The SPME method also was compared with the National Institute of Occupational Safety and Health method 1501. Unlike the latter, the SPME approach fulfills the new requirement for the threshold limit value-short term exposure limit (TLV-STEL) of 2.5 ppm for benzene (8 mg/m(3))

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: The aim of this study was to investigate the feasibility of transventricular-transseptal approach (TVSA) for extrapleural transcatheter aortic valved stent implantation via a subxyphoidian access. Methods: In five porcine experiments (52.3 +/- 10.9 kg) the right ventricle was exposed via subxyphoidian access. Under the guidance of intracardiac echocardiography (ICE) and fluoroscopy, the transseptal access from right ventricle to left ventricle was created progressively by puncture and dilation with dilators (8F-26F). Valved stents built in-house from commercial tanned pericardium and self-expandable Nitinol stents were loaded into a cartridge. A delivery sheath was then introduced from the right ventricle into the left ventricle and then into the ascending aorta. The cartridge was connected and the valved stent was deployed in the aortic position. Then, the ventricular septal access was sealed with an Amplatzer septal occluder device and the right ventricular access was closed by tying prepared purse-string suture directly. Thirty minutes after the whole procedure, the animals were sacrificed for macroscopic evaluation of the position of valved stent and septal closure device. Result: Procedural success of TVSA was 100% at the first attempt. Mean procedure time was 49 +/- 4 min. Progressive dilatation of the transseptal access resulted in a measurable ventricular septal defect (VSD) after dilator sizes 18F and more. All valved stents were delivered at the target site over the native aortic valve with good acute valve function and no paravalvular leaks. During the procedure, premature beats (5/5) and supraventriclar tachycardias (5/5) were observed, but no atrial-ventricular block (0/5) occurred. Heart rate before (after) was 90 +/- 3 beats min(-1) (100 +/- 2 beats min(-1): p < 0.05), whereas blood pressure was 60 + 1 mm Hg (55 + 2 mm Hg (p < 0.05)). Total blood loss was 280 + 10 ml. The Amplatzer septal occluder devices were fully deployed and the ventricular septal accesses were sealed successfully, without detectable residual shunt. Conclusion: Trans-catheter implantation of aortic valved stent via extrapleural transventricular-transseptal access is technically feasible and has the potential for a simplified procedure under local anaesthesia. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B. V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

During recovery from a maximal or submaximal aerobic exercise, augmentation of central (aortic) systolic pressure by reflected pressure waves is blunted in healthy humans. However, the extent to which reflected pressure waves modify the central pulse in diastole in these conditions remains unknown. We evaluated systolic and diastolic central reflected waves in 11 endurance-trained athletes on recovery from a maximal running test on a treadmill (treadmill-max) and a 4000 m run in field conditions. On both occasions in each subject, the radial pulse was recorded with applanation tonometry in the resting preexercise state and then 5, 15, 25, 35, and 45 min after exercise termination. From the central waveform, as reconstructed by application of a generalized transfer function, we computed a systolic (AIx) and a diastolic index (AId) of pressure augmentation by reflections. At 5 min, both indices were below preexercise. At further time-points, AIx remained low, while AId progressively increased, to overshoot above preexercise at 45 min. The same behavior was observed with both exercise types. Beyond the first few minutes of recovery following either maximal or submaximal aerobic exercise, reflected waves selectively augment the central pressure pulse in diastole, at least in endurance-trained athletes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Exposure to solar ultraviolet (UV) radiation is the main causative factor for skin cancer. UV exposure depends on environmental and individual factors, but individual exposure data remain scarce. While ground UV irradiance is monitored via different techniques, it is difficult to translate such observations into human UV exposure or dose because of confounding factors. A multi-disciplinary collaboration developed a model predicting the dose and distribution of UV exposure on the basis of ground irradiation and morphological data. Standard 3D computer graphics techniques were adapted to develop a simulation tool that estimates solar exposure of a virtual manikin depicted as a triangle mesh surface. The amount of solar energy received by various body locations is computed for direct, diffuse and reflected radiation separately. Dosimetric measurements obtained in field conditions were used to assess the model performance. The model predicted exposure to solar UV adequately with a symmetric mean absolute percentage error of 13% and half of the predictions within 17% range of the measurements. Using this tool, solar UV exposure patterns were investigated with respect to the relative contribution of the direct, diffuse and reflected radiation. Exposure doses for various body parts and exposure scenarios of a standing individual were assessed using erythemally-weighted UV ground irradiance data measured in 2009 at Payerne, Switzerland as input. For most anatomical sites, mean daily doses were high (typically 6.2-14.6 Standard Erythemal Dose, SED) and exceeded recommended exposure values. Direct exposure was important during specific periods (e. g. midday during summer), but contributed moderately to the annual dose, ranging from 15 to 24% for vertical and horizontal body parts, respectively. Diffuse irradiation explained about 80% of the cumulative annual exposure dose.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Isothermal microcalorimetry (IMC) has been used in the past to monitor metabolic activities in living systems. A few studies have used it on ecological research. In this study, IMC was used to monitor oxalotrophic activity, a widespread bacterial metabolism found in the environment, and particularly in soils. Six model strains were inoculated in solid angle media with K-oxalate as the sole carbon source. Cupriavidus oxalaticus, Cupriavidus necator, and Streptomyces violaceoruber presented the highest activity (91, 40, and 55 μW, respectively) and a maximum growth rate (μmax h(-1) ) of 0.264, 0.185, and 0.199, respectively, among the strains tested. These three strains were selected to test the incidence of different oxalate sources (Ca, Cu, and Fe-oxalate salts) in the metabolic activity. The highest activity was obtained in Ca-oxalate for C. oxalaticus. Similar experiments were carried out with a model soil to test whether this approach can be used to measure oxalotrophic activity in field samples. Although measuring oxalotrophic activity in a soil was challenging, there was a clear effect of the amendment with oxalate on the metabolic activity measured in soil. The correlation between heat flow and growth suggests that IMC analysis is a powerful method to monitor bacterial oxalotrophic activity

Relevância:

80.00% 80.00%

Publicador:

Resumo:

RESUMEDurant la phase de récupération d'un exercice de course à pied d'intensité maximale ou submaximale, une augmentation de la pression artérielle systolique centrale (aortique) résultant de la réflexion des ondes de pouls sur l'arbre vasculaire est constatée chez l'individu en bonne santé. En diastole cependant, l'impact de la réflexion de ces ondes de pouls sur la pression centrale demeure inconnu durant la récupération d'un exercice.Nous avons évalué les ondes de pouls centrales systolique et diastolique chez onze athlètes d'endurance durant la phase de récupération d'un exercice de course à pied dans des conditions d'effort maximal (sur tapis de course) et lors d'un effort submaximal lors d'une course à pied de 4000 mètres en plein air sur terrain mixte.Pour chaque sujet et lors des deux exercices, l'onde de pouls a été mesurée au niveau radial par tonométrie d'aplanation durant une phase de repos précédant l'exercice, puis à 5, 15, 25, 35 et 45 minutes après la fin de l'exercice. En utilisant une fonction mathématique de transfert, l'onde de pouls centrale a été extrapolée à partir de l'onde de pouls radiale. En compilant la forme de l'onde de pouls centrale avec une mesure simultanée de la pression artérielle brachiale, un index d'augmentation de l'onde de pouls en systole (Alx) et en diastole (Als) peut être calculé, reflétant l'augmentation des pressions résultant de la réflexion des ondes sur l'arbre vasculaire périphérique.A 5 minutes de la fin de l'exercice, les deux index ont été mesurés moindres que ceux mesurés lors de la phase précédant celui-ci. Lors des mesures suivantes, Alx est resté bas, alors que Aid a progressivement augmenté pour finalement dépasser la valeur de repos après 45 minutes de récupération. Le même phénomène a été constaté pour les deux modalités d'exercice (maximal ou submaximal). Ainsi, au-delà de quelques minutes de récupération après un exercice de course d'intensité maximale ou submaximale, nous avons montré par ces investigations que les ondes de pouls réfléchies en périphérie augmentent de façon sélective la pression centrale en diastole chez l'athlète d'endurance.ABSTRACTDuring recovery from a maximal or submaximal aerobic exercise, augmentation of central (aortic) systolic pressure by reflected pressure waves is blunted in healthy humans. However, the extent to which reflected pressure waves modify the central pulse in diastole in these conditions remains unknown. We evaluated systolic and diastolic central reflected waves in 11 endurance-trained athletes on recovery from a maximal running test on a treadmill (treadmill-max) and a 4000m run in field conditions. On both occasions in each subject, the radial pulse was recorded with applanation tonometry in the resting preexercise state and then 5, 15, 25, 35, and 45 minutes after exercise termination. From the central waveform, as reconstructed by application of a generalized transfer function, we computed a systolic (Alx) and a diastolic index (Aid) of pressure augmentation by reflections. At 5 minutes, both indices were below preexercise. At further time-points, Alx remained low, while Aid progressively increased, to overshoot above preexercise at 45 minutes. The same behavior was observed with both exercise types. Beyond the first few minutes of recovery following either maximal or submaximal aerobic exercise, reflected waves selectively augment the central pressure pulse in diastole, at least in endurance- trained athletes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study aimed to evaluate the impact of genetically modified (GM) wheat with introduced pm3b mildew resistance transgene, on two types of root-colonizing microorganisms, namely pseudomonads and arbuscular mycorrhizal fungi (AMF). Our investigations were carried out in field trials over three field seasons and at two locations. Serial dilution in selective King's B medium and microscopy were used to assess the abundance of cultivable pseudomonads and AMF, respectively. We developed a denaturing gradient gel electrophoresis (DGGE) method to characterize the diversity of the pqqC gene, which is involved in Pseudomonas phosphate solubilization. A major result was that in the first field season Pseudomonas abundances and diversity on roots of GM pm3b lines, but also on non-GM sister lines were different from those of the parental lines and conventional wheat cultivars. This indicates a strong effect of the procedures by which these plants were created, as GM and sister lines were generated via tissue cultures and propagated in the greenhouse. Moreover, Pseudomonas population sizes and DGGE profiles varied considerably between individual GM lines with different genomic locations of the pm3b transgene. At individual time points, differences in Pseudomonas and AMF accumulation between GM and control lines were detected, but they were not consistent and much less pronounced than differences detected between young and old plants, different conventional wheat cultivars or at different locations and field seasons. Thus, we conclude that impacts of GM wheat on plant-beneficial root-colonizing microorganisms are minor and not of ecological importance. The cultivation-independent pqqC-DGGE approach proved to be a useful tool for monitoring the dynamics of Pseudomonas populations in a wheat field and even sensitive enough for detecting population responses to altered plant physiology.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In many practical applications the state of field soils is monitored by recording the evolution of temperature and soil moisture at discrete depths. We theoretically investigate the systematic errors that arise when mass and energy balances are computed directly from these measurements. We show that, even with no measurement or model errors, large residuals might result when finite difference approximations are used to compute fluxes and storage term. To calculate the limits set by the use of spatially discrete measurements on the accuracy of balance closure, we derive an analytical solution to estimate the residual on the basis of the two key parameters: the penetration depth and the distance between the measurements. When the thickness of the control layer for which the balance is computed is comparable to the penetration depth of the forcing (which depends on the thermal diffusivity and on the forcing period) large residuals arise. The residual is also very sensitive to the distance between the measurements, which requires accurately controlling the position of the sensors in field experiments. We also demonstrate that, for the same experimental setup, mass residuals are sensitively larger than the energy residuals due to the nonlinearity of the moisture transport equation. Our analysis suggests that a careful assessment of the systematic mass error introduced by the use of spatially discrete data is required before using fluxes and residuals computed directly from field measurements.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Several methods and algorithms have recently been proposed that allow for the systematic evaluation of simple neuron models from intracellular or extracellular recordings. Models built in this way generate good quantitative predictions of the future activity of neurons under temporally structured current injection. It is, however, difficult to compare the advantages of various models and algorithms since each model is designed for a different set of data. Here, we report about one of the first attempts to establish a benchmark test that permits a systematic comparison of methods and performances in predicting the activity of rat cortical pyramidal neurons. We present early submissions to the benchmark test and discuss implications for the design of future tests and simple neurons models

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Lorsqu'il est amené à témoigner de sa conversion, le membre d'une assemblée pentecôtiste insiste avant tout sur la dimension personnelle de son choix de vie et sur les manifestations divines qui l'ont encouragées et qui l'encouragent encore chaque jour dans cette voie. Avoir fait l'expérience personnelle de l'agir divin est un élément constitutif de tout récit de conversion. Cet article, basée sur des recherches doctorales menées auprès de deux assemblées pentecôtistes de l'Est de la France, cherche à mettre en évidence que cette relation personnelle et intime entre le fidèle et son créateur se construit dans le cadre communautaire : à travers l'harmonisation des récits de conversion et la structuration des réunions de prières assurant par les manifestations charismatiques la mise en présence de l'Esprit Saint au sein de la communauté des fidèles. C'est en effet sur une validation communautaire que reposent en partie les convictions individuelles. When he has to testify of his conversion, the member of a Pentecostal assembly insists above all on the personal dimension of his choice of life and on the divine intervention which has encouraged him and which will encourage him in his everyday life in this way. The personal experience of God's action is a constituent element of any narrative of conversion. This article, based on my PhD researches carried on with two Pentecostal assemblies located in the east of France, tries to highlight that this personal and intimate relation between the believer and his creator is built in the community framework : harmonization of the narratives of conversion, structuralization of the meetings of prayers and charismatic interventions of the Holy Spirit within the community of the believers. Individual convictions are partly based and validated by the community.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Solid phase microextraction (SPME) has been widely used for many years in various applications, such as environmental and water samples, food and fragrance analysis, or biological fluids. The aim of this study was to suggest the SPME method as an alternative to conventional techniques used in the evaluation of worker exposure to benzene, toluene, ethylbenzene, and xylene (BTEX). Polymethylsiloxane-carboxen (PDMS/CAR) showed as the most effective stationary phase material for sorbing BTEX among other materials (polyacrylate, PDMS, PDMS/divinylbenzene, Carbowax/divinylbenzene). Various experimental conditions were studied to apply SPME to BTEX quantitation in field situations. The uptake rate of the selected fiber (75 μm PDMS/CAR) was determined for each analyte at various concentrations, relative humidities, and airflow velocities from static (calm air) to dynamic (>200 cm/s) conditions. The SPME method also was compared with the National Institute of Occupational Safety and Health method 1501. Unlike the latter, the SPME approach fulfills the new requirement for the threshold limit value-short term exposure limit (TLV-STEL) of 2.5 ppm for benzene (8 mg/m3).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Hi·Art II Helical TomoTherapy (HT) unit is equipped with a built-in onboard MVCT detector used for patient imaging and beam monitoring. Our aim was to study the detector stability for treatment beam measurements. We studied the MVCT detector response with the 6 MV photon beam over time, throughout short-term (during an irradiation) and long-term (two times 50 days) periods. Our results show a coefficient of variation ≤ 1% for detector chambers inside the beam (excluding beam gradients) for short- and long-term response of the MVCT detector. Larger variations were observed in beam gradients and an influence of the X-ray target where degradation was found. The results assume that an 'air scan' procedure is performed daily to recalibrate the detector with the imaging beam. On short term, the detector response stability is comparable to other devices. Long-term measure- ments during two 50-day periods show a good reproducibility.