68 resultados para BALANCED OCCLUSION
Resumo:
BACKGROUND AND PURPOSE: We aimed to assess the interaction between intravenous thrombolysis (IVT) and arterial occlusion on acute cervicocerebral computed tomographic angiography on the outcome of patients with acute ischemic stroke. METHODS: Patients from the Acute Stroke Registry and Analysis of Lausanne (ASTRAL) registry with onset-to-door-time ≤4 hours, acute cervicocerebral computed tomographic angiography, a premorbid modified Rankin Scale ≤2, and a National Institute of Health Stroke Scale (NIHSS) >4 were selected. Patients with significant intracranial arterial obstruction (≥50%-99%) and undergoing acute endovascular treatment were excluded. An interaction analysis of IVT and initial arterial occlusion for favorable 3 months outcome (modified Rankin Scale <3) were performed with adjustment for potential confounders. RESULTS: Among 654 included patients, 382 (58%) showed arterial occlusion, of whom 263 (69%) received IVT. Two hundred seventy-two showed no/minimal obstruction of whom 139 (51%) received IVT. In the adjusted interaction analysis, there was a trend in favor of the arterial occlusion group (odds ratio [OR]=3.97; 95% confidence interval [CI], 0.83-18.97; P=0.08). IVT (versus no IVT) was associated with better outcome in patients with occlusion (adjusted OR for favorable outcome, 3.01; 95% CI, 1.10-8.28) but not in patients with no/minimal obstruction (OR, 0.76; 95% CI, 0.21-2.74). Conversely, patients with occlusion had a similar rate of favorable outcome as no/minimal obstruction when thrombolysed (OR, 0.5; 95% CI, 0.17-1.47) but had a less favorable outcome without thrombolysis (OR, 0.13; 95% CI, 0.04-0.44). CONCLUSIONS: In this retrospective analysis of consecutive patients with acute ischemic stroke, there was a trend for more favorable outcomes with IVT in the setting of initial arterial occlusion than in the setting of no/minimal obstruction. Before confirmation in randomized controlled studies, this information should not influence thrombolysis decisions, however.
Resumo:
BACKGROUND: Transient balanced steady-state free-precession (bSSFP) has shown substantial promise for noninvasive assessment of coronary arteries but its utilization at 3.0 T and above has been hampered by susceptibility to field inhomogeneities that degrade image quality. The purpose of this work was to refine, implement, and test a robust, practical single-breathhold bSSFP coronary MRA sequence at 3.0 T and to test the reproducibility of the technique. METHODS: A 3D, volume-targeted, high-resolution bSSFP sequence was implemented. Localized image-based shimming was performed to minimize inhomogeneities of both the static magnetic field and the radio frequency excitation field. Fifteen healthy volunteers and three patients with coronary artery disease underwent examination with the bSSFP sequence (scan time = 20.5 ± 2.0 seconds), and acquisitions were repeated in nine subjects. The images were quantitatively analyzed using a semi-automated software tool, and the repeatability and reproducibility of measurements were determined using regression analysis and intra-class correlation coefficient (ICC), in a blinded manner. RESULTS: The 3D bSSFP sequence provided uniform, high-quality depiction of coronary arteries (n = 20). The average visible vessel length of 100.5 ± 6.3 mm and sharpness of 55 ± 2% compared favorably with earlier reported navigator-gated bSSFP and gradient echo sequences at 3.0 T. Length measurements demonstrated a highly statistically significant degree of inter-observer (r = 0.994, ICC = 0.993), intra-observer (r = 0.894, ICC = 0.896), and inter-scan concordance (r = 0.980, ICC = 0.974). Furthermore, ICC values demonstrated excellent intra-observer, inter-observer, and inter-scan agreement for vessel diameter measurements (ICC = 0.987, 0.976, and 0.961, respectively), and vessel sharpness values (ICC = 0.989, 0.938, and 0.904, respectively). CONCLUSIONS: The 3D bSSFP acquisition, using a state-of-the-art MR scanner equipped with recently available technologies such as multi-transmit, 32-channel cardiac coil, and localized B0 and B1+ shimming, allows accelerated and reproducible multi-segment assessment of the major coronary arteries at 3.0 T in a single breathhold. This rapid sequence may be especially useful for functional imaging of the coronaries where the acquisition time is limited by the stress duration and in cases where low navigator-gating efficiency prohibits acquisition of a free breathing scan in a reasonable time period.
Resumo:
The time-lag between coronary occlusion and irreversible damage to the myocardium is ill-defined in man. In 10 patients the changes in left ventricular function have been studied after coronary occlusion during diagnostic or therapeutic cardiac catheterization of 1-2 hours' duration. Revascularization was achieved either surgically or through intracoronary streptokinase infusion. The interval between occlusion and onset of extracorporal circulation or reopening was 61 to 119 minutes. Despite enzyme elevation (CPK, CK-MB, SGOT) and appearance of Q-waves in 5 patients, no significant alteration of left ventricular function was noted on repeat cardiac catheterization 10 to 230 days after the accident. These observations, suggest that coronary occlusion of 1-2 hours' duration fails to produce significant irreversible damage to the myocardium despite electrocardiographic and enzymatic signs of myocardial infarction.
Resumo:
The case of a man exposed during 25 years to vibration while maneuvering a heavy earth moving tractor is reported. The first clinical manifestation of hand-arm vibration syndrome was a bilateral Raynaud's phenomenon followed five years later by digital necrosis. The arteriography revealed a proximal and bilateral ulnar artery occlusion. Bilateral median nerve conduction abnormalities were also present. Vibration exposure level was much higher than the threshold level proposed by the European Commission. Laboratory examinations for vasculitis and other vascular diseases were all negative. The purpose of this report is to show that vibration can be responsible for proximal occlusion of a medium sized artery and severe neurovascular abnormalities which must be distinguished from the usual vasospastic Raynaud's phenomenon and the classical hypothenar hammer syndrome. An early and correct diagnosis is crucial because continued repetitive trauma can result in irreversible ischemic injury and loss of digits.
Resumo:
PURPOSE: The aim of our study was to describe the clinical presentation of an unusual evanescent, exudative, choroidal pseudo-tumor with acute painful onset, and propose a pathogenesis. METHODS: We carried out a retrospective, observational study using the case series of three patients presenting with an evanescent, exudative, choroidal pseudo-tumor with acute painful onset. Ultra-widefield fluorescein and indocyanine green angiography (ICGA) using the Heidelberg Retina Angiograph and the Staurenghi 230 SLO Retina Lens were used to propose a pathogenesis of this unusual entity. RESULTS: In all three cases, acute ocular pain led to discovery of an exudative, partially hemorrhagic choroidal mass (thickness 2.4 mm-4.1 mm on ultrasound) that quickly regressed within weeks. In the subacute phase, all patients showed choroidal circulation abnormalities on dynamic wide-field ICGA in the affected quadrant, with delayed arterio-venous filling in two patients, and a poorly-defined vortex vein in the third. The choroidal circulation abnormalities resolved within 8-12 weeks, simultaneously with the spontaneous resolution of the choroidal pseudo-tumor. The findings evoked a self-resolving vortex vein occlusion in the corresponding quadrants with acute, painful choroidal exudation. CONCLUSIONS: An evanescent, exudative, hemorragic choroidal pseudo-tumor with acute painful onset may be caused by a vortex vein occlusion. Future patients need to be studied with ICGA in the acute phase to confirm this hypothesis.
Resumo:
A cardiac-triggered free-breathing three-dimensional balanced fast field-echo projection magnetic resonance (MR) angiographic sequence with a two-dimensional pencil-beam aortic labeling pulse was developed for the renal arteries. For data acquisition during free breathing in eight healthy adults and seven consecutive patients with renal artery disease, real-time navigator technology was implemented. This technique allows high-spatial-resolution and high-contrast renal MR angiography and visualization of renal artery stenosis without exogenous contrast agent or breath hold. Initial promising results warrant larger clinical studies.
Resumo:
Purpose. To investigate the effect of the endothelin(A) receptor inhibitor BQ-123 on the retinal arteriolar vasculature in minipig retinas in normal eyes and eyes with acute branch retinal vein occlusion (BRVO). Methods. Seven healthy eyes of seven minipigs and six eyes of six minipigs with experimental BRVO were evaluated under systemic anesthesia. An intravitreal juxta-arteriolar microinjection of 30 microL BQ-123 0.61 microg/mL (pH 7.4) was performed in all but one eye from each group, into which the physiologic saline vehicle alone was injected. Vessel-diameter changes were measured with a retinal vessel analyzer. Results. In healthy minipig retinas (n = 6), arteriolar diameter (+/-SD) increased 6.19% +/- 3.55% (P < 0.05), 25.98% +/- 2.37% (P < 0.001), 23.65% +/- 1.2% (P < 0.001), and 16.84% +/- 1.95% (P < 0.001), at 1, 5, 10, and 15 minutes, respectively, after BQ-123 microinjection. Two hours after experimental BRVO (n = 5), the retinal arteriolar diameter had decreased (13.07% +/- 5.7%; P < 0.01). One, 5, 10, and 15 minutes after BQ-123 microinjection, retinal arteriolar diameter had increased by 7.14% +/- 3.3% (P < 0.01), 26.74% +/- 7.63% (P < 0.001), 23.67% +/- 6.4% (P < 0.001), and 16.09% +/- 3.41% (P < 0.001), respectively. Vehicle only injection had no vasoactive effect on physiologic or BRVO retinas. Conclusions. A significant increase in retinal arteriolar diameter was demonstrated after juxta-arteriolar BQ-123 microinjection in healthy and in acute BRVO minipig retinas. The results suggest a role for endothelin-1 in maintaining retinal basal arteriolar tone. Reversing the BRVO-related vasoconstriction by juxta-arteriolar BQ-123 microinjection could bring a new perspective to the management of BRVO.
Resumo:
PURPOSE: To improve the tag persistence throughout the whole cardiac cycle by providing a constant tag-contrast throughout all the cardiac phases when using balanced steady-state free precession (bSSFP) imaging. MATERIALS AND METHODS: The flip angles of the imaging radiofrequency pulses were optimized to compensate for the tagging contrast-to-noise ratio (Tag-CNR) fading at later cardiac phases in bSSFP imaging. Complementary spatial modulation of magnetization (CSPAMM) tagging was implemented to improve the Tag-CNR. Numerical simulations were performed to examine the behavior of the Tag-CNR with the proposed method, and to compare the resulting Tag-CNR with that obtained from the more commonly used spoiled gradient echo (SPGR) imaging. A gel phantom, as well as five healthy human volunteers, were scanned on a 1.5T scanner using bSSFP imaging with and without the proposed technique. The phantom was also scanned with SPGR imaging. RESULTS: With the proposed technique, the Tag-CNR remained almost constant during the whole cardiac cycle. Using bSSFP imaging, the Tag-CNR was about double that of SPGR. CONCLUSION: The tag persistence was significantly improved when the proposed method was applied, with better Tag-CNR during the diastolic cardiac phase. The improved Tag-CNR will support automated tagging analysis and quantification methods.
Resumo:
This article evaluates the results of portal vein (PV) stent placement in patients with malignant extrinsic lesions stenosing or obstructing the PV and causing symptomatic PV hypertension (PVHT). Fourteen patients with bile duct cancer (n = 7), pancreatic adenocarcinoma (n = 4), or another cancer (n = 3) underwent percutaneous transhepatic portal venous stent placement because of gastroesophageal or jejunal varices (n = 9), ascites (n = 7), and/or thrombocytopenia (n = 2). Concurrent tumoral obstruction of the main bile duct was treated via the transhepatic route in the same session in four patients. Changes in portal venous pressure, complications, stent patency, and survival were evaluated. Mean +/- standard deviation (SD) gradient of portal venous pressure decreased significantly immediately after stent placement from 11.2 mmHg +/- 4.6 to 1.1 mmHg +/- 1.0 (P < 0.00001). Three patients had minor complications, and one developed a liver abscess. During a mean +/- SD follow-up of 134.4 +/- 123.3 days, portal stents remained patent in 11 patients (78.6%); stent occlusion occurred in 3 patients, 2 of whom had undergone previous major hepatectomy. After stent placement, PVHT symptoms were relieved in four (57.1%) of seven patients who died (mean survival, 97 +/- 71.2 days), and relieved in six (85.7%) of seven patients still alive at the end of follow-up (mean follow-up, 171.7 +/- 153.5 days). Stent placement in the PV is feasible and relatively safe. It helped to relieve PVHT symptoms in a single session.
Resumo:
A cardiac-triggered, free-breathing, 3D balanced FFE projection renal MR angiography (MRA) technique with a 2D pencil beam aortic labeling pulse for selective aortic spin tagging was developed. For respiratory motion artifact suppression during free breathing, a prospective real-time navigator was implemented for renal MRA. Images obtained with the new approach were compared with standard contrast-enhanced (CE) 3D breath-hold MRA in seven swine. Signal properties and vessel visualization were analyzed. With the presented technique, high-resolution, high-contrast renal projection MRA with superior vessel length visualization (including a greater visible number of distal branches of the renal arteries) compared to standard breath-hold CE-MRA was obtained. The present results warrant clinical studies in patients with renal artery disease.